This study aimed to examine the effect of high tibial osteotomy (HTO) on the ankle and subtalar joints via analysis of static radiographic alignment. We hypothesised that surgical alteration of the alignment of the proximal tibia would result in compensatory distal changes. 35 patients recruited as part of the wider Biomechanics and Bioengineering Centre Versus Arthritis HTO study between 2011 and 2018 had pre- and postoperative full-length weightbearing radiographs taken of their lower limbs. In addition to standard alignment measures of the limb and knee (mechanical tibiofemoral angle, Mikulicz point, medial proximal tibial angle), additional measures were taken of the ankle/subtalar joints (lateral distal tibial angle, ground-talus angle, joint line convergence angle of the ankle) as well as a novel measure of stance width. Results were compared using a paired T-test and Pearson's correlation coefficient. Following HTO, there was a significant (5.4°) change in subtalar alignment. Ground-talus angle appeared related both to the level of malalignment preoperatively and the magnitude of the alignment change caused by the HTO surgery; suggesting subtalar positioning as a key adaptive mechanism. In addition to compensatory changes within the subtalar joints, the patients on average had a 31% wider stance following HTO. These two mechanisms do not appear to be correlated but the morphology of the tibial plafond may influence which compensatory mechanisms are employed by different subgroups of HTO patients. These findings are of vital importance in clinical practice both to anticipate potential changes to the ankle and subtalar joints following HTO but it could also open up wider indications for HTO in the treatment of ankle malalignment and osteoarthritis.
Medial knee OA effects approximately 4.1 million people in England. Non-surgical strategies to lower knee joint loading is commonly researched in the knee OA literature as a method to alleviate pain and discomfort. Medial knee OA is much more prevalent than lateral knee OA due to the weight bearing line passing medial to the knee causing an external knee adduction moment (KAM). Numerous potential gait retraining strategies have been proposed to reduce either the first and/or the second peak KAM, including: toe-in gait, toe-out gait, lateral trunk lean and medial thrust gait. Gait retraining has been researched with little regard to the biomechanical consequences at the hip and ankle joints. This systematic review aimed to establish whether gait retraining can reduce medial knee loading as assessed by first and second peak KAMs, establish what are the biomechanical effects a reduced KAM has on other lower limb joint biomechanics and outline patient/participant reported outcomes on how easy the gait retraining style was to implement. The protocol for this systematic review was registered with PROSPERO on the 23rd January 2018 (registration ID: CRD42018085738). 13 databases were searched by one author (J.B.B). Additionally, PROSPERO was searched for ongoing or recently completed systematic reviews. Risk of bias was assessed using the Downs and Black quality index. Search: Group one consisted of keywords “walk” OR “gait”. Keywords “knee” OR “adduction moment” built up the second group. Group three consisted “osteoarthriti” OR “arthriti” OR “osteo arthriti”, OR “OA”. Group four included “hip” OR “ankle”. the searched results of each group were combined with conjunction “AND” in all fields. Out of the eight different gait retraining strategies identified, trunk lean reduced first peak KAM the most, which was evaluated in 3 studies, reducing first peak KAM by 20%-65%. There was a lack of collective pelvic, hip and/or ankle joint biomechanical variables reported across all 11 studies. Of eight gait retraining styles identified, the strategy that reduced first peak KAM the most was an increased lateral trunk lean, which was evaluated in 3 different studies. This is the first systematic review that has highlighted that there is limited evidence of the biomechanical consequences of a reduced knee joint load has on the pelvic, hip and/or ankle joints when undertaking gait retraining protocols. Future studies assessing gait retraining strategies should provide biomechanical outputs for other lower limb joints other than the knee joint, as well as providing participant perceptions on the level of difficulty the gait style is to perform.
Risk factors for poor outcomes after total knee replacement (TKR) have been identified, but the underlying causes are not fully understood. The aim of this research was to establish the relationship between measurable gait parameters and patients' subjective function, pre and post total knee replacement. 25 subjects underwent gait analysis, before and one year following total knee replacement. Patient reported function was investigated using the Activities of Daily Living Scale of the Knee Outcome Survey (KOS). Gait analysis was performed using infrared cameras and reflective marker clusters. Correlation between motion analysis data and patient reported function was investigate. Whilst multiple gait parameters correlated with KOS score preoperatively, there was no correlation after TKR. Three preoperative measurements correlated with the improvement in score a subject achieved following surgery: These were preoperative rate of extension in swing, total range of flexion from heel strike and time point of maximum stance extension. Our results suggest that whilst preoperatively there is a close relationship between knee biomechanical function and patient reported function, after TKR factors other than biomechanical function determine patient outcomes.
Cervical spine collars are applied in trauma situations to immobilise patients' cervical spines. Whilst movement of the cervical spine following the application of a collar has been well documented, the movement in the cervical spine The clinical authors have been shown two different techniques on how to apply the C-spine collars in their Advanced Life Support Training (ATLS). One technique is the same as that recommended by the Laerdal Company (Laerdal Medical Ltd, Kent) that manufactures the cervical spine collar that we looked at. The other technique was refined by a Neurosurgeon with an interest in pre-hospital care. In both techniques the subjects' head is immobilised by an assistant whilst the collar is applied. We aimed to quantify which of these techniques caused the least movement to the cervical spine. There is no evidence in the literature quantifying how much movement in any plane in the unstable cervical spine is safe. Therefore, we worked on the principle: the less movement the better. The Qualisys Motion Capture System (Qualisys AB, Gothenburg, Sweden) was used to create an environment that would measure movement on the neck during collar application. This system consisted of cameras that were pre-positioned in a set order determined by trial and error initially. These cameras captured reflected infra-red light from markers placed on anatomically defined points on the subject's body. As the position of the cameras was fixed then as the patients moved the markers through space, a software package could deduce the relative movement of the markers to each camera with 6 degrees of freedom (6DOF). Six healthy volunteers (3 M, 3 F; age 21-29) with no prior neck injuries acted as subjects. The collar was always applied by the same person. Each technique was used 3 times on each subject. To replicate the clinical situation another volunteer would hold the head for each test. The movements we measured were along the x, y, and z axes, thus acting as an approximation to flexion, extension and rotation occurring at the C-spine during collar application. The average movement in each axis (x, y and z) was 8 degrees, 8 degrees and 5 degrees respectively for both techniques. No further data analysis was attempted on this small data set. However this pilot study shows that our method enables researchers to reproducibly collect data about cervical spine movement whilst applying a cervical collar.