Vol. 103-B, Issue 2 | Pages 305 - 308
1 Feb 2021
Howell M Rae FJ Khan A Holt G

Aims

Iliopsoas pathology is a relatively uncommon cause of pain following total hip arthroplasty (THA), typically presenting with symptoms of groin pain on active flexion and/or extension of the hip. A variety of conservative and surgical treatment options have been reported. In this retrospective cohort study, we report the incidence of iliopsoas pathology and treatment outcomes.

Methods

A retrospective review of 1,000 patients who underwent THA over a five-year period was conducted, to determine the incidence of patients diagnosed with iliopsoas pathology. Outcome following non-surgical and surgical management was assessed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 6 - 6
1 Jul 2020
Hall A Holt G
Full Access

Background

National hip fracture programmes are becoming widespread, but this practice is nascent and varied. The Scottish Hip Fracture Audit (SHFA) was an early adopter of this strategy and is credited with substantial systemic improvements in quality and outcomes.

Objectives

To provide evidence and incentive to clinicians and administrators to adopt successful improvement strategies, and to facilitate data-driven change hip fracture care.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 154 - 159
1 Feb 2015
Halai M Gupta S Gilmour A Bharadwaj R Khan A Holt G

We evaluated an operative technique, described by the Exeter Hip Unit, to assist accurate introduction of the femoral component. We assessed whether it led to a reduction in the rate of leg-length discrepancy after total hip arthroplasty (THA).

A total of 100 patients undergoing THA were studied retrospectively; 50 were undertaken using the test method and 50 using conventional methods as a control group. The groups were matched with respect to patient demographics and the grade of surgeon. Three observers measured the depth of placement of the femoral component on post-operative radiographs and measured the length of the legs.

There was a strong correlation between the depth of insertion of the femoral component and the templated depth in the test group (R = 0.92), suggesting accuracy of the technique. The mean leg-length discrepancy was 5.1 mm (0.6 to 21.4) pre-operatively and 1.3 mm (0.2 to 9.3) post-operatively. There was no difference between Consultants and Registrars as primary surgeons. Agreement between the templated and post-operative depth of insertion was associated with reduced post-operative leg-length discrepancy. The intra-class coefficient was R ≥ 0.88 for all measurements, indicating high observer agreement. The post-operative leg-length discrepancy was significantly lower in the test group (1.3 mm) compared with the control group (6.3 mm, p < 0.001).

The Exeter technique is reproducible and leads to a lower incidence of leg-length discrepancy after THA.

Cite this article: Bone Joint J 2015;97-B:154–9.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1185 - 1191
1 Sep 2014
Middleton RG Uzoigwe CE Young PS Smith R Gosal HS Holt G

We aimed to determine whether cemented hemiarthroplasty is associated with a higher post-operative mortality and rate of re-operation when compared with uncemented hemiarthroplasty. Data on 19 669 patients, who were treated with a hemiarthroplasty following a fracture of the hip in a nine-year period from 2002 to 2011, were extracted from NHS Scotland’s acute admission database (Scottish Morbidity Record, SMR01). We investigated the rate of mortality at day 0, 1, 7, 30, 120 and one-year post-operatively using 12 case-mix variables to determine the independent effect of the method of fixation. At day 0, those with a cemented hemiarthroplasty had a higher rate of mortality (p < 0.001) compared with those with an uncemented hemiarthroplasty, equivalent to one extra death per 424 procedures. By day one this had become one extra death per 338 procedures. Increasing age and the five-year co-morbidity score were noted as independent risk factors. By day seven, the cumulative rate of mortality was less for cemented hemiarthroplasty though this did not reach significance until day 120. The rate of re-operation was significantly higher for uncemented hemiarthroplasty. Despite adjusting for 12 confounding variables, these only accounted for 15% of the observed variability.

The debate about the choice of the method of fixation for a hemiarthroplasty with respect to the rate of mortality or the risk of re-operation may be largely superfluous. Our results suggest that uncemented hemiarthroplasties may have a role to play in elderly patients with significant co-morbid disease.

Cite this article: Bone Joint J 2014;96-B:1185–91.