Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_26 | Pages 23 - 23
1 Jun 2013
Rodger M Armstrong A Hubble M Refell A Charity J Howell J Wilson M Timperley J
Full Access

The management of patients with displaced intra-capsular hip fractures is usually a hip hemiarthoplasty procedure. NICE guideline 124 published in 2011 suggested that Total Hip Replacement (THR) surgery should be considered in a sub group of patients with no cognitive impairment, who walk independently and are medically fit for a major surgical procedure.

The Royal Devon and Exeter Hospital manages approximately 600 patients every year who have sustained a fracture of neck of femur, of which approximately 90 patients fit the above criteria. Prior to the guideline less than 20% of this sub-group were treated with a THR whereas after the guideline over 50% of patients were treated with THR, performed by sub-specialist Hip surgeons. This change was achieved by active leadership, incorporation of ‘Firebreak’ lists, looking for cases, flexible use of theatre time and operating lists and the nomination of an individual senior doctor who was tasked with a mission to improve practice.

This practice is financially viable; the Trust makes over £1000 per THR for fracture. Complete outcome data at 120 days show significantly fewer patients stepping down a rung in terms of both independent living and independent walking.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 169 - 169
1 Sep 2012
Bartlett G Wilson M Whitehouse S Hubble M Gie G Timperley J Howell J
Full Access

We present 346 consecutive revision procedures for aseptic loosening with acetabular impaction bone grafting (AIBG) and a cemented polyethylene cup. Defects were contained with mesh alone. Mean follow up of 6.6 years, range 8 days-13 years. The Oxford Hip (OHS) and Harris Hip (HHS) scores were collected prospectively. Radiological definition of cup failure was either > 5mm displacement, or > 5° rotation. Cox regression analysis was performed on ten separate patient and surgical factors to determine their significance on survivorship.

Kaplan Meier survivorship at 10 years (42 cases remaining at risk) for aseptic loosening was 87% (95% confidence Interval (CI): 81.6 to 92.2) and 85.6% (95% CI: 80.3 to 90.9) for all revisions. These results are comparable to other reported series utilising AIBG. However, there were 88 cases (25%) that exceeded the radiological migration parameters, but their functional scores were not significantly different to the non-migrators: OHS p=0.273, HHS p=0.16. The latest post-operative mean OHS was 33 (SD 10.66). Female gender (p=0.039), increasing graft thickness (p=0.006) and the use of mesh (p=0.037) were significant risk factors for revision, but differing techniques in graft preparation, including artificial graft expanders (p=0.73), had no significant effect when analysed using Cox regression.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 167 - 167
1 Sep 2012
Bolland B Whitehouse S Howell J Hubble M Gie G Timperley A
Full Access

This study utilised NJR primary hip data from the 6th Annual Report to determine the rate and indication for revision between cemented, uncemented, hybrid and resurfacing prosthetic groups. Regression analysis was performed to identify the influence of gender and ASA grade on these revision rates. Validity of the data was interrogated by exploring for episodes of misclassification.

Results

We identified 2,264 misclassified episodes within the four groups (Misclassification rate 2.7% primary, 4.3% revision procedures). Analysis was performed using the “reclassified dataset”.

The Kaplan-Meier revision rates at 3 years were 0.9% (95%CI: 0.8%-1.0%) for cemented prostheses, 1.9% (95%CI: 1.8%-2.0%) for uncemented hips, 1.2% (95%CI: 1.0%-1.4%) for hybrids and 3.0%, (95%CI: 2.7%-3.3%) in the resurfacing group. The trends in revision rates were comparable to those published in the NJR (6th Edn.) with significant differences across all groups (p< 0.0001). Revision rates in the under 55 year age group showed an identical hierarchy with cemented and hybrid arthroplasty having the lowest revision rates.

Cox Regression analysis indicated that both the prosthesis group in isolation and the interaction between prosthesis group and ASA grade significantly influenced the rate of failure (p< 0.001).

Indications for revision showed significant differences in rates for, pain, aseptic loosening, dislocation and malalignment between prosthesis types (p< 0.001). The indications including Aseptic loosening, pain, malalignment and dislocation all demonstrated similar trends in revision rates between prosthetic groups with cemented hips having the lowest rates followed by ascending rates for hybrid, uncemented and resurfacing groups. The exception being dislocation with resurfacings having the lowest revision rates.

Discussion

This study provides important baseline revision rates by indication for each prosthetic group from which future comparisons can be made. Areas of misclassification within the NJR dataset have been reported back for future annual analysis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 168 - 168
1 Sep 2012
Bolland B Howell J Hubble M Timperley A Gie G Ling R
Full Access

Background

Since 1991 to 2008 approximately 800,000 Exeter stems have been sold worldwide with 80 reported cases of fracture (neck or stem). This study aimed to determine factors predisposing to fracture.

Method

Clinical, surgical, radiological and retrieval data was collated from Stryker Benoist-Girard and Exeter research databases. Risk factors associated with fracture were categorised to patient related (weight and activity levels), surgical related (poor medial support, component size, placement) and implant related (+ head).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 62 - 62
1 May 2012
Wilson M Hubble M Howell J Gie G Timperley J Crawford R
Full Access

Impaction bone grafting (IBG) of the acetabulum in cemented primary total hip replacement is a useful technique in the management of acetabular deficiencies. It has the capacity to restore anatomy and bone stock with good long-term outcome. We present 125 consecutive cases of IBG with a cemented polyethylene component. All patients who received full IBG of the acetabulum in primary cemented Exeter total hip replacements and who underwent surgery between August 1995 and August 2003 were identified. All operative and follow-up data was collected prospectively and no patients were lost to follow-up. All patients underwent pre-operative and regular post-operative hip scores with the Harris, Oxford and the modified Charnley scoring systems. Data on indication, surgical technique, socket position and migration and revision was reviewed at a mean follow-up of 7.6 (range 5 to13.4) years.

Between August 1995 and August 2003, 113 patients (85 females) with an average age of 67.8 (range 22.9–99.2) years underwent 125 primary Exeter cemented total hip replacements with IBG of acetabular defects. Acetabular defects were classified according to the AAOS classification as cavitatory in 62 hips and as segmental, requiring application of a rim mesh prior to IBG, in 63 hips. Life tables were constructed demonstrating 86.4% survival of the acetabular component at 13.4 years with revision for any reason as the endpoint and 89.3% survival with revision for aseptic loosening as the endpoint. Of the seven patients who underwent revision for aseptic loosening, all had pre-operative segmental acetabular defects requiring application of a rim mesh. No patient who underwent IBG for a cavitatory defect required revision surgery for aseptic loosening. Survival of the Exeter cemented femoral component was 100% at 13.4 years with revision for aseptic loosening as the endpoint. There were 11 radiographic failures of the acetabular component, which have not been revised at latest review. One of these is symptomatic but not fit for revision surgery, two were asymptomatic at time of death and eight are asymptomatic but under review.

This is the largest series of IBG in the acetabulum in cemented primary THR. Our results suggest that the medium term survival of this technique is good, particularly when used for cavitatory defects. Although there were radiographic failures, these are largely asymptomatic and may not require revision.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 219 - 219
1 May 2012
Hubble M Mounsey E Williams D Crawford R Howell J
Full Access

The cement in cement technique for revision total hip arthroplasty (THA) has shown good results in selected cases. However, results of its use in the revision of hemiarthroplasty to THA has not been previously reported.

Between May 1994 and May 2007 28 (20 Thompson's and 8 Exeter bipolar) hip hemiarthroplasties were revised to THA in 28 patients using the cement in cement technique. All had an Exeter stem inserted at the time of revision. Clinical and operative data were collected prospectively. Clinical evaluation was by the Charnley, Harris and Oxford. Hip scores and radiographs were analysed post-operatively and at latest follow up.

The mean age at time of hemiarthroplasty revision was 80 (35 to 93) years. The reason for revision was acetabular erosion in 12 (43%), recurrent dislocation in eight (29%), aseptic stem loosening in four (14%), periprosthetic fracture in two (7%) and infection in a further two (7%) patients. No patient has been lost to follow up. Three patients died within three months of surgery. The mean follow up of the remainder was 50 (16 to 119) months. Survivorship with revision of the femoral stem for aseptic loosening as the endpoint was 100%. Three cases (11%) have since undergone further revision, one for recurrent dislocation, one for infection, and one for periprosthetic fracture.

The cement in cement technique can be successfully applied to revision of hip hemiarthroplasty to THA. It has a number of advantages in this elderly population including minimising bone loss, blood loss and operative time.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 88 - 88
1 May 2012
Hubble M Blake S Howell J Crawford R Timperley J Gie G
Full Access

Removal of well-fixed cement at the time of revision THA for sepsis is time consuming and risks bone stock loss, femoral perforation or fracture. We report our experience of two-stage revision for infection in a series of cases in which we have retained well-fixed femoral cement.

All patients underwent two-stage revision for infection. At the first stage the prostheses and acetabular cement were removed but when the femoral cement mantle demonstrated good osseo-integration it was left in-situ. Following Girdlestone excision arthroplasty (GEA), patients received local antibiotics delivered by cement spacers, as well as systemic antibiotics. At the second stage the existing cement mantle was reamed, washed and dried and then a femoral component was cemented into the old mantle.

Sixteen patients (M:F 5:11) had at least three years follow-up (mean 80 months – range 43 to 91). One patient died of an unrelated cause at 53 months. Recurrence of infection was not suspected in this case. The mean time to first stage revision was 57 months (3 to 155). The mean time between first and second stages was nine months (1 to 35). Organisms were identified in 14 (87.5%) cases (5 Staphylococcus Aureas, 4 Group B Streptococcus, 2 Coagulase negative Staphylococcus, 2 Enterococcus Faecalis, 1 Escheria Coli). At second stage, five (31.2%) acetabulae were uncemented and 11 (68.8%) were cemented. There were two complications; one patient dislocated 41 days post-operatively and a second patient required an acetabular revision at 44 days for failure of fixation. No evidence of infection was found at re-revision. One patient (1/16, 7%) has been re-revised for recurrent infection. Currently no other patients are suspected of having a recurrence of infection (93%).

Retention of a well-fixed femoral cement mantle during two-stage revision for infection and subsequent cement-in-cement reconstruction appears safe with a success rate of 93%. Advantages include a shorter operating time, reduced loss of bone stock, improved component fixation and a technically easier second stage procedure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 125 - 125
1 Feb 2012
Charity J Tsiridis E Gie G Timperley J Hubble M Howell J
Full Access

Restoration of an anatomical hip centre frequently requires limb lengthening, which increases the risk of nerve injury in the treatment of Crowe 4 DDH. The objective was to perform a prospective evaluation of SDTSO with Cemented Exeter Femoral Component.

15 female patients (18 hips – 3 bilateral) with a mean age at time of operation of 51 years were followed-up for a mean of 77 months (11 to 133). 16 cemented and 2 uncemented acetabular components were implanted. Exeter cemented DDH stems were used in all cases. No patient was lost to follow-up.

Charnley-d'Aubigné-Postel scores for pain, function and range of movement were improved from a mean of 2, 2, 3 to 5, 4, 5 respectively. One osteotomy failed to unite at 14 months and was revised successfully. Clinical healing was achieved at a mean of 6 months and radiological at a mean of 9 months. The mean length of the excised segment was 3cm and the mean true limb lengthening was 2cm. A 3.5mm DCP plate with unicortical screws was used to reduce the osteotomy, and intramedullary autografting was performed in all cases. Mean subsidence was 1mm and no stem was found loose at the latest follow-up. No sciatic nerve palsy was observed and no dislocation.

Cemented Exeter femoral components perform well in the treatment of Crowe IV DDH with SDTSO. Transverse osteotomy is necessary to achieve derotation and reduction can be maintained with a DCP plate. Intramedullary autografting prevents cement interposition at the osteotomy site.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 143 - 143
1 Feb 2012
Lewthwaite S Squires B Gie G Timperley J Howell J Hubble M Ling R
Full Access

Aim

The aim of this study was to determine the medium term survivorship and function of the Exeter Universal Hip Replacement when used in younger patients, a group that is deemed to place high demands on their arthroplasties. Since 1988 The Exeter Hip Research Unit has prospectively gathered data on all patients who have had total hip replacements at the Princess Elizabeth Orthopaedic Hospital. There were 130 Exeter Universal total hip replacements (THR) in 107 patients who were 50 years or younger at the time of surgery and whose surgery was performed at least 10 years before. Mean age at surgery was 42 years (range 17-50 years.) Six patients who had 7 THRs had died, leaving 123 THRs for review. Patients were reviewed at an average of 12.5 years (range 10-17 years). No patient was lost to follow-up.

Results

At review, 12 hips had been revised. Of these, 9 were for aseptic loosening of the acetabular component and one cup was revised for focal lysis and pain. One hip was revised for recurrent dislocation. One femoral component required revision in 1 case of infection. Radiographs showed that a further 11 (10%) of the remaining acetabular prostheses were loose but that no femoral components were loose. Survivorship of stem and cup from all causes was 94%, at an average of 12.5 years. Survivorship of stem only from all causes was 99% and from aseptic loosening was 100%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 59 - 59
1 Feb 2012
Carrington N Sierra R Hubble M Gie G Ling R Howell J
Full Access

Purpose

We describe an update of our experience with the implantation of the first 325 Exeter Universal hips. The fate of every implant is known.

Methods and results

The first 325 Exeter Universal stems (309 patients) were inserted between March 1988 and February 1990. The procedures were undertaken by surgeons of widely differing experience. Clinical and radiological review was performed at a mean of 15.7 years. At last review 185 patients had died (191 hips). 103 hips remain in situ. Survivorship at 17 years with revision for femoral component aseptic loosening was 100% (95% CI 97 to 100), with revision for acetabular component aseptic loosening was 90.4% (95% CI 83.1 to 94.7) and with any re-operation as the endpoint was 81.1% (95% CI 72.5 to 89.7). 12 patients (12 hips) were not able to attend for review due to infirmity or emigration, and scores were obtained by phone (x-rays were obtained in 4 patients). Mean D'Aubigné and Postel scores (Charnley modification) at review were 5.4 for pain and 4.8 for function. The mean Oxford score was 21.6 +/− 9.8 and the mean Harris score 71.7 +/− 19.7. On radiological review there were no femoral component failures. Three sockets (2.9%) were loose as demonstrated by migration or change in orientation (two patients were asymptomatic) and 5 sockets (4.9%) had radiolucent lines in all 3 zones but no migration. There are two patients awaiting socket revision.