Computer aided Total Hip Arthroplasty (THA) surgery is known to improve implantation precision, but clinical trials have failed to demonstrate an improvement in survivorship or patient reported outcome measures (PROMs). Our aim was to compare the risk of revision, PROMs and satisfaction rates between computer guided and THA implanted without computer guidance. We used the National Joint Registry dataset and linked PROMs data. Our sample included THAs implanted for osteoarthritis using cementless acetabular components from a single manufacturer (cementless and hybrid). An additional analysis was performed limiting the sample size to THAs using cementless stems (fully cementless). The primary endpoint was revision (of any component) for any reason. Kaplan Meier survivorship analysis and an adjusted Cox Proportional Hazards model were used. 41683 non computer guided, and 871 (2%) computer guided cases were included in our cementless and hybrid analysis. 943 revisions were recorded in the non-guided and 7 in the computer guided group (adjusted Log-rank test, p= 0.028). Cumulative revision rate at 10 years was 3.88% (95%CI: 3.59 – 4.18) and 1.06% (95%CI: 0.45 – 2.76) respectively. Cox Proportional Hazards adjusted HR: 0.45 (95%CI: 0.21 – 0.96, p=0.038). In the fully cementless group, cumulative revision rate at 10 years was 3.99% (95%CI: 3.62 – 4.38) and 1.20% (95%CI: 0.52 – 3.12) respectively. Cox Proportional Hazards adjusted HR: 0.47 (95%CI: 0.22 – 1.01, p=0.053). There was no statistically significant difference in the 6-month Oxford Hip Score, EQ-5D, EQ-VAS and success rates. Patient Satisfaction (single-item satisfaction outcome measure) was improved in the computer guided group but this finding was limited by a reduced number of responses. In this single manufacturer acetabular component analysis, the use of computer guided surgery was associated with a significant reduction in the early risk of revision. Causality cannot be inferred in view of the observational nature of the study, and further database and prospective studies are recommended to validate these findings.
The presence of pseudotumours, which are soft-tissue masses relating to the hip, after metal-on-metal hip resurfacing arthroplasty has been associated with elevated levels of metal ions in serum, suggesting that pseudotumours occur when there is increased wear. We aimed to quantify the wear in vivo of implants revised for pseudotumours (eight) and of a control group of implants (22) revised for other reasons of failure. We found that the implant group with pseudotumours had a significantly higher rate of median linear wear of the femoral component at 8.1 μm/year (2.75 to 25.4) than the 1.79 μm/year (0.82 to 4.15; p = 0.002) of the non-pseudotumour group. For the acetabular component a significantly higher rate of median linear wear of 7.36 μm/year (1.61 to 24.9) was observed in the pseudotumour group compared with 1.28 μm/year (0.81 to 3.33, p = 0.001) in the other group. Wear of the acetabular component in the pseudotumour group always involved the edge of the implant, indicating that edge-loading had occurred. Our findings are the first direct evidence that pseudotumour is associated with increased wear at the metal-on-metal articulation. Furthermore, edge-loading with the loss of fluid-film lubrication may be an important mechanism of generation of wear in patients with a pseudotumour.
Second-generation metal-on-metal bearings were introduced as a response to the considerable incidence of wear-induced failures associated with conventional replacements, especially in young patients. We present the results at ten years of a consecutive series of patients treated using a metal-on-metal hip resurfacing. A distinct feature of the bearings used in our series was that they had been subjected to double-heat treatments during the post-casting phase of their manufacture. In the past these bearings had not been subjected to thermal treatments, making this a unique metal-on-metal bearing which had not been used before in clinical practice. We report the outcome of 184 consecutive hips (160 patients) treated using a hybrid-fixed metal-on-metal hip resurfacing during 1996. Patients were invited for a clinicoradiological follow-up at a minimum of ten years. The Oxford hip score and anteroposterior and lateral radiographs were obtained. The mean age at operation was 54 years (21 to 75). A series of 107 consecutive hips (99 patients) who received the same prosthesis, but subjected to a single thermal treatment after being cast, between March 1994 and December 1995, were used as a control group for comparison. In the 1994 to 1995 group seven patients (seven hips) died from unrelated causes and there were four revisions (4%) for osteolysis and aseptic loosening. In the 1996 group nine patients died at a mean of 6.9 years after operation because of unrelated causes. There were 30 revisions (16%) at a mean of 7.3 years (1.2 to 10.9), one for infection at 1.2 years and 29 for osteolysis and aseptic loosening. Furthermore, in the latter group there were radiological signs of failure in 27 (24%) of the 111 surviving hips. The magnitude of the problem of osteolysis and aseptic loosening in the 1996 cohort did not become obvious until five years after the operation. Our results indicate that double-heat treatments of metal-on-metal bearings can lead to an increased incidence of wear-induced osteolysis.