There is no consensus on the benefit of arthroscopically
assisted reduction of the articular surface combined with fixation
using a volar locking plate for the treatment of intra-articular
distal radial fractures. In this study we compared the functional
and radiographic outcomes of fluoroscopically and arthroscopically
guided reduction of these fractures. Between February 2009 and May 2013, 74 patients with unilateral
unstable intra-articular distal radial fractures were randomised
equally into the two groups for treatment. The mean age of these
74 patients was 64 years (24 to 92). We compared functional outcomes
including active range of movement of the wrist, grip strength and Disabilities
of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic
outcomes that included gap, step, radial inclination, volar angulation
and ulnar variance. There were no significant differences between the techniques
with regard to functional outcomes or radiographic parameters. The
mean gap and step in the fluoroscopic and arthroscopic groups were
comparable at 0.9 mm (standard deviation Arthroscopic reduction conferred no advantage over conventional
fluoroscopic guidance in achieving anatomical reduction of intra-articular
distal radial fractures when using a volar locking plate. Cite this article:
We report the case of a 12-year-old boy with flexion loss in the left elbow caused by deficient of the concavity corresponding to the coronoid fossa in the distal humerus. The range of motion (ROM) was 15°/100°, and pain was induced by passive terminal flexion. Plain radiographs revealed complete epiphyseal closure, and computed tomography (CT) revealed a flat anterior surface of the distal humerus; the coronoid fossa was absent. Then, the bony morphometric contour was surgically recreated using a navigation system and a three-dimensional elbow joint model. A three-dimensional model of the elbow joint was made preoperatively and the model comprising the distal humerus was milled so that elbow flexion flexion of more than 140° could be achieved against the proximal ulna and radius. Navigation-assisted surgery (contouring arthroplasty) was performed using CT data from this milled three-dimensional model. Subsequently, an intraoperative passive elbow flexion of 135° was obtained. However, active elbow flexion was still inadequate one year after operation, and a triceps lengthening procedure was performed. At the final follow-up one year after triceps lengthening, a considerable improvement in flexion was observed with a ROM of −12°/125°. Plain radiographs revealed no signs of degenerative change, and CT revealed the formation of the radial and coronoid fossae on the anterior surface of the distal humerus. Navigation-assisted surgery for deformity of the distal humerus based on a contoured three-dimensional model is extremely effective as it facilitates evaluation of the bony morphometry of the distal humerus. It is particularly useful as an indicator for milling the actual bone when a model of the mirror image of the unaffected side cannot be applied to the affected side as observed in our case.
We prospectively examined the physical and imaging findings, including MRI, of 23 patients with spontaneous osteonecrosis of the knee after obtaining informed consent to acquire tissue specimens at surgery. There were four men and 19 women, with a mean age of 67.5 years (58 to 77). Plain radiographs were designated as stages 1, 2, 3 or 4 according to the classification of Koshino. Five knees were classified as stage 1, five as stage 2, seven as stage 3 and six as stage 4. The histological specimens were stained with haematoxylin and eosin and tetrachrome. In the early stages of the condition, a subchondral fracture was noted in the absence of any features of osteonecrosis, whereas in advanced stages, osteonecrotic lesions were confined to the area distal to the site of the fracture which showed impaired healing. In such cases, formation of cartilage and fibrous tissue, occurred indicating delayed or nonunion. These findings strongly suggest that the histopathology at each stage of spontaneous osteonecrosis is characterised by different types of repair reaction for subchondral fractures.
This study examined the inhibitory effects of anti-TNF-a antibody (anti-TNF) and a new bisphosphonate (TRK-530) on peri-implant oseteolysis in a rat model with continuous infusion of polyethylene particles. TRK-530 is a novel synthetic bisphophonate to have a direct effect on osteoclastic bone resorption as well as suppressive effects on bone resorbing cytokines from macrophages.
Between 1993 and 1999, we treated ten patients with comminuted fractures of the olecranon by multiple tension-band wiring and a graft from the iliac crest. Their mean age was 35 years (19 to 56). The mean follow-up was for 28.5 months (15 to 46) and the mean time to union of the fractures was four months (3 to 7). No patient reported difficulties with activities of daily living or symptoms of instability of the elbow. The mean flexion was to 135° (125 to 145) with a mean flexion contracture of 15° (10 to 30). The mean pronation was 70° (60 to 80) and mean supination 79° (70 to 90). Only three patients had mild pain and loss of strength. Five patients had excellent and five good results with a mean Broberg and Morrey index score of 94.5 points (84 to 100). Our results compare favourably with those previously reported and the technique is thought to be a practical alternative to plate fixation in fractures with extreme comminution.