The anatomic abnormalities are observed in developmental dysplasia of the hip (DDH) and it is challenging to perform the total hip arthroplasty (THA) for some DDH patients. If acetabular cup was placed at the original acetabular position in patients with high hip dislocation, it may be difficult to perform reduction of hip prosthesis because of soft tissue contracture. The procedures resolving this problem were to use femoral shortening osteotomy, or to place the acetabular cup at a higher cup position than the original hip center. Femoral shortening osteotomy has some concerns about its complicated procedure, time consuming, and risk of non-union. Conversely, implantation of the acetabular cup at the higher cup position may eliminate these shortcomings and this procedure is considered to be preferred if possible. However, the criteria of cases without femoral shortening osteotomy are not clear. In this study, we retrospectively analysed the clinical outcomes of patients performed THAs for high hip dislocation, and clarified the adaptation of THA with or without femoral shortening osteotomy. We included a total of 65 hip joints from 57 patients who underwent primary THA using Modulus stem for high hip dislocation from November 2007 to December 2015 at our institution. The mean follow up period was 5.2 years (2 – 10 years). The mean age at surgery was 65.4 years (Table 1). Thirty seven hips were classified as Crowe III, and twenty eight hips as Crowe IV based on Crowe classification. We classified patients into two groups based on the use of femoral osteotomy. Then, we compared the surgical time, blood loss, Japanese Orthopaedic Association (JOA) Score as clinical outcomes, preoperative position of the greater trochanter, the cup position, and complications between two groups. The position of the greater trochanter was measured the height of the tip of greater trochanter from the inter teardrop line. The cup center position was assessed by measuring the distance between the cup center and ipsilateral tear drop. Receiver operating characteristic (ROC) curves were plotted for deciding the cut-off value for the height of the greater trochanter. The cut-off value presented the maximum sensitivity and specificity was determined.Introduction
Methods
To obtain appropriate joint gap and soft tissue balance, and to correct the lower limb alignment are important factor to achieve success of total knee arthroplasty (TKA). A variety of computer-assisted navigation systems have been developed to implant the component accurately during TKA. Although, the effects of the navigation system on the joint gap and soft tissue balance are unclear. The purpose of the present study was to investigate the influence of accelerometer-based portable navigation system on the intraoperative joint gap and soft tissue balance. Between March 2014 and March 2015, 36 consecutive primary TKAs were performed using a mobile-bearing posterior stabilized (PS) TKA (Vanguard RP; Biomet) for varus osteoarthritis. Of the 36 knees, 26 knees using the accelerometer-based portable computer navigation system (KneeAlign2; OrthAlign) (N group), and 10 knees using conventional alignment guide (femur side; intramedullary rod, tibia side; extramedullary guide) (C group). The intraoperative joint gap and soft tissue balance were measured using tensor device throughout a full range of motion (0°, 30°, 45°, 60°, 90°, 120°and full flexion) at 120N of distraction force. The postoperative component coronal alignment was measured with standing anteroposterior hip-to-ankle radiographs.INTRODUCTION
METHODS
The concept of anatomical stam is fit-and-fill in the proximity of the femur and to expect wall fixation, following to reduce thigh pain and stress shielding. Although the femoral medullary form and size are different in each races. CentPillar TMZF stem (stryker ®) is anatomical stem designed based on computer-tomography of Japanese femurs. The purpose of this study was to evaluate clinical and radiographic outcomes of CentPillar TMZF stem at a mean of 3.6 years postoperatively. We asseses the results of 98 primary total hip arthroplasty (THA) performed using a CentPillar TMZF stem in 91 Japanese patients (4 males, 94 females) undergoing surgery between August 2007 and June 2011, the mean age at the time of surgery was 62.0 (41–81) years old. The Diagnosis were osteoarthritis (OA) in 91 hips, rapidly destructive coxopathy (RDC) in 4 hips, rheumatoid arthritis (RA) in 3 hips. Clinical and radiographic assessments were performed for every patient for every follow up using Japan Orthopaedic Association (JOA) Score, thigh pain, revision surgery and complications. Radiographic assessments were including stem alignment on anteroposterior radiograph, stress shielding, bone remodeling, radiolucent line, osteolysis, loosening and subsidence.INTRODUCTION
METHODS
The Taperloc Microplasty stem design was based on that of the Taperloc stem with flat tapered wedge and the distal portion of the Taperloc stem was shortened by 35mm. We report the minimum two-year follow up (mean, 26 months) of 68 primary total hip arthroplasty using the Taperloc Microplasty stem. 39 Magnum acetabular cups and 29 M2a Taper acetabular cups were inserted with metal on metal articulation. The series comprised 67 patients (20 men, 47 women) with a mean age at operation of 65 years (31 to 85). The principal diagnosis was osteosrthritis. Their mean JOA Hip Score improved significantly from 36 points preoperatively to 96 points at two-year follow up. Radiological asseement showed good bony stability in all implants. There was one case of post operative anterior dislocation. We did not see intra-operative fracture previously reported for this implant. There were no clinical and radiological complications related to MOM articulation. This short-term follow up study demonstrates that the clinical outcome of the Tapeloc Microplasty stem is comparable with that of standard Taperloc stem and other flat taper wedge stems.
Bipolar hemiarthroplasty (following BHA) have historically had poor results in patients with idiopathic osteonecrosis of femoral head (OFNH). However, most recent report have shown excellent results with new generation BHA designs that incorporate advances in bearing technology. These optimal outcomes with bipolar hemiarthroplasty will be more attractive procedure for young patients who need bone stock for future total arthroplasty. The purpose of the current study was to evaluate the clinical and radiographic finding of this procedure for the treatment of OFNH at our institution after 7-to 21years follow-up. We retrospectively reviewed a consecutive series of 29 patients (40 hips) who underwent primary bipolar hemiarthroplasty for ION (36 hips with stage III and 4 hips with stage IV) with a cementless femoral component between 1992 and 2006. Osteonecrosis was associated with corticosteroid use (23 patients), alcohol (16 patients), idiopathic (one patients). The mean follow-up duration was approximately 12 (range 7 to 21) years. Patients were evaluated according to the Japan Orthopaedic Association (JOA) hip score. We evaluate osteolysis and bone response of acetabulum or femur, and migration distance of outer head were calculated at the latest follow-up. Kaplan-Meier survivorship rate was investigated to examine implant failure rate.[Background]
[Subjects and Methods]
Modulus femoral prosthesis is a modular cementless femoral system which consists of 5 degree tapered conical stem made of a titanium alloy with 8 fins of 1mm and modular neck. Modular neck enables to control any ideal stem anteversion as a surgeon prefers. This system is considered to be useful in severe hip deformity, for example developmental dysplasia of the hip (DDH). In this study, clinical and radiographic outcomes of the Modulus femoral prosthesis were evaluated at a mean of 3.6 (2–6) years postoperatively. We assessed the results of 193 primary total hip arthroplasty using a Modulus femoral prosthesis in 169 patients (15 males, 154 females) undergoing surgery between September 2007 and December 2011. The mean age at the time of surgery was 65.6 (31–86) years old. The diagnoses were osteoarthritis (OA) in 178 hips (including 167 hips of DDH), rapidly destructive coxopathy (RDC) in 6 hips, rheumatoid arthritis (RA) in 6 hips, osteonecrosis in 2 hips, and subchondral insufficiency fracture in one hip. Clinical outcomes were assessed using Japan Orthopedic Association (JOA) hip scores and complications. Radiographic assessments were including stem alignment, bone on-growth, cortical hypertrophy, stress shielding and stem subsidence. 43.8 points of the preoperative mean JOA score was significantly improved to 93.1 points postoperatively. In one case intraoperative femoral fracture was occurred. One dislocation had occurred and thigh pain was observed in one hip. No revision surgery was required. In 192 hips of 193 hips (99.5%), stem was implanted in neutral position (within ±2 degrees). Bone on-growth was observed in all cases (94.3% in zone 3; 73.1% in zone 5; 30.6% in zone 2; 22.3% in zone 6). Cortical hypertrophy was observed in 66 hips (34.2%) at zone 3 and 5. Reduction of bone density due to stress shielding was observed (1st degree was 58.5%; 2nd degree was 29.5%; 3rd degree was 11.9%; 4th degree was 0%). In 22 cases (11.4%), more than 2mm of stem subsidence was observed, however the subsidence was stopped within 6 months in all cases. Modulus femoral prosthesis showed good clinical results and radiographic findings up to 6 years postoperatively.
Metal on metal total hip arthroplasty (MoM THA) provides the potential improvement in articular wear. However, several adverse events including pseudotumor had been reported. Magnetic resonance imaging (MRI) was considered to be the proposal tool for detection of pseudotumor after MoM THA. In this study, we performed the screening of pseudotumor after MoM THA using the MRI. We studied 43 patients with M2a Magnum® (Biomet) and 34 patients with M2a Taper® (Biomet) of MoM THA from December 2009 to December 2011 with follow-up of 2.5 years (2.0–4.0 years) after surgery. MRI assessments were performed at a mean of 2.1 years postoperatively. Pseudotumor findings were graded using Anderson classification (Skeletal Radiol, 2011: 40; 303). Age, sex, height, weight, Harris Hip Score, EQ5D satisfaction score, UCLA activity score, and blood metal ion levels were evaluated. The prevalence of pseudotumor was 27.2%; 56 normal (Type A), 13 mild (C1), 8 moderate (C2) and none were graded severe (C3). Weight and BMI in the mild group was significantly higher than those in normal. There was no significant difference in age, sex and height among these groups. With regard to Harris Hip score, pain and ROM score in moderate group was significantly lower than that in normal and mild group. EQ5D satisfaction score and UCLA activity score showed not significant differences among groups. 3.01±3.32 μg/L of blood cobalt ion levels in the moderate groups was significantly higher than 0.97±0.64 μg/L in normal group. Blood cobalt ion levels of 1 mild and 2 moderate were over the threshold of 7 μg/L. These patients were implanted with M2a Taper, not M2a Magnum. 14% of the prevalence in the patients with M2a Magnum was significantly lower than 41% in the patients with M2a Taper. No revision surgeries were required. The patients with no pseudotumor did not show the increase of blood metal ion. Contrarily, several patients showed the increase of blood metal ion in case of detecting pseudotumor. MRI assessments were useful for screening of pseudotumor after MoM THA and blood metal ion should be investigated for patients with mild and moderate pseudotumor in MoM THA.
Metal on metal total hip arthroplasty provides the potential improvement in articular wear and the use of large-diameter femoral heads following the prospect for reduction in the risk of dislocation. The purpose of this study was to compare the clinical and radiographic outcomes as well as serum metal ion level between the two different component designs with small and large femoral heads in metal on metal total hip arthroplasty. We studied 39 patients with large head (Magnum®, Biomet; cup size minus 6 mm) and 37 patients with small head (M2a taper®, Biomet; 28 or 32 mm head) of metal on metal total hip arthroplasty between December 2009 to October 2011 with follow-up of 2.1 years (1.0–3.3 years) after surgery. Harris Hip Score, UCLA activity score, EQ-5D, radiographic assessment, and serum cobalt and chromium ion levels were evaluated. Harris Hip Score, UCLA activity score, and EQ-5D were improved after surgery in small and large head groups, however, no significant differences were observed between both groups. Cup inclination was below 50 degree in all prosthesis. No loosening and no osteolysis were observed. Cobalt and chromium ion was not detected before surgery; however, metal ion levels of both groups were increased after surgery in time dependent manner. There was no significant difference between two groups at one year after surgery. One patient in each group showed the increase of cobalt ion level over 7 ppb (15.4 ppb, 12.9 ppb) without any clinical symptom including pain. Cup inclination was 29 degree in both patients and cup anteversion was 38 and 41 degree, respectively. There was no significant difference of ion levels between both groups. No dislocation was observed in large head group while one dislocation occurred in small head group. No patients required the revision surgery. This metal on metal component, especially with large femoral heads, showed the good clinical results at the maximum follow up of 3.3 year after surgery. However, the ion level of two patients increased over 7 ppb and longer follow-up will be needed.
Alendronate is a potent inhibitor of bone resorptive activity, and has been shown to prevent and restore periprosthetic osteolysis in experimental models. A preliminary study was conducted to examine clinical usefulness of a lendronate treatment. Twenty-five patients (27 hips) with radiological evidence of osteolysis after cemented total hip arthroplasty were included. Of these, 14 patients (15 hips) were administered 5 mg of alendronate daily (alendronate group), and 11 patients (12 hips) did not receive alendronate treatment (control group). The subjects were followed up for 12 months, using radiological examinations and biochemical markers. The radiological analysis was evaluated blindly by 2 joint arthroplasty experts, each with more than 10 years of experience, without knowledge of alendronate administration. In the alendronate group, average serum bone alkaline phosphatase and urinary excretion of the N-telopep-tide of type I collagen values decreased from the baseline values after administration of alendronate, to 71% and 76% of baseline at the 3-month examination, and 57% and 62% at the 1-year examination, respectively. In the control group, expansion of osteolysis was found in 5 hips (42%) and no hip showed restoration of osteolysis. In the alendronate group, expansion of osteolysiswas found in 2 hips (13%), and restoration of osteolysis was found in 5 hips (33%). There was a statistically significant difference in ratio of hips with osteolysis restoration between the 2 groups (p<
0.05). In the alendronate group, there was no significant difference in age, average linear wear rate of polyethylene, and the biochemical markers, between the hips with and without diminishment of osteolysis.