Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 597 - 603
1 May 2014
Nomura T Naito M Nakamura Y Ida T Kuroda D Kobayashi T Sakamoto T Seo H

Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°).

Measurements using Widmer’s method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001).

This study has shown that Widmer’s method is the best for evaluating the anteversion of the acetabular component on plain radiographs.

Cite this article: Bone Joint J 2014; 96-B:597–603.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 422 - 423
1 Nov 2011
Kamada S Naito M Nakamura Y Teratani T Takeyama A Karashima H Kinoshita K Kashima N Tanaka Y Ida K Kuroda D
Full Access

The Mayo-Stem is short and tapered in the anteroposterior and mediolateral directions, designed to enhance early fixation through multiple point contact in the proximal medullary cavity. The purpose of this study was to investigate the clinical and radiographic results of total hip arthroplasty (THA) using this short stem in younger patients.

A total of 97 cementless THAs using this short stem were investigated. The length of the stem used ranged from 90mm to 110 mm. The average age of the patients at the time of surgery was 50.9 years (33–64 years). The average follow-up period was 64 months (38–108 months).

The Harris hip score was used for clinical evaluation. The valgus angles of the stems and the changes in radiographic findings around the stems after surgery were investigated on the AP radiographs of hip.

The average Harris hip score was 52.0 points pre-operatively and 93.9 points at the latest follow-up. An intraoperative femoral fissure fracture of the proximal femur occurred in 15 hips (15.4%), which were treated by circlage wires. The average valgus angle of the stem was 3.5° (range: −6°–18°). The development of bone trabeculae was seen around the curve of the stem (Gruen zones 3 and 5) in 79.4 % of hips one year after surgery. A radiolucent line was found on the lateral side of the stem (Gruen zones 1, 2, and 3) in 13.4 % of hips, which occurred in connection with the development of bone trabeculae. Subsidence of the stems (> 2mm) was seen in three hips in which intraoperative femoral fissure fracture had not occurred. These hips did not get the development of bone trabeculae. In two hips of the three hips, the valgus angles of the stems were 15° and 17° respectively. In the case of the third hip, the stem was small to the proximal femur.

Overall the clinical result of THA using a short-stem was basically gratifying.

The development of bone trabeculae, the stem size to the proximal femur and the stem position were important factors for the fixation of stem. Intraoperative fissure fracture treated by circlage wires and radiolucent lines with the development of bone trabeculae did not affect the fixation of stem.