Recent years have witnessed a paradigm shift in the assessment of outcome in spine surgery, with patient-centred questionnaires replacing traditional surgeon-based assessments. The assessment of “complications” — loosely defined as new/unexpected problems arising as a result of surgery — has not enjoyed this same enlightened approach. Patients with lumbar degenerative disorders operated with the goal of pain relief, completed a questionnaire 1 year post-operatively enquiring about complications arising as a consequence of their operation. They rated the bothersomeness of any such complications on a 5-point adjectival scale. Global outcome of surgery and satisfaction were rated on 5-point Likert scales.Background
Methods
Fracture of a pedicle is a rare complication of spinal instrumentation using pedicular screws, but it can lead to instability and pain and may necessitate extension of the fusion. Osteosynthesis of the fractured pedicle by cerclage-wire fixation and augmentation of the screw fixation by vertebroplasty or temporary elongation of the fixation, allows stabilisation without sacrifice of the adjacent healthy segment. We describe three patients who developed a fracture of the pedicle in the most caudal instrumented vertebra early after lumbar spinal fusion. During revision surgery the pedicles were reduced and secured by a soft cerclage wire bilaterally. Fusion was obtained at the site of the primary instrumentation and healing of the pedicles was achieved. Cerclage wiring of the fractured pedicle seems to be safe and avoids permanent extension of the fusion without the sacrifice of an otherwise healthy segment.
In a prospective observational study we compared the two-year outcome of lumbar fusion by a simple technique using translaminar screws (n = 57) with a more extensive method using transforaminal lumbar interbody fusion and pedicular screw fixation (n = 63) in consecutive patients with degenerative disease of the lumbar spine. Outcome was assessed using the validated multidimensional Core Outcome Measures Index. Blood loss and operating time were significantly lower in the translaminar screw group (p <
0.01). The complication rates were similar in each group (2% to 4%). In all, 91% of the patients returned their questionnaire at two-years. The groups did not differ in Core Outcome Measures Index score reduction, 3.6 ( The two fusion techniques differed markedly in their extent and the cost of the implants, but were associated with almost identical patient-orientated outcomes. Extensive three-point stabilisation is not always required to achieve satisfactory patient-orientated results at two years.