Chondral defects in the knee have cartilage biomechanical differences due to defect size and orientation. This study examines how the tibiofemoral contact pressure is affected by increasing full-thickness chondral defect size on the medial and lateral condyle at full extension. Isolated full-thickness, square chondral defects increasing from 0.09cm2 to 1.0cm2 were created sequentially on the medial and lateral femoral condyles of six human cadaveric knees with intact ligaments and menisci. Chondral defects were created 1.0cm from the femoral notch posteriorly. The knees were fixed to a uniaxial load frame and loaded from 0N to 600N at full extension. Contact pressures between the femoral and tibial condyles were measured using pressure mapping sensors. The peak contact pressure was defined as the highest value in the 2.54mm2 area around the defect. The location of the peak contact pressure was determined relative to the centre of the defect. Peak contact pressure was significantly different between (4.30MPa) 0.09cm2 and (6.91MPa) 1.0cm2 defects (p=0.04) on the medial condyle. On the lateral condyle, post-hoc analysis showed differences in contact pressures between (3.63MPa) 0.09cm2 and (5.81MPa) 1.0cm2 defect sizes (p=0.02). The location of the stress point shifted from being posteromedial (67% of knees) to anterolateral (83%) after reaching a 0.49cm2 defect size (p < 0.01) in the medial condyle. Conversely, the location of the peak contact pressure point moved from being anterolateral (50%) to a posterolateral (67%) location in defect sizes greater than 0.49cm2 (p < 0.01). Changes in contact area redistribution and cartilage stress from 0.49cm2 to 1.0cm2 impact adjacent cartilage integrity. The location of the maximum stress point also varied with larger defects. This study suggests that size cutoffs exist earlier in the natural history of chondral defects, as small as 0.49cm2, than previously studied, suggesting a lower threshold for intervention.
Postoperative knee stability is critical in determining the success after reconstruction; however, only posterior and anterior stability is assessed. Therefore, this study investigates medial and lateral rotational knee laxity changes after partial and complete PCL tear and after PCL allograft reconstruction. The extending Lachman test assessed knee instability in six fresh-frozen human cadaveric knees. Tibia rotation was measured for the native knee, after partial PCLT (pPCLT), after full PCLT (fPCLT), and then after PCLR tensioned at 30° and 90°. In addition, tests were performed for the medial and lateral sides. The tibia was pulled with 130N using a digital force gauge. A compression load of 50N was applied to the joint on the universal testing machine (MTS Systems) to induce contact. Three-dimensional tibial rotation was measured using a motion capture system (Optotrak). On average, the tibia rotation increased by 33%-42% after partial PCL tear, and by 62%-75% after full PCL tear when compared to the intact case. After PCL reconstruction, the medial tibia rotation decreased by 33% and 37% compared to the fPCL tear in the case that the allograft was tensioned at 30° and 90° of flexion, respectively. Similarly, lateral tibial rotation decreased by 15% and 2% for allograft tensioned at 30° and 90° of flexion respectively, compared to the full tear. Rotational decreases were statistically significant (p<0.005) at the lateral pulling after tensioning the allograft at 90°. PCLR with the graft tensioned at 30° and 90° both reduced medial knee laxity after PCLT. These results suggest that while both tensioning angles restored medial knee stability, tensioning the Achilles graft at 30° of knee flexion was more effective in restoring lateral knee stability throughout the range of motion from full extension to 90° flexion, offering a closer biomechanical resemblance to native knee function.
Lateral lumbar interbody fusion (LLIF) has biomechanical advantages due to the preservation of ligamentous structures (ALL/PLL), and optimal cage height afforded by the strength of the apophyseal ring. We compare the biomechanical motion stability of multiple levels LLIF (4 segments) utilising PEEK interbody 26mm cages to stand-alone cage placement and with supplemental posterior fixation with pedicle screw and rods. Six lumbar human cadaver specimens were stripped of the paraspinal musculature while preserving the discs, facet joints, and osteoligamentous structures and potted. Specimens were tested under 5 conditions: intact, posterior bilateral fixation (L1-L5) only, LLIF-only, LLIF with unilateral fixation and LLIF with bilateral fixation. Non-destructive testing was performed on a universal testing machine (MTS Systems Corp) to produce flexion-extension, lateral-bending, and axial rotation using customized jigs and a pulley system to define a non-constraining load follower. Three-dimensional spine motion was recorded using a motion device (Optotrak). Results are reported for the L3-L4 motion segment within the construct to allow comparison with previously published works of shorter constructs (1-2 segments). In all conditions, there was an observed decrease in ROM from intact in flexion/extension (31%-89% decrease), lateral bending (19%-78%), and axial rotation (37%-60%). At flexion/extension, the decreases were statistically significant (p<0.007) except for stand-alone LLIF. LLIF+unilateral had similar decreases in all planes as the LLIF+bilateral condition. The observed ROM within the 4-level construct was similar to previously reported results in 1-2 levels for stand-alone LLIF and LLIF+bilateral. Surgeons may be concerned about the biomechanical stability of an approach utilizing stand-alone multilevel LLIF. Our results show that 4-level multilevel LLIF utilizing 26 mm cages demonstrated ROM comparable to short-segment LLIF. Stand-alone LLIF showed a decrease in ROM from the intact condition. The addition of posterior supplemental fixation resulted in an additional decrease in ROM. The results suggest that unilateral posterior fixation may be sufficient.
The treatment of scapholunate (SL) ligament injuries is addressed by surgical procedures to stabilize the carpal joint. Open techniques include bone-ligament-bone transfers, tenodesis, partial fusions and carpectomies. Innovative procedures using wrist arthroscopy, offer minimally invasive fixation without full exposure of carpal bones; however, the success of the technique and its impact on the reduction on the range of carpal movement is as yet not well known. In this work, the performance of Corella tenodesis technique to repair the SL ligament is evaluated for a wrist type II by numerical methods. Human wrist can be classified based on the lunate morphology: type I for lunate that articulates with radius, scaphoid, capitate and triquetrum, and type II which has an extra surface to articulate with the hamate. A finite element model was constructed from CT-scan images, the model includes cortical and trabecular bones, articular cartilage and ligaments. Three scenarios were simulated representing healthy wrist, SL ligament sectioning and the Corella technique. The performance of the technique was assessed by measure the SL gap in dorsal and volar side as well as the SL angle to be compared to cadaveric studies. In intact position, the SL gap and the SL angle predicted by the numerical model is 2.8 mm and 44.8º, these values are consistent to the standard values reported in cadaveric experiments (2.0 ± 0.8 mm for SL gap and 45.8 ± 9.7 for SL angle). Virtual surgeries may help to understand and evaluate the performance of the techniques at clinical application.