Total meniscectomy has been shown to induce osteoarthritic changes in the underlying articular cartilage(AC) and bone in the natural knee (Fairbank 1948; McDermott 2006). This indicates the meniscus plays an important protective role, providing joint congruity and distributing contact forces, hence reducing contact stress. However, no friction and wear studies have been performed on meniscectomy. The aim of this study was to study the tribological response of the medial compartmental natural knee with and without the intact meniscus, under physiological dynamic loading and motion. The effect of normal and reduced loading was investigated. Eighteen month old bovine medial compartmental knees were used. A pendulum friction simulator (Simulation Solutions, UK) was used to apply a dynamic axial loads with peak loads of 1000N (normal) and 260N (reduced). Flexion-extension of amplitude 23degrees was applied and the experiments ran for 3600 cycles at 1Hz. Lubricant was 25% bovine serum in saline. A 9.4 Tesla MRI (Bruker) scanner and Analyze software (Mayo Clinic, US) were used to calculate wear volumes. A surface profilometer (Talysurf, Taylor-Hobson, UK) was used to measure the surface roughness of the specimen before and after the test. Coefficient of friction was found to increase with increased loading, with and without meniscus. With meniscus intact, no wear was found on AC and contact stresses were 4.9MPa and 2.8MPa, for normal and reduced loading respectively. On removal of meniscus, friction was higher at both loading conditions and surface fibrillation found on some of the AC surfaces. Contact stresses rose to 17.2MPa and 8.6MPa for normal and reduced loading. This study has shown for the first time, the direct elevation of the coefficient of friction, immediate surface fibrillation and biomechanical wear of AC upon removal of the meniscus. On removal of meniscus, peak stresses rose and surface damage occurred on AC surfaces. The removal of the meniscus means forces act across smaller areas and contact stresses are increased. Wear is increased due to the subsequent increase in direct solid-solid contact and loss of fluid support due to the unique biphasic nature of AC. This further supports retaining meniscus whenever possible in knee joint surgery.
Clinical reports of surgical intervention options, such as spacers or hemi-arthroplasties, particularly for treatment of young arthritic patients, have been poor [ Experiments were conducted in an anatomic pendulum friction simulator (SimSol, UK) using the medial femoral condyle of a bovine knee joint articulating against two conforming stainless steel (316L) tibial plates (R=50mm and 100mm). A simplified physiologic knee loading profile was applied represent both low loading and much higher physiological loading conditions, with peak load between 259N – 1.5kN). Tests were conducted in 25% bovine serum and run for 3600 and 300 cycles under the low and high loading conditions respectively. The motion was cycled at 1Hz with amplitude between −10°–13.1°. Cartilage wear was assessed qualitatively from surface roughness measurements using a surface profile using a surface profilometer (Taylor Hobson, UK). The friction and wear of cartilage articulating against the conforming tibial plates were compared to a positive control flat tibial plate model [