All four patients treated with en bloc resection (primary or secondary) had no recurrence but in two out of that cases a re-operation was necessary because of non union. At a mean follow up from 27 months (4–95) there were no recurrences or metastases at all The flexion/extension of the wrist in currettaged radius was 60° and 80° compared with 38° and 68° in reconstructed radius. The pronation/suppination was 90°/90° in the currettaged ones versus 77°/77° in the allograft replaced ones. The functional outcome evaluated with Mayo Wrist Score and DASH score showed an exellent outcome for both groups (84/7,7 Allograft <
->
85/10 Currettage)
The functional outcome proof no disadvantages in daily life and daily work compared to curettage. Thus allograft reconstruction of the distal radius represents a valuable alternative to arthrodesis.
Giant cell tumor of the distal radius is associated with a high local recurrence rate. En bloc resection of the distal radius and reconstruction using osteoarticular allograft, curettage with PMMA blomb, and allograft arthrodesis are established methods. The aim of the study was to evaluate the functional outcome of our patients with the DASH-Score and the Mayo Wrist score. In the last 7 years six patients were treated at our department due to a giant cell tumor of the distal radius. Two patients were primary treated with an en bloc resection. The other four were primary treated with curettage packing of the defect with polymethylmethacrylate. In two of these cases a secondary en bloc resection was performed for local recurrence. For evaluation of function in daily live we used the DASH score and the MAYO wrist score. The mean bone resection length was 5,25cm (5–6 cm).All four patients treated with en bloc resection (primary or secondary) had no recurrence but in two out of that cases a re-operation was necessary because of non union. At a mean follow up from 27 months (4–95) there were no recurrences or metastases at all. The flexion/extension of the wrist in currettaged radius was 60°/80° compared with 38°/68° in reconstructed radius. The pronation/suppination was 90°/90° in the currettaged ones versus 77°/77° in the allograft replaced ones. The functional outcome evaluated with Mayo Wrist Score and DASH score showed an excellent outcome for both groups (84/7,7 Allograft <
->
85/10 Currettage) Functional outcome of distal radius resection reconstruction using an allograft is highly satisfactory compared with the literature, however we experienced a high risk for pseudoarthrosis. For prevention of non union simultaneous bone grafting at the index operation could be advisable. Thus allograft reconstruction of the distal radius represents a valuable alternative to arthrodesis.
Periprosthetic osteolysis after total joint replacement is a well described complication. This normal slowly increasing process is caused by infection, implant loosening or more special, debris induced. However malignant processes may rarely occur at exact this location too. Based on clinical presentation and imaging it is sometimes difficult to exclude a local malignant process. We report two cases of extensive osteolysis after total hip replacement, including their follow up and a review of the relevant literature. Two female patients developed massive osteolysis in periprosthetic areas (pelvic area and proximal femur as well as distal femur) after being treated by total hip arthroplasty 14 and 18 years ago. In both cases a tumorous process was suspected after imaging and they were therefore referred to our clinic. In one case a rapidly progressing soft tissue swelling with extensive peri-articular osteolysis was considered to be a malignant tumour. After an incisional biopsy, an embolisation had to be performed due to continuous massive bleeding. Histology revealed a superinfected polyethylene disease, treated with a two stage revision surgery. The second patient presented with an impending fracture due an unusual osteolysis at the tip of the stem. Here again polyethylene debris was found at biopsy. Extensive osteolysis and/or soft tissue swelling caused by polyethylene debris may sometimes be difficult to differ from a tumorous process. As a guideline presented by Min WK. et al in 2008 a reactive bone-destroying process normally proceeds slowly in contrast to a more rapid progression in malignant disease. However, as presented in the first of our cases, exemptions may occur. In these cases a biopsy or at least a frozen section at operation should be obtained in order to exclude a real neoplasm.
Whereas thermography has already been used as an assessment of disease activity in some kinds of inflammatory arthritis, it is a new method for objektive pain evaluation in patients with joint prosthesis. To our knowledge, no study has tested the correlation between increase of temperature and anterior knee pain with total knee prosthesis yet. Thirteen patients were included in this study who suffered from anterior knee pain of the retinaculum patellae with total knee prosthesis. The patients were asked to walk 3 km before entering a room which was cooled down to 20 degrees Celsius. A black 1 cm times 4.5 cm square stripe was attached on the diameter of the patella and the patients rested for 20 minutes to cool down before thermographic fotos were taken from 90 degrees, 45 degrees, frontal medial and lateral. The evaluation of temperature difference of each side was performed by marking a 1cm times 2cm square field rectangular around the black stripe and comparing it with a reference point of the same size 3 cm distal of the field. The patients were compared with thirteen others, not suffering from anterior knee pain. Statistical analysis was performed using a t- test and a p value <
0.05 was considered to be significant. The temperature differences between the rectangular field and the reference point increased significantly on the medial (p= 0.00037) or lateral (p= 0.000002) pain side of the knee. The thirteen knees with knee pain had significantly higher temperature differences between medial and lateral temperature differences, than the knees without knee pain. We demonstrate a significant correlation between anterior knee pain and an increase of superficial skin temperature around the retinaculum patellae. To our knowledge, this is the first report of an objective assessment of pain of the retinaculum patellae with total knee prosthesis.