Cadaveric specimens that have been fresh-frozen and then thawed for use have historically been considered to be the gold standard for biomechanical studies and the closest surrogate to living tissue. However, there are notable issues related to specimen rapid decay in the thawed state as well as infectious hazard to those handling the specimens. Cadaveric specimen preparation using a new phenol-based soft-embalmed method has shown considerable promise in preserving tissue in a prolonged fresh-like state while mitigating the infection risk. In this study, we evaluated the ability of soft-embalmed specimens to replace fresh-frozen specimens in the biomechanical study of flexor tendon repair. An ex-vivo study was conducted on six cadaveric hands in both a fresh-frozen, thawed state and following embalming with a phenol-based solution. Six different combinations of flexor digitorum profundus (FDP) tendons, from D2 to D5, and flexor pollicis longus (FPL) tendons were used to create two groups of similar composition with 15 tendons each, one group to be tested fresh and the other following embalming. A 5cm length of each flexor tendon was harvested from zone 2 and transversely cut at the mid-section. A modified-Kessler repair was performed on each specimen using 4–0 Fiberwire, with two core sutures and 1cm purchase on each end. Incisions were closed with a running stitch to prepare the specimen for embalming. The same protocol was used to repair and harvest the second group of tendons one month following the perfusion of a phenol-based solution through the vasculature of the hand and forearm. Tendon repair biomechanics were characterised through a ramp loading to failure (rate 1mm/sec), incorporating the 12 mm travel distance of the testing machine. A video-extensometry technique was used to validate machine recordings for the repair site for force at the 2mm gap distance, the ultimate strength, and the mode of failure. Characteristics of the two groups were tested for equivalency using inferential confidence intervals (ICI). Both fresh and embalmed groups were indistinguishable in both force at 2mm gap (fresh 17.9±4.7N; embalmed 18.1±5.1) and ultimate strength (fresh 43.93±10.0; embalmed 43.7±9.4). With the exception of one specimen with complete suture pull-out, all specimens exhibited partial pull-out as the final mode of failure. Our study demonstrated that tendon repair characteristics of phenol-embalmed specimens were equivalent to fresh specimens. Post-mortem chemical preservation can indeed preserve both visual and biomechanical characteristics of soft tissues. This study opens new avenues in support of the use of embalmed specimens in medical curricula and surgical training.
Percutaneous fixation of scaphoid fractures has become popular in recent years, mainly due to its reduced complexity compared to open surgical approaches. Fluoroscopy is currently used as guidance for this percutaneous approach, however, as a projective imaging modality, it provides only a 2D view of the complex 3D anatomy of the wrist during surgery, and exposes both patient and physician to harmful X-ray radiation. To avoid these drawbacks, 3D ultrasound has been suggested to provide imaging for guidance as a widely available, real-time, radiation-free and low-cost modality. However, the blurred, disconnected, weak and noisy bone responses render interpretation of the US data difficult so far. In this work, we present the integration of 3D ultrasound with a statistical wrist model to allow development of an improved ultrasound-based guidance procedure. For enhancement of bone responses in ultrasound, a phase symmetry based approach is used to exploit the symmetry of the ultrasound signal around the expected bone location. We propose an improved estimation of the local phase symmetry by using the local spectrum variation of the ultrasound image. The statistical wrist model is developed through a group-wise registration based framework in order to capture the major modes of shape and pose variations across 30 subjects at different wrist positions. Finally, the statistical wrist model is registered to the enhanced ultrasound bone surfaces using a probabilistic registration approach. Feasibility experiments are performed using two volunteer wrists, and the results are promising and warrant further development and validation to enable ultrasound guided percutaneous scaphoid fracture reduction.
Reverse shoulder arthroplasty has a high complication rate related to glenoid implant instability and screw loosening. Better radiographic post-operative evaluation may help in understanding complications causes. Medical radiographic imaging is the conventional technique for post-operative component placement analysis. Studies suggest that volumetric CT is better than use of CT slices or conventional radiographs. Currently, post-operative CT use is limited by metal-artifacts in images. This study evaluated inter-observer reliability of pre-operative and post-operative CT images registration to conventional approaches using radiographs and CT slices in measuring reverse shoulder arthroplasty glenoid implant and screw percentage in bone. Pre-operative and post-operative CT scans, and post-operative radiographs were obtained from six patients that had reverse shoulder arthroplasty. CT scans images were imported into a medical imaging processing software and each scapula, glenoid implant and inferior screw were reconstructed as 3D models. Post-operative 3D models were imported into the pre-operative reference frame and matched to the pre-operative scapula model using a paired-point and a surface registration. Measurements on registered CT models were done in reference to the pre-operative scapula model coordinate frame defined by a computer-assisted designed triad positioned in respect to the center of the glenoid fossa and trigonum scapulae (medial-lateral, z axis) and superior and inferior glenoid tubercle (superior-inferior, y axis). The orthogonal triad third axis defined the anterior-posterior axis (x axis). A duplicate triad was positioned along the central axis of the glenoid implant model. Using a virtual protractor, the glenoid implant inclination was measured from its central axis and the scapula transverse plane (x - z axes) and version from the coronal plane (y - z axes). Inferior screw percentage in bone was measured from a Boolean intersection operation between the pre-operative scapula model and the inferior screw model. For CT slices and radiographic measurements, a first 90-degree Cobb angle, from medical records software, was positioned from the trigonum scapulae to the centre of the central peg. Using the 90-degree line as reference, a second Cobb angle was drawn from the most superior to the most inferior point of the glenoid implant for inclination and from of the most anterior to the most posterior point for version. Version can only be measured using CT slices. Screw percentage in bone was calculated from screw length measures collected with a distance-measuring tool from the software. For testing the inter-observer reliability of the three methods, measures taken by three qualified observers were analysed using an intra-class correlation coefficient (ICC) method. The 3D registration method showed excellent reliability (ICC > 0.75) in glenoid implant inclination (0.97), version (0.98) and screw volume in bone (0.99). Conventional methods showed poor reliability (ICC < 0.4); CT-slice inclination (0.02), version (0.07), percentage of screw in bone (0.02) and for radiographic inclination (0.05) and percentage screw in bone (0.05). This CT registration of post-operative to pre-operative novel method for quantitatively assessing reverse shoulder arthroplasty glenoid implant positioning and screw percentage in bone, showed excellent inter-observer reliability compared to conventional 2D approaches. It overcomes metal-artifact limitations of post-operative CT evaluation.
Recently, electromagnetic tracking for surgical procedures has gained popularity due to its small sensor size and the absence of line-of-sight restrictions. However, EM trackers are susceptible to measurement noise. Indeed, depending on the environment, measurement uncertainties may vary considerably. Therefore, it is important to characterise electromagnetic measurement systems when used in a fluoroscopy setting. The purpose of our study is to assess decoupled static electromagnetic measurement errors in position and orientation, without adding potential interference, in the presence of fluoroscopic imaging equipment. Using an Aurora electromagnetic tracking system (Northern Digital, Waterloo, Canada), 5 degrees of freedom measurements were collected in a working space located midway between the source and the receiver of a flat-panel 3D fluoroscope (Innova 4100, GE Healthcare, Buc, France) emitting X-rays. In addition, to determine potential EM distortion from X-rays, electromagnetic measurement accuracies, as a function of position, were compared before, during, and after X-ray emissions. To decouple position and orientation errors, two scaffold devices were designed. Their centre was placed approximately at X = −50, Y = 0, and Z = −300 mm in the EM tracker's global coordinate system. First the positioning scaffold was used to assess the position and orientation measurement uncertainties as a function of position. Next, the orienting scaffold was used to assess the position and orientation measurement uncertainties as a function of orientation. Then, a least-squares method was employed to register the path position measurements to the known geometry of the scaffolds. As a result, the position accuracy was defined as the Euclidean distance between the registered and the ground truth positions. Finally, the orientation accuracy was defined as the difference between two direct angles: the angle between two measured consecutive paths, and the angle of the corresponding ground truth. When translating the sensor using the positioning scaffold, the resulting position accuracy was characterised by a mean of 3.2 mm. Similarly, when rotating the sensor using the orienting scaffold, the resulting orientation accuracy was characterised by a mean of 1.7 deg. As for the “cross-displacement” errors, the orientation accuracy as a function of position had a mean of 1.8 deg. Likewise, the position as a function of orientation had a mean of 4.0 mm. Position and orientation accuracies – as a function of position, before, during, and after emission of X-rays – indicate that there was no significant interference by the presence of an X-ray beam on the EM measurements. This work provides evidence that placing the EM system into X-ray beams does not affect EM measurement accuracies. Nevertheless, the fluoroscope itself significantly increases the EM measurement errors. Careful analysis of the EM measurement distribution errors suggests that associated uncertainties are predictable and preventable. In essence, EM tracking is promising for orthopedic procedures that may require the use of a fluoroscope.
Primary internal fixation of uncomplicated scaphoid fractures is growing in popularity due to its advantages over conventional cast fixation. Performing the procedure percutaneously reduces the risk of infection and soft tissue damage, but can be tricky because of the small size and complex three-dimensional (3D) shape of this bone. Computer-assisted navigation has been an invaluable tool in other pin insertion procedures. This in-vitro study aimed to evaluate two different rendering techniques for our navigation interface: (i) 3D volume rendering of the CBCT image to show digitally-reconstructed radiographs of the anatomy, and (ii) volume-slicing, analogous to CT-images. As the shape of the scaphoid is highly variable, a plastic model of the wrist was constructed in order to provide consistency that would not be possible in a cadaver-based study. The plastic model featured a removable scaphoid such that a new one was replaced between trials. Three surgeons each performed eight trials using each of the two navigated techniques (yielding a total of 48 trials for analysis). Central placement of scaphoid fixation has been linked with mechanical stability and improved clinical outcomes, thus the surgical goal was to place a K-wire to maximise both depth from the surface and length of the drill path. The wire was drilled through the scaphoid, from distal to proximal, allowing for post-trial analysis of the drill path. A ceiling-mounted OptoTrak Certus camera (Northern Digital Inc., Canada) and a floor-mounted isocentric 3D CBCT C-arm (Innova 4100, GE Healthcare, France) permitted a registration transformation between the tracking and imaging systems to be computed preoperatively, before each trial, using a custom calibration device. Optical local coordinate reference bodies were attached to the wrist model and a custom drill guide for tracking with the Certus camera. During each trial, a 3D spin image of the wrist model was acquired, and rendered according to the technique under study. For 3D volume rendering, the spin image was rendered as a digitally-reconstructed radiograph (DRR) that could be rotated in three dimensions. In the planning phase, the surgeon positioned a desired drill path on the images. Anterior-posterior and lateral views of the 3D volume rendering were used for navigation during the drilling phase. The real-time orientation of the drill guide was shown relative to these images and the plan on an overhead. For volume-sliced (VS) navigation, the spin image was volume-rendered and sliced along the principal planes (axial, coronal, sagittal) for planning. A slider interface allowed the surgeon to scroll through the slices in each of the planes, as if they were looking at individual CT slices. Once the desired drill path was positioned, the volume-sliced views were reconfigured to show slices along the oblique planes of the planned path for navigation. Following all trials, model scaphoids with wire intact were imaged using CT with a slice thickness of 0.625 mm. The CT series were segmented and used to construct 3D digital models of the wire and drilled scaphoid. Algorithms were developed to determine the minimum distance from the centerline of the wire and the scaphoid surface, and to compute the length of the drill path. Screw breach should be avoided as it disrupts the articular surface and may lead to a sequela of cartilage deterioration and osteoarthritic changes. The shortest distance measure was extrapolated to assess whether a standard fixation screw (Accutrak Mini, 1.78 mm radius) would have breached the scaphoid surface. There were three screw breaches noted in the 3D DRR trials, while only one occurred using volume-slicing. The minimum distance from the centerline of the wire to the scaphoid surface can also be thought of as a “safe zone” for screw breach. Although no difference in the mean distance (μ) was noted between groups (μDRR = 2.3 mm, μVS = 2.2 mm), the standard deviation (σ) was significantly higher for the DRR trials (σDRR = 0.50 mm, σVS = 0.37 mm, p < 0.1), suggesting a higher reliability of central placement using VS for navigation. In contrast, the length of the drill paths were significantly longer for the DRR trials (μ = 28.7 mm, σ = 0.66 mm) than for VS-navigation (μ = 28.3 mm, σ = 0.62 mm) at p < 0.1. The surgical goal was to pick a path that maximised both the length of the path, as well as the minimum distance from the scaphoid surface. Algorithms were developed to find the paths that would maximise: (i) the length and (ii) the distance from the surface of the model scaphoid used in this study. The maximum possible length was 29.8mm (with a minimum distance of 2.2mm from the scaphoid surface), and the maximum distance was 3.3mm (with a length of 27.5mm). Therefore, the set of optimal drill paths had length > 27.5 mm, and distance > 2.8 mm. Of the DRR-navigated trials, 11 were below the minimum optimal depth, and only one trial was below the optimal length; 13 of the 24 trials (54%) were of both optimal length and depth. Of the VS-navigated trials, nine were below the minimal optimal distance, and four were below the minimum optimal length; 11 out of 24 trials (46%) were within both the optimal length and depth. From this comparative study, we conclude that VS-navigation was superior in locating a central location for the fixation wire, while DRRs were superior in maximising the depth of the drill path. Thus, we propose a hybrid interface, incorporating both volume-slicing and DRRs, in order to maximise the effectiveness of navigation for percutaneous scaphoid pinning.