This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study. A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m2 (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups.Aims
Patients and Methods
The object of this study was to develop a method to assess the accuracy of an image-free total knee replacement navigation system in legs with normal or abnormal mechanical axes. A phantom leg was constructed with simulated hip and knee joints and provided a means to locate the centre of the ankle joint. Additional joints located at the midshaft of the tibia and femur allowed deformation in the flexion/extension, varus/valgus and rotational planes. Using a digital caliper unit to measure the coordinates precisely, a software program was developed to convert these local coordinates into a determination of actual leg alignment. At specific points in the procedure, information was compared between the digital caliper measurements and the image-free navigation system. Repeated serial measurements were undertaken. In the setting of normal alignment the mean error of the system was within 0.5°. In the setting of abnormal plane alignment in both the femur and the tibia, the error was within 1°. This is the first study designed to assess the accuracy of a clinically-validated navigation system. It demonstrates
Routine prophylaxis for venous thromboembolic disease after total hip replacement (THR) is recommended. Pneumatic compression with foot pumps seems to provide an alternative to chemical agents. However, the overall number of patients investigated in randomised clinical trials has been too small to draw evidence-based conclusions. This randomised clinical trial was carried out to compare the effectiveness and safety of mechanical Inclusion criteria were osteoarthritis of the hip and age less than 80 years. Exclusion criteria included a history of thromboembolic disease, heart disease, and bleeding diatheses. There were 216 consecutive patients considered for inclusion in the trial who were randomised either for management with the A-V Impulse System foot pump. We excluded 16 patients who did not tolerate continuous use of the foot pump or with low-molecular-weight heparin (LMWH). Patients were monitored for DVT using serial duplex sonography at 3, 10 and 45 days after surgery. DVT was detected in three of 100 patients in the foot-pump group and with six of 100 patients in the LMWH group (p <
0.05). The mean post-operative drainage was 259 ml in the foot-pump group and 328 ml in the LMWH group (p <
0.05). Patients in the foot-pump group had less swelling of the thigh (10 mm compared with 15 mm; p <
0.05). One patient developed heparin-induced thrombocytopenia. This study confirms the effectiveness and safety of mechanical prophylaxis of DVT in THR. Some patients cannot tolerate the foot pump.
In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.
This is a biomechanical study measuring the maximum pull-out strength of implants inserted into vertebral bodies of the calf spine. The objective is to investigate the influence of different anchoring systems. The following implants were used: Zielke USIS (Ulrich, Ulm), Kaneda KASS (DePuy, Sulzbach). Universal Spine System (USS, Synthes, Umkirch) and Hollow Modular Anchorage (HMA) system (Aesculap, Tuttlingen). We selected nine groups with seven vertebrae equal in mean sizes and Bone Mineral Density (BMD) for each system. Vertebral body and implant were connected to both ends of a servohydraulic testing machine. Distraction was applied until failure and the maximum axial pullout force was recorded. No significant correlation of BMD and pullout strength appeared. The student t-test showed significant higher stability for USS with pullout resistant nut (4.0 kN) and KASS (two-screws, 4.2 kN) compared to all other systems (p <
0.025). The mode of failure was a burst fracture in these vertebrae and shearing in all other systems. Bicortical screws of USS (3.2 kN) showed stronger hold than single bicortical KASS (2.5 kN) and HMA 12 mm (2.6 kN). Zielke (2.1 kN) was equal to monocortical KASS (one screw 2.1 kN) and superior to monocortical USS (1.6 kN). All those provided less stability than HMA 14 mm (2.4 kN). For in-vitro testing with calf spines the influence of BMD seems to be less important than that of implant design. Maximum strength of Kaneda KASS depends on angulation of screws. Stability of USS implants can be increased by use of pullout resistant nuts. Of all monocortical implants only HMA presents pullout resistant strength comparable to bicortical screws. In-vivo use of monocortical anchorage bears the lowest risk of vascular injury, because the far cortex remains intact.
We have examined the effect of the Wagner spherical acetabular osteotomy on preserving the joint in 38 hips with a mean follow-up of 17 years. At the time of the initial operation, 55% of patients had clinical symptoms and 30 joints showed minimal or absent radiological signs of osteoarthritis. At follow-up, 54% of patients had a good functional result. The osteotomy improved the mean centre-edge angle from −3° to +15°, the mean anterior centre-edge angle to 23° and the acetabular head index to 75%. The obliquity of the acetabular roof decreased from 28° to 16°. One patient improved, but 14 deteriorated with joint degeneration. Of these, one progressed because of postoperative deep-tissue infection and five due to undercorrection. One patient needed total joint replacement after 14 years. At 17 years after operation, Wagner osteotomy had prevented progression of secondary arthritis in 63% of cases.