To assess the impact of two oral thromboprophylaxis agents against Clexane with regard to range of movement (ROM) following TKR with or without haemostasis following tourniquet release. Thromboprophylaxis choice following total knee replacement (TKR) has become of interest with the introduction of oral anticoagulants and support for these by NICE. Specific concerns with oral agents include a perceived elevated level of anti-coagulation and soft tissue complications. The population (n=264) was subclassified into cohorts regarding thromboprophylaxis cover: Clexane, Rivaroxaban and Dabigatran. Each subgroup was subdivided into whether surgery was performed with or without haemostasis following tourniquet release. This study demonstrates Clexane is associated with a better and earlier return of ROM post-operatively as compared to oral the thromboprophylaxis agents. This effect was more obvious when combined with haemostasis following early tourniquet release (p< 0.05). The oral thromboprophylaxis agents Rivaroxaban and Dabigatran had a relative negative effect on ROM as compared against Clexane. This was independent of whether the surgery was performed with or without haemostasis following tourniquet release. There was no different between the subgroups with repect to change of serum haemoglobin, symptomatic venous thromboembolism or rate of return to theatre.Study Aim
Methods & Results
Osteochondral defects of the knee may occur following patella dislocation or following direct trauma or twisting injuries to the knee in adolescents. Often a diagnostic and therapeutic challenge, if these lesions are left, posttraumatic osteoarthritis may occur. This retrospective single centre study presents the short-term results following operative fixation of osteochondral fragments of the knee using Omnitech ® screws. All skeletally immature patients presenting with an osteochondral fracture of their femur or patella confirmed on xray and MRI were identified. Arthroscopic evaluation of the osteochondral defect was performed followed by open reduction and internal fixation of the osteochondral fragment using Omnitech ® screws. A standard postoperative rehabilitation protocol was followed. Patients were evaluated at follow-up using a Knee Injury and Osteoarthritis Outcome Score (KOOS).Introduction
Method
Hydroxyapatite (HA) coated femoral stems require a press fit for initial stability prior to osteointegration occurring. However this technique can lead to perioperative femoral fracture. 506 consecutive patients under 72 years who underwent primary total hip replacements (THR) under 72 years were investigated for perioperative femoral fractures. All patients were independently assessed pre- and post-operatively in a research clinic. Assessment was made by Merle d'Aubigné and Postel (MDP) hip scores and radiographs. Between 1995 and 2001 patients were randomised to a partially HA coated, Osteonics Omnifit or fully HA coated Joint Replacement Instrumentation Furlong stem. Between 2001 and 2004 all patients received an Anatomique Benoist Girard (ABG II) stem partially coated. Fractures were identified from check radiographs and operative notes. The type of fracture was classified according to the modified Vancouver classification. The incidence of revision was also recorded.Introduction
Materials and Methods