Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 54 - 54
23 Feb 2023
Boyle R Stalley P Franks D Guzman M Maher A Scholes C
Full Access

We present the indications and outcomes of a series of custom 3D printed titanium acetabular implants used over a 9 year period at our institution (Sydney, Australia), in the setting of revision total hip arthroplasty.

Individualised image-based case planning with additive manufacturing of pelvic components was combined with screw fixation and off-the-shelf femoral components to treat patients presenting with failed hip arthroplasty involving acetabular bone loss. Retrospective chart review was performed on the practices of three contributing surgeons, with an initial search by item number of the Medicare Benefits Scheme linked to a case list maintained by the manufacturer. An analysis of indications, patient demographics and clinical outcome was performed.

The cohort comprised 65.2% female with a median age of 70 years (interquartile range 61–77) and a median follow up of 32.9 months (IQR 13.1 - 49.7). The indications for surgery were infection (12.5%); aseptic loosening (78.1%) and fracture (9.4%), with 65.7% of cases undergoing previous revision hip arthroplasty. A tumour prosthesis was implanted into the proximal femur in 21.9% of cases. Complications were observed in 31.3% of cases, with four cases requiring revision procedures and no deaths reported in this series. Kaplan-Meier analysis of all-cause revision revealed an overall procedure survival of 88.7% at two years (95%confidence interval 69 - 96.2) and 83.8% (95%CI 62 - 93.7) at five years, with pelvic implant-specific survival of 98% (95%CI 86.6 - 99.7) at two and five year follow up.

We conclude that an individualised planning approach for custom 3D printed titanium acetabular implants can provide high overall and implant-specific survival at up to five years follow up in complex cases of failed hip arthroplasty and acetabular bone loss.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 49 - 49
10 Feb 2023
Erian C Erian M Ektas N Scholes C Bell C
Full Access

Anterior cruciate ligament (ACL) ruptures are debilitating injuries, often managed via ACL reconstruction (ACLR). Reduced range of motion (ROM), particularly loss of extension (LOE), is the most significant contributor to post-operative patient dissatisfaction. LOE may preclude return to sport, increase re-rupture rates and precipitate osteoarthritis.

Passive LOE rates following ACLR have been reported at 15%. However, LOE incidence during active tasks are poorly characterised. Our review sought to determine knee extension angles for active tasks following an ACL injury or ACLR. We hypothesised greater incidences of active LOE following ACL injury or ACLR, compared to uninjured contralateral limbs or controls.

We systematically searched MEDLINE, Embase, Cochrane Library, Scopus, SPORTDiscus, and relevant trials databases for English articles. Included were cohort, cross-sectional, case-controlled or randomised controlled trials analysing adults with ACL injury treated surgically or otherwise, with at least 12-weeks follow-up and reporting either active knee extension angle, active LOE angles or incidence of active knee LOE during functional tasks. The protocol was registered on PROSPERO (CRD42018092295). Subsequent meta-analysis was performed.

After screening, 71 eligible articles were included. Studies were heterogenous in design and quality. Included tasks were overground walking (n=44), running (n=3), hopping/jumping/cutting (n=11) single-leg landing (n=7), and stair climbing (n=6). LOE incidence varied depending on functional activities (33.95-92.74%). LOE incidence did not vary depending on ACL status (67.26% vs. 65.90% vs. 62.57% for ACL intact, ACLD and ACLR, respectively).

We observed no difference in active LOE incidence according to ACL status. Importantly, the observed incidence for active LOE was reliably higher than previously reported rates for passive measures.

Given the discrepancy between active and passive LOE incidence, clinicians may advisably prioritise active ROM during ACL rehabilitation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 62 - 62
10 Feb 2023
Jewell E Martin S Metusela C Scholes C
Full Access

Novel oral anticoagulant (NOAC) use in Australia has increased significantly since their introduction to the Pharmaceutical Benefits Scheme (PBS). Currently, there are no specific guidelines regarding recommencement of NOAC therapy post-operatively for patients concurrently on a NOAC and undergoing arthroplasty. To address this gap in the literature, the aim of this study was to compare the clinical and patient-reported outcomes in a patient cohort recommencing a therapeutic dose of NOAC within 24 hours of total hip or knee arthroplasty.

Data was retrieved from a prospective registry (ACTRN1262000079698) containing hip and knee arthroplasties. Cases were labelled based on whether they presented on a therapeutic dose of NOAC prior to surgery or not. Descriptive statistics were used to summarise patient outcomes.

Of 291 patients undergoing 331 primary arthroplasties, 9.3% were undertaking NOAC therapy prior to their surgery. In the NOAC cohort, there was a 34.5% adverse event rate, however on closer analysis of each event, it was found that none of these events were complications in relation to NOAC use. This was compared to 15.6% of the comparison cohort who experienced a range of complications, some involving bleeding events. PROMs improved to a similar degree amongst both groups.

This study showed that recommencing therapeutic doses of NOACs in patients post hip and knee arthroplasty within 24 hours was safe. These findings will help guide larger scale analysis to better inform clinical guidelines pertaining to hip and knee arthroplasty.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 245 - 245
1 Mar 2013
Lustig S Scholes C Oussedik S Appleyard R Parker D
Full Access

Introduction & aims

Osteonecrosis may be triggered by bone temperature above 45°C during routine orthopaedic bone cuts using power-driven saws, with potentially negative impacts on bone healing. A new oscillating-tip saw blade design (Precision; Stryker, Kalamazoo, Mich) has been recently developed but the saw blade design may influence the amount of heat generated. We have therefore sought to compare the bone temperature during a standardised cutting task with two different saw blade designs.

Method

Three pairs of human cadaveric femora were obtained. Each femur was clamped and a distal femoral cutting jig was applied. An initial cut was performed to visualise the distal metaphyseal bone. The cutting block was then moved 2 mm proximal and a further cut performed, measuring the temperature of the bone with an infra-red camera. This was repeated, moving the block 2 mm proximal with each cut, alternating between a standard oscillating saw blade and the “Precision” saw blade. The density of the cut bone was then established from a CT scan of each specimen performed prior to the experiment.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 299 - 299
1 Mar 2013
Parker D Lustig S Scholes C Kinzel V Oussedik S Coolican M
Full Access

Purpose

Patient-matched instrumentation is advocated as the latest development in arthroplasty surgery. Custom-made cutting blocks created from preoperative MRI scans have been proposed to achieve perfect alignment of the lower limb in total knee arthroplasty (TKA). The aim of this study was to determine the efficacy of patient-specific cutting blocks by comparing them to navigation, the current gold standard.

Methods

60 TKA patients were recruited to undergo their surgery guided by Smith & Nephew Visionaire Patient-Matched cutting blocks. Continuous computer navigation was used during the surgery to evaluate the accuracy of the cutting blocks. The blocks were assessed for the fit to the articular surface, as well as alignment in the coronal, sagittal and rotational planes, sizing, and resection depth.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 57 - 57
1 Sep 2012
Whyte T Scholes C Li Q Coolican M Parker D
Full Access

High tibial osteotomy is a well established joint preserving procedure for the treatment of unicompartmental knee osteoarthritis. Of particular interest are the alterations in knee loading compartments during dynamic activities such as locomotion. Computer modelling can indirectly assess contact and muscle forces in the patient. This study aimed to develop a valid model representative of high tibial osteotomy to assess the medial joint contact force at the knee during gait.

Software for Interactive Musculoskeletal Modelling (version 2, SIMM Inc, USA) was used to develop a model to replicate the effects of high tibial osteotomy surgery on tibial alignment. The program was then used to perform a detailed analysis on gait data collected from two high tibial osteotomy patients preoperatively and 6 months post operatively. Inverse dynamics simulations were conducted to investigate knee joint contact force on the medial compartment of the two patients during the stance phase of their operated limbs.

Significant decreases (p<0.05) in the medial joint contact force were observed during both early and late stance for both patients. Force generated in muscles crossing the knee was found to be the major contributor to the joint contact force. Total muscle force was found to increase significantly (p<0.05) following surgery, however decreased loads were calculated for the medial compartment. The pattern and magnitude of joint reaction force was found to be consistent before and after surgery and replicated the results of previous studies. The HTO-specific model was valid and sensitive to changes in joint reaction force, medial joint contact force and muscle forces crossing the knee.

High tibial osteotomy reduced the medial joint contact force at the knee as a result of the coronal realignment of the limb. Osteoarthritis symptoms were relieved in terms of knee pain and function. Finally, a difference in compensatory strategies was observed between patients. This novel technique allows non-invasive assessment of the mechanical effect of procedures such as HTO. This should allow more accurate planning and assessment of such surgical procedures.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 37 - 37
1 Sep 2012
Kinzel V Scholes C Giuffrè B Coolican M Parker D
Full Access

Patient-matched instrumentation is advocated as the latest development in arthroplasty surgery. Custom-made cutting blocks created from preoperative MRI scans have been proposed to achieve perfect alignment of the lower limb in total knee arthroplasty (TKA). The aim of this study was to determine the efficacy of patient-specific cutting blocks by comparing them to navigation, the current gold standard.

25 TKA patients were recruited to undergo their surgery guided by Smith & Nephew Visionaire Patient-Matched cutting blocks. Continuous computer navigation was used during the surgery to evaluate the accuracy of the cutting blocks. The blocks were assessed for the fit to the articular surface, as well as alignment in the coronal and sagittal planes, sizing, and resection depth. Actual postoperative alignment was then assessed by detailed CT scans following the Perth protocol, comparing the results with intraoperative measurements.

All patient-matched cutting blocks were a good fit intra-operatively. Significant differences (p<0.05) in the resection depths of the distal femur and tibial plateau were observed between the cutting blocks and computer navigation for the medial compartment. Cutting block alignment of the femur and tibia in the coronal and sagittal planes also differed significantly (p<0.05) to navigation measurements. In addition, intraoperative assessment of sagittal femoral alignment differed to planned alignment by an average of 4.0 degrees (+/−2.3).

This study suggests the use of patient-matched cutting blocks is not accurate, particularly in the guidance of the sagittal alignment in total knee arthroplasty. Despite this technique creating well fitting cutting blocks, intraoperative monitoring, validated by postoperative CT scans, revealed an unacceptable degree of potential limb mal-alignment, resulting in increased outliers particularly when compared with standard computer navigation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 4 - 4
1 Sep 2012
Oussedik S Scholes C Leo S Ferguson D Roe J Parker D
Full Access

Computer navigation has been shown to improve the accuracy of total knee replacement (TKR) when compared to intra or extra osseous referencing. Currently the surgical transepicondylar axis (TEA) is used to help determine femoral component rotation. This relies on the surgeon identifying medial and lateral epicondyles intra-operatively. This process has been shown to have a high variability and operator dependency. The functional flexion axis (FFA) of the femur is a kinematically derived reference axis which has previously been shown in a cadaveric model to correspond well with the transepicondylar axis. This study was therefore designed to evaluate its accuracy in vivo.

50 patients undergoing total knee replacement under the care of the three senior authors were prospectively recruited. A preoperative CT scan was obtained and the TEA evaluated by 2 independent clinicians. TKR was undertaken in the standard fashion using Stryker navigation. The FFA was derived at 3 time points during the procedure: pre-incision, post osseous registration and following component implantation. The deviations of the FFA and surgical TEA (surTEA) to the CT-derived TEA (ctTEA) was calculated and comparisons drawn between the 2 methods with respect to validity, as well as within and between-patient reproducibility.

While the FFA results were highly correlated between pre and post-arthrotomy (r = 0.89), the post-incision FFA (−1.60+/−3.7) was significantly internally rotated (p<0.01) relative to the pre-incision FFA (−2.50+/−3.4). In addition the surgical TEA (−0.40+/−3.6) was significantly internally rotated (p = 0.02) relative to the post-incision FFA (1.80+/−3.7) for the combined data from all 2 surgeons. However, when examined individually, 1 of the 2 surgeons showed no significant difference between the FFA and TEA. In addition, the two methods demonstrated comparable between-patient variability in the knee axis, although surgeon-dependent patterns remained.

The FFA has been shown to be of equivalent accuracy to the surgical TEA but surprisingly does not avoid its operator-dependency. Further evaluation of the FFA method with possible adjustments to the algorithm is warranted.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 155 - 155
1 Sep 2012
Widmer B Conrad L Scholes C Oussedik S Coolican M Parker D
Full Access

Computer assisted surgical navigation has played an increasingly central role in total knee arthroplasty (TKA). Given the recognized importance of subtle component position changes in knee function, navigation has emerged as a promising tool for reducing the occurrence of significant malalignment. The ability of this technology to reliably measure multiple parameters intraoperatively allows analysis to possibly identify a correlation between intraoperative computer assisted surgical navigation data and functional outcomes of patients undergoing elective total knee arthroplasty.

Intraoperative navigation data was collected for 121 patients undergoing cemented, posterior stabilized TKA. Three forward stepwise regression analyses were performed to associate intraoperative coronal alignment correction, tibiofemoral external rotation, and alignment under varus and valgus stress with one year outcomes, including range of motion, Oxford and SF-36 scores.

The amount of alignment correction and the maximum flexion achieved intraoperatively were significantly correlated (p <0.05, R-sq = 13%) with clinically measured maximum flexion at one year. Maximum flexion achieved intraoperatively, external tibiofemoral rotation and maximum varus under stress were also significantly associated (p < 0.05, R-sq = 31%) with the physical component of the SF-36 outcome score.

Analyses of computer navigation in TKA to date have primarily focused on precision of sagittal plane correction. Alternatively we have identified four intraoperative parameters that correlate with functional outcome at one year. Correct intraoperative interpretation of navigation data may allow surgeons to make subtle changes in real time to produce superior short-term outcomes for patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 121 - 121
1 Sep 2012
Scholes C Houang J Lynch J Coolican M Parker D
Full Access

The question of whether to reconstruct an ACL-deficient knee as early as possible following injury or to delay surgery remains unanswered. Early reconstruction potentially reduces the risk of secondary damage. However, there is also concern regarding the risk of arthrofibrosis if surgery is undertaken too soon. The aim of this study was to investigate whether injury-to-surgery delay determines ACL-reconstruction outcomes at up to 2years post-operatively.

A retrospective analysis of prospectively collected data from 211 knees with isolated primary ACL ruptures was performed. Patients were examined preoperatively, at 6months, 1 year, and 2 years post-operatively using International Knee Documentation Committee (IKDC) and Lysholm scores. Side to side differences in knee laxity were also measured with a KT1000 arthrometer. Spearman's rho correlations were used to associate injury-to-surgery delay with outcome scores.

Outcomes scores significantly increased for both IKDC (p<0.05) and Lysholm (p<0.05) questionnaires. Significant positive correlations (p<0.05) were also found between injury-to-surgery delay and IKDC and Lysholm subjective scores. Strongest correlation coefficients were noted at the 2yr follow-up for both IKDC and Lysholm scores (r = 0.79 and 0.8 respectively). Side-to-side laxity measures also showed significant positive correlations with injury-to-surgery delay at 1 year (r = 0.17) and 2 year (r = 0.41) follow ups. The positive correlation suggests that delayed surgery is positively related to subjective outcomes, as well as objective measures of knee laxity.

However, this relationship also suggests that other factors such as the patient's functional status at time of surgery may play a role in their post-operative function. For example, those who can compensate for the ruptured ligament may function well following delayed surgery. These findings highlight the need for more detailed investigation of the interaction between functional status, injury-to-surgery delay and post-operative recovery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 125 - 125
1 Sep 2012
Jin A Lynch J Scholes C Li Q Coolican M Parker D
Full Access

An ACL reconstruction is designed to restore the normal knee function and prevent the onset and progression of degenerative changes such as osteoarthritis. However, contemporary literature provides limited consensus on whether knee degeneration can be attenuated by the reconstruction procedure. The aim of this pilot study was to identify the presence of early osteoarthritis after ACL reconstruction using MRI analysis.

19 patients who had undergone an ACL reconstruction (9 isolated ACL rupture, 8 ACL rupture and meniscectomy, 2 ACL rupture and meniscal repair) volunteered for this study. MRI's were collected preoperatively and postoperatively for analysis with a mean follow up of 23 months. The Boston-Leeds Osteoarthritis Knee Score (BLOKS) was used for the analysis of the articular cartilage by a consultant orthopaedic surgeon. Scores ranged from 0–3, with 0 being total coverage and thickness of the cartilage and 3 being no coverage. Qualitative analysis was then conducted on each patient to determine if the articular cartilage improved, degenerated, or did not change between preoperative and follow-up scans.

All patients with isolated ACL rupture were found to either have no change or improved articular cartilage scores in their follow up scans compared preoperatively. In contrast, patients with a meniscal repair displayed worse cartilage scores postoperatively. Lastly, of the patients who had an associated meniscectomy, 6 had worse follow-up results, with the remaining patients showing no change or improved cartilage scores.

The present results indicate that patients with an isolated ACL rupture have a reduced risk of developing OA compared to those with associated meniscal injuries. This has implications for analysing the outcome of current ACL reconstruction techniques and in predicting the likelihood of patients developing OA after ACL reconstruction. Future work will involve confirming this pattern in a larger patient sample, as well as exploring additional factors such as time to surgery delay and rehabilitation strategy.