During TKR it is mandatory to achieve perfect soft tissue balance and component alignment. It is necessary to access all tight structures for proper releases. We aim to analyze the results of Trivector arthrotomy approach for TKRs. It is a retrospective study of 1050 cases between 2010-2020. All cases were performed by a single surgeon. Approach includes dividing distal 30% of vastus medialis along with medial retinaculum - 1cm medial to patella and patellar tendon distally up to Tibial tuberosity and raised as a single flap.Introduction & Aim
Methods
Instability in ACL deficient knees can lead to medial compartment osteoarthritis. The risk of developing significant OA is 5x higher in knees with ACL deficiency. In associated Varus, there is quicker progression of the medial OA along with a varus thrust exerting strain on the ACL graft. The simultaneous valgus HTO and ACL reconstruction decompresses the medial tibiofemoral joint, corrects the mechanical-axis and reduces strain on the graft. Outcomes for this simultaneous procedure are still unclear in literature and we attempt evaluating its functional outcome. This Panel study was performed using data from 2019 to 2022 on 21 patients who had ACL insufficiency with Varus or medial OA and underwent a simultaneous Opening-wedge HTO with Arthroscopic ACL reconstruction. The mean follow-up was 2 years. The patients were evaluated with IKDC and Lysholm scores, Lachman test and ROM pre and post-operatively. The HKA was compared pre and post-operatively and the complications were evaluated. The progression of OA was evaluated with serial radiographs post-operatively.Introduction
Methods
The use of All-Poly Tibia has been in practice since the early 1970's. Recently due to the reports on wear and osteolysis in other articulations, this component has generated significant interest. In the current study we aim to report early medium-term results of All-poly Tibial components in elderly (>70 years) patients. Study of 455 cases done between 2005-2020. All the cases were performed by a single surgeon. All-Poly Tibial component implantations were performed using Standard mechanical jigs and the same posterior-stabilized implant was used for all cases.Introduction & Aim
Method
Conferences centered around surgery suffers from gender disparity with male faculty having a more dominant presence in meetings compared to female faculty. Orthopedic Surgery possibly suffers the most from this problem of all surgical specialties, and is reflective of a gender disparity in the field. The objective of this study was to investigate the prevalence of “manels”, or male-only sessions, in eight major Orthopedic Surgery meetings hosted in 2021 and to quantify the differences in location of practice, academic position, years of practice, and research qualifications between male and female faculty. Eight Orthopedic conferences organized by major Orthopedic associations (AAOS, COA, OTA, EFORT, AAHKS, ORS, NASS, and AOSSM) from February 2021 to November 2021 were analyzed. Meeting information was retrieved from the conference agendas, and details of chairs and speakers were obtained from Linkedin, Doximity, CPSO, personal websites, and Web of Science. Primary outcomes included: one) percentage of male faculty in all included sessions and two) overall percentage of manels. Secondary outcomes included one) percentage of male speakers and chairs in all included sessions, two) overall percentage of male-chair and male-speaker only sessions. Comparisons for outcomes were made between conferences and session topics (adult reconstruction hip, adult reconstruction knee, practice management/rehabilitation, trauma, sports, general, pediatrics, upper extremity, musculoskeletal oncology, foot and ankle, spine, and miscellaneous). Mean number of sessions for male and female were compared after being stratified into quartiles based on publications, sum of times cited, and H-indexes. Data was analyzed with non-parametric analysis, chi-square tests, or independent samples t-tests using SPSS version 28.0.0.0 with a p-value of < 0 .05 being considered statistically significant. Of 193 included sessions, 121 (62.3%) were manels and the mean percentage of included faculty that was male was 88.9% Apart from the topics of practice management/rehabilitation and musculoskeletal oncology, male representation was very high. Additionally, most included conferences had an extremely high percentage of male representation apart from meetings hosted by the COA and ORS. Non-manel sessions had a greater mean number of chairs (p=0.006), speakers (p < 0 .001), and faculty (p < 0 .001) than manel sessions. Of 1080 total included faculty members, 960 (88.9%) were male. Male faculty were more likely to be Orthopedic surgeons than female faculty (p < 0 .001) while also more likely to hold academic rank as a professor. Mean number of sessions between male and female faculty within their respective quartiles of H-indexes, sum of times cited, and number of publications did not reach statistical significance. Mean years of practice between male and female faculty was also not significantly different. There is a high prevalence of manels and an overall lack of female representation in Orthopedic meetings. Orthopedic associations should aim to make efforts to increase gender equity in future meetings.
Knee arthroscopy with meniscectomy is the third most common Orthopaedic surgery performed after TKA and THA, comprising up to 16.6% of all procedures. The efficiency of Orthopaedic care delivery with respect to waiting times and systemic costs is extremely concerning. Canadian Orthopaedic patients experience the longest wait times of any G7 country, yet perioperative surgical care constitutes a significant portion of a hospital's budget. In-Office Needle Arthroscopy (IONA) is an emerging technology that has been primarily studied as a diagnostic tool. Recent evidence shows that it is a cost-effective alternative to hospital- and community-based MRI with comparable accuracy. Recent procedure guides detailing IONA medial meniscectomy suggest a potential node for OR diversion. Given the high case volume of knee arthroscopy as well as the potential amenability to be diverted away from the OR to the office setting, IONA has the potential to generate considerable improvements in healthcare system efficiency with respect to throughput and cost savings. As such, the purpose of this study is to investigate the cost savings and impact on waiting times on a mid-sized Canadian community hospital if IONA is offered as an alternative to traditional operating room (OR) arthroscopy for medial meniscal tears. In order to develop a comprehensive understanding and accurate representation of the quantifiable operations involved in the current state for medial meniscus tear care, process mapping was performed that describes the journey of a patient from when they present with knee pain to their general practitioner until case resolution. This technique was then repeated to create a second process map describing the hypothetical proposed state whereby OR diversion may be conducted utilizing IONA. Once the respective process maps for each state were determined, each process map was translated into a Dupont decision tree. In order to accurately determine the total number of patients which would be eligible for this care pathway at our institution, the OR booking scheduling for arthroscopy and meniscectomy/repair over a four year time period (2016-2020) were reviewed. A sensitivity analysis was performed to examine the effect of the number of patients who select IONA over meniscectomy and the number of revision meniscectomies after IONA on 1) the profit and profit margin determined by the MCS-Dupont financial model and 2) the throughput (percentage and number) determined by the MCS-throughput model. Based on historic data at our institution, an average of 198 patients (SD 31) underwent either a meniscectomy or repair from years 2016-2020. Revenue for both states was similar (p = .22), with the current state revenue being $ 248,555.99 (standard deviation $ 39,005.43) and proposed state of $ 249,223.86 (SD $ 39,188.73). However, the reduction in expenses was significant (p < .0001) at 5.15%, with expenses in the current state being $ 281,415.23 (SD $ 44,157.80) and proposed state of $ 266,912.68 (SD $ 42,093.19), representing $14,502.95 in savings. Accordingly, profit improvement was also significant (p < .0001) at 46.2%, with current state profit being $ (32,859.24) (SD $ 5,153.49) and proposed state being $ (17,678.82) (SD $ 2,921.28). The addition of IONA into the care pathway of the proposed state produced an average improvement in throughput of 42 patients (SD 7), representing a 21.2% reduction in the number of patients that require an OR procedure. Financial sensitivity analysis revealed that the proposed state profit was higher than the current state profit if as few as 10% of patients select IONA, with the maximum revision rate needing to remain below 40% to achieve improved profits. The most important finding from this study is that IONA is a cost-effective alternative to traditional surgical arthroscopy for medial meniscus meniscectomy. Importantly, IONA can also be used as a diagnostic procedure. It is shown to be a cost-effective alternative to MRI with similar diagnostic accuracy. The role of IONA as a joint diagnostic-therapeutic tool could positively impact MRI waiting times and MRI/MRA costs, and further reduce indirect costs to society. Given the well-established benefit of early meniscus treatment, accelerating both diagnosis and therapy is bound to result in positive effects.
The 2020-2021 Canadian Residency Matching Service (CaRMS) match year was altered on an unprecedented scale. Visiting electives were cancelled at a national level, and the CaRMS interview tour was moved to a virtual model. These changes posed a significant challenge to both prospective students and program directors (PDs), requiring each party to employ alternative strategies to distinguish themselves throughout the match process. For a variety of reasons, including a decline in applicant interest secondary to reduced job prospects, the field of orthopaedic surgery was identified as vulnerable to many of these changes, creating a window of opportunity to evaluate their impacts on students and recruiting residency programs. This longitudinal survey study was disseminated to match-year medical students (3rd and 4th year) with an interest in orthopaedic surgery, as well as orthopaedic surgery program directors. Responses to the survey were collected using an electronic form designed in Qualtrics (Qualtrics, 2021, Provo, Utah, USA). Students were contacted through social media posts, as well as by snowball sampling methods through appropriate medical student leadership intermediates. The survey was disseminated to all 17 orthopedic surgery program directors in Canada. A pre-match and post-match iteration of this survey were designed to identify whether expectations differed from reality regarding the effect of the COVID-19 pandemic on the CaRMS match 2020-2021 process. A similar package was disseminated to Canadian orthopaedic surgery program directors pre-match, with an option to opt-in for a post-match survey follow-up. This survey had a focus on program directors’ opinions of various novel communication, recruitment, and assessment strategies, in the wake of the COVID-19 pandemic. Students’ responses to the loss of visiting electives were negative. Despite a reduction in financial stress associated with reduced need to travel (p=0.001), this was identified as a core component of the clerkship experience. In the case of virtual interviews, students’ initial trepidation pre-CaRMS turned into a positive outlook post-CaRMS (significant improvement, p=0.009) indicating an overall satisfaction with the virtual interview format, despite some concerns about a reduction in their capacity to network. Program directors and selection committee faculty also felt positively about the virtual interview format. Both students and program directors were overwhelmingly positive about virtual events put on by both school programs and student-led initiatives to complement the CaRMS tour. CaRMS was initially developed to facilitate the matching process for both students and programs alike. We hope to continue this tradition of student-led and student-informed change by providing three evidence-based recommendations. First, visiting electives should not be discontinued in future iterations of CaRMS if at all possible. Second, virtual interviews should be considered as an alternative approach to the CaRMS interview tour moving forward. And third, ongoing virtual events should be associated with a centralized platform from which programs can easily communicate virtual sessions to their target audience.
In the current healthcare environment, cost containment has become more important than ever. Perioperative services are often scrutinized as they consume more than 30% of North American hospitals’ budgets. The procurement, processing, and use of sterile surgical inventory is a major component of the perioperative care budget and has been recognized as an area of operational inefficiency. Although a recent systematic review supported the optimization of surgical inventory reprocessing as a means to increase efficiency and eliminate waste, there is a paucity of data on how to actually implement this change. A well-studied and established approach to implementing organizational change is Kotter's Change Model (KCM). The KCM process posits that organizational change can be facilitated by a dynamic 8-step approach and has been increasingly applied to the healthcare setting to facilitate the implementation of quality improvement (QI) interventions. We performed an inventory optimization (IO) to improve inventory and instrument reprocessing efficiency for the purpose of cost containment using the KCM framework. The purpose of this quality improvement (QI) project was to implement the IO using KCM, overcome organizational barriers to change, and measure key outcome metrics related to surgical inventory and corresponding clinician satisfaction. We hypothesized that the KCM would be an effective method of implementing the IO. This study was conducted at a tertiary academic hospital across the four highest-volume surgical services - Orthopedics, Otolaryngology, General Surgery, and Gynecology. The IO was implemented using the steps outlined by KCM (Figure 1): 1) create coalition, 2) create vision for change, 3) establish urgency, 4) communicate the vision, 5) empower broad based action, 6) generate general short term wins, 7) consolidate gains, and 8) anchor change. This process was evaluated using inventory metrics - total inventory reduction and depreciation cost savings; operational efficiency metrics - reprocessing labor efficiency and case cancellation rate; and clinician satisfaction. The implementation of KCM is described in Table 1. Total inventory was reduced by 37.7% with an average tray size reduction of 18.0%. This led to a total reprocessing time savings of 1333 hours per annum and labour cost savings of $39 995 per annum. Depreciation cost savings was $64 320 per annum. Case cancellation rate due to instrument-related errors decreased from 3.9% to 0.2%. The proportion of staff completely satisfied with the inventory was 1.7% pre-IO and 80% post-IO. This was the first study to show the success of applying KCM to facilitate change in the perioperative setting with respect to surgical inventory. We have outlined the important organizational obstacles faced when making changes to surgical inventory. The same KCM protocol can be followed for optimization processes for disposable versus reusable surgical device purchasing or perioperative scheduling. Although increasing efforts are being dedicated to quality improvement and efficiency, institutions will need an organized and systematic approach such as the KCM to successfully enact changes. For any figures or tables, please contact the authors directly.
Three-dimensional (3D) printing has become more frequently used in surgical specialties in recent years. Orthopaedic surgery is particularly well-suited to 3D printing applications, and thus has seen a variety of uses for this technology. These uses include pre-operative planning, patient-specific instrumentation (PSI), and patient-specific implant production. As with any new technology, it is important to assess the clinical impact, if any, of three-dimensional printing. The purpose of this review was to answer the following questions:
What are the current clinical uses of 3D printing in orthopaedic surgery? Does the use of 3D printing have an effect on peri-operative outcomes? Four electronic databases (Embase, MEDLINE, PubMed, Web of Science) were searched for Articles discussing clinical applications of 3D printing in orthopaedics up to November 13, 2018. Titles, abstracts, and full texts were screened in duplicate and data was abstracted. Descriptive analysis was performed for all studies. A meta-analysis was performed among eligible studies to compare estimated blood loss (EBL), operative time, and fluoroscopy use between 3D printing cases and controls. Study quality was assessed using the Methodological Index for Non-Randomized Studies (MINORS) criteria for non-randomized studies and the Cochrane Risk of Bias Tool for randomized controlled trials (RCTs). This review was prospectively registered on PROSPERO (Registration ID: CRD42018099144). One-hundred and eight studies were included, published between 2012 and 2018. A total of 2328 patients were included in these studies, and 1558 patients were treated using 3D printing technology. The mean age of patients, where reported, was 47 years old (range 3 to 90). Three-dimensional printing was most commonly reported in trauma (N = 41) and oncology (N = 22). Pre-operative planning was the most common use of 3D printing (N = 63), followed by final implants (N = 32) and PSI (N = 22). Titanium was the most commonly used 3D printing material (16 studies, 27.1%). A wide range of costs were reported for 3D printing applications, ranging from “less than $10” to $20,000. The mean MINORS score for non-randomized studies was 8.3/16 for non-comparative studies (N = 78), and 17.7/24 for non-randomized comparative studies (N = 19). Among RCTs, the most commonly identified sources of bias were for performance and detection biases. Three-dimensional printing resulted in a statistically significant decrease in mean operative time (−15.6 mins, p < .00001), mean EBL (−35.9 mL, p<.00001), and mean fluoroscopy shots (−3.5 shots, p < .00001) in 3D printing patients compared to controls. The uses of 3D printing in orthopaedic surgery are growing rapidly, with its use being most common in trauma and oncology. Pre-operative planning is the most common use of 3D printing in orthopaedics. The use of 3D printing significantly reduces EBL, operative time, and fluoroscopy use compared to controls. Future research is needed to confirm and clarify the magnitude of these effects.
To assess the current literature on suture anchor placement for the purpose of identifying factors that lead to suture anchor perforation and techniques that reduce the likelihood of complications. Three databases (PubMed, Ovid MEDLINE, EMBASE) were searched, and two reviewers independently screened the resulting literature. Methodological quality of all included papers was assessed using Methodological Index for Non-Randomized Studies criteria and the Cochrane Risk of Bias Assessment tool. Results are presented in a narrative summary fashion using descriptive statistics. Fourteen studies were included in this review. Four case series (491 patients, 56.6% female, mean age 33.9 years), nine controlled cadaveric/laboratory studies (111 cadaveric hips and 12 sawbones, 42.2% female, mean age 60.0 years), and one randomized controlled trial (37 hips, 55.6% female, mean age 34.2 years) were included. Anterior cortical perforation by suture anchors led to pain and impingement of pelvic neurovascular structures. The anterior acetabular positions (three to four o'clock) had the thinnest bone, smallest rim angles, and highest incidence of articular perforation. Drilling angles from 10° to 20° measured off the coronal plane were acceptable. The mid-anterior (MA) and distal anterolateral (DALA) portals were used successfully, with some studies reporting difficulty placing anchors at anterior locations via the DALA portal. Small-diameter (< 1 .8-mm) suture anchors had a lower in vivo incidence of articular perforation with similar stability and pull-out strength in biomechanical studies. Suture anchors at anterior acetabular rim positions (3–4 o'clock) should be inserted with caution. Large-diameter (>2.3-mm) suture anchors increase the likelihood of articular perforation without increasing labral stability. Inserting small-diameter (< 1 .8-mm) all-suture suture anchors (ASAs) from 10° to 20° using curved suture anchor drill guides, may increase safe insertion angles from all cutaneous portals. Direct arthroscopic visualization, use of fluoroscopy, distal-proximal insertion, and the use of nitinol wire can help prevent articular violation.
Polyetheretherketone (PEEK) has been proposed as an implant material for femoral total knee arthroplasty (TKA) components. Potential clinical advantages of PEEK over standard cobalt chrome alloys include modulus of elasticity and subsequently reduced stress shielding potentially eliminating osteolysis, thermal conduction properties allowing for a more natural soft tissue environment, and reduced weight enabling quicker quadriceps recovery. Manufacturing advantages include reduced manufacturing and sterilization time, lower cost, and improved quality control. Currently, no PEEK TKA implants exist on the market. Therefore, evaluation of mechanical properties in a pre-clinical phase is required to minimize patient risk. The objectives of this study include evaluation of implant fixation and determination of the potential for reduced stress shielding using the PEEK femoral TKA component. Experimental and computational analysis was performed to evaluate the biomechanical response of the femoral component (Freedom Knee, Maxx Orthopedics Inc., Plymouth Meeting, PA; Figure 1). Fixation strength of CoCr and PEEK components was evaluated in pull-off tests of cemented femoral components on cellular polyurethane foam blocks (Sawbones, Vashon Island, WA). Subsequent testing investigated the cemented fixation using cadaveric distal femurs. The reconstructions were subjected to 500,000 cycles of the peak load occurring during a standardized gait cycle (ISO 14243-1). The change from CoCr to PEEK on implant fixation was studied through computational analysis of stress distributions in the cement, implant, and the cement-implant interface. Reconstructions were analyzed when subjected to standardized gait and demanding squat loads. To investigate potentially reduced stress shielding when using a PEEK component, paired cadaveric femurs were used to measure local bone strains using digital image correlation (DIC). First, standardized gait load was applied, then the left and right femurs were implanted with CoCr and PEEK components, respectively, and subjected to the same load. To verify the validity of the computational methodology, the intact and reconstructed femurs were replicated in FEA models, based on CT scans.Introduction
Methods and Materials
In patients presenting with significant ligamentous instability/insufficiency and/or significant varus/valgus deformity of the knee, reproduction of knee alignment and soft tissue stability continues to be a difficult task to achieve. These complex primary total knee arthroplasty (TKA) candidates generally require TKA systems incorporating increasing levels of constraint due to the soft-tissue and/or bone deficiencies. In addition, achievement of “normal” gap symmetry through physiologic kinematics is challenging due to the complexity of the overall correction. Advancements in TKA design have not fully addressed the negative consequences of the increased forces between the degree of component constraint, the femoral box, and the tibial post. The purpose of this early feasibility study was to introduce the design characteristics of a primary TKA system that incorporates progressive constraint kinematics using a low profile trapezoidal femoral box, and to assess the short-term clinical and radiographic results of this patient cohort. We retrospectively evaluated 22 consecutive, non-selected, complex primary TKA patients with a minimum of 3-years follow-up and varus deformity of > 20 degrees or valgus deformity of >15 degrees. The Progressive Constraint Kinematics® Knee System (PCK, MAXX Orthopedics, Norristown, PA) was used and provides a variable constraint profile, from high constraint in extension to less constraint in flexion through a novel trapezoidal femoral box. We evaluated patient demographics, pre- and post-operative serial radiography, range of motion (ROM), and total Knee Society Score (KSS – total score). General descriptive statistics and paired t-Test to assess the difference between means at p <0.05 level of significance.INTRODUCTION
METHODS
Fungi are a rare and devastating cause of Periprosthetic Joint Infection (PJI). Diagnosis and treatment is a challenge as there are currently no specific guidelines. A recently published review identified 75 case reports of fungal PJI. The aim is to describe our experience of treating fungal PJI since 2011 within the Bone Infection Unit at our institution.Introduction
Aim
One of the important criteria of the success of TKR is achievement of the Flexion ROM. Various factors responsible to achieve flexion are technique, Implant and patient related. Creation of the Posterior condylar offset is one such important factor to achieve satisfactory flexion. To correlate post op femoral condylar offset to final flexion ROM at 1 yr. post op.Introduction
Aim
Fixed flexion isolated or along with varus / valgus is a common deformity for patients undergoing TKR. For a satisfactory outcome and normal gait post op FFD needs to be corrected completely. An additional distal femoral resection may be necessary to equalize the extension gape to correct Gr 2 FFDs. To demonstrate full FFD correction without resecting extra distal Femur.Introduction
Aim
Various implant designs and bearing surfaces are used in TKR. The use of All Poly Tibia and poly moulded on Tibial metal base plate has been in practice since long. Recently due to the reports on wear and osteolysis in modular articulations, these components have generated significant interest. To report early medium term results in elderly (>70 years) patients.Introduction
Aim
One of the important criteria of the success of TKR is achievement of the Flexion ROM. Various factors responsible to achieve flexion are technique, Implant and patient related. Creation of the Posterior condylar offset is one of the important factors to achieve satisfactory flexion. To correlate post op femoral condylar offset to final flexion ROM at 1 yr. post op.Introduction:
Aim:
During TKR it is mandatory to achieve perfect soft tissue balance and component alignment. As knee is covered in front by quadriceps mechanism, there is some manipulation of this structure while approaching knee for an arthroplasty. This alteration in Quadriceps mechanism can affect outcome of the surgery. To analyze the results of Trivector arthrotomy for TKR surgery.Introduction:
Aim:
Negative remodelling of the femoral cortex in the form of calcar resorption due to stress shielding and cortical hypertrophy at the level of the tip of the implant, due to distal load transfer, is frequently noted following cemented total hip replacement, most commonly with composite beam implants, but also with polished double tapers. The C-stem polished femoral component was designed with a third taper running from lateral to medial across and along the entire length of the implant, with the aim of achieving more proximal and therefore more natural loading of the femur. The hoop stresses generated in the cement mantle are transferred to the proximal bone starting at the calcar, which should theoretically minimise stress-shielding and calcar resorption, as well as reducing distal load transfer, as signified by the development of distal femoral cortical hypertrophy. We present the results of a consecutive series of 500 total hip replacements performed between March 2000 and December 2005 at a single institution, using a standard surgical technique and third generation cementing with Palacos-R antibiotic loaded cement. Data was collected prospectively and the patients remain under annual follow-up. 500 arthroplasties were performed on 455 patients with an average age of 68.3 years (23–92). 77 patients have died (73 arthroplasties) and the average duration of follow-up for the entire series is 81 months (52–124).Introduction
Materials/Methods
Traditionally the use of small diameter femoral head (22mm) with the posterior approach has been perceived as an increased risk of dislocation. We present this prospective study of 400 consecutive total hip replacements performed using a 22mm femoral head and the posterior approach. Between March 2000 and November 2005 364 patients underwent 400 total hip replacements with a small diameter 22mm head under the care of four different consultants, using a standard posterior approach. All of the femoral implants were cemented using modular C-stems (Depuy Ltd.) and all of the acetabular components were cemented flanged monobloc all-polyethylene components with long posterior wall with a third generation cementing technique. A standard posterior approach was used in all cases, with direct repair of the capsule and short external rotators.Introduction
Materials/Methods
Success of TKR depends upon soft tissue balance and component alignment. The alteration of quadriceps mechanism while approaching knee for TKR can affect outcome of the surgery. To analyse the results of Trivector retaining arthrotomy for TKRIntroduction
Aim