Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 7 - 7
12 Dec 2024
Shah D Shah A
Full Access

Introduction

Instability in ACL deficient knees can lead to medial compartment osteoarthritis. The risk of developing significant OA is 5x higher in knees with ACL deficiency. In associated Varus, there is quicker progression of the medial OA along with a varus thrust exerting strain on the ACL graft.

The simultaneous valgus HTO and ACL reconstruction decompresses the medial tibiofemoral joint, corrects the mechanical-axis and reduces strain on the graft. Outcomes for this simultaneous procedure are still unclear in literature and we attempt evaluating its functional outcome.

Methods

This Panel study was performed using data from 2019 to 2022 on 21 patients who had ACL insufficiency with Varus or medial OA and underwent a simultaneous Opening-wedge HTO with Arthroscopic ACL reconstruction. The mean follow-up was 2 years. The patients were evaluated with IKDC and Lysholm scores, Lachman test and ROM pre and post-operatively. The HKA was compared pre and post-operatively and the complications were evaluated. The progression of OA was evaluated with serial radiographs post-operatively.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 16 - 16
12 Dec 2024
Shah D Shah A
Full Access

Introduction & Aim

During TKR it is mandatory to achieve perfect soft tissue balance and component alignment. It is necessary to access all tight structures for proper releases. We aim to analyze the results of Trivector arthrotomy approach for TKRs.

Methods

It is a retrospective study of 1050 cases between 2010-2020. All cases were performed by a single surgeon. Approach includes dividing distal 30% of vastus medialis along with medial retinaculum - 1cm medial to patella and patellar tendon distally up to Tibial tuberosity and raised as a single flap.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_20 | Pages 5 - 5
12 Dec 2024
Shah D Shah A
Full Access

Introduction & Aim

The use of All-Poly Tibia has been in practice since the early 1970's. Recently due to the reports on wear and osteolysis in other articulations, this component has generated significant interest. In the current study we aim to report early medium-term results of All-poly Tibial components in elderly (>70 years) patients.

Method

Study of 455 cases done between 2005-2020. All the cases were performed by a single surgeon. All-Poly Tibial component implantations were performed using Standard mechanical jigs and the same posterior-stabilized implant was used for all cases.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 3 - 3
17 Apr 2023
Taylan O Shah D Dandois F Han W Neyens T Van Overschelde P Scheys L
Full Access

Mechanical alignment (MA) in total knee arthroplasty (TKA), although considered the gold standard, reportedly has up to 25% of patients expressing post-operative dissatisfaction. Biomechanical outcomes following kinematic alignment (KA) in TKA, developed to restore native joint alignment, remain unclear. Without a clear consensus for the optimal alignment strategy during TKA, the purpose of this study was to conduct a paired biomechanical comparison of MA and KA in TKA by experimentally quantifying joint laxity and medial collateral ligament (MCL) strain.

14 bilateral native fresh-frozen cadaveric lower limbs underwent medially-stabilised TKA (GMK Sphere, Medacta, Switzerland) using computed CT-based subject-specific guides, with KA and MA performed on left and right legs, respectively. Each specimen was subjected to sensor-controlled mediolateral laxity tests. A handheld force sensor (Mark-10, USA) was used to generate an abduction-adduction moment of 10Nm at the knee at fixed flexion angles (0°, 30°, 60°, 90°). A digital image correlation system was used to compute the strain on the superficial medial collateral ligament. A six-camera optical motion capture system (Vicon MX+, UK) was used to acquire kinematics using a pre-defined CT-based anatomical coordinate system. A linear mixed model and Tukey's posthoc test were performed to compare native, KA and MA conditions (p<0.05).

Unlike MA, medial joint laxity in KA was similar to the native condition; however, no significant difference was found at any flexion angle (p>0.08). Likewise, KA was comparable with the native condition for lateral joint laxity, except at 30°, and no statistical difference was observed. Although joint laxity in MA seemed lower than the native condition, this difference was significant only for 30° flexion (p=0.01). Both KA and MA exhibited smaller MCL strain at 0° and 30°; however, all conditions were similar at 60° and 90°.

Medial and lateral joint laxity seemed to have been restored better following KA than MA; however, KA did not outperform MA in MCL strain, especially after mid-flexion. Although this study provides only preliminary indications regarding the optimal alignment strategy to restore native kinematics following TKA, further research in postoperative joint biomechanics for load bearing conditions is warranted.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 463 - 463
1 Sep 2009
Dakhil-Jerew F Haleem S Jadeja H Bowman N Shah D Cohen A El-Metwally A Guy R Selmon G Shepperd J
Full Access

Introduction: In this study, we report interobserver reliability of X-ray for the interpretation of pedicle screw osteointegration based on the diagnosis of “Halo zone” surrounding the screw.

Dynamic stabilisation system for the spine relies on titanium screw purchase within the pedicle. Decision on osteointegration is important especially when the patient becomes symptomatic following initial good outcome. From our cohort of 420 Dynesys patients, over all incidence of screw loosening was 17%. Only 35% were symptomatic.

Method: Lumbar spine X-ray images of 50 patients in two views (AP and lateral) randomly selected from our cohort of 420 Dynesys patients. The images were deployed in a CD-ROM. The authors were asked to review the images and state whether or not each pedicle screw is loose (total of 258 pedicle screws).

Seven observers composed of two expert orthopaedic spine consultant surgeons and one spine expert consultant radiologist and four Specialist Registrars in orthopaedics and radiology.

Data gathered were distributed and presented in tables in the form of descriptive statistics. The evaluation of interobserver agreement was performed by obtaining a Kappa (K) index. For continuous variables comparison, the t test was employed, with a significance level of 0.05.

Results: Kappa Index among three experts was 0.2198 at 95% CI (−0.0520, 0.4916) while for all 7 assessors (3 Experts & 4 SpR), KI was 0.1462 at 95% CI (0.0332, 0.2592)

Discussion & Conclusion: Kappa Index among expert assessors was 0.2 which means X-ray is unreliable for the assessment of pedicle screw osteointegration. Validity of X-ray is not applicable as it is unreliable.

We are planning to evaluate a 3D computer reconstruction model based on 2 X-ray views at 45 degree angle to each other which might be sensitive to detect screw loosening.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 476 - 476
1 Sep 2009
Dakhil-Jerew F Jadeja H Bowman N Shah D Cohen A El-Metwally A Guy R Selmon G Shepperd J
Full Access

Introduction: In this study, we report interobserver reliability of X-ray for the interpretation of pedicle screw osteointegration based on the diagnosis of “Halo zone” surrounding the screw.

Dynamic stabilisation system for the spine relies on titanium screw purchase within the pedicle. Decision on osteointegration is important especially when the patient becomes symptomatic following initial good outcome. From our cohort of 420 Dynesys patients, over all incidence of screw loosening was 17%. Only 35% were symptomatic.

Method: Lumbar spine X-ray images of 50 patients in two views (AP and lateral) randomly selected from our cohort of 420 Dynesys patients. The images were deployed in a CD-ROM. The authors were asked to review the images and state whether or not each pedicle screw is loose (total of 258 pedicle screws).

Seven observers composed of two expert orthopaedic spine consultant surgeons and one spine expert consultant radiologist and four Specialist Registrars in orthopaedics and radiology.

Data gathered were distributed and presented in tables in the form of descriptive statistics. The evaluation of interobserver agreement was performed by obtaining a Kappa (K) index. For continuous variables comparison, the t test was employed, with a significance level of 0.05.

Results: Kappa Index among three experts was 0.2198 at 95% CI (−0.0520, 0.4916) while for all 7 assessors (3 Experts & 4 SpR), KI was 0.1462 at 95% CI (0.0332, 0.2592)

Discussion & Conclusion: Kappa Index among expert assessors was 0.2 which means X-ray is unreliable for the assessment of pedicle screw osteointegration. Validity of X-ray is not applicable as it is unreliable.

We are planning to evaluate a 3D computer reconstruction model based on 2 X-ray views at 45 degree angle to each other which might be sensitive to detect screw loosening.