Advertisement for orthosearch.org.uk
Results 1 - 20 of 86
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 20 - 20
17 Jun 2024
Jagani N Harrison W Davenport J Karski M Ring J Smith R Clough T
Full Access

Aims

Retrospective review of a consecutive series of 1,168 total ankle replacements (TAR) performed at Wrightington, to analyse modes of failure and clinical outcomes following TAR failure.

Methods

All patients undergoing TAR between November 1993 – June 2019 were collated (4–25 year follow-up; mean 13.7 years). 6 implants were used (300 STAR, 100 Buechal Pappas, 509 Mobility, 118 Zenith, 41 Salto and 100 Infinity). 5 surgeons, all trained in TAR, performed the surgery. Modes of failure were collated and clinical and radiological outcomes recorded for the revisional surgery following failure of the TAR.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 2 - 2
4 Jun 2024
Townshend D Bing A Clough T Sharpe I Blundell C Davenport J Davies H Davis J Dhar S Goldberg A Karski M Hepple S Kakwani R McKinley J Murty A Ragland M Shalaby H Smith R Taylor H
Full Access

Introduction

This is a multi-centre, prospective, observational study of 503 INFINITY fixed bearing total ankle arthroplasties. We report the minimum two-year results of this prosthesis which was introduced to the UK Market in 2014 and is now the most used ankle arthroplasty in the National Joint Registry of England and Wales.

Methods

Patients were recruited from 11 centres in the United Kingdom between June 2016 and November 2019. Demographic, radiographic, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Foot Ankle Questionnaire and Euroquol 5D-5L) were collected preoperatively, at 6 months, 1 year and 2 years and 5 years. The average age was 67.8 (range 23.9 to 88.5) and average BMI 29.3 (18.9 to 48.0). The COFAS grading system was used to stratify deformity. There were 261 (51.9%) COFAS Type 1, 122 (24.2%) COFAS Type 2, 31 (6.2%) COFAS 3 and 89 (17.7%) COFAS type 4. 38 patients (7.6%) presented with inflammatory arthritis. 99 (19.7%) implantations utilised patient specific instrumentation. Complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts and/or subsidence.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 122 - 122
11 Apr 2023
Chen L Zheng M Chen Z Peng Y Jones C Graves S Chen P Ruan R Papadimitriou J Carey-Smith R Leys T Mitchell C Huang Y Wood D Bulsara M Zheng M
Full Access

To determine the risk of total knee replacement (TKR) for primary osteoarthritis (OA) associated with overweight/obesity in the Australian population.

This population-based study analyzed 191,723 cases of TKR collected by the Australian Orthopaedic Association National Joint Registry and population data from the Australian Bureau of Statistics. The time-trend change in incidence of TKR relating to BMI was assessed between 2015-2018. The influence of obesity on the incidence of TKR in different age and gender groups was determined. The population attributable fraction (PAF) was then calculated to estimate the effect of obesity reduction on TKR incidence.

The greatest increase in incidence of TKR was seen in patients from obese class III. The incidence rate ratio for having a TKR for obesity class III was 28.683 at those aged 18-54 years but was 2.029 at those aged >75 years. Females in obesity class III were 1.7 times more likely to undergo TKR compared to similarly classified males. The PAFs of TKR associated with overweight or obesity was 35%, estimating 12,156 cases of TKR attributable to obesity in 2018. The proportion of TKRs could be reduced by 20% if overweight and obese population move down one category.

Obesity has resulted in a significant increase in the incidence of TKR in the youngest population in Australia. The impact of obesity is greatest in the young and the female population. Effective strategies to reduce the national obese population could potentially reduce 35% of the TKR, with over 10,000 cases being avoided.


Proximal femoral focal deficiency is a congenital disorder of malformation of the proximal femur and/or the acetabulum. Patients present with limb length discrepancy and clinical features along a spectrum of severity. As these patients progress through to skeletal maturity and on to adulthood, altered biomechanical demands lead to progression of arthropathy in any joint within the lower limb. Abnormal anatomy presents a challenge to surgeons and conventional approaches and implants may not necessarily be applicable.

We present a case of a 62-year-old lady with unilateral proximal femoral focal deficiency (suspected Aitken Class A) who ambulated with an equinus prosthesis for her entire life. She presented with ipsilateral knee pain and instability due to knee arthritis but could not tolerate a total knee arthroplasty due to poor quadriceps control.

A custom osteointegration prosthesis was inserted with a view to converting to the proximal segment to a total hip replacement if required. The patient went on to develop ipsilateral symptomatic hip arthritis but altered acetabular anatomy required a custom tri-flange component (Ossis, Christchurch, New Zealand) and a custom proximal femoral component to link with the existing osseointegration component (Osseointegration Group of Australia, Sydney, Australia) were designed and implanted.

The 18 month follow up of the custom hip components showed that the patient had Oxford hip scores that were markedly improved from pre-operatively. Knee joint heights were successfully restored to equal when the patient's prosthesis was attached. The patient describes feeling like “a normal person”, walks unaided for short distances and can ambulate longer distances with crutches.

Advances in design and manufacture of implants have empowered surgeons to offer life improving treatments to patients with challenging anatomy. Using a custom acetabular tri-flange and osseointegration components is one possible solution to address symptomatic ipsilateral hip and knee arthropathy in the context of PFFD in adulthood.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 4 - 4
10 Feb 2023
Sundaram A Hockley E Hardy T Carey Smith R
Full Access

Rates of prosthetic joint infection in megaprostheses are high. The application of silver ion coating to implants serves as a deterrent to infection and biofilm formation.

A retrospective review was performed of all silver-coated MUTARS endoprosthetic reconstructions (SC-EPR) by a single Orthopaedic Oncology Surgeon. We examined the rate of component revision due to infection and the rate of infection successfully treated with antibiotic therapy. We reviewed overall revision rates, sub-categorised into the Henderson groupings for endoprosthesis modes of failure (Type 1 soft tissue failure, Type 2 aseptic loosening, Type 3 Structural failure, Type 4 Infection, Type 5 tumour progression).

283 silver-coated MUTARS endoprosthetic reconstructions were performed for 229 patients from October 2012 to July 2022. The average age at time of surgery was 58.9 years and 53% of our cohort were males. 154 (71.3%) patients underwent SC-EPR for oncological reconstruction and 32 (14.8%) for reconstruction for bone loss following prosthetic joint infection(s). Proximal femur SC-EPR (82) and distal femur (90) were the most common procedures. This cohort had an overall revision rate of 21.2% (60/283 cases). Component revisions were most commonly due to Type 4 infection (19 cases), Type 2 aseptic loosening/culture negative disease (15 cases), and Type 1 dislocation/soft tissue (12 cases).

Component revision rate for infection was 6.7% (19 cases). 15 underwent exchange of implants and 4 underwent transfemoral amputation due to recalcitrant infection and failure of soft tissue coverage. This equates to a limb salvage rate of 98.3%. The most common causative organisms remain staphylococcus species (47%) and polymicrobial infections (40%).

We expand on the existing literature advocating for the use of silver-coated endoprosthetic reconstructions. We provide insights from the vast experience of a single surgeon when addressing patients with oncological and bone loss-related complex reconstruction problems.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 1 - 1
10 Feb 2023
Sundaram A Perianayagam G Hong A Mar J Lo H Lawless A Carey Smith R
Full Access

The Australia and New Zealand Sarcoma Association established the Sarcoma Guidelines Working Party to develop national guidelines for the management of Sarcoma. We asked whether surgery at a specialised centre improves outcomes. A systematic review was performed of all available evidence pertaining to paediatric or adult patients treated for bone or soft tissue sarcoma at a specialised centre compared with non-specialised centres. Outcomes assessed included local control, limb salvage rate, 30-day and 90-day surgical mortality, and overall survival.

Definitive surgical management at a specialised sarcoma centre improves local control as defined by margin negative surgery, local or locoregional recurrence, and local recurrence free survival. Limb conservation rates are higher at specialised centres, due in part to the depth of surgical experience and immediate availability of multidisciplinary and multimodal therapy. A statistically significant correlation did not exist for 30-day and 90-day mortality between specialised centres and non-specialised centres. The literature is consistent with improved survival when definitive surgical treatment is performed at a specialised sarcoma centre.

Evidence-based recommendation: Patients with suspected sarcoma to be referred to a specialised sarcoma centre for surgical management to reduce the risk of local recurrence, surgical complication, and to improve limb conservation and survival.

Practice point: Patients with suspected sarcoma should be referred to a specialised sarcoma centre early for management including planned biopsy.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 3 - 3
10 Feb 2023
Sundaram A Woods J Clifton L Alt V Clark R Carey Smith R
Full Access

Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany).

At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both patients remain asymptomatic. 3 patients were readmitted for dislocations, 1 of whom had 5 dislocations within 3 weeks post-operatively and was immobilised in an abduction brace to address a lack of muscle tone and has not had a revision of their components.

Utilising navigation with meticulous implant design and construction; augmented with an ultrathin plasma coating of silver particles embedded between layers of siloxane with controlled and long-term generation of silver ion diffusion has led to outstanding outcomes in this series of 12 custom acetabular and hemipelvis reconstructions. No patients were revised for infection and no patients show signs of failure of bone on growth and incorporation. Hip instability remains a problem in these challenging mechanical environments and we continue to reassess our approach to this multifaceted problem.


Bone & Joint Open
Vol. 3, Issue 5 | Pages 415 - 422
17 May 2022
Hillier-Smith R Paton B

Aims

Avulsion of the proximal hamstring tendon origin can result in significant functional impairment, with surgical re-attachment of the tendons becoming an increasingly recognized treatment. The aim of this study was to assess the outcomes of surgical management of proximal hamstring tendon avulsions, and to compare the results between acute and chronic repairs, as well as between partial and complete injuries.

Methods

PubMed, CINAHL, SPORTdiscuss, Cochrane Library, EMBASE, and Web of Science were searched. Studies were screened and quality assessed.


Bone & Joint Open
Vol. 1, Issue 7 | Pages 438 - 442
22 Jul 2020
Stoneham ACS Apostolides M Bennett PM Hillier-Smith R Witek AJ Goodier H Asp R

Aims

This study aimed to identify patients receiving total hip arthroplasty (THA) for trauma during the peak of the COVID-19 pandemic in the UK and quantify the risks of contracting SARS-CoV-2 virus, the proportion of patients requiring treatment in an intensive care unit (ICU), and rate of complications including mortality.

Methods

All patients receiving a primary THA for trauma in four regional hospitals were identified for analysis during the period 1 March to 1 June 2020, which covered the current peak of the COVID-19 pandemic in the UK.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 116 - 121
1 Jul 2020
Heise G Black CM Smith R Morrow BR Mihalko WM

Aims

This study aimed to determine if macrophages can attach and directly affect the oxide layers of 316L stainless steel, titanium alloy (Ti6Al4V), and cobalt-chromium-molybdenum alloy (CoCrMo) by releasing components of these alloys.

Methods

Murine peritoneal macrophages were cultured and placed on stainless steel, CoCrMo, and Ti6Al4V discs into a 96-well plate. Cells were activated with interferon gamma and lipopolysaccharide. Macrophages on stainless steel discs produced significantly more nitric oxide (NO) compared to their control counterparts after eight to ten days and remained elevated for the duration of the experiment.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 101 - 101
1 Feb 2020
Abbruzzese K Byrd Z Smith R Valentino A Yanoso-Scholl L Harrington MA Parsley B
Full Access

Introduction

Total hip arthroplasty (THA) is a physically demanding procedure where the surgeon is subject to fatigue with increased energy expenditure comparable to exercise[1]. Robotic technologies have been introduced into operating rooms to assist surgeons with ergonomically challenging tasks and to reduce overall physical stress and fatigue[2]. Greater exposure to robotic assisted training may create efficiencies that may reduce energy expenditure[3]. The purpose of this study was to assess surgeon energy expenditure during THA and perceived mental and physical demand.

Methods

12 THAs (6 cadavers) randomized by BMI were performed by two surgeons with different robotic assisted experience. Surgeon 1 (S1) had performed over 20 robotic assisted THAs on live patients and Surgeon 2 (S2) had training on 1 cadaver with no patient experience. For each cadaver, laterality was randomized and manual total hip arthroplasty (MTHA) was performed first on one hip and robotic assisted total hip arthroplasty (RATHA) on the contralateral hip. A biometric shirt collected surgeon data on caloric energy expenditure (CEE) throughout acetabular reaming (AR) and acetabular implantation (AI) for each THA procedure. Surgeon mental and physical demand was assessed after each surgery. Scores were reported from 1–10, with 10 indicating high demand. A paired sample t-test was performed between MTHA and RATHA within each surgeon group with a confidence interval of (α =0.05).


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1179 - 1183
1 Oct 2019
Parsons N Carey-Smith R Dritsaki M Griffin X Metcalfe D Perry D Stengel D Costa M


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_7 | Pages 12 - 12
1 May 2019
Hall A Farrow L Aucott L Smith R Holt G Myint P
Full Access

Hip fracture care is complex multi-disciplinary. We hypothesise that quality of care is affected by variance in resources between ‘in-hours’ (Monday-Friday, 0800–1700) and ‘out-of-hours’ services.

This prospective multicentre national cohort study assessed quality of care by evaluating adherence to the evidence-based Scottish Standards of Care for Hip Fracture Patients. Data was collected by the Scottish Hip Fracture Audit for 15174 patients admitted to any of 22 Scottish hospitals from January 2014-April 2018.

11197/15174 (73.8%) patients were admitted out-of-hours. They were significantly less likely to meet the following Standards: ED Big-6-Bundle (OR 0.85, p= 0.002); Time in ED <4 hours (OR 0.76, p< 0.001); avoidance of repeated fasting (OR 0.80, p< 0.001), and avoidance of prolonged fluid fasting (OR 0.83, p< 0.001). Out-of-hours admissions were more likely to receive: geriatric assessment <3 days (OR 1.16, p< 0.001); OT input <3 days (OR 1.10, p= 0.013), and PT input <2 days (OR 1.44, p< 0.001). There were no significant differences for: Time to Theatre <36 hours; Inpatient Care Bundle <24 hours, and Post-op Day 1 Mobilisation.

Quality of hip fracture care is affected by time of admission. ED care is poorer out-of-hours, which may reflect limited resources, and out-of-hours admissions are more likely to be excessive fasted excessively. Weekday in-hours admissions are less likely to receive geriatric and allied health professional input in the days following admission, which may reflect the reduced weekend services. Examination of out-of-hours service organisation is required for the pursuit of consistent, equitable care for hip fracture patients.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_21 | Pages 25 - 25
1 Dec 2017
Ring J Davenport J Karski M Smith R Divercha H Clough T
Full Access

Introduction

Traditional treatment for end-stage ankle arthritis has been ankle arthrodesis, however ankle arthroplasty is becoming an accepted alternative.

The Zenith Ankle (Corin, UK) is 3rd generation implant with a mobile bearing design. In the NJR 2016 report, the Zenith was the commonest ankle prosthesis implanted in the UK. However, compared to other ankle implants, there's little published data on its performance and survival. The aim of this study was to analyse outcome in a consecutive series from a non-designer centre.

Method

We conducted a retrospective review of a consecutive series of 118 Zenith Ankle replacements implanted in our Unit (December 2010 to May 2016). Data was collected from our National Joint Registry entries, research databases, patient notes, PACS and PROMS.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 7 - 7
1 May 2016
Griffiths J Abouel-Enin S Yates P Carey-Smith R Quaye M Latham J
Full Access

In a society whereby the incidence of obesity is increasing and medico-legal implications of treatment failure are more frequently ending with the consulting doctor, clarity is required as to any restrictions placed on common orthopaedic implants by manufacturing companies. The aim of this study was to identify any restrictions placed on the commonly used femoral stem implants in total hip replacement (THR) surgery, by the manufacturers, based on patient weight. The United Kingdom (UK) National Joint Registry (NJR) was used to identify the five most commonly used cemented and uncemented femoral stem implants during 2012. The manufacturing companies responsible for these implants were asked to provide details of any weight restrictions placed on these implants. The Corail size 6 stem is the only implant to have a weight restriction (60Kg). All other stems, both cemented and uncemented, were free of any restrictions. Fatigue fracture of the femoral stem has been well documented in the literature, particularly involving the high nitrogen stainless steel cemented femoral stems and to a lesser extent the cemented cobalt chrome and uncemented femoral stems. In all cases excessive patient weight leading to increased cantilever bending of the femoral stem was thought to be a major factor contributing to the failure mechanism. From the current literature there is clearly an association between excessive patient weight and fatigue failure of the femoral stem. We suggest avoiding, where possible, the insertion of small stems (particularly cemented stems) and large offset stems (particularly those with a modular neck) in overweight patients.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 30 - 30
1 Dec 2014
Nortje M Hussey D McLennan-Smith R Dymond I Grobler G Dower B Bragdon C Muratoglu O Malchau H
Full Access

Introduction:

The ASR™ Articular Surface Replacement and ASR™ XL Metal-on-Metal systems were recalled due to high revision rates at five years. A worldwide clinical follow-up of patients was initiated. This paper summarizes current findings in South Africa (SA) in comparison with those outside SA (OSA).

Methods:

Patients were followed annually, or until revision, from 10 clinical centers worldwide. Data collected includes demographic, surgical, radiographic, blood metal ion levels, and patient reported outcome measures (PROM).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 3 - 3
1 Nov 2014
Akkena S Karim T Clough T Karski M Smith R
Full Access

Introduction:

The aim of this study was to identify the rate of complications of total ankle replacement in a single Centre to help with informed patient consent.

Methods:

Between 2008 and 2012, 202 total ankle replacements (TARs) were performed by 4 surgeons at our Institute. Data was collected on all patients; demographics, arthritic disease, pre-operative deformity, prosthesis and all early and late complications.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1185 - 1191
1 Sep 2014
Middleton RG Uzoigwe CE Young PS Smith R Gosal HS Holt G

We aimed to determine whether cemented hemiarthroplasty is associated with a higher post-operative mortality and rate of re-operation when compared with uncemented hemiarthroplasty. Data on 19 669 patients, who were treated with a hemiarthroplasty following a fracture of the hip in a nine-year period from 2002 to 2011, were extracted from NHS Scotland’s acute admission database (Scottish Morbidity Record, SMR01). We investigated the rate of mortality at day 0, 1, 7, 30, 120 and one-year post-operatively using 12 case-mix variables to determine the independent effect of the method of fixation. At day 0, those with a cemented hemiarthroplasty had a higher rate of mortality (p < 0.001) compared with those with an uncemented hemiarthroplasty, equivalent to one extra death per 424 procedures. By day one this had become one extra death per 338 procedures. Increasing age and the five-year co-morbidity score were noted as independent risk factors. By day seven, the cumulative rate of mortality was less for cemented hemiarthroplasty though this did not reach significance until day 120. The rate of re-operation was significantly higher for uncemented hemiarthroplasty. Despite adjusting for 12 confounding variables, these only accounted for 15% of the observed variability.

The debate about the choice of the method of fixation for a hemiarthroplasty with respect to the rate of mortality or the risk of re-operation may be largely superfluous. Our results suggest that uncemented hemiarthroplasties may have a role to play in elderly patients with significant co-morbid disease.

Cite this article: Bone Joint J 2014;96-B:1185–91.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 853 - 854
1 Jul 2014
Parsons N Griffin XL Stengel D Carey Smith R Perry DC Costa ML

The Bone & Joint Journal provides the latest evidence to guide the clinical practice of orthopaedic surgeons. The benefits of one intervention compared with another are presented using outcome measures; some may be specific to a limb or joint and some are more general health-related quality of life measures. Readers will be familiar with many of these outcome measures and will be able to judge the relative benefits of different interventions when measured using the same outcome tool; for example, different treatments for pain in the knee measured using a particular knee score. But, how should readers compare outcomes between different clinical areas using different outcome measures? This article explores the use of standardised effect sizes.

Cite this article: Bone Joint J 2014;96-B:853–4.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 22 - 22
1 Jul 2014
Garvican E Cree S Bull L Smith R Dudhia J
Full Access

Summary Statement

Transportation media and injection protocol have implications for the viability of MSCs used for intra-lesional treatment of tendon injuries. Every effort should be made to implant cells within 24h of laboratory re-suspension, using a needle bore larger than 21G.

Introduction

Intra-lesional implantation of autologous mesenchymal stem cells (MSCs) has resulted in significant improvements in tendon healing in experimental animal models. Intra-tendinous injection of MSCs into naturally-occurring equine tendon injuries has been shown to be both safe and efficacious1 and these protocols can assist in the translation to the human. Efficient transfer of cells from the laboratory into the tissue requires well validated techniques for transportation and implantation. The aim of this study was to determine the influence of transport media and injection procedure on cellular damage.