Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 16 - 16
1 Feb 2020
Song S Kang S Park C
Full Access

Background

As life expectancy increases, the number of octogenarians requiring primary and revision total knee arthroplasty (TKA) is increasing. Recently, primary TKA has become a common treatment option in octogenarians. However, surgeons are still hesitant about performing revision TKA on octogenarians because of concerning about risk- and cost-benefit. The purpose of this study was to investigate postoperative complications and mid-term survival in octogenarians following primary and revision total knee arthroplasty (TKA).

Methods

We retrospectively reviewed 231 primary TKAs and 41 revision TKAs performed on octogenarians between 2000 and 2016. The mean age was 81.9 for primary TKA and 82.3 for revision TKA (p=0.310). The American Society of Anesthesiologists (ASA) score was not different, but the age-adjusted Charlson comorbidity index was higher in revision TKA (4.4 vs. 4.8, p=0.003). The mean follow-up period did not differ (3.8 vs. 3.5 years, p=0.451). The WOMAC scores and range of motion (ROM) were evaluated. The incidence of postoperative complication and survival rate (end point; death determined by telephone or mail communication with patient or family) were investigated.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 21 - 21
1 Feb 2020
Park C Kang S Song S
Full Access

Purpose

The purpose of the present study was to evaluate the intercompartmental loads with a sensor placed on implants after conventional gap balancing during total knee arthroplasty (TKA) with a tensiometer.

Methods

Fifty sensor-assisted TKA procedures were performed prospectively between August and September 2018 with a cruciate-retaining prosthesis. After applying a modified measured technique, conventional balancing between the resected surfaces was achieved. The equal and rectangular flexion–extension gaps were confirmed using a tensiometer. Then, the load distribution was evaluated with a sensor.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 15 - 15
1 Feb 2020
Song S Kang S Park C
Full Access

Purpose

Long-term clinical and radiographic results and survival rates were compared between closed-wedge high tibial osteotomy (HTOs) and fixed-bearing unicompartmental knee arthroplasty (UKA) in patients with similar demographics.

Methods

Sixty HTOs and 50 UKAs completed between 1992 and 1998 were retrospectively reviewed. There were no significant differences in preoperative demographics. The mean follow-up period was 10.7 ±5.7 years for HTO and 12.0 ±7.1 years for UKA (n.s.). The Knee Society knee and function scores, WOMAC, and range of motion (ROM) were investigated. The mechanical axis and femorotibial angle were evaluated. Kaplan–Meier survival analysis was performed (failure: revision to TKA), and the failure modes were investigated.


Purpose

The purpose of this study was to compare intercompartmental loads and the proportion of knees with unbalanced loads after tensiometer-assisted balancing (TAB) between cruciate retaining (CR) and posterior stabilized (PS) total knee arthroplasty (TKA).

Materials and Methods

Forty-five CR and 45 PS TKAs using a single prosthesis were prospectively evaluated. The intercompartmental loads in 10°, 45°, and 90° of knee flexion after TAB were evaluated; the proportions of load imbalance (medial load – lateral load >15 lbs) in each flexion angle after TAB were investigated. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of TAB were calculated, with the sensor-balanced loads considered the reference standard.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 98 - 98
1 Apr 2018
Song S Park C Liang H Kang S Bae D
Full Access

Objective

The purpose of the present study was to compare the clinical and radiographic results after TKA using a patellofemoral design modified prosthesis and its predecessor. The other purpose was to investigate whether the use of the recent prosthesis increase the risk of posterior tibial cortex injury or patellar fracture.

Materials and Methods

The clinical and radiographic results of 300 knees which underwent TKA using the Attune®prosthesis (group A) were compared with those in a paired match-control group who underwent TKA using the P.F.C. Sigma® prosthesis (group B). The preoperative demographic data between the 2 groups did not differ significantly. The WOMAC, Feller and Kujala scores, and range of motion (ROM) were compared. The minimal distance between the tibial component stem to posterior tibial cortex, and the remnant patella thickness were compared.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 97 - 97
1 Apr 2018
Song S Liang H Bae D Yoo M Kim K Park C
Full Access

Introduction

Although total knee arthroplasty (TKA) in end-stage hemophilic arthropathy can reduce the severe joint pain and improve the functional disability, it is technically demanding. In addition, it has generally reported a high rate of complication including periprosthetic joint infection (PJI) and component loosening up to 20%. Although the Knee Society classification system of TKA complication was introduced, the complications of TKA in hemophilic arthropathy has not stratified using this classification system in previous articles to the best of our knowledge.

The purpose of this study was to evaluate the mid-term outcomes and complications of TKA in hemophilic arthropathy.

Methods

The study retrospectively reviewed 131 consecutive primary TKAs (102 patients) in single institute. The mean patient age was 41.0 years and mean follow-up time was 6.4 years. The clinical and radiographic results were evaluated. The complications were categorized according to the classification system of the Knee Society for TKA complications.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 99 - 99
1 Apr 2018
Song S Park C Liang H Bae D
Full Access

Background

The knowledge about the common mode of failure and each period in primary and revision TKAs offers useful information to prevent those kinds of failure in each surgery. However, there has been limited report that simultaneously compared the mode of failure between primary and revision TKAs using single prosthesis.

We compared the survival rate, mode of failure, and periods of each mode of failure between primary and revision TKAs.

Methods

A consecutive cohort of 1606 knees (1174 patients) of primary TKA and 258 knees (224 patients) of revision TKA using P.F.C® prosthesis was retrospectively reviewed. The mean follow-up periods of primary and revision TKAs were 10.2 and 10.8 years, respectively. We compared the above variables between primary and revision TKAs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 52 - 52
1 Aug 2013
Ren H Liu W Song S
Full Access

Surgical navigation systems enable surgeons to carry out surgical interventions more accurately and less invasively, by tracking the surgical instruments inside human body with respect to the target anatomy. Currently, optical tracking (OPT) is the gold standard in surgical instrument tracking because of its sub-millimeter accuracy, but is constrained by direct line of sight (LOS) between camera sensors and active or passive markers. Electromagnetic tracking (EMT) is an alternative without the requirement of LOS, but subject to environmental ferromagnetic distortion. An intuitive idea is to integrate respective strengths of them to overcome respective weakness and we aim to develop a tightly-coupled method emphasising the interactive coupled sensor fusion from magnetic and optical tracking data. In order to get real-time position and orientation of surgical instruments in the surgical field, we developed a new tracking system, which is aiming to overcome the constraints of line-of-sight and paired-point interference in surgical environment. The primary contribution of this study is that the LOS and point correspondence problems can be mitigated using the initial measurements of EMT, and in turn the OPT result can provide initial value for non-linear iterative solver of EMT sensing module.

We developed an integrated optical and electromagnetic tracker comprised of custom multiple infrared cameras, optical marker, field generator and sensing coils, because the current commercial optical or magnetic tracker typically consists of unchangeable lower level proprietary hardware and firmware. For the instrument-affixed markers, the relative pose between passive optical markers and magnetic coils is calibrated. The pose of magnetic sensing coils calculated by electromagnetic sensing module, can speed up the extraction of fiducial points and the point correspondences due to the reduced search space. Moreover, the magnetic tracking can compensate the missing information when the optical markers are temporarily occluded. For magnetic sensing subsystem comprised of 3-axis transmitters and 3-axis receiving coils, the objective function for nonlinear pose estimator is given by the summation of the square difference between the measured sensing data and theoretical data from the dipole model. Non-linear optimisation is computational intensive and requires initial pose estimation value. Traditionally, the initial value is calculated by equation-based algorithm, which is sensitive to noise. Instead, we get the initial value from the measurement of optical tracking subsystem. The real-time integrated tracking system was validated to have tracking errors about 0.87mm. The proposed interactive and tightly coupled sensor-fusion of magnetic-optical tracking method is efficient and applicable for both general surgeries as well as intracorporeal surgeries.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 128 - 133
1 Jan 2012
Kim S Agashe MV Song S Choi H Lee H Song H

Lengthening of the humerus is now an established technique. We compared the complications of humeral lengthening with those of femoral lengthening and investigated whether or not the callus formation in the humerus proceeds at a higher rate than that in the femur. A total of 24 humeral and 24 femoral lengthenings were performed on 12 patients with achondroplasia. We measured the pixel value ratio (PVR) of the lengthened area on radiographs and each radiograph was analysed for the shape, type and density of the callus. The quality of life (QOL) of the patients after humeral lengthening was compared with that prior to surgery. The complication rate per segment of humerus and femur was 0.87% and 1.37%, respectively. In the humerus the PVR was significantly higher than that of the femur. Lower limbs were associated with an increased incidence of concave, lateral and central callus shapes. Humeral lengthening had a lower complication rate than lower-limb lengthening, and QOL increased significantly after humeral lengthening. Callus formation in the humerus during the distraction period proceeded at a significantly higher rate than that in the femur.

These findings indicate that humeral lengthening has an important role in the management of patients with achondroplasia.