DDH These methods have been applied to examine systematic variations in the shape and dimensions of the dysplastic femur through reference to data from 171 dysplastic and 84 skeletally normal patients. Of the 171 dysplastic femora, 74 (43%) were graded as Crowe I, 82 (48%) as Crowe stages II or III, and 15 (9%) as Crowe IV. The change in femoral morphology was quantified as a function of the grade of deformity in comparison with normal controls. The principal sources of deformity were also identified. FAI We examined the hypothesis that the femur of patients with femoro-acetbular impingement has multiple morphologic characteristics leading to reduced range of motion. Sixty-six cadaveric femora (30 male and 36 female, average age: 76 years) were selected from a large osteologic collection. Thirteen femora were morphologically normal and 53 were abnormal. Standard morphologic parameters were calculated and normalized with respect to the femoral head diameter. Additional parameters were determined to quantify the head/neck relationship. These included the I angle, the. angle, the anterior offset ratio (OSR), the anterior head-neck ratio, the posterior ‘slip’ of the femoral head, the neck shaft angle and the femoral neck anteversion.
We report the radiological and clinical outcome of a press-fit (SLF) acetabular component at two to three years in two groups of patients having primary total hip replacement. In 69 the implant was coated with hydroxyapatite (HA) and in 40 it was uncoated. The stability of the cup was assessed by measurement of proximal migration and change in the angle of inclination. The clinical results in the two groups did not differ significantly, and the mean proximal linear wear was similar in both. Fewer radiolucent lines (RLLs) were seen on the radiographs of cups coated with HA. The mean proximal migration was studied by calculating regression lines for each patient using migration measurements: for the SLF+HA group the mean slope was 0.06 mm/year and for the SLF–HA group 0.20 mm/year (p = 0.22). The change in the angle of inclination during follow-up was also consistently smaller in HA–coated cups. Using regression methods the SLF+HA group had a mean slope of 0.08°/year and the SLF-HA group 0.44°/year (p = 0.023). Partial HA coating appeared to have no effect on the clinical outcome or on the rate of wear of polyethylene, but there was a trend towards a reduced rate of proximal migration, and a significant reduction in rotational migration and the number of radiolucent lines. This suggests that HA coating enhances the stability of this acetabular component.