The management of periprosthetic distal femur fractures is an issue of increasing importance for orthopaedic surgeons. Because of the expanding indications for total knee arthroplasty (TKA) and an aging population with increasingly active lifestyles there has been a corresponding increase in the prevalence of these injuries. The management of these fractures is often complex because of issues with obtaining fixation around implants and dealing with osteopenic bone or compromised bone stock. In addition, these injuries frequently occur in frail, elderly patients, and the early restoration of function and ambulation is critical in these patients. There remains substantial controversy with respect to the optimal treatment of periprosthetic distal femur fractures, with some advocating for Locked Plating (LP), others Retrograde Intramedullary Nailing (RIMN) and finally those who advocate for Distal Femoral Replacement (DFR). The literature comparing these treatments, has been infrequent, and commonly restricted to single-center studies. The purpose of this study was to retrospectively evaluate a large series of operatively treated periprosthetic distal femur fractures from multiple centers and compare treatment strategies. Patients who were treated operatively for a periprosthetic distal femur fracture at 8 centers across North America between 2003 and 2018 were retrospectively identified. Baseline characteristics, surgical details and post-operative clinical outcomes were collected from patients meeting inclusion criteria. Inclusion criteria were patients aged 18 and older, any displaced operatively treated periprosthetic femur fracture and documented 1 year follow-up. Patients with other major lower extremity trauma or ipsilateral total hip replacement were excluded. Patients were divided into 3 groups depending on the type of fixation received: Locked Plating, Retrograde Intramedullary Nailing and Distal Femoral Replacement. Documented clinical follow-up was reviewed at 2 weeks, 3 months, 6 months and 1 year following surgery. Outcome and covariate measures were assessed using basic descriptive statistics. Categorical variables, including the rate of re-operation, were compared across the three treatment groups using Fisher Exact Test. In total, 121 patients (male: 21% / female: 79%) from 8 centers were included in our analysis. Sixty-seven patients were treated with Locked Plating, 15 with Retrograde Intramedullary Nailing, and 39 were treated with Distal Femoral Replacement. At 1 year, 64% of LP patients showed radiographic union compared to 77% in the RIMN group (p=0.747). Between the 3 groups, we did not find any significant differences in ambulation, return to work and complication rates at 6 months and 1 year (Table 1). Reoperation rates at 1 year were 27% in the LP group (17 reoperations), 16% in the DFR group (6 reoperations) and 0% in the RIMN group. These differences were not statistically significant (p=0.058). We evaluated a large multicenter series of operatively treated periprosthetic distal femur fractures in this study. We did not find any statistically significant differences at 1 year between treatment groups in this study. There was a trend towards a lower rate of reoperation in the Retrograde Intramedullary Nailing group that should be evaluated further with prospective studies. For any figures or tables, please contact the authors directly.
The benefit of using a long intramedullary device for the treatment of geriatric intertrochanteric hip fractures is unknown. The InterTAN device (Smith and Nephew, Memphis TN) is offered in either Short (180–200 mm) or Long (260–460 mm) constructs and was designed to provide stable compression across primary intertrochanteric fracture fragments. The objective of our study was to determine whether Short InterTANs are equivalent to Long InterTANs in terms of functional and adverse outcomes for the treatment of geriatric intertrochanteric hip fractures. 108 patients with OTA classification 31A–1 and 31A–2 intertrochanteric hip fractures were included in our study and prospectively followed at one of four Canadian Level-1 Trauma Centres. Our primary outcomes included two validated primary outcome measures: the Functional Independence Measure (FIM), to measure function, and the Timed Up and Go (TUG), to measure motor performance. Secondary outcome measures included blood loss, length of procedure, length of stay and adverse events. A pre-injury FIM was measured by retrospective recall and all postoperative outcomes were assessed on postoperative day 3, at discharge, at 6 weeks, 3 months, 6 months and 12 months postoperatively. Unpaired t-tests and Chi-square tests were used for the comparison of continuous and categorical variables respectively between the Short and Long InterTAN groups. A statistically significant difference was defined as p<0.05. Our study included 71 Short InterTAN and 37 Long InterTAN patients with 31A–1 and 31A–2 intertrochanteric hip fractures. Age, sex, BMI, side, living status and comorbidities were similar between the two groups. The mean operative time was significantly lower in the Short InterTAN group (61 mins) as compared to the Long InterTAN group (71 mins)(p0.05). There were 5 periprosthetic femur fractures in the short InterTAN group versus 1 in the long InterTAN group. Non-mechanical adverse outcomes such as myocardial infarction, pulmonary embolism, urinary tract infections, pneumonia and death all had similar incidence rates between the two InterTAN groups. Both the Short and Long InterTAN patient cohorts displayed similar improvements in performance and overall function over the course of a year following intertrochanteric hip fracture fixation. The recorded operative times for Short InterTAN fixation were significantly shorter than those recorded for the Long InterTAN patients. Alternatively, a significantly higher proportion of Short InterTAN patients sustained periprosthetic femur fractures within a year of implantation as compared to the Long InterTAN group.
The use of robots in orthopaedic surgery is an
emerging field that is gaining momentum. It has the potential for significant
improvements in surgical planning, accuracy of component implantation
and patient safety. Advocates of robot-assisted systems describe
better patient outcomes through improved pre-operative planning
and enhanced execution of surgery. However, costs, limited availability,
a lack of evidence regarding the efficiency and safety of such systems
and an absence of long-term high-impact studies have restricted
the widespread implementation of these systems. We have reviewed
the literature on the efficacy, safety and current understanding of
the use of robotics in orthopaedics. Cite this article:
To assess the impact of two oral thromboprophylaxis agents against Clexane with regard to range of movement (ROM) following TKR with or without haemostasis following tourniquet release. Thromboprophylaxis choice following total knee replacement (TKR) has become of interest with the introduction of oral anticoagulants and support for these by NICE. Specific concerns with oral agents include a perceived elevated level of anti-coagulation and soft tissue complications. The population (n=264) was subclassified into cohorts regarding thromboprophylaxis cover: Clexane, Rivaroxaban and Dabigatran. Each subgroup was subdivided into whether surgery was performed with or without haemostasis following tourniquet release. This study demonstrates Clexane is associated with a better and earlier return of ROM post-operatively as compared to oral the thromboprophylaxis agents. This effect was more obvious when combined with haemostasis following early tourniquet release (p< 0.05). The oral thromboprophylaxis agents Rivaroxaban and Dabigatran had a relative negative effect on ROM as compared against Clexane. This was independent of whether the surgery was performed with or without haemostasis following tourniquet release. There was no different between the subgroups with repect to change of serum haemoglobin, symptomatic venous thromboembolism or rate of return to theatre.Study Aim
Methods & Results
Open reduction and plate fixation of displaced mid-shaft clavicle fractures has gained significant popularity following a recent multi-center randomized control trial. The purpose of this study is to describe the incidence of reoperation following plate fixation of displaced mid-shaft clavicle fractures. The secondary objective is to determine if plate design influences the incidence of reoperation. A retrospective search of our hospital database was performed to identify subjects treated with plate fixation for a displaced clavicle fracture between 2001 and 2009. Radiographs and medical records were used to identify demographic data, fracture classification, plate design, and reoperation events. Only mid-shaft (AO/OTA 15-B) fractures treated with either a Low-Contact Dynamic Compression (LCDC) plate or Pre-contoured Locking (PCL) plate were included.Purpose
Method