To develop prediction models using machine-learning (ML) algorithms for 90-day and one-year mortality prediction in femoral neck fracture (FNF) patients aged 50 years or older based on the Hip fracture Evaluation with Alternatives of Total Hip arthroplasty versus Hemiarthroplasty (HEALTH) and Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trials. This study included 2,388 patients from the HEALTH and FAITH trials, with 90-day and one-year mortality proportions of 3.0% (71/2,388) and 6.4% (153/2,388), respectively. The mean age was 75.9 years (SD 10.8) and 65.9% of patients (1,574/2,388) were female. The algorithms included patient and injury characteristics. Six algorithms were developed, internally validated and evaluated across discrimination (c-statistic; discriminative ability between those with risk of mortality and those without), calibration (observed outcome compared to the predicted probability), and the Brier score (composite of discrimination and calibration).Aims
Methods
Using tibial shaft fracture participants from a large, multicentre randomized controlled trial, we investigated if patient and surgical factors were associated with health-related quality of life (HRQoL) at one year post-surgery. The Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT) trial examined adults with an open or closed tibial shaft fracture who were treated with either reamed or unreamed intramedullary nails. HRQoL was assessed at hospital discharge (for pre-injury level) and at 12 months post-fracture using the Short Musculoskeletal Functional Assessment (SMFA) Dysfunction, SMFA Bother, 36-Item Short Form 36 (SF-36) Physical, and SF-36 Mental Component scores. We used multiple linear regression analysis to determine if baseline and surgical factors, as well as post-intervention procedures within one year of fracture, were associated with these HRQoL outcomes. Significance was set at p < 0.01. We hypothesize that, irrespective of the four measures used, prognosis is guided by both modifiable and non-modifiable factors and that patients do not return to their pre-injury level of function, nor HRQoL.Aims
Methods
The aims of this study were to quantify health state utility
values (HSUVs) after a tibial fracture, investigate the effect of
complications, to determine the trajectory in HSUVs that result
in these differences and to quantify the quality-adjusted life years
(QALYs) experienced by patients. This is an analysis of 2138 tibial fractures enrolled in the
Fluid Lavage of Open Wounds (FLOW) and Study to Prospectively Evaluate
Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT)
trials. Patients returned for follow-up at two and six weeks and
three, six, nine and 12 months. Short-Form Six-Dimension (SF-6D) values
were calculated and used to calculate QALYs.Aims
Patients and Methods
The primary aim of this prognostic study was to identify baseline
factors associated with physical health-related quality of life
(HRQL) in patients after a femoral neck fracture. The secondary
aims were to identify baseline factors associated with mental HRQL,
hip function, and health utility. Patients who were enrolled in the Fixation using Alternative
Implants for the Treatment of Hip Fractures (FAITH) trial completed
the 12-item Short Form Health Survey (SF-12), Western Ontario and
McMaster Universities Arthritis Index, and EuroQol 5-Dimension at
regular intervals for 24 months. We conducted multilevel mixed models
to identify factors potentially associated with HRQL. Aims
Patients and Methods
In a meta-analysis of fourteen trials (N=1901 patients) in patients with displaced hip fractures, we identified significant reductions in the risk of revision surgery with internal fixation compared to arthroplasty. A trend towards increased mortality with arthroplasty was identified. The purpose of this study was to determine the effect of arthroplasty (hemi-arthroplasty, bipolar arthroplasty and total hip arthroplasty) in comparison to internal fixation for displaced femoral neck fractures on rates of mortality and revision surgery Arthroplasty for displaced femoral neck fractures, in comparison to internal fixation, significantly reduces the risk of revision surgery at the cost of greater infection rates, blood loss and operative time, and a possible increase in early mortality. Over 220,000 fractures of hip occur per year in North America representing an annual seven billion dollar cost to the health care system. Current evidence suggests internal fixation may reduce mortality risk at the consequence of increased revision rates. A large trial is needed to resolve this issue. We searched computerized databases (MEDLINE, COCHRANE and SCISEARCH) for published clinical studies from 1969–2002 and identified additional studies through hand searches of major orthopaedic journals, bibliographies of major orthopaedic texts and personal files. We found a non-significant trend toward an increase in the relative risk of dying with arthroplasty when compared to internal fixation (relative risk=1.27, 95% confidence interval, 0.84–1.92, p = 0.25; homogeneity p= 0.45). Arthroplasty appeared to increase the risk of dying when compared to pin and plate, but not in comparison to internal fixation using screws (relative risk= 1.75 vs 0.86, respectively, p<
0.05). Fourteen trials provided data on revision surgery (n=1901 patients). The relative risk of revision surgery with arthroplasty was 0.23 (95% confidence interval, 0.13–0.42, p = 0.0003, homogeneity p = <
0.01).
We have reviewed our experience of four iatrogenic femoral neck fractures in 315 consecutive closed intramedullary nailings with the AO/ASIF universal femoral nail. The average neck-shaft angle in the bones that fractured was 139.3 degrees +/- 1.2 degrees SD (136 to 141); in the whole series the average neck-shaft angle was 125.3 degrees +/- 8.6 degrees and only 11 had angles of more than 135 degrees. The upper ends of the nails in the four which fractured were 17 mm, 5 mm, 3 mm, and 1 mm below the tip of the greater trochanter. In the seven patients with neck-shaft angles greater than 135 degrees but with no fracture, none of the nails had been inserted beyond the tip of the greater trochanter. We nailed six cadaver femora to simulate the forces produced by intramedullary nailing. Despite deep insertion, only one of the six sustained a neck fracture. This specimen had a radiographic neck-shaft angle of 140 degrees against an average of 127.3 degrees +/- 4.0 degrees for the other five. We believe that the medial prong of the AO insertion jig, with its medial overhang of 2 to 3 mm, may impinge on the superior aspect of a valgus femoral neck during final impaction, causing a neck fracture. This may be avoided by leaving the end of the nail above the tip of the trochanter in such cases.
We report four cases of fracture of the cuboid treated by open reduction, bone grafting where necessary and internal fixation. We recommend this treatment where there is appreciable displacement of one or more of the articular surfaces. The preliminary results were better than those previously reported for conservative treatment or for later midtarsal fusion.