Accurate assessment of alignment in pre-operative and post-operative knee radiographs is important for planning and evaluating knee replacement surgery. Existing methods predominantly rely on manual measurements using long-leg radiographs, which are time-consuming to perform and are prone to reliability errors. In this study, we propose a machine-learning-based approach to automatically measure anatomical varus/valgus alignment in pre-operative and post-operative standard AP knee radiographs. We collected a training dataset of 816 pre-operative and 457 one-year post-operative AP knee radiographs of patients who underwent knee replacement surgery. Further, we have collected a separate distinct test dataset with both pre-operative and one-year post-operative radiographs for 376 patients. We manually outlined the distal femur and the proximal tibia/fibula with points to capture the knee joint (including implants in the post-operative images). This included point positions used to permit calculation of the anatomical tibiofemoral angle. We defined varus/valgus as negative/positive deviations from zero. Ground truth measurements were obtained from the manually placed points. We used the training dataset to develop a machine-learning-based automatic system to locate the point positions and derive the automatic measurements. Agreement between the automatic and manual measurements for the test dataset was assessed by intra-class correlation coefficient (ICC), mean absolute difference (MAD) and Bland-Altman analysis.Introduction
Method
The aim of this study was to compare outcomes after growth-friendly treatment for early-onset scoliosis (EOS) between patients with skeletal dysplasias versus those with other syndromes. We retrospectively identified 20 patients with skeletal dysplasias and 292 with other syndromes (control group) who had completed surgical growth-friendly EOS treatment between 1 January 2000 and 31 December 2018. We compared radiological parameters, complications, and health-related quality of life (HRQoL) at mean follow-up of 8.6 years (SD 3.3) in the dysplasia group and 6.6 years (SD 2.6) in the control group.Aims
Methods
Disability and slow return to sport and work after tendon rupture are major challenges. Platelet Rich Plasma (PRP) is an autologous supraphysiological concentration of platelets from whole blood that has demonstrated positive cellular and physiological effects on healing in laboratory conditions but evidence from adequately powered robust clinical trials is lacking. We aimed to determine the clinical efficacy of PRP for treatment of acute Achilles tendon rupture. In a placebo-controlled, participant- and assessor-blinded, trial at 19 NHS hospitals we randomly assigned 230 adults starting acute Achilles rupture non-surgical management to PRP injection or dry-needle insertion (placebo) to the rupture gap under local anaesthetic. Patients with confounding or contraindicated concurrent medical conditions were excluded. The primary outcome was muscle-tendon function, assessed by the limb symmetry index (LSI, uninjured limb/injured limb × 100, higher scores better) of the work (Joules) performed during the heel-rise endurance test at 24 weeks. Secondary outcomes were: Achilles Tendon Rupture Score (ATRS, 0–100, higher scores better), quality of life (SF-12), pain, and goal attainment. Trial registration: ISRCTN54992179Background
Methods
Management of deformity involving limb length discrepancy (LLD) using intramedullary devices offers significant benefits to both patients and clinicians over traditional external fixation. Following the withdrawal of the PRECICE nail, the Fitbone became the primary implant available for intramedullary lengthening and deformity correction within our service. This consecutive series illustrates the advantages and complications associated with the use of this device, and describes a novel technique modification for antegrade intramedullary lengthening nails. A retrospective cohort review was performed of patient outcomes after treatment with the Fitbone nail at two tertiary referral limb reconstruction services (one adult, one paediatric) between January 2021 to December 2023. Aetiology, indications, initial and final LLD, use of concomitant rail assisted deformity correction (ORDER), removal time and healing index were assessed. Complications of treatment were evaluated and described in detail, alongside technique modifications to reduce the rate of these complications.Introduction
Materials & Methods
In 2021 the bone grafting market was worth €2.72 billion globally. As allograft bone has a limited supply and risk of disease transmission, the demand for synthetic grafting substitutes (BGS) continues to grow while allograft bone grafts steadily decrease. Synthetic BGS are low in mechanical strength and bioactivity, inspiring the development of novel grafting materials, a traditionally laborious and expensive process. Here a novel BGS derived from sustainably grown coral was evaluated. Coral-derived scaffolds are a natural calcium carbonate bio-ceramic, which induces osteogenesis in bone marrow mesenchymal stem cells (MSCs), the cells responsible for maintaining bone homeostasis and orchestrating fracture repair. By 3D printing MSCs in coral-laden bioinks we utilise high throughput (HT) fabrication and evaluation of osteogenesis, overcoming the limitations of traditional screening methods. MSC and coral-laden GelXA (CELLINK) bioinks were 3D printed in square bottom 96 well plates using a CELLINK BIO X printer with pneumatic adapter Samples were non-destructively monitored during the culture period, evaluating both the sample and the culture media for metabolism (PrestoBlue), cytotoxicity (lactose dehydrogenase (LDH)) and osteogenic differentiation (alkaline phosphatase (ALP)). Endpoint, destructive assays used included qRT-PCR and SEM imaging. The inclusion of coral in the printed bioink was biocompatable with the MSCs, as reflected by maintained metabolism and low LDH release. The inclusion of coral induced osteogenic differentiation in the MSCs as seen by ALP secretion and increased RUNX2, collagen I and osteocalcin transcription. Sustainably grown coral was successfully incorporated into bioinks, reproducibly 3D printed, non-destructively monitored throughout culture and induced osteogenic differentiation in MSCs. This HT fabrication and monitoring workflow offers a faster, less labour-intensive system for the translation of bone substitute materials to clinic.
Children with osteogenesis imperfecta (OI) frequently present with coxa vara (CV). Skeletal fragility, severe deformity and limited fixation options make this a challenging condition to correct surgically. Our study aimed to determine the efficacy of the Fassier technique to correct CV and determine the complication rate. Retrospective, descriptive case series from a tertiary hospital. We retrospectively reviewed records of a cohort of eight children (four females, 12 hips) with OI (6/8 Sillence type III, 2/8 type IV) who had surgical treatment with Fassier technique for CV between 2014 and 2020. Inclusion Criteria: All patients with CV secondary to OI treated surgically with Fassier technique. Exclusion Criteria: Patients older than 18 years; Patients with CV treated non-operatively or by surgical technique different to Fassier technique. Data relating to the following parameters was collected and analyzed: demographic data, pre- and postoperative neck shaft angle (NSA), complications and NSA at final follow-up. The mean age at operation was 5.8 years (range 2–10). The mean NSA was corrected from 96.8° preoperatively to 137º postoperatively. At a mean follow-up of 38.6 months, the mean NSA was maintained at 133°, and 83% (10/12) of hips had an NSA that remained greater than 120°. There was a 42% (5/12) complication rate: three Fassier–Duval rods failed to expand after distal epiphyseal fixation was lost during growth; one Rush rod migrated through the lateral proximal femur cortex with recurrent coxa vara; and one Rush rod migrated proximally and required rod revision. The Fassier technique effectively corrected CV in children with moderate and progressively deforming OI. The deformity correction was maintained in the short term. The complication rate was high, but mainly related to the failed expansion of the Fassier–Duval rods.
Osteochondral allograft (OCA) transplantation is a clinically and cost-effective option for symptomatic cartilage defects. In 2017 we initiated a program for OCA transplantation for complex chondral and osteochondral defects as a UK tertiary referral centre. To characterise the complications, re-operation rate, graft survivorship and clinical outcomes of knee OCA transplantation.Abstract
Background
Aim
The Montgomery ruling advocates patients be informed of ‘material risks’ of a procedure. With no guidelines for patients wishing to return to high activity levels after knee arthroplasty, we explore patient and surgeon perceptions in climbers. Ethical approval was granted by the University of Central Lancashire. Anonymous questionnaires were sent via email and social media to consultant knee arthroplasty surgeons and to climbers/mountaineers across the UK. Consultants were asked about advice given for patients who participate in climbing. Climbers were asked about their experiences of knee arthroplasty and return to activity. Of 33 knee arthroplasty surgeons, 11(33%) were firmly against any return to climbing, 10(30%) counselled against it, and 12(36%) were open to return to previous activity. Of 11(33%) surgeons who do not gather information about levels of climbing, 8 would not provide specific advice regarding risks of returning to sport. Of 28 climbers, only 5(18%) were informed to cease completely, with 11(39%) cautioned against and 12(43%) permitted to return. There was no correlation between the advice received and climbing ability post-operatively, (kappa=0.143,p=0.058), with a substantial agreement between ability 1-year post-operatively and currently, (kappa=0.689,p<0.001). There is a discrepancy between the advice given and received by climbers/mountaineers prior to knee arthroplasty, with ability post-operatively having no relationship to advice given. Climbing is possible at high level with no reported complications following knee arthroplasty. The 1-year time point is predictive of longer-term outcome. This information should help surgeons better inform their patients preoperatively.Abstract
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMD. 119 patients were randomized to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years comparing the unoperated contralateral femur as a control. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% in the mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. Implant design was shown to impact BMD changes. All stems preserved bone at the metaphyseal level in early follow-up, which theoretically indicates favorable implant fixation. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship.
Climbers and mountaineers will present to arthroplasty surgeons in need of hip replacement surgeries. There is a lack of guidance for both parties with a paucity in the literature. Climbing is often considered a high-risk activity to perform with a total hip replacement, due to the positions the hip is weighted in, and the potential austere environment in which an injury may occur. The aim was to assess levels of climbing and mountaineering possible following hip arthroplasty, and any factors affecting these levels. Ethical approval was obtained from the University of Central Lancashire. An anonymous online questionnaire was disseminated via email, social media and word-of-mouth to include all climbers, hill-walkers or mountaineers across the UK. This was used to collect climbing and mountaineering ability at various timepoints, along with scores such as the Oxford Hip Score and UCLA Score. The Kappa statistic was used to assess for correlations. Of the responders, 28 had undergone right hip arthroplasty surgery, with 11 having left hips and 22 receiving bilateral hips. A total of 67 of the replaced hips were total hip replacements, with 16 having undergone hip resurfacing. There is a fair agreement in level of climbing ability 3 months pre- and 3 months post-operatively (kappa=0.287, p<0.001), and a substantial agreement between 1 year post-operatively and currently for both climbing (kappa=0.730, p<0.001) and mountaineering (kappa=0.684, p<0.001). Impressively, 17 participants are climbing at more than E1 trad or 6c sport at one or more time points post operatively, which is regarded as an advanced level within the climbing community. Out of those 17 participants, 8 were climbing at this level within 3 months post-operatively. The level of climbing possible following hip arthroplasty surgery is above what is expected and perhaps desired by the operating surgeon. It is essential to take the individual patient into account when planning an operative intervention such as arthroplasty. The one year post-operative time point is highly predictive of longer term outcomes for both climbing and mountaineering.
Circular external fixators are fundamental to lower limb reconstruction, primarily in situations with a high risk of infection such as open fractures. During the Covid-19 pandemic, use of circular frames in our unit decreased, following departmental approval, due to resource management and in keeping with BOA guidelines as we opted to “consider alternative techniques for patients who require soft tissue reconstruction to avoid multiple operations”. These alternatives included the use of internal fixation (plate osteosynthesis and intramedullary nailing) as a measure to reduce the number of hospital attendances for patients and to conserve resources. This change in practice has continued in part following the pandemic with the increased use of internal fixation in cases previously deemed unsuitable for such techniques. We present our experience of this treatment strategy in the management of complex lower limb injuries, focusing on outcomes and consider the lessons learnt. Data of patients with complex lower limb injuries treated before, during and after the pandemic were collected from our in-house trauma database, theatre records and follow up clinics. The rationale for choosing other techniques over a circular frame, the type of alternative technique used, the cost of such alternatives, the need for soft tissue reconstruction, time to recovery, complications and amputation rates were compared among groups.Introduction
Materials & Methods
Variations in component positioning of total hip replacements can lead to edge loading of the liner, and potentially affect device longevity. These effects are evaluated using ISO 14242:4 edge loading test results in a dynamic system. Mediolateral translation of one of the components during testing is caused by a compressed spring, and therefore the kinematics will depend on the spring stiffness and damping coefficient, and the mass of the translating component and fixture. This study aims to describe the sensitivity of the liner plastic strain to these variables, to better understand how tests using different simulator designs might produce different amounts of liner rim deformation. A dynamic explicit deformable finite element model with 36mm Pinnacle metal-on-polyethylene bearing geometry (DePuy Synthes, Leeds, UK) was used with material properties for conventional UHMWPE. Setup was 65° clinical inclination, 4mm mismatch, 70N swing phase load, and 100N/mm spring. Fixture mass was varied from 0.5-5kg, spring damping coefficient was varied from 0-2Ns/mm. They were changed independently, and in combination. Maximum separation values were relatively insensitive to changes in the mass, damping coefficient, or both. The sensitivity of peak plastic strain, to this range of inputs, was similar to changing the swing phase load from 70N to approximately 150N – 200N. Increasing the fixture mass and/or damping coefficient increased the peak plastic strain, with values from 0.15-0.19. Liner plastic deformation was sensitive to the spring damping and fixture mass, which may explain some of the differences in fatigue and deformation results in UHMWPE liners tested on different machines or with modified fixtures. These values should be described when reporting the results of ISO14242:4 testing. Acknowledgements Funded by EPSRC grant EP/N02480X/1; CAD supplied by DePuy Synthes.
Autologous cancellous bone graft is the gold standard in large bone defect repair. However, studies using autologous bone grafting in rats are rare and donor sites as well as harvesting techniques vary. The aim of this study was to determine the feasibility of autologous cancellous bone graft harvest from 5 different anatomical sites in rats and compare their suitability as donor sites for autologous bone graft. 13 freshly euthanised rats were used to describe the surgical approaches for autologous bone graft harvest from the humerus, iliac crest, femur, tibia and tail vertebrae (n=4), determine the cancellous bone volume and microstructure of those five donor sites using µCT (n=5), and compare their cancellous bone collected qualitatively by looking at cell outgrowth and osteogenic differentiation using an ALP assay and Alizarin Red S staining (n=4). It was feasible to harvest cancellous bone graft from all 5 anatomical sites with the humerus and tail being more surgically challenging. The microstructural analysis showed a significantly lower bone volume fraction, bone mineral density, and trabecular thickness of the humerus and iliac crest compared to the femur, tibia, and tail vertebrae. The harvested volume did not differ between the donor sites. All donor sites apart from the femur yielded primary osteogenic cells confirmed by the presence of ALP and Alizarin Red S stain. Bone samples from the iliac crest showed the most consistent outgrowth of osteoprogenitor cells. The tibia and iliac crest may be the most favourable donor sites considering the surgical approach. However, due to the differences in microstructure of the cancellous bone and the consistency of outgrowth of osteoprogenitor cells, the donor sites may have different healing properties, that need further investigation in an in vivo study.
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship.
Thumb carpometacarpal joint (CMCJ) arthritis is a common and debilitating condition. The mainstay of surgical management is Trapeziectomy. Concerns about possible functional implications of collapse of the metacarpal into the arthroplasty space as well as the potential for scaphometacarpal led to the development of techniques to try and prevent this. The purpose of this study was to investigate if there were any significant differences in the long-term outcomes of patients who participated in a randomized trial of trapeziectomy alone compared with trapeziectomy with ligament reconstruction and tendon interposition (LRTI). Sixty-five patients participated in our original trial, the 1 year findings of which were published in 2007. These patients were invited for a follow-up visit at a mean of 17 years (range 15–20) postoperatively. Twenty-eight patients attended, who had 34 operations, 14 trapeziectomy alone and 20 with LRTI. Patients were asked to complete a visual analogue scale (VAS) for satisfaction with the outcome of their procedure, rated on a scale from 0 (most dissatisfied) to 100 (most satisfied). They also completed the short version of the Disabilities of the Arm, Shoulder and Hand Score (QuickDASH) at their appointment. They underwent a functional assessment with a hand therapist and had a radiograph of the thumb. There were no statistically significant differences between the two groups in terms of satisfaction with surgery or functional outcomes, with most measurements showing minimal or no differences in means between the two groups. There was no difference in the space between the metacarpal and scaphoid on radiograph. Radial abduction was the only parameter that was significantly greater in the patients with simple trapeziectomy (median 79°) compared with trapeziectomy with LRTI (median 71°) (p = 0.04). Even at 17 years there is no significant benefit of LRTI over trapeziectomy alone for thumb carpometacarpal joint osteoarthritis.
Periprosthetic joint infection (PJI) following total knee arthroplasty (TKA) is a severe complication in terms of disability, morbidity, and cost. We performed a study to investigate whether early PJI (within 90 days of primary TKA) is associated with increased mortality. Secondary aims were to compare mortality rates over time and between surgical treatment methods. Patients with suspected PJI were identified by linkage of the Swedish Knee Arthroplasty Register (SKAR) and the Swedish Prescribed Drug Register (SPDR) in 2007–2008 and 2012–2013. Medical records of patients receiving more than 4 weeks of continuous antibiotic therapy were subsequently reviewed to verify the PJI diagnosis. Information on mortality was obtained through the SKAR which is updated daily from the tax agency and patients with PJI were compared to patients without PJI.Background
Methods
To achieve expert clinical consensus in the delivery of hydrodilatation for the treatment of primary frozen shoulder to inform clinical practice and the design of an intervention for evaluation. We conducted a two-stage, electronic questionnaire-based, modified Delphi survey of shoulder experts in the UK NHS. Round one required positive, negative, or neutral ratings about hydrodilatation. In round two, each participant was reminded of their round one responses and the modal (or ‘group’) response from all participants. This allowed participants to modify their responses in round two. We proposed respectively mandating or encouraging elements of hydrodilatation with 100% and 90% positive consensus, and respectively disallowing or discouraging with 90% and 80% negative consensus. Other elements would be optional.Aims
Methods
The association between body mass index (BMI) and venous thromboembolism (VTE) is well studied, but remains unclear in the literature. We aimed to determine whether morbid obesity (BMI≥40) was associated with increased risk of VTE following total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA), compared to those of BMI<40. Between January 2016 and December 2020, our institution performed 4506 TKAs and 449 UKAs. 450 (9.1%) patients had a BMI≥40. CT pulmonary angiography (CTPA) for suspected pulmonary embolism (PE) and ultrasound scan for suspected proximal deep vein thrombosis (DVT) were recorded up to 90 days post-operatively.Abstract
Aims
Methods
Meniscal allograft transplantation (MAT) for patients with symptomatic meniscal loss has demonstrated good clinical results and survivorship. Factors that affect both functional outcome and survivorship have been reported in the literature. These are typically single-centre case series with relatively small numbers and conflicting results. Our aim was to describe an international, two-centre case series, and identify factors that affect both functional outcome and survival. We report factors that affect outcome on 526 patients undergoing MAT across two sites (one in the UK and one in Italy). Outcomes of interest were the Knee injury and Osteoarthritis Outcome Score four (KOOS4) at two years and failure rates. We performed multiple regression analysis to examine for factors affecting KOOS, and Cox proportional hazards models for survivorship.Aims
Methods
The jackaling position within rugby has not been previously described as a mechanism for proximal hamstring injuries. This prospective single surgeon study included 54 professional rugby players (mean age 26 ± 4.8 years) undergoing acute primary surgical repair of complete, proximal hamstring avulsion injuries confirmed on preoperative magnetic resonance imaging. All study patients underwent a standardised postoperative rehabilitation programme. Predefined outcomes were recorded at regular intervals. Mean follow-up time was 17 months (range, 12 months to 24 months) from date of surgery. 51 patients (94.4%) returned to their pre-injury level of sporting activity. Mean time from surgical repair to full sporting activity was 7 months (range, 4 months to 12 months). Zero patients had recurrence of the primary injury. At 1 year after surgery compared to 3 months after surgery, patients had increased mean isometric hamstring muscle strength at 0° (98.4 ± 2.8% vs 88.1% ± 5.4%, p<0.001), 15° (95.9 ± 2.9 vs 88.2 ± 8.1%, p<0.001) and 45° (92.9% ± 4.1% vs 76.8% ± 9.7%, p<0.001), higher mean lower extremity functional scores (77.0 ± 2.3 vs 64.5 ± 4.5, p<0.001), and improved Marx activity rating scores (14.3 ± 1.5 vs 10.7 ± 2.6, p<0.001). Acute surgical repair of proximal hamstring avulsion injuries caused by the contact jackaling position produces high patient satisfaction, high return to preinjury level of sporting activity, with low risk of recurrence at short-term follow-up.