Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 110 - 110
1 Jan 2016
Kitamura N Goto K Kondo E Thoyama H Yasuda K
Full Access

Introduction

Ceramic total knee arthroplasty (TKA) was introduced as a new-generation of knee prostheses in clinical practice, and are expected to reduce polyethylene wear due to its resistance to abrasion and lubrication. In 1992, we developed a cruciate retaining LFA-I total knee prosthesis (KYOCERA Medical Co., Japan), which comprises an alumina ceramic femoral component and a titanium-alloy tibial component with a polyethylene insert. The purpose of this study was to evaluate clinical results in rheumatoid patients who were treated with the alumina-ceramic LFA-I prosthesis with a minimum 15-year follow-up period.

Methods

A total of 70 primary TKAs were performed in 51 patients between 1993 and 1996 using the cemented alumina-ceramic LFA-I prosthesis. Sixteen of these patients (20 knees) had died by the time of this study, of causes unrelated to the index arthroplasty, and 11 patients (16 knees) were lost to the follow-up. The remaining 34 knees were clinically and radiographically evaluated in the present study. The average follow-up time was 16.7 years. The average age of the patients was 58.2 years at the time of the operation. The clinical assessment was conducted with the Hospital for Special Surgery Knee rating score and the Knee Society scoring system. The component alignment and bone-implant interface were evaluated according to the Knee Society Roentgenographic Evaluation System.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 5 - 5
1 Jan 2016
Goto K Kitamura N Kondo E Yokota M Wada S Thoyama H Yasuda K
Full Access

Introduction

Metals used for total knee arthroplasty (TKA) are well known for their good biocompatibility, but may be a source of a release of metal ions that can be a cause of local and systemic adverse effects, aseptic loosening, and hypersensitivity reactions. One of the major difficulties in performing TKA is the selection of implants for patients who are preoperatively diagnosed as subject to metal sensitivity. Alternative solutions in cases of hypersensitivity are implants without metal constituents or metallic implants treated with a non-sensitive surface process. The aim of this study was to evaluate clinical results in patients who had been preoperatively diagnosed with metal sensitivity and who subsequently were provided with the zirconia-ceramic LFA-III TKA, and with a minimum 5-year follow-up.

Methods

Five patients (8 knees) with metal sensitivity underwent TKA using cemented zirconia-ceramic LFA-III implants. The LFA-III implant (KYOCERA Medical Co., Japan) is composed of a zirconia ceramic femoral component and a titanium-alloy tibial component with a polyethylene insert. All patients were female andthe average age at the time of surgery was 76.1 years. The average follow-up time was 7.2 years. Clinical and radiographic assessments were conducted with the Knee Society scoring system.