We aimed to examine the characteristics of deep venous flow in
the leg in a cast and the effects of a wearable neuromuscular stimulator
(geko; FirstKind Ltd) and also to explore the participants’ tolerance
of the stimulator. This is an open-label physiological study on ten healthy volunteers.
Duplex ultrasonography of the superficial femoral vein measured
normal flow and cross-sectional area in the standing and supine
positions (with the lower limb initially horizontal and then elevated).
Flow measurements were repeated during activation of the geko stimulator
placed over the peroneal nerve. The process was repeated after the
application of a below-knee cast. Participants evaluated discomfort
using a questionnaire (verbal rating score) and a scoring index
(visual analogue scale).Objectives
Methods
We systematically reviewed all the evidence published
in the English language on proximal interphalangeal joint (PIPJ)
replacement, to determine its effectiveness on the function of the
hand and the associated post-operative complications. Original studies were selected if they reported clinical outcome
with a minimum of one year’s follow-up. Quality was assessed using
the Cowley systematic review criteria modified for finger-joint
replacements. Of 319 articles identified, only five were adequately
reported according to our quality criteria; there were no randomised
controlled trials. PIPJ replacements had a substantial effect size
on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1)
and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect
on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach
was most successful. Post-operative loosening occurred in 10% (95%
CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon
replacements. Post-operative complications occurred in 27.8% (95%
CI 20 to 37). We conclude that the effectiveness of PIPJ replacement has not
been established. Small observational case studies and short-term
follow-up, together with insufficient reporting of patient data,
functional outcomes and complications, limit the value of current
evidence. We recommend that a defined core set of patients, surgical and
outcome data for this intervention be routinely and systematically
collected within the framework of a joint registry.
We describe a patient with fractures of both bones of the forearm in whom flexible intramedullary nail fixation of the radius alone led to ulnar malunion and a symptomatic distal radio-ulnar joint subluxation. This was successfully treated by ulnar osteotomy.
It is not known whether the effect of Foot Pumps is enhanced by simultaneous use of graduated compression stockings (GCS) (by controlling calf compliance) or hindered (by restricting preload). The peak velocity in the popliteal vein was measured in twenty volunteers with duplex ultrasound at rest with the legs flat, foot-up and foot-down; it was then measured when the AV Impulse was activated. These measurements were each performed with and without graduated compression stockings. Data were analysed using Wilcoxon Rank Sum test. In each position of the leg (flat, foot-up and foot-down), the Peak venous velocity was greater if GCS were not used in comparison with the peak velocity if stockings were used. There was no significant difference in resting velocity with the foot flat, foot down or foot up without stockings or with stockings. Various studies have shown the efficacy of foot pumps in reducing the incidence of DVT in patients with joint replacements and hip fractures. They do not cause soft tissue side effects and are well tolerated. The value of GCS in orthopaedic surgery is uncertain, although in other surgical specialities they seem to be effective. Stockings, by reducing the capacitance of vessels in the foot reduce the amount of blood available for expulsion by the foot pumps. Nevertheless, our study presents physiological evidence for the hypothesis that, for optimum benefit, stockings should not be used simultaneously with Foot Pumps.
Chemical prophylaxis is known to reduce the venographic prevalence of deep-vein thrombosis (DVT) after total knee replacement (TKR), but it is uncertain whether this affects the incidence of symptoms. Further analysis depends on the basic epidemiology of thromboembolic symptoms. We therefore studied the pattern of such symptoms in a consecutive series of 1000 patients with primary TKR, with particular reference to risk factors and prophylaxis. We reviewed all the clinical records and contacted all the patients individually, noting risk factors, prophylaxis, symptomatic pulmonary embolus (PE) or DVT and its timing, death and its causes, and all complications. All the patients wore antiembolism stockings, 83% had regional anaesthesia and 33.9% had chemical prophylaxis. One patient died from PE on the day of surgery, having had no prophylaxis giving a rate of 0.1% (95% CI 0.003% to 0.56%). Symptomatic, radiologically confirmed thromboembolism (VTE) was common with a rate of 10.6% (95% CI 8.7% to 12.5%). There was a similar incidence of VTE in those with and without chemical prophylaxis (10.1% Our results show that the main risk factor for thromboembolism was TKR itself; chemical prophylaxis did not reduce the incidence of symptomatic thromboembolism but gave an increased perception of side-effects. New prophylactic methods or combinations of methods are needed, with their efficacy compared by randomised controlled studies of both the clinical and the radiological effect.