Advertisement for orthosearch.org.uk
Results 1 - 19 of 19
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1494 - 1494
1 Dec 2024
Nisar S Lamb J Johansen A West R Pandit H


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1182 - 1189
1 Oct 2024
Nisar S Lamb J Johansen A West R Pandit H

Aims

To determine if patient ethnicity among patients with a hip fracture influences the type of fracture, surgical care, and outcome.

Methods

This was an observational cohort study using a linked dataset combining data from the National Hip Fracture Database and Hospital Episode Statistics in England and Wales. Patients’ odds of dying at one year were modelled using logistic regression with adjustment for ethnicity and clinically relevant covariates.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 64 - 64
2 May 2024
Lamb J West R Relton S Wilkinson M Pandit H
Full Access

Current estimates of periprosthetic fracture risk associated with femoral implants is mostly limited to revision only estimates and does not accurately represent stem performance. The aim of this study was to estimate the risk of surgically treated post-operative periprosthetic femoral fracture (POPFF) more accurately associated with frequently used femoral implants used for total hip arthroplasty (THA).

A cohort study of patients who underwent primary THA in England between January 1, 2004, and December 31, 2020. Periprosthetic fractures were identified from prospectively collected revision records and national procedure coding records. Survival modelling was used to estimate POPFF incidence rates, adjusting for potential confounders. Subgroup analyses were performed for patients over 70 years, with non-osteoarthritic indications, and neck of femur fracture.

POPFF occurred in 0.6% (5100/809,832) of cases during a median (IQR) follow up of 6.5 (3.9 to 9.6) years. The majority of POPFF were treated with fixation after implantation of a cemented stem. Adjusted patient time incidence rates (PTIR) for POPFF varied by stem design, regardless of cement fixation. Cemented composite beam stems (CB stems) demonstrated the lowest risk of POPFF. Collared cementless stems had an equivalent or lower rate of POPFF versus the current gold standard polished taper slip cemented stem.

POPFF account for a quarter of all revisions following primary THA. Cemented CB stems are associated with the lowest POPFF risk. Stem design is strongly associated with POPFF risk, regardless of the presence of cement. Surgeons, policymakers, and patients should consider these findings when recommending femoral implants in those most at risk of POPFF.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 72 - 78
9 Feb 2023
Kingsbury SR Smith LKK Pinedo-Villanueva R Judge A West R Wright JM Stone MH Conaghan PG

Aims

To review the evidence and reach consensus on recommendations for follow-up after total hip and knee arthroplasty.

Methods

A programme of work was conducted, including: a systematic review of the clinical and cost-effectiveness literature; analysis of routine national datasets to identify pre-, peri-, and postoperative predictors of mid-to-late term revision; prospective data analyses from 560 patients to understand how patients present for revision surgery; qualitative interviews with NHS managers and orthopaedic surgeons; and health economic modelling. Finally, a consensus meeting considered all the work and agreed the final recommendations and research areas.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 124 - 134
1 Feb 2023
Jain S Farook MZ Aslam-Pervez N Amer M Martin DH Unnithan A Middleton R Dunlop DG Scott CEH West R Pandit H

Aims

The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA).

Methods

Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 59 - 67
1 Jan 2022
Kingsbury SR Smith LK Shuweihdi F West R Czoski Murray C Conaghan PG Stone MH

Aims

The aim of this study was to conduct a cross-sectional, observational cohort study of patients presenting for revision of a total hip, or total or unicompartmental knee arthroplasty, to understand current routes to revision surgery and explore differences in symptoms, healthcare use, reason for revision, and the revision surgery (surgical time, components, length of stay) between patients having regular follow-up and those without.

Methods

Data were collected from participants and medical records for the 12 months prior to revision. Patients with previous revision, metal-on-metal articulations, or hip hemiarthroplasty were excluded. Participants were retrospectively classified as ‘Planned’ or ‘Unplanned’ revision. Multilevel regression and propensity score matching were used to compare the two groups.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 10 - 10
1 Aug 2021
Jain S Lamb J Townsend O Scott C Kendrick B Middleton R Jones S Board T West R Pandit H
Full Access

Cemented total hip replacement (THR) provides excellent outcomes and is cost-effective. Polished taper-slip (PTS) stems demonstrate successful results and have overtaken traditional composite-beam (CB) stems. Recent reports indicate they are associated with a higher risk of postoperative periprosthetic femoral fracture (PFF) compared to CB stems. This study evaluates risk factors influencing fracture characteristics around PTS and CB cemented stems.

Data were collected for 584 PFF patients admitted to eight UK centres from 25/05/2006-01/03/2020. Radiographs were assessed for Unified Classification System (UCS) grade and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (PTS versus CB). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (OR) with 95% confidence intervals (CI).

Median (IQR) age was 79.1 (72.0–86.0) years, 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The commonest AO/OTA type was spiral (352, 60.3%). Metaphyseal-split fractures occurred only with PTS stems with an incidence of 10.1%. Male gender was associated with a five-fold reduction in odds of a type C fracture (OR 0.22, 95% CI 0.12 to 0.41, p<0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51, 95% CI 3.72 to 24.34, p <0.001) and wedge fracture (OR 3.72, 95% CI 1.16 to 11.95, p <0.05) compared to PTS stems.

This is the largest study investigating PFF characteristics around cemented stems. The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal-split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems had higher odds of bending type fractures (transverse and wedge) compared to PTS stems. Biomechanical testing is needed for validation and investigation of modifiable factors which may reduce the risk of unstable fracture patterns requiring complex revision surgery over internal fixation.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 17 - 17
1 Aug 2021
Nix O Al-Wizni A West R Pandit H Lamb J
Full Access

Post-operative periprosthetic fracture of the femur (POPFF) is a growing problem associated with increased mortality. Most registry derived estimates of mortality only record patients who undergo revision and cohort studies are generally limited to a single center, which makes comparison for the purposes of service improvement difficult. The aim of this study is to perform a systematic review and meta-analysis of cohort studies reporting mortality following POPFF in the last decade.

Study methodology was peer-reviewed (PROSPERO: CRD42020170819). Literature search was conducted using Medline and EMBASE. Primary exposure was the diagnosis of POPFF, and the primary outcome measure was all-cause mortality: whilst an inpatient, within 30-days, within 90-days and within one year of POPFF. Proportion of patients dying (95% CI [confidence interval]) was estimated using metaregression. Results were compared to mortality following neck of femur fracture (NOF) from international NOF registry data.

4841 patients from 35 cohort studies were included. Study quality was generally low with a majority limited to a single centre. Weighted mean follow-up was 2.3 years and the most common POPFF was UCS B. Pooled proportion dying as an inpatient was 2.4% (95% CI 1.6% to 3.4%). Pooled proportion dying within 30 days was 3.3% (95% CI 2.0% to 5.0%). Pooled proportion dying within 90 days was 4.8% (95% CI 3.6% to 6.1%). Pooled proportion dying within one year was 13.4% (95% CI 11.9% to 14.8%). Mortality following POPFF was similar to that of NOF up to 30 days, but better at one year.

3.3% of patients die following POPFF within 30 days of injury. Mortality is similar to that experienced by patients following NOF up to 30 days, but better at one year, which may represent the lower underlying risk of death in the POPFF cohort. These results may form the basis for evaluation of services treating POPFF in the future.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 466 - 475
8 Jul 2021
Jain S Lamb J Townsend O Scott CEH Kendrick B Middleton R Jones SA Board T West R Pandit H

Aims

This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty.

Methods

Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 13 - 13
1 Jul 2020
Stone M Smith L Kingsbury S Czoski-Murray C Judge A Pinedo-Villanueva R West R Wright J Smith C Arden N Conaghan P
Full Access

Follow-up of arthroplasty varies widely across the UK. The aim of this NIHR-funded study was to employ a mixed-methods approach to examine the requirements for arthroplasty follow-up and produce evidence-based and consensus-based recommendations. It has been supported by BHS, BASK, BOA, ODEP and NJR.

Four interconnected work packages have recently been completed: (1) a systematic literature review; (2a) analysis of routinely collected National Health Service data from four national data sets to understand when and which patients present for revision surgery; (2b) prospective data regarding how patients currently present for revision surgery; (3) economic modelling to simulate long-term costs and quality-adjusted life years associated with different follow-up care models and (4) a Delphi-consensus process, involving all stakeholders, to develop a policy document to guide appropriate follow-up care after primary hip and knee arthroplasty.

We will present the following Recommendations:

For ODEP10A∗ minimum implants, it is safe to disinvest in routine follow-up from 1 to 10 years post non-complex hip and knee replacement provided there is rapid access to orthopaedic review

For ODEP10A∗ minimum implants in complex cases, or non-ODEP10A∗ minimum implants, periodic follow-up post hip and knee replacement may be required from 1 to 10 years

At 10 years post hip and knee replacement, we recommend clinical, which may be virtual, and radiographic evaluation

After 10 years post hip and knee replacement, frequency of further follow-up should be based on the 10-year assessment; ongoing rapid access to orthopaedic review is still required

Overarching statements

These recommendations apply to post primary hip and knee replacement follow-up

The 10-year time point in these recommendations is based on a lack of robust evidence beyond ten years

The term complex cases refer to individual patient and surgical factors that may increase the risk for replacement failure


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 20 - 20
1 May 2019
Lamb J King S van Duren B West R Pandit H
Full Access

Background

Method of fixation in THA is a contentious issue, with proponents of either technique citing improved implant survival and outcomes. Current comparisons rely on insufficiently powered studies with short-term follow up or larger poorly controlled registry studies. Patient factors are considered a key variable contributing to the risk of implant failure. One way to overcome this confounder is to compare the survival of cementless and cemented THAs patients who have undergone bilateral THAs with cemented hip on one side and cementless hip on the other. We compared stem survival of patients who have bilateral THA with one cemented stem in one hip and a cementless stem in the contralateral hip in the National Joint Registry.

Methods

UK National Joint Registry is the largest registry of its kind in the world. This study included 2934 patients with 5868 THAs who underwent bilateral THAs s between 2003 and 2016. These patients had undergone bilateral sequential THAs within 3 years of each other: cemented THA on one side and cementless on the other, Patients had identical pre-operative American Society of Anaesthesiologists group for both THAs and same indication for surgery. Implant survival was compared using Cox regression with an endpoint of stem revision.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 30 - 30
1 May 2019
Lamb J Baetz J Messer-Hannemann P Redmond A West R Morlock M Pandit H
Full Access

Background

Post-operative periprosthetic femoral fractures (PFF) are a devastating complication associated with high mortality and are costly. Few risk factors are modifiable apart from implant choice. The design features governing risk of PFF are unknown. We estimated the 90-day risk of revision for PFF associated with design features of cementless femoral stems and to investigate the effect of a collar on early PFF risk using a biomechanical in-vitro model.

Patients, materials and methods

337 647 primary THAs from the National Joint Registry (UK) were included in a multivariable survival and regression analysis to identify the adjusted hazard of PFF revision following primary THA using cementless stems. The effect of a collar in cementless THA on early PFF was evaluated in an in-vitro model using paired fresh frozen cadaveric femora.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 19 - 19
1 May 2019
Lamb J Matharu G van Duren B Redmond A Judge A West R Pandit H
Full Access

Introduction

Intraoperative periprosthetic femoral fractures (IOPFF) lead to reduced implant survival. A deeper understanding of predictors enables surgeons to modify techniques and patient selection to reduce the risk of IOPFF. The aim of this study was to estimate predictors of IOPFF and each anatomical subtype (calcar crack, trochanteric fracture, femoral shaft fracture) during primary THA.

Methods

This retrospective cohort study included 793823 primary THAs between 2004 and 2016. Relative risks for patient, surgical and implant factors are estimated for any IOPFF fracture and for all anatomical subtypes of IOPFF.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 137 - 137
1 Jan 2013
Harvey-Kelly K Kanakaris N Obakponovwe O West R Giannoudis P
Full Access

Introduction

Pelvic fractures are indicators of severe trauma and high energy absorption. They are associated with multiple local or distant concomitant injuries, which explain their high mortality and morbidity. The aim of this study is to investigate the late sequel of traumatic-pelvic-fractures (PFX) focusing on quality-of-life and sexual-function.

Methods

From a database of prospectively documented data, patients who had suffered a PFX and had been treated operatively in our institution from January 2008–2009 were recruited. Exclusion criteria were patients less than one-year post-injury, pathological-fractures, patients < 18 or >65, and patients with co-morbidities linked to sexual dysfunction. Demographics, injury-mechanisms, fracture-patterns (Young-Burgess classification), injury-severity-score (AIS/05-ISS), urogenital injuries and clinical outcome were recorded and analysed. Health-related-quality-of-life was assessed using the (EuroQol-5D) and sexual-function using the international-index-of-erectile-function and the female-sexual-function-index. The minimum follow-up was 12 months (12–30).


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 354 - 354
1 Jul 2011
Tsiridis E Pagkalos I Polyzois I Pavlou G Charity J Tsiridis E Gie G West R
Full Access

Comparison of the safety and efficacy of Bilateral Simultaneous Total Hip Arthroplasty (BSTHA) with that of staged (SgTHA) and unilateral (UTHA) was conducted using DerSimonian–Laird heterogeneity meta-analysis. A review of the English-language literature identified 23 citations eligible for inclusion. A total of 2063 bilateral simultaneous THR patients were identified. Meta-analysis of homogenous data revealed that there were no statistically significant differences between rates of thromboembolic events (p=0.268 and p=0.365) and dislocation (p=0.877) when comparing staged or unilateral with bilateral simultaneous THR procedures. A systematic analysis of heterogenous data demonstrated that mean length of hospital stay was shorter after bilateral simultaneous THR. Blood loss was reduced after bilateral simultaneous THR in all studies except for one, and surgical time was not different between groups. This procedure was also found to be economically and functionally efficacious when performed by experienced surgeons in specialist centres.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 372 - 372
1 Jul 2011
Pavlou G Pagkalos J Polyzois I Tsiridis E West R
Full Access

Controversy still remains as to whether patella resurfacing in total knee arthroplasty (TKA) should be conducted as a matter of routine. Some authors recommend routine resurfacing of the patella and advocate this due to the reduction in post-operative anterior knee pain and the reduction in requirement for revision surgery.

A database search was conducted to identify prospective randomized controlled studies only. Eighteen prospective randomized trials were identified and found eligible for inclusion. A cumulative sample of 8006 knees were involved, 3418 undergoing resurfacing and 4588 undergoing no resurfacing. Primary outcome data extracted was incidence of secondary operations, incidence of anterior knee pain and functional outcome scores including subgroup analysis of the type of prosthesis used in each study. Der Simonian Laird metanalysis was conducted if studies were found to be homogenous where statistical significance was defined as an overall alpha error of < 0.05.

No statistically significant differences were found to exist between patients undergoing patella resurfacing as a primary total knee replacement and those who preserved the native patella. No differences could be found between specific prosthetic design when subgroup analysis was conducted.

The study does not offer evidence to suggest any advantage of resurfacing versus non-resurfacing. Furthermore, no significant discrepancy existed when comparing different types of total knee prosthesis. This may be due that all the knees analysed are designed to be patella friendly and allow conformity of articulation of both a native and patella button equally


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 177 - 177
1 May 2011
As-Sultany M Polyzois I Panteliadis P West R Tsiridis E
Full Access

Background: The recognised risk of post-operative venous thromboembolism (VTE), presenting as deep vein thrombosis (DVT) and/or pulmonary embolism (PE), after elective total hip and knee arthroplasty (THA and TKA) has always made the selection of suitable thromboprophylaxis treatment a clinical priority for orthopaedic surgeons. Over recent years there has been the emergence of new oral direct Factor Xa (FXa) inhibiting anticoagulants, which may replace the widely used low-molecular-weight heparins (LMWHs).

Methods: A systematic review of published English-language literature (completed in July 2009) and surgical type meta-analyses were conducted to compare the efficacy (risk of any DVT, PE and all-cause mortality) and safety (risk of major bleeding requiring clinical intervention) of oral direct FXa inhibiting anticoagulants with LMWHs in THA and TKA.

Results: Five eligible THA randomised-controlled trials (RCTs) with total of 9286 patients and three eligible TKA RCTs with 6917 patients were identified. The Der-Simonian-Laird random effects model was employed for each meta-analysis and heterogeneity between trials was explored statistically using the Mantel-Haenszel χ2 test. The efficacy meta-analysis of THA RCTs revealed an odds ratio (OR) 0.46 (95% confidence interval (c.i.) 0.23, 0.92), which was significantly (P = 0.03) in favour of the oral FXa inhibitors but there was sizable heterogeneity amongst trials (P = 0.0002). Although the safety meta-analysis of THA RCTs showed an increase incidence of major bleeding with the use of oral FXa inhibitors, OR 1.71 (95% c.i. 0.67, 4.39), this risk was not statistically significant (P = 0.26) with little heterogeneity between trials (P = 0.44). The efficacy meta-analysis of TKA RCTs demonstrated an efficacy OR 0.56 (95% c.i. 0.42, 0.73), in favour of the oral FXa inhibitors (P = 0.0001) with no significant heterogeneity (P = 0.21). The safety meta-analysis of TKA RCTs showed an increased occurrence of major bleeding with oral FXa inhibitors, OR 1.79 (95% c.i. 0.83, 3.87), but this was not statistically significant (P = 0.14) and heterogeneity between trials was low (P = 0.54).

Conclusions: This review demonstrated an overall better efficacy for oral FXa inhibitors compared with LMWHs in thromboprophylaxis for both THA and TKA. Although it also revealed that oral FXa inhibitors were statistically as safe as LMWHs, there was clinically higher incidence of major bleeding with their use in both THA and TKA. These safety results coupled with the fact that currently no specific antidote exists, highlights the urgent need for further research and large RCTs to prove the clinical safety of all new oral direct FXa inhibiting anticoagulants.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 531 - 531
1 Oct 2010
Tsiridis E Gamie Z Gie G Graham S Pavlou G Polyzois I Rudol G West R
Full Access

Comparison of the safety and efficacy of Bilateral Simultaneous Total Hip Arthroplasty (BSTHA) with that of staged (SgTHA) and unilateral (UTHA) was conducted using DerSimonian–Laird heterogeneity meta-analysis. Twenty three citations were eligible for inclusion. A total of 2063 BSTHA patients were identified. Meta-analysis of homogenous data revealed that there were no statistically significant differences between rates of thromboembolic events (p=0.268 and p=0.356) and dislocation (p=0.877) when comparing SgTHA or UTHA versus BSTHA procedures. Systematic analysis of heterogenous data demonstrated that mean length of stay was shorter in BSTHA as compared to SgTHA and UTHA procedure, blood loss was lower in BSTHA in all studies except one, whilst the surgical time was not different between groups. BSTHA was also found to be economically and functionally efficacious.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1005 - 1012
1 Aug 2008
Tsiridis E Pavlou G Charity J Tsiridis E Gie G West R

Comparison of the safety and efficacy of bilateral simultaneous total hip replacement (THR) and that of staged bilateral THR and unilateral THR was conducted using DerSimonian-Laird heterogeneity meta-analysis. A review of the English-language literature identified 23 citations eligible for inclusion. A total of 2063 bilateral simultaneous THR patients were identified. Meta-analysis of homogeneous data revealed no statistically significant differences in the rates of thromboembolic events (p = 0.268 and p = 0.365) and dislocation (p = 0.877) when comparing staged or unilateral with bilateral simultaneous THR procedures. A systematic analysis of heterogeneous data demonstrated that the mean length of hospital stay was shorter after bilateral simultaneous THR. Higher blood transfusion requirements were expected following bilateral simultaneous THR than staged or unilateral THR, and surgical time was not different between groups. This procedure was also found to be economically and functionally efficacious when performed by experienced surgeons in specialist centres.