Advertisement for orthosearch.org.uk
Results 1 - 20 of 38
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 31 - 31
7 Aug 2024
Williams J Meakin J Whitehead N Mills A Williams D Ward M Kelly E Shillabeer D Javadi A Holsgrove T Holt C
Full Access

Background

Our current research aims to develop technologies to predict spinal loads in vivo using a combination of imaging and modelling methods. To ensure the project's success and inform future applications of the technology, we sought to understand the opinions and perspectives of patients and the public.

Methods

A 90-minute public and patient involvement event was developed in collaboration with Exeter Science Centre and held on World Spine Day 2023. The event involved a brief introduction to the project goals followed by an interactive questionnaire to gauge the participants’ background knowledge and interest. The participants then discussed five topics: communication, future directions of the research, concerns about the research protocol, concerns about data, and interest in the project team and research process. A final questionnaire was used to determine their thoughts about the event.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 50 - 50
17 Nov 2023
Williams D Ward M Kelly E Shillabeer D Williams J Javadi A Holsgrove T Meakin J Holt C
Full Access

Abstract

Objectives

Spinal disorders such as back pain incur a substantial societal and economic burden. Unfortunately, there is lack of understanding and treatment of these disorders are further impeded by the inability to assess spinal forces in vivo. The aim of this project is to address this challenge by developing and testing a novel image-driven approach that will assess the forces in an individual's spine in vivo by incorporating information acquired from multimodal imaging (magnetic resonance imaging (MRI) and biplane X-rays) in a subject-specific model.

Methods

Magnetic resonance and biplane X-ray imaging are used to capture information about the anatomy, tissues, and motion of an individual's spine as they perform a range of everyday activities. This information is then utilised in a subject-specific computational model based on the finite element method to predict the forces in their spine. The project is also utilising novel machine learning algorithms and in vitro, six-axis mechanical testing on human, porcine and bovine samples to develop and test the modelling methods rigorously.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 1 - 1
1 Feb 2016
Williams J Sandhu F Betz R George K
Full Access

Introduction

Pedicle screw fixation commonly uses a manual probe technique for preparation and insertion of the screw. However, the accuracy of obtaining a centrally located path using the probe is often dependent on the experience of the surgeon and may lead to increased complications. Fluoroscopy and navigation assistance improves accuracy but may expose the patient and surgeon to excessive radiation. DSG measures electrical conductivity at the tip and provides the surgeon with real-time audio and visual feedback based on differences in tissue density between cortical and cancellous bone and soft tissue. The authors investigated the effectiveness of DSG for training residents on safe placement of pedicle screws.

Methods

15 male cadaveric thoracolumbar spine specimens were fresh-frozen at the time of expiration. Residents were assigned 3 specimens each and randomised by pedicle side and order of technique for pedicle screw placement (free-hand versus DSG). Fluoroscopy and other navigation assistance were not used for pedicle preparation. All specimens were imaged using CT following insertion of all pedicle screws. The accuracy was assessed by a senior radiologist and graded as within (≤ 2mm breach) or outside (> 2mm breach) the pedicle.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 127 - 127
1 Jan 2016
Woodard E Williams J Mihalko W
Full Access

Introduction

When performing total knee arthroplasty (TKA), surgeons often utilize a posterior-stabilized (PS) design which compensates for the loss of the posterior cruciate ligament (PCL). These designs attempt to replicate normal knee kinematics and loading using a cam and post to provide posterior restraint of the tibia during flexion. However, these designs may not be able to compensate for the increase in flexion space or the inherent loss of coronal stability after PCL release compared to a cruciate retaining (CR) design. This study aimed to compare stability of PS and CR TKA designs by assessing laxity in three planes.

Methods

The specimens utilized in this study were lower extremities from fresh cadavers of donors who had previously undergone a total knee replacement (Medical Education and Research Institute (Memphis, TN) and Restore Life USA (Johnson City, TN)). IRB approval was obtained prior to performing the study. Twenty-three knee specimens (8 left, 15 right) were retrieved and all skin, subcutaneous tissue and muscle was removed. The femur and tibia were cut transversely 180 mm superior and inferior to the knee joint line, respectively, and specimens were mounted in a custom knee testing machine. Specimens were tested with the knee joint at full extension and at 30, 60, and 90 degrees of flexion. Laxity was assessed at 1.5 Nm of internal and external torque and 10 Nm varus and valgus torque, as well as a 35 N anterior and posterior force. Laxity was expressed as degrees of tibial displacement in the coronal plane under a varus/valgus torque and degrees of displacement in the transverse plane under an internal/external torque, as well as mm of anterior or posterior displacement. TKA components were retrieved to determine PS or CR design and grouped accordingly.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 128 - 128
1 Jan 2016
Sanford B Williams J Huffman K Zucker-Levin A Mihalko W
Full Access

Introduction

The sit-to-stand (STS) movement is a physically demanding activity of daily living and is performed more than 50 times per day in healthy adults. Several studies have shown that the normal ‘screw-home’ mechanism is altered after total knee arthroplasty (TKA). However, these studies have been criticized due to their limitations of the movement being non-weight-bearing or atypical daily activity (lunge maneuver). We analyzed TKA subjects during a STS activity to determine if the internal-external rotation of their TKA knees differed from the knees of control subjects.

Materials and Methods

Six TKA subjects (3 M, 3 F) participated following institutional review board approval and informed consent. One subject had bilateral knee replacement. Surgery was performed by the same surgeon using the same type of implant (6 posterior-stabilized, 1 cruciate-retaining). The control group included eight healthy subjects (6 M, 2 F).

Retro-reflective markers were placed over bony landmarks of the torso, pelvis, and lower extremities, and arrays of four markers were attached to the thighs and shanks using elastic wrap. A digitizing pointer was used to create virtual markers at the anterior superior iliac spines. A nine camera video-based opto-electronic system (Qualisys) was used for 3D motion capture. Subjects were barefoot and seated on a 46 cm armless bench with one foot on each force plate (AMTI). Subjects rose from their seated position, paused, and returned to the seated position at a self-selected pace repeatedly for 30 seconds. Subjects did not use their arms to push off the bench. Only the STS portion of the task was analyzed. The start of the STS cycle was defined when the C7 marker began to move forward in the sagittal plane and ended at the point of maximum knee extension. Only the right leg of the control subjects was used for analysis.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 129 - 129
1 Jan 2016
Sanford B Williams J Zucker-Levin A Mihalko W
Full Access

Introduction

In a previous study of subjects with no history of lower extremity injury or disease we found a linear relationship between body weight and peak hip, knee, and ankle joint forces during the stance phase of gait. To investigate the effect of total knee arthroplasty (TKA) on forces in the operated joints as well as the other joints of the lower extremities, we tested TKA subjects during gait and performed inverse dynamics analyses of the results.

Materials and Methods

TKA subjects (3 M, 1 F; 58 ± 5 years; body mass index range (BMI): 26–36 kg/m2) participated in this investigation following institutional review board approval and informed consent. One subject had bilateral knee replacement. Each patient received the same implant design (4 PS, 1 CR). Data from previously tested control subjects (8 M, 4 F; 26 ± 4 years; BMI: 20–36 kg/m2) were used for comparison.

Retro-reflective markers were placed over bony landmarks of each subject. A nine-camera video-based opto-electronic system was used for 3D motion capture as subjects walked barefoot at a self-selected speed on a 10 meter walkway instrumented with three force plates. Data were imported into a 12-body segment multibody dynamics model (AnyBody Technology) to calculate joint forces. Each leg contained 56 muscles whose mechanical effect was modeled by 159 simple muscle slips, each consisting of a contractile element. The models were scaled to match each subject's anthropometry and BMI. For the control subjects, only one limb was used in determining the relationship between body mass and peak joint force at the hip, knee, and ankle. For the TKA subjects, the peak joint forces were calculated for both the TKA limb and the contralateral limb.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 37 - 37
1 Oct 2015
Gakhar H Bommireddy R Calthorpe D Klezl Z Williams J
Full Access

Background

Loss of muscle mass (sarcopenia) and function in ageing are associated with reduced functional ability, quality of life and reduced life expectancy. In cancer patients, age related muscle loss may be exacerbated by cachexia and poor nutritional intake. Individuals with widespread disseminated disease are most prone to increasing functional decline, increased morbidity and accelerated death. However subjective assessments of physical performance have been shown to be poor indicators of life expectancy in these patients.

Aims

To develop an objective measure to aid calculation of life expectancy in cancer by investigating the association between objectively measured lean muscle mass and longevity, in 41 patients with known spinal metastases from all cause primaries.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 13 - 13
1 Apr 2014
Shields D Marsh M Aldridge S Williams J
Full Access

The management of displaced forearm diaphyseal fractures in adults is predominantly operative. Anatomical reduction is necessary to infer optimal motion and strength. The authors have observed an intraoperative technique where passive pronosupination is examined to assess quality of reduction as a surrogate marker for active movement.

We aimed to assess the value of this technique, but intentionally malreducing a simulated diaphyseal fracture of a radius in a cadaveric model, and measuring the effect on pronosupination.

A single cadaveric arm was prepared and pronation/supination was examined according to American Academy of Orthopaedic Surgeons guidance. A Henry approach was then performed and a transverse osteotomy achieved in the radial diaphysis. A volar locking plate was used to hold the radius in progressive amounts of translation and rotation, with pronosupaintion measured with a goniometer.

The radius could be grossly malreduced with no effect on pronation and supination until the extremes of deformity. The forearm showed more tolerance with rotational malreduction than translation. Passive pronation was more sensitive for malreduction than supination.

The use of passive pronosupination to assess quality of reduction is misleading.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 590 - 590
1 Dec 2013
Woodard E Mihalko W Crockarell J Williams J
Full Access

Introduction:

Repair of the arthrotomy is a performed at the end of every total knee arthroplasty (TKA). After the arthrotomy is performed, most surgeons attempt to close the arthrotomy with the medial and lateral edges anatomically approximated. If no landmarks are made prior to performing the arthrotomy however, there is a risk that anatomic approximation may not be obtained. This study looked into the biomechanical changes in stiffness of the knee before and after a medial parapatellar approach repaired with an anatomic, and shifted capsular repair with the medial side of the arthrotomy shifted up or down when repaired to determine if capsular closure may have an effect on the stiffness of the joint.

Methods:

Fourteen cadaveric TKA specimens were retrieved through the Medical Education and Research Institute (Memphis TN). For each specimen tested, the skin and muscle tissue was removed, and the femur and tibia were cut transversely 180 mm from the joint center. Specimens were fixed in extension in a custom knee testing platform (Little Rock AR) and subjected to a 10 Nm varus and valgus torque and a 1.5 Nm internal and external rotational torque. The angle at which these moments occurred was recorded, and each test was repeated for 0, 30, 60, and 90 degrees of flexion. After tests were performed on retrieved TKA specimens, a fellowship trained orthopedic surgeon vented the knee capsule by making an incision with a number 10 scalpel blade in a horizontal nature to provide a landmark for anatomic reapproximation. Tests were repeated as before, after which the surgeon performed a standard arthrotomy and repaired it using #0 suture and a neutral alignment. Sutures were cut and the repair was repeated using upward 5 mm shift and downward 5 mm shift of the medial side of the arthrotomy during the repair. All tests were repeated after each repair technique. Any increase or decrease in laxity after capsule repair was referenced to the TKA laxity tested prior to an arthrotomy being performed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 589 - 589
1 Dec 2013
Woodard E Mihalko W Williams J Crockarell J
Full Access

Introduction:

Soft tissue balancing is a part of every total knee arthroplasty (TKA) surgery. Traditionally, balancing the varus knee has been approached by releasing portions of the medial soft tissue sleeve in a sub-periosteal nature off of the proximal tibia, but this may lead to undue laxity or residual pain about the area the release was performed. More recently, “pie crusting” of the medial soft tissue sleeve has been used to balance the varus knee without compromising the structural integrity of the ligament. This technique may provide advantages over a sub-periosteal release by targeting only medial tight bands that can be palpated with the capsule distracted in 90 degrees of flexion and full extension. This study aims to biomechanically validate the pie crusting technique of the medial soft tissue sleeve and compare the results to those of standard medial releases that have been previously reported.

Methods

Six cadaveric TKA specimens were retrieved through the Medical Education and Research Institute (Memphis TN). For each specimen tested, the skin and muscle tissue was removed, and the femur and tibia were cut transversely 180 mm from the joint center. Specimens were fixed in extension in a custom knee testing platform (Little Rock AR) and subjected to a 10 Nm varus and valgus torque. The angle at which these moments occurred was recorded, and each test was repeated for 0, 30, 60, and 90 degrees of flexion. After tests were performed on TKA specimens, a fellowship trained orthopedic surgeon performed “pie crusting,” making alternating stab patterns with a number 11 scalpel blade along the anterior half of the superficial medial collateral ligament (SMCL) or posterior half of the SMCL including the posterior oblique ligament (POL). Three specimens had the anterior capsule pie crusted first and three had the posterior pie crusting performed first, followed by complete pie crusting. After two stages of pie crusting, the medial soft tissue sleeve was released off of the proximal tibia in a sub-periosteal fashion for comparison. Laxity was defined as the angles at which valgus torque equaled 10 Nm. Any increase or decrease in laxity was referenced to the normal TKA laxity.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 206 - 206
1 Dec 2013
Woodard E Mihalko W Williams J
Full Access

Soft tissue balancing during Total Knee Arthroplasty (TKA) is a step every surgeon takes during surgery. Coronal and transverse plane mechanical alignment is another parameter that surgeons address during surgery in an attempt to decrease wear and increase longevity. To date, a correlation between laxity, component wear patterns, and alignment of the tibial and femoral implant components has not been established. Theoretically, suboptimal alignment and poor soft tissue balancing should increase polyethylene wear and decrease implant survivorship, contributing to implant loosening and costly revision surgeries. This study utilizes a retrieval program of functioning TKAs obtained at the time of necropsy. By utilizing CT scans, mechanical laxity testing, and polyethylene damage scores, we aimed to determine if any correlation between proper alignment and ligament balancing to polyethylene damage scores exists.

Methods:

Computed Tomography (CT) scans were performed on 17 cadaveric knees containing TKAs obtained from the Medical Education and Research Institute (Memphis TN) using a GE Brightspeed scanning system with a 1.25 mm slice thickness. Transverse slices from these scans were used to calculate the femoral and tibial component rotation for each specimen. Component rotation was determined by utilizing previously published methods (Berger et al), and component mismatch was defined as the difference in rotation angles of the femoral and tibial components. After removal of skin, subcutaneous and muscle tissue, the tibia and femur of each leg was cut transversely, and the specimens were mounted in a custom knee testing machine (Little Rock, AR). Specimens were subjected to a 10 Nm varus and valgus torque and a 1.5 Nm internal and external rotation torque. Data was continuously recorded, and the angle or displacement at each torque or force was noted. Each test was performed at full extension and 30, 60, and 90 degrees of flexion. TKA components were then removed from the cadaveric knees, cleaned of PMMA, and visually inspected for wear using a grading system with 10 wear areas on the articulating surface of the polyethylene tibial insert (Hood et al). Scores were assigned based on severity of 7 different degradation characteristics, and were separated based on medial or lateral compartment. The maximum possible total score was 210 for each knee.

Results:

The average length of TKA implantation was 10 years. The coronal angle at +10 Nm (varus) moment ranged from 5 to 12 degrees, while the angle under a −10 Nm (valgus) moment ranged from 7 to 11 degrees across 10 specimens. The average component rotational mismatch was 20.5 degrees. The average overall medial wear score was 8.8, while the lateral average was 9.6. Wear scores showed a higher correlation to laxity in the medial compartment than the lateral side (Figures 1 and 2).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_26 | Pages 20 - 20
1 Jun 2013
Sellers E Fearon P Ripley C Vincent A Barnard S Williams J
Full Access

High energy chest trauma resulting in flail chest injury is associated with increased rates of patient morbidity. Operative fixation of acute rib fractures is thought to reduce morbidity by reducing pain and improving chest mechanics enabling earlier ventilator weaning.

A variety of operative techniques have been described and we report on our unit's experience of acute rib fracture fixation. Over 18 months, 10 patients have undergone acute rib fracture fixation. Outcome measures included; patient demographics, time ventilated pre-operatively, time ventilated post-operatively and time spent on ITU/HDU post operatively.

The mean time from presentation to surgery was 5 days (range 2–12 days). The mean time ventilated post operatively was 2 days (range 1–4 days) and the mean number of days spent on ITU/HDU post-operatively was 6 days (range 2–11 days).

Our results appear positive in terms of time spent ventilated post-operatively but no conclusion can be drawn as we have no comparable non-operative group. We have however shown, that rib fracture fixation can be carried out successfully and safely in a trauma centre. Further evidence on rib fracture fixation is required from a large, multi-centre randomised controlled trial.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 142 - 142
1 Sep 2012
Patel A Williams J Travers C Stulberg SD
Full Access

Introduction

It is thought that socioeconomic status and cultural upbringing influence the patient based outcomes of total joint arthroplasty. Previous studies have shown that patients in a lower socioeconomic class had surgery at an earlier age, increased comorbidities, increased severity of symptoms at presentation, and less satisfaction with the outcome. The purpose of this study was to compare the 1) reasons for undergoing total joint replacement and 2) satisfaction with the outcome among patients in different cultures and socioeconomic categories. We hypothesized that the overall reasons for undergoing surgery would be similar among all groups.

Method

Patients undergoing total hip or knee arthroplasty were divided into groups based on their country of residence and socioeconomic status. The patients were asked to rank their reasons for undergoing surgery preoperatively from 1 to 4 according to importance. They were also asked to state how much relief of pain or improvement in function they expected to obtain. They were then asked to complete a questionnaire assessing their satisfaction with surgery 6 months post-operatively. These results were then compared across the three groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 85 - 85
1 May 2012
Abbas G Chuter G Williams J
Full Access

Introduction

Primary Total Elbow Replacement (TER) is gaining popularity as a primary treatment option for osteoporotic fractures of the elbow, particularly in patients with low demand. The aim of this study was to assess the clinical and functional efficacy of TER as a primary treatment for comminuted distal humerus fractures in the elderly.

Methods

We retrospectively reviewed twenty-three patients (22 females and 1 male) who were treated with primary total elbow replacement for complex, intra-articular fractures of the distal humerus in the elderly between March 2000 and January 2010. The average age of the patients was seventy-five years (ranging from 66 to 94 years). Postoperative elbow function was assessed using the Mayo Elbow Performance Score. The radiological assessment was performed using antero-posterior and lateral radiographs done at follow-up appointments.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 7 - 7
1 May 2012
Dahill M Stevenson A Hughes A Williams J
Full Access

Magnetic resonance imaging (MRI) scans are widely used in the assessment of knees, often prior to arthroscopic procedures. The reporting of chondral damage on MRI scans can be variable. The correlation between MRI reports of chondral damage and that found at arthroscopy is often inconsistent. The aim of this study was to identify how well MRI reports correlated with the extent of chondral damage found at arthroscopy. A retrospective case-note review of a single-surgeon series of 175 arthroscopic procedures was performed. 83 patients were included in the study. The remainder were excluded if an MRI scan had not been performed, or had been performed more than 3 months prior to surgery. The condition of the articular cartilage demonstrated by MRI was compared to that found at arthroscopy. Data was analysed for presence and extent of chondral damage. Comparison between MRI and arthroscopy findings showed high Specificity (90%) and Negative Predictive Values (89%) for chondral damage, but low Sensitivity (46%). Cohen's kappa values < 0.2 revealed very poor correlation for the extent of damage. This study demonstrates that MRI is good at describing whether articular damage is present but does not reliably describe the extent of the damage.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 90 - 90
1 Feb 2012
Cloke J Watson H Purdy S Steen I Williams J
Full Access

Shoulder pain represents a significant burden of disease in the general population, yet there is a lack of evidence about the effectiveness of routinely used interventions. Current management of ‘painful arc’ of the shoulder in Primary Care is not evidence-based.

Over a six-month period patients with ‘painful arc’ of less than six months duration were recruited via their GPs. Eligible patients were consented to enter the trial and were then randomised, by sealed envelopes, to one of four arms of the study: control (normal analgesia and/or non-steroidal anti-inflammatory medication), a specified and repeatable Exercise and Manual Therapy Package (EMTP), a course of up to three subacromial steroid injections or both the EMTP and the steroid injections. The interventions and clinic follow-ups were over an 18-week period. A final postal questionnaire was sent out at one year. The progress of the patients was monitored using the Oxford Shoulder Score (OSS) and the SF36 general health questionnaire.

Seventy-nine GPs referred 186 patients, of whom 112 were randomised (Control=27, EMTP=29, Injections=28, Both=28). 64 patients were female and 48 male. The mean age was 54.5 years (range 23-88 years). Ninety patients completed the trial (Control=20, EMTP=22, Injections=26, Both=22). Sixty-two returned the follow-up questionnaire.

By paired sample t-tests, no significant differences were found between the OSS scores or SF-36 (physical health total) at the beginning and end of the intervention period, or at one year, in any group. There were no differences in changes in scores between groups. Two patients in the injection group went on to surgery, along with one each in the control and EMTP groups.

We have found no significant differences in outcome between steroid injections, a physiotherapy package, both treatments, or symptomatic treatment in our group of patients presenting with symptoms of painful arc of the shoulder.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 22 - 22
1 Jan 2011
Malek I Loughney K Ghosh S Williams J Francis R
Full Access

We aimed to audit the results of one stop fragility fracture risk assessment service at fracture clinic for non-hip fractures in 50–75 years old patients at Newcastle General Hospital. Currently, fewer than 30% of patients with fragility fractures benefit from secondary prevention in the form of comprehensive risk assessment and bone protection because of multifactorial reasons. We have a fragility fracture risk assessment service staffed by an Osteoporosis Specialist Nurse equipped with a DEXA scanner located at the fracture clinic itself.

We carried out a retrospective audit of 349 patients of 50–75 years with suspected non-hip fractures referred from A& E Department from October 2006 to September 2007. Patients over 75 years were excluded because as per NICE guidelines, they should receive bone protection without need of a DEXA scan.

Out of these 349 patients with suspected fractures, 171 had fragility fractures. Median age was 64 years. 69 patients had humerus fracture, 65 had forearm fracture and 23 patients had ankle fracture and 14 had metatarsal fractures. Fracture risk assessment was carried out in 120 (70%) patients. Thirty Seven (31%) patients had osteoporosis and bone protection was recommended to GP. 38 (32%) had osteopenia and lifestyle advice was provided. 45 (37%) had normal axial bone densitometry. 90% patients had DEXA scan at the same time of fracture clinic appointment. Patients with male gender, undisplaced fracture and fewer fracture clinic appointments were more likely to miss fracture risk assessment.

Our experience suggests that locating fragility fracture risk assessment service co-ordinated by an Osteoporosis Specialist Nurse at fracture clinic is an efficient way of providing secondary prevention for patients with fragility fractures. This can improve team communication, eliminate delay and improve patient compliance because of ‘One Stop Shop’ service at the time of fracture clinic appointment.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 50 - 50
1 Jan 2011
Punwar S Sidwell I Williams J
Full Access

In February 2007 an Electronic Emergency Board was introduced into the Orthopaedic Department at Musgrove Park Hospital. The aims of this system were to replace the often disorganized handwritten trauma white-board and improve multidisciplinary communication.

The electronic board can be accessed from any computer terminal in the hospital and a large plasma screen is kept permanently on display in the orthopaedic theatre corridor. Emergency admissions are added by the on-call registrar before the morning trauma meeting and during the day the board is managed by our Trauma Coordinator.

We performed an informal survey of orthopaedic trauma departments in the South West region to ascertain current practices for organizing the trauma workload.

In summary we have introduced an electronic system for the organising and recording of all our trauma cases. We have found this system extremely beneficial to the smooth running of the orthopaedic trauma service.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 504 - 504
1 Oct 2010
Honl M Plytwana T Williams J Wimmer M
Full Access

Introduction: Autologous osteochondral transfer is an option for the treatment of articular defects. However, there are concerns about graft integration and the nature of the tissue forming the cartilage-cartilage interface. Chondrocyte viability at graft and recipient edges is stated to be an important determinant of the success of repair.

As a tool, water jet (WJ) provides a cold cutting process. The cut is performed using water under high pressure (potential energy) by transforming it into water with high velocity (kinetic energy) using a nozzle.

This study evaluates the feasibility of performing selective cutting on the cortical bone and articular cartilage tissue by the use of plain water jetting.

Materials and Methods: Fresh full thickness cartilage explants were obtained from the stifle joints of 5 young calves (6–8 months old). Full thickness cartilage explants were removed from the femoral condyles using a scalpel. A specially designed water jet system was used for the study. The intensifier pump allowed pressure variations between 100–700 bars. The nozzle (Ø=0.2mm) was mounted on a gantry with two degrees of freedom. The cutting experiments were performed in displacement control mode, with cartilage held stationary and the nozzle moving at a traverse speed of 1mm/s. To calculate the energy typically required for consistent material removal, 40 cartilage samples were cut at various pressure levels using the water jet. Depths of the cut were measured by a Vernier caliper.

Multi- and one-way analyses of variance were computed with cutting depth as dependent variable.

In the second part of the study osteochondral cylinders were obtained from the femoral condyles using:

8 mm diameter Arthrex OATS punch,

8 mm diameter diamond coated drill punch and

the water jet cutting device.

Plugs were then assessed for cell viability along the cut periphery by performing live-dead cell staining and viewing under the confocal laser scanning microscope.

Results: There was a significant correlation between pressure and kerf depth (p< 0.001). At a relatively high transverse speed of 1mm/s cartilage was cut smoothly and easily. The typical material removal energy for bovine cartilage is 7,38.109 J/m3. Using Equation 1, the resultant kerf depths of multiple jet parameter can be calculated easily.

The margin of superficial zone cell death at the curved edge was significantly greater in the OATS punch group (390±18μm) and in the diamond drill group (440±18μm), when compared to the WJ group (10±4 μm).

Discussion: The dead at the cutting edge was greatly for WJ cut samples, making it a promising technology for cartilage repair. The results of the present study suggest that water jet cutting has the potential to be developed as an alternative means to prepare the cartilage for patients undergoing cartilage transplantation.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 183 - 183
1 Mar 2010
Ackland D Yap V Hardige A Ackland M Williams J de Steiger R
Full Access

There are several different ways of preparing the femoral canal prior to cementing a hip prosthesis. This study investigated the mechanical strength of the cement-bone interface of four different types of preparation determined by the maximum tensile force required to separate a cemented prosthesis from its cancellous bone origin.

Forty-eight fresh-frozen ox femora were prepared for hip arthroplasty, In a four-way comparison, groups of eleven femora were prepared by irrigation using

syringe injected normal saline;

hydrogen-peroxide soaked gauze;

pulse-lavage brushing; and

pulse-lavage brushing and hydrogen-peroxide soaked gauze combination.

Specimens were secured to a Material-test System (MTS), and the femoral implant pulled from the femur uni-axially at a rate of 5mm/min. The ‘pull-out strength’ was defined as the maximum tension recorded by the MTS during separation. Cement interdigitation was also inspected for each technique by microscopy of eight bone-implant transverse sections taken from prepared specimens.

Following an analysis of variance and pair-wise Fisher comparison, the average pull-out strength of the cemented prosthesis was significantly higher (P< 0.001) using pulse-lavage brushing (mean 8049.2 N), and pulse-lavage brushing in combination with hydrogen-peroxide soaked gauze (mean 8489.1 N), than with normal saline irrigation (mean 947.1 N) or hydrogen-peroxide soaked gauze preparation (mean 1832.6 N). Prosthesis pull-out strength following pulse-lavage brushing in combination with hydrogen-peroxide soaked gauze was not significantly different (P> 0.05) than preparing with pulse-lavage brushing alone. Low and high power microscopy of specimen transverse sections revealed the greatest levels of cement penetration in specimens prepared using pulse-lavage brushing.

This study demonstrated that one of the most effective preparations of the femoral canal for optimal mechanical fixation between cement and cancellous bone is pulse- lavage brushing. The use of hydrogen-peroxide soaked gauze in femoral canal preparation, either alone or in combination with pulse-lavage brushing, may not significantly improve prosthesis fixation.