Modular hip designs offer potential for customising the implant to the patient. However, the more features a device has to offer, the potential for misuse increases. This paper will review one modular stem and the pearls learned over the years to make this a simple and reproducible surgical technique. Over a 1,000 primary THA have been performed since the development of the proximal modular stem in 2000. The two senior surgeons developed the stem design and surgical techniques used and described here. Two additional surgeon co-authors have used the device as described confirming the design and techniques to be simple, reliable and reproducible. Often the tricks of the trade go unpublished and each new surgeon is left to his own learning curve with new devices. As with any surgical instrumentation there are significant little techniques that often make surgery more reproducible and enjoyable. Surgical technique should be simple and reproducible. We have found that even simple procedures—such as head resection—can, and do, impact the surgical process and can affect surgical outcome. Canal reaming, flute engagement, conical reaming, broaching, trochanter clearance, proper use of modular trials and implant assembly all play critical roles to a successful outcome. We have found, and previously reported, that the use of this proximal modular stem design has reduced our leg length inequalities +/− 5 mm and has all but eliminated dislocations and aseptic loosening. There were some mechanical failure problems (previously reported) on the first generation modular junction design that was identified and corrected (never exported outside the U.S.). There have been no reported failures since introduction of the improved modular junction six years ago. Independent selection of femoral offset and vertical height is possible and we feel that restoration of joint mechanics is more reproducible with proximal modular devices as compared to monoblock stems. It is the responsibility of surgeons to communicate their understanding and experience with newer devices and not rely on industry to fill this function.
Hip simulator studies on MOM bearings have historically involved ‘custom’ cetabular cups. I.e. having neither beaded layers nor biological coatings. The aim of this study was to investigate wear using such MOM bearings and evaluate the potential wear and evaluate the potential for error in the gravimetric assessment. Six x 38 mm HC Co-Cr bearings were supplied (Global and IO International Orthopaedics). The cups were received in ‘off-the-shelf’ condition with a cast Co-Cr beaded/HA-coated backing. To remove the HA-coating, the cups were pre-soaked in lemon juice for 4 days (articular surfaces shielded). Custom plastic fixtures were machined to fit the beaded contours of the cups. Test duration was 5Mc inorbital hip simulator (Shore-Western). MOM wear was estimated from serum ion contamination. Serum samples were digested and assessed using ICP/MS (Weck Labs Inc, CA). The majority of the HA-coating was removed from the cups after four days of soaking inlemon juice after 21 days of soaking all cup weights appeared atable (within 1 mg). Reflected-light microscopy (RLM) showed no descernible signs of HA and the total weight loss due to HA remval averaged∼400mg. During hip simulator there was no visual evidence of lost or broken beads, 3rd body abrasion etc (Sa<30nm). Both gravimetric and metal ion analysis showed consistent wear trends for all MOM cups. The MOM with the highest wear (predicted by ion analysis) demonstrated 1.2 mm (3)/Mc)OWR) at 5Mc. In comparsion, gravimetric analysis predicted an OWR of 1.3 mm (3)Mc for the same MOM, a difference of only 8%. Soaking beaded-HA cups in lemon juice and BCS proved effective in removing the coating. The beaded cups remained stable in weight during the wear study and caused little discrepancy in gravimetric analysis (8%). The method described did not lead to breaking of beads, elevated 3rd-body abrasion, cup damage or distorted wear scars.
To-date neck-sparing stems have been disappointing in their ability to maintain the calcar. A new approach was undertaken to improve load transfer and to create a tissue-sparing stem that would be simple in design, reproducible in technique and provide for fine-tuning joint mechanics while maintaining compressive loads to the calcar.
A modular neck provides for fine-tuning joint mechanics.
Bone and Tissue sparring Restoration of joint mechanics Minimal blood loss Potential reduction in rehabilitation Ease of revision Simple surgical technique Options for bearing surface Selection of femoral head diameter Standard surgical approach to the hip We are encouraged and believe there are advantages in the concept of neck sparing stems. Clinical/surgical evaluation is now underway and will be reported on in the future.
Cemented total knee arthroplasty has excellent long term survivorship however deficiencies of the cement mantle can compromise results. Minimising mantle deficiencies and increasing mantle size, may improve implant fixation and survivorship. The aim of this study was to evaluate the effectiveness of pressurized carbon dioxide lavage in an attempt to increase cement penetration into bone. Two consecutive series of TKAs where performed by the senior surgeon. During the first series standard cementing techniques where utilised prior to prosthesis implantation. The bone surfaces were cleaned with pulsatile lavage and then dried prior to cementation (n=69). During the second series a jet of high pressure carbon dioxide was also delivered to the bone surfaces via a hand held device (CarboJet, Kinamed Inc, Global Orthopaedic Technology)(n=50). A single investigator reviewed standardised post operative radiographs with respect to, depth of cement mantle around the prosthesis, and the presence of mantle defects. The cement mantle around the tibial and femoral prosthesis was divided into multiple zones, similar to that applied by the Knee Society. The depth of cement penetration was then measured for each zone in 0.5 mm increments using a 115% rule. Depths were averaged and then analysed using students’ T test. Cement penetration was greater with the use of pressurized carbon dioxide lavage. The greatest difference was seen in zones 1 and 4 beneath the Tibial prosthesis. A Significant difference was noted between groups. The size of the cement mantle can be increased with the use of pressurized carbon dioxide lavage. It is postulated that the bone interstices are cleared of fat and fluid more effectively than with fluid lavage alone. This may lead to an improved outcome for cemented total knee arthroplasty.
The Harris Hip Scores and Pain Scores show a significant improvement comparing preoperative with postoperative results in this series. One patient required revision of the femoral neck component for recurrent dislocation and three patients have significant rotational thigh pain due to varus implantation of the stem (the pilot has since been shortened and the diameter reduced by 1mm).
Clinical assessment, X-rays and Dexa analysis indicate satisfactory results with good incorporation of the prosthesis by the bone.
13 hips (11.8%) had mid-thigh pain, most of them mild. One hip (0.9%) showed clinical and radiographic signs of early loosening and was revised.