Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 44 - 44
1 May 2021
Zenios M Oyadiji T Zamini-Farahani A
Full Access

Introduction

In my paediatric Orthopaedic practice I use Kirchner wires for the fixation of the TSF on bone. I noted a significant percentage of wire loosening during the post-operative period. The aim of this project was to establish the effectiveness of the wire clamping mechanism and find ways to reduce the incidence of wire loosening when using the TSF.

Materials and Methods

In the first instance wire slippage was measured intra-operatively after the tensioner was removed using an intra-operative professional camera. Following this study mechanical tests were performed in the lab measuring the pull out properties of Kirchner wires using different bolts and different torque levels in order to tighten the wire on the fixator.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 45 - 45
1 May 2021
Zenios M Oyadiji T Zamani-Farahani A
Full Access

Introduction

A clinical case of catastrophic ring failure in a 13 year old autistic overweight patient during treatment for tibial lengthening and deformity using a Taylor Spatial Frame is reported. Ring failure was noted during the later stages of bone healing and the frame was removed. The clinical outcome was not affected by the catastrophic ring failure.

The photograph of the deformed ring is presented below:

Materials and Methods

The patient's notes and X-rays were reviewed and a macroscopic examination of the deformed ring was performed. Mechanical tests of different Taylor Spatial frame constructs were performed in an attempt to simulate the deformity that was clinically observed. Different constructs of TSF of different ring sizes were fixed to polyurethane cylinders simulating bone, were mechanically tested to failure and load/deflection curves were produced.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 146 - 146
1 Jan 2013
Ul Islam S Henry A Khan T Davis N Zenios M
Full Access

Introduction

Through the paediatric LCP Hip plating system, the highly successful technique of the locking compression plate used in adult surgery, has been incorporated in a system dedicated to paediatrics. The purpose of this study was to review the outcome of the paediatric LCP Hip plate use in children, both with and without neuromuscular disease, for fixation of proximal femoral osteotomy for a variety of indications.

Materials and methods

We retrospectively reviewed the notes and radiographs of all those children who have had Paediatric LCP Hip Plate for the fixation of proximal femoral osteotomy and proximal femur fractures in our institution, between October 2007 and July 2010, for their clinical progress, mobilization status, radiological healing and any complications.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 156 - 156
1 Sep 2012
Lammin K Taylor J Zenios M
Full Access

Background

Osteomyelitis can be difficult to diagnose. Unlike septic arthritis no defined diagnostic criteria exist as a guide. Inflammatory markers are frequently utilized at initial presentation, (in addition to white cell count).

Methods

All radiologically confirmed cases of long bone osteomyelitis without septic arthritis, joint effusion or abscess, in paediatric patients, presenting to one hospital over an eighteen-month period were included. These patients were compared with all culture positive septic arthrides presenting to the same hospital within the same time period. Inflammatory markers taken on the day of admission were studied.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 14 - 14
1 Jul 2012
Islam SU Henry A Khan T Davis N Zenios M
Full Access

Through the paediatric LCP Hip plating system (Synthes GmBH Eimattstrasse 3 CH- 4436 Oberdorff), the highly successful technique of the locking compression plate used in adult surgery, has been incorporated in a system dedicated to pediatrics. We are presenting the outcome of the paediatric LCP hip plating system used for a variety of indications in our institution.

We retrospectively reviewed the notes and radiographs of all those children who have had Paediatric LCP Plate for the fixation of proximal femoral osteotomy and proximal femur fractures in our institution, between October 2007 and July 2010, for their clinical progress, mobilization status, radiological healing and any complications.

Forty-three Paediatric LCP hip plates were used in forty patients (24 males and 13 females) for the fixation of proximal femoral osteotomies (n=40) and proximal femur fractures (n=3). The osteotomies were performed for a variety of indications including Perthes disease, developmental dysplasia of hip, Cerebral Palsy, Down's syndrome, coxa vara, Leg length discrepancy and previous failed treatment of Slipped Upper Femoral Epiphysis.

Twenty-five children were allowed touch to full weight bearing post operatively. Two were kept non-weight bearing for 6 weeks. The remaining 13 children were treated in hip spica due to simultaneous pelvic osteotomy or multilevel surgery for cerebral palsy.

All osteotomies and fractures radiologically healed within 6 months (majority [n=40] within 3 months). There was no statistically significant difference (p= 0.45) in the neck shaft angle between the immediately postoperative and final x-rays after completion of bone healing.

Among the children treated without hip spica, 1 child suffered a periprosthetic fracture. Of the children treated in hip spica, 2 had pressure sores, 3 had osteoporotic distal femur fractures and 2 had posterior subluxations requiring further intervention.

There were no implant related complications.

The Paediatric LCP Hip Plate provides a stable and reliable fixation of the proximal femoral osteotomy performed for a variety of paediatric orthopaedic conditions.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 60 - 60
1 Mar 2012
Zenios M Ramachandran M Milne B Little D Smith N
Full Access

The aims of this study were (1) to assess whether rotational stability testing in Gartland III supracondylar fractures can be used intra-operatively in order to assess fracture stability following fixation with lateral-entry wires and (2) to quantify the incidence of rotational instability following lateral-entry wire fixation in Gartland type III supracondylar humeral fractures in children.

Twenty-one consecutive patients admitted with Grade III supracondylar fractures at the Children's Hospital at Westmead were surgically treated according to a predetermined protocol. Following closed fracture reduction, 2 lateral-entry wires were inserted under radiographic control. Stability was then assessed by comparing lateral x-ray images in internal and external rotation. If the fracture was found to be rotationally unstable by the operating surgeon, a third lateral-entry wire was inserted and images repeated. A medial wire was used only if instability was demonstrated after the insertion of three lateral wires.

Rotational stability was achieved with two lateral-entry wires in 6 cases, three lateral-entry wires in 10 cases and with an additional medial wire in 5 cases. Our results were compared to a control group of 24 patients treated at our hospital prior to introduction of this protocol. No patients returned to theatre following introduction of our protocol as opposed to 6 patients in the control group. On analysis of radiographs, the protocol resulted in significantly less fracture position loss as evidenced by change in Baumann's angle (p<0.05) and lateral rotational percentage (p<0.05).

We conclude that the introduction of rotational stability testing allows intra-operative assessment of fracture fixation. Supracondylar fractures that are rotationally stable intra-operatively following wire fixation are unlikely to displace post-operatively. Only a small proportion (26%) of these fractures were rotationally stable with 2 lateral-entry wires. This may be a reflection of either the fracture configuration or inability to adequately engage the medial column.