Calcaneal osteomyelitis remains a difficult condition to treat with high rates of recurrence and below-knee amputation, particularly in the presence of severe soft-tissue destruction. This study assesses the outcomes of single-stage orthoplastic surgical treatment of calcaneal osteomyelitis with large soft-tissue defects. A retrospective review was performed of all patients who underwent combined single-stage orthoplastic treatment of calcaneal osteomyelitis (01/2008 to 12/2022). Primary outcome measures were osteomyelitis recurrence and below-knee amputation (BKA). Secondary outcome measures included flap failure, operating time, complications, and length of stay.Aims
Methods
Aims. Venous thromboembolism (VTE) is a potential complication of
Advanced 3D imaging and CT-based navigation have emerged as valuable tools to use in total knee arthroplasty (TKA), for both preoperative planning and the intraoperative execution of different philosophies of alignment. Preoperative planning using CT-based 3D imaging enables more accurate prediction of the size of components, enhancing surgical workflow and optimizing the precision of the positioning of components. Surgeons can assess alignment, osteophytes, and arthritic changes better. These scans provide improved insights into the patellofemoral joint and facilitate tibial sizing and the evaluation of implant-bone contact area in cementless TKA. Preoperative CT imaging is also required for the development of patient-specific instrumentation cutting guides, aiming to reduce intraoperative blood loss and improve the surgical technique in complex cases. Intraoperative CT-based navigation and haptic guidance facilitates precise execution of the preoperative plan, aiming for optimal positioning of the components and accurate alignment, as determined by the surgeon’s philosophy. It also helps reduce iatrogenic injury to the periarticular soft-tissue structures with subsequent reduction in the local and systemic inflammatory response, enhancing early outcomes. Despite the increased costs and radiation exposure associated with CT-based navigation, these many benefits have facilitated the adoption of imaged based robotic surgery into routine practice. Further research on ultra-low-dose CT scans and exploration of the possible translation of the use of 3D imaging into improved clinical outcomes are required to justify its broader implementation. Cite this article:
The Manchester-Oxford Foot Questionnaire (MOxFQ) is an anatomically specific patient-reported outcome measure (PROM) currently used to assess a wide variety of foot and ankle pathology. It consists of 16 items across three subscales measuring distinct but related traits: walking/standing ability, pain, and social interaction. It is the most used foot and ankle PROM in the UK. Initial MOxFQ validation involved analysis of 100 individuals undergoing hallux valgus surgery. This project aimed to establish whether an individual’s response to the MOxFQ varies with anatomical region of disease (measurement invariance), and to explore structural validity of the factor structure (subscale items) of the MOxFQ. This was a single-centre, prospective cohort study involving 6,637 patients (mean age 52 years (SD 17.79)) presenting with a wide range of foot and ankle pathologies between January 2013 and December 2021. To assess whether the MOxFQ responses vary by anatomical region of foot and ankle disease, we performed multigroup confirmatory factor analysis. To assess the structural validity of the subscale items, exploratory and confirmatory factor analyses were performed.Aims
Methods
The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes.Aims
Methods
This scoping review aims to identify patient-related factors associated with a poorer outcome following total ankle arthroplasty (TAA). A scoping review was performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A computer-based literature search was performed in PubMed, Embase, Cochrane trials, and Web of Science. Two reviewers independently performed title/abstract and full-text screening according to predetermined selection criteria. English-language original research studies reporting patient-related factors associated with a poorer outcome following TAA were included. Outcomes were defined as patient-reported outcome measures (PROMs), perioperative complications, and failure.Aims
Methods
In the UK, the agricultural, military, and construction sectors have stringent rules about the use of hearing protection due to the risk of noise-induced hearing loss. Orthopaedic staff may also be at risk due to the use of power tools. The UK Health and Safety Executive (HSE) have clear standards as to what are deemed acceptable occupational levels of noise on A-weighted and C-weighted scales. The aims of this review were to assess the current evidence on the testing of exposure to noise in orthopaedic operating theatres to see if it exceeds these regulations. A search of PubMed and EMBASE databases was conducted using PRISMA guidelines. The review was registered prospectively in PROSPERO. Studies which assessed the exposure to noise for orthopaedic staff in operating theatres were included. Data about the exposure to noise were extracted from these studies and compared with the A-weighted and C-weighted acceptable levels described in the HSE regulations.Aims
Methods
To assess the characteristic clinical features, management, and outcome of patients who present to orthopaedic surgeons with functional dystonia affecting the foot and ankle. We carried out a retrospective search of our records from 2000 to 2019 of patients seen in our adult tertiary referral foot and ankle unit with a diagnosis of functional dystonia.Aims
Methods
We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year.Aims
Methods
To assess the effect of age on clinical outcome and revision rates in patients who underwent total ankle arthroplasty (TAA) for end-stage ankle osteoarthritis (OA). A consecutive series of 811 ankles (789 patients) that underwent TAA between May 2003 and December 2013 were enrolled. The influence of age on clinical outcome, including the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, and pain according to the visual analogue scale (VAS) was assessed. In addition, the risk for revision surgery that includes soft tissue procedures, periarticular arthrodeses/osteotomies, ankle joint debridement, and/or inlay exchange (defined as minor revision), as well as the risk for revision surgery necessitating the exchange of any of the metallic components or removal of implant followed by ankle/hindfoot fusion (defined as major revision) was calculated.Aims
Methods
Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR. We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected.Aims
Methods
To evaluate the donor site morbidity and tendon morphology after harvesting whole length, full-thickness peroneus longus tendon (PLT) proximal to the lateral malleolus for ligament reconstructions or tendon transfer. A total of 21 eligible patients (mean age 34.0 years (standard deviation (SD) 11.2); mean follow-up period 31.8 months (SD 7.7), and 12 healthy controls (mean age, 26.8 years (SD 5.9) were included. For patients, clinical evaluation of the donor ankle was performed preoperatively and postoperatively. Square hop test, ankle strength assessment, and MRI of distal calf were assessed bilaterally in the final follow-up. The morphological symmetry of peroneal tendons bilaterally was evaluated by MRI in healthy controls.Aims
Methods
To our knowledge, there is currently no information available about the rate of venous thromboembolism (VTE) or recommendations regarding chemoprophylaxis for patients whose lower limb is immobilized in a plaster cast. We report a retrospective case series assessing the rate of symptomatic VTE in patients treated with a lower limb cast. Given the complex, heterogeneous nature of this group of patients, with many risk factors for VTE, we hypothesized that the rate of VTE would be higher than in the general population. Patients treated with a lower limb cast between 2006 and 2018 were identified using plaster room records. Their electronic records and radiological reports were reviewed for details about their cast, past medical history, and any VTE recorded in our hospital within a year of casting.Aims
Patients and Methods
Total ankle arthroplasty (TAA) surgery is complex and attracts a wide variety of complications. The literature lacks consistency in reporting adverse events and complications. The aim of this article is to provide a comprehensive analysis of each of these complications from a literature review, and to compare them with rates from our Unit, to aid clinicians with the process of informed consent. A total of 278 consecutive total ankle arthroplasties (251 patients), performed by four surgeons over a six-year period in Wrightington Hospital (Wigan, United Kingdom) were prospectively reviewed. There were 143 men and 108 women with a mean age of 64 years (41 to 86). The data were recorded on each follow-up visit. Any complications either during initial hospital stay or subsequently reported on follow-ups were recorded, investigated, monitored, and treated as warranted. Literature search included the studies reporting the outcomes and complications of TAA implants.Aims
Patients and Methods
Increasing innovation in rapid prototyping (RP)
and additive manufacturing (AM), also known as 3D printing, is bringing
about major changes in translational surgical research. This review describes the current position in the use of additive
manufacturing in orthopaedic surgery. Cite this article:
This prospective cohort study aims to determine if the size of
the tendon gap following acute rupture of the Achilles tendon shows
an association with the functional outcome following non-operative
treatment. All patients presenting within two weeks of an acute unilateral
rupture of the Achilles tendon between July 2012 and July 2015 were
considered for the study. In total, 38 patients (nine female, 29
male, mean age 52 years; 29 to 78) completed the study. Dynamic
ultrasound examination was performed to confirm the diagnosis and
measure the gap between ruptured tendon ends. Outcome was assessed
using dynamometric testing of plantarflexion and the Achilles tendon
Total Rupture score (ATRS) six months after the completion of a
rehabilitation programme.Aims
Patients and Methods
Smoking is associated with post-operative complications but smokers
often under-report the amount they smoke. Our objective was to determine
whether a urine dipstick test could be used as a substitute for
quantitative cotinine assays to determine smoking status in patients. Between September 2013 and July 2014 we conducted a prospective
cohort study in which 127 consecutive patients undergoing a planned
foot and ankle arthrodesis or osteotomy were included. Patients
self-reported their smoking status and were classified as: ‘never
smoked’ (61 patients), ‘ex-smoker’ (46 patients), or ‘current smoker’ (20
patients). Urine samples were analysed with cotinine assays and
cotinine dipstick tests.Aims
Patients and Methods
To examine the mid-term outcome and cost utility of the BioPro
metallic hemiarthroplasty for the treatment of hallux rigidius. We reviewed 97 consecutive BioPro metallic hemiarthroplasties
performed in 80 patients for end-stage hallux rigidus, with a minimum
follow-up of five years. There were 19 men and 61 women; their mean
age was 55 years (22 to 74). No patient was lost to follow-up.Aims
Patients and Methods
A new method of vascularised tibial grafting
has been developed for the treatment of avascular necrosis (AVN)
of the talus and secondary osteoarthritis (OA) of the ankle. We
used 40 cadavers to identify the vascular anatomy of the distal
tibia in order to establish how to elevate a vascularised tibial
graft safely. Between 2008 and 2012, eight patients (three male,
five female, mean age 50 years; 26 to 68) with isolated AVN of the
talus and 12 patients (four male, eight female, mean age 58 years;
23 to 76) with secondary OA underwent vascularised bone grafting
from the distal tibia either to revascularise the talus or for arthrodesis.
The radiological and clinical outcomes were evaluated at a mean
follow-up of 31 months (24 to 62). The peri-malleolar arterial arch
was confirmed in the cadaveric study. A vascularised bone graft
could be elevated safely using the peri-malleolar pedicle. The clinical
outcomes for the group with AVN of the talus assessed with the mean
Mazur ankle grading scores, improved significantly from 39 points
(21 to 48) pre-operatively to 81 points (73 to 90) at the final
follow-up (p = 0.01). In all eight revascularisations, bone healing
was obtained without progression to talar collapse, and union was
established in 11 of 12 vascularised arthrodeses at a mean follow-up
of 34 months (24 to 58). MRI showed revascularisation of the talus
in all patients. We conclude that a vascularised tibial graft can be used both
for revascularisation of the talus and for the arthrodesis of the
ankle in patients with OA secondary to AVN of the talus. Cite this article: