Aims. Day-case knee and hip replacement, in which patients are discharged on the day of surgery, has been gaining popularity during the last two decades, and particularly since the COVID-19 pandemic. This systematic review presents the evidence comparing day-case to inpatient-stay surgery. Methods. A systematic literature search was performed of MEDLINE, Embase, and grey literature databases to include all studies which compare day-case with inpatient knee and hip replacement. Meta-analyses were performed where appropriate using a random effects model. The protocol was registered prospectively (PROSPERO CRD42023392811). Results. A total of 38 studies were included, with a total of 83,888 day-case procedures. The studies were predominantly from the USA and Canada, observational, and with a high risk of bias. Day-case patients were a mean of 2.08 years younger (95% CI 1.05 to 3.12), were more likely to be male (odds ratio (OR) 1.3 (95% CI 1.19 to 1.41)), and had a lower mean BMI and American Society of Anesthesiologists grades compared with inpatients. Overall, day-case surgery was associated with significantly lower odds of readmission (OR 0.83 (95% CI 0.73 to 0.96); p = 0.009), subsequent emergency department attendance (OR 0.62 (95% CI 0.48 to 0.79); p < 0.001), and complications (OR 0.7 (95% CI 0.55 to 0.89) p = 0.004), than inpatient surgery. There were no significant differences in the rates of reoperation or mortality. The overall rate of successful same-day discharge for day-case surgery was 85% (95% CI 81 to 88). Patient-reported outcome measures and cost-effectiveness were either equal or favoured day-case. Conclusion. Within the limitations of the literature, in particular the substantial risk of selection bias, the outcomes following day-case knee and hip replacement appear not to be inferior to those following an inpatient stay. The evidence is more robust for unicompartmental knee replacement (UKR) than for total knee replacement (TKR) or total hip replacement (THR). The rate of successful same-day discharge is highest in UKR, followed by TKR and comparatively lower in
Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components. A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties.Aims
Materials and Methods
Excision of the proximal femur for tumour with
prosthetic reconstruction using a bipolar femoral head places a considerable
load on the unreplaced acetabulum. We retrospectively reviewed the changes which occur around the
affected hip joint by evaluating the post-operative radiographs
of 65 consecutive patients who underwent proximal prosthetic arthroplasty
of the femur, and in whom an acetabular component had not been used.
There were 37 men and 28 women with a mean age of 57.3 years (17
to 93). Radiological assessment included the extent of degenerative
change in the acetabulum, heterotopic ossification, and protrusio
acetabuli. The mean follow-up was 9.1 years (2 to 11.8). Degenerative changes
in the acetabulum were seen in three patients (4.6%), Brooker grade
1 or 2 heterotopic ossification in 17 (26%) and protrusion of the
prosthetic head in nine (13.8%). A total of eight patients (12.3%) needed a revision. Five were
revised to the same type of prosthesis and three (4.6%) were converted
to a total hip arthroplasty. We conclude that radiological evidence of degenerative change,
heterotopic ossification and protrusion occur in a few patients
who undergo prosthetic arthroplasty of the proximal femur for tumour.
The limited extent of these changes and the lack of associated symptoms
do not justify the routine arthroplasty of the acetabulum in these patients. Cite this article:
The aim of this study was to investigate the
relationship between the geometry of the proximal femur and the incidence
of intra-operative fracture during uncemented total hip arthroplasty
(THA). We studied the pre-operative CT scans of 100 patients undergoing
THA with an uncemented femoral component. We measured the anteroposterior
and mediolateral dimensions at the level of division of the femoral
neck to calculate the aspect ratio of the femur. Wide variations
in the shape of the femur were observed, from round, to very narrow
elliptic. The femurs of women were narrower than those of men (p
<
0.0001) and small femurs were also narrower than large ones.
Patients with an intra-operative fracture of the calcar had smaller
and narrower femurs than those without a fracture (p <
0.05)
and the implanted Corail stems were smaller in those with a fracture
(mean size 9 The variability of the shape of the femoral neck at the level
of division contributes to the understanding of the causation of
intra-operative fractures in uncemented THA. Cite this article:
National Institute of Clinical Excellence guidelines
state that cemented stems with an Orthopaedic Data Evaluation Panel
(ODEP) rating of >
3B should be used for hemiarthroplasty when treating
an intracapsular fracture of the femoral neck. These recommendations
are based on studies in which most, if not all stems, did not hold
such a rating. This case-control study compared the outcome of hemiarthroplasty
using a cemented (Exeter) or uncemented (Corail) femoral stem. These
are the two prostheses most commonly used in hip arthroplasty in
the UK. Data were obtained from two centres; most patients had undergone
hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients
were matched for all factors that have been shown to influence mortality
after an intracapsular fracture of the neck of the femur. Outcome
measures included: complications, re-operations and mortality rates
at two, seven, 30 and 365 days post-operatively. Comparable outcomes
for the two stems were seen. There were more intra-operative complications in the uncemented
group (13% This study therefore supports the use of both cemented and uncemented
stems of proven design, with an ODEP rating of 10A, in patients
with an intracapsular fracture of the neck of the femur. Cite this article:
We investigated the incidence of soft-tissue
lesions after small head metal-on-metal total hip replacement (MoM THR).
Between December 1993 and May 1999, 149 patients (195 hips) underwent
primary cementless MoM
We conducted a retrospective study to assess
the prevalence of adverse reactions to metal debris (ARMD) in patients
operated on at our institution with metal-on-metal (MoM) total hip
replacements with 36 mm heads using a Pinnacle acetabular shell.
A total of 326 patients (150 males, 175 hips; 176 females, 203 hips)
with a mean age of 62.7 years (28 to 85) and mean follow-up of 7.5
years (0.1 to 10.8) participating in our in-depth modern MoM follow-up
programme were included in the study, which involved recording whole
blood cobalt and chromium ion measurements, Oxford hip scores (OHS)
and plain radiographs of the hip and targeted cross-sectional imaging. Elevated
blood metal ion levels (>
5 parts per billion) were seen in 32 (16.1%)
of the 199 patients who underwent unilateral replacement. At 23
months after the start of our modern MoM follow-up programme, 29
new cases of ARMD had been revealed. Hence, the nine-year survival
of this cohort declined from 96% (95% CI 95 to 98) with the old
surveillance routine to 86% (95% CI 82 to 90) following the new
protocol. Although ARMD may not be as common in 36 mm MoM THRs as
in those with larger heads, these results support the Medicines
and Healthcare Products Regulatory Agency guidelines on regular
reviews and further investigations, and emphasise the need for specific
a follow-up programme for patients with MoM THRs. Cite this article:
We present detailed information about early morbidity
after aseptic revision knee replacement from a nationwide study.
All aseptic revision knee replacements undertaken between 1st October
2009 and 30th September 2011 were analysed using the Danish National
Patient Registry with additional information from the Danish Knee
Arthroplasty Registry. The 1218 revisions involving 1165 patients
were subdivided into total revisions, large partial revisions, partial
revisions and revisions of unicondylar replacements (UKR revisions).
The mean age was 65.0 years (27 to 94) and the median length of
hospital stay was four days (interquartile range: 3 to 5), with
a 90 days re-admission rate of 9.9%,
re-operation rate of 3.5% and mortality rate of 0.2%. The age ranges
of 51 to 55 years (p = 0.018), 76 to 80 years (p <
0.001) and ≥ 81
years (p <
0.001) were related to an increased risk of re-admission.
The age ranges of 76 to 80 years (p = 0.018) and the large partial
revision subgroup (p = 0.073) were related to an increased risk
of re-operation. The ages from 76 to 80 years (p <
0.001), age ≥ 81
years (p <
0.001) and surgical time >
120 min (p <
0.001)
were related to increased length of hospital stay, whereas the use
of a tourniquet (p = 0.008) and surgery in a low volume centre (p
= 0.013) were related to shorter length of stay. In conclusion, we found a similar incidence of early post-operative
morbidity after aseptic knee revisions as has been reported after
primary procedures. This suggests that a length of hospital stay ≤ four
days and discharge home at that time is safe following aseptic knee
revision surgery in Denmark. Cite this article:
Intact abductors of the hip play a crucial role
in preventing limping and are known to be damaged through the direct lateral
approach. The extent of trauma to the abductors after revision total
hip replacement (THR) is unknown. The aim of this prospective study
was to compare the pre- and post-operative status of the gluteus
medius muscle after revision
We undertook a retrospective cohort study to
determine clinical outcomes following the revision of metal-on-metal (MoM)
hip replacements for adverse reaction to metal debris (ARMD), and
to identify predictors of time to revision and outcomes following
revision. Between 1998 and 2012 a total of 64 MoM hips (mean age
at revision of 57.8 years; 46 (72%) female; 46 (72%) hip resurfacings
and 18 (28%) total hip replacements) were revised for ARMD at one specialist
centre. At a mean follow-up of 4.5 years (1.0 to 14.6) from revision
for ARMD there were 13 hips (20.3%) with post-operative complications
and eight (12.5%) requiring re-revision. The Kaplan–Meier five-year survival rate for ARMD revision was
87.9% (95% confidence interval 78.9 to 98.0; 19 hips at risk). Excluding
re-revisions, the median absolute Oxford hip score (OHS) following
ARMD revision using the percentage method (0% best outcome and 100%
worst outcome) was 18.8% (interquartile range (IQR) 7.8% to 48.3%),
which is equivalent to 39/48 (IQR 24.8/48 to 44.3/48) when using
the modified OHS. Histopathological response did not affect time
to revision for ARMD (p = 0.334) or the subsequent risk of re-revision
(p = 0.879). Similarly, the presence or absence of a contralateral
MoM hip bearing did not affect time to revision for ARMD (p = 0.066)
or the subsequent risk of re-revision (p = 0.178). Patients revised to MoM bearings had higher rates of re-revision
(five of 16 MoM hips re-revised; p = 0.046), but those not requiring
re-revision had good functional results (median absolute OHS 14.6%
or 41.0/48). Short-term morbidity following revision for ARMD was
comparable with previous reports. Caution should be exercised when choosing
bearing surfaces for ARMD revisions. Cite this article:
The aim of this study was to define return to
theatre (RTT) rates for elective hip and knee replacement (HR and
KR), to describe the predictors and to show the variations in risk-adjusted
rates by surgical team and hospital using national English hospital
administrative data. We examined information on 260 206 HRs and 315 249 KRs undertaken
between April 2007 and March 2012. The 90-day RTT rates were 2.1%
for HR and 1.8% for KR. Male gender, obesity, diabetes and several
other comorbidities were associated with higher odds for both index
procedures. For HR, hip resurfacing had half the odds of cement fixation
(OR = 0.58, 95% confidence intervals (CI) 0.47 to 0.71). For KR,
unicondylar KR had half the odds of total replacement (OR = 0.49,
95% CI 0.42 to 0.56), and younger ages had higher odds (OR = 2.23,
95% CI 1.65 to 3.01) for ages <
40 years compared with ages 60
to 69 years). There were more funnel plot outliers at three standard deviations
than would be expected if variation occurred on a random basis. Hierarchical modelling showed that three-quarters of the variation
between surgeons for HR and over half the variation between surgeons
for KR are not explained by the hospital they operated at or by
available patient factors. We conclude that 90-day RTT rate may
be a useful quality indicator for orthopaedics. Cite this article:
Total knee replacement (TKR) is an effective
method of treating end-stage arthritis of the knee. It is not, however,
a procedure without risk due to a number of factors, one of which
is diabetes mellitus. The purpose of this study was to estimate
the general prevalence of diabetes in patients about to undergo
primary TKR and to determine whether diabetes mellitus adversely
affects the outcome. We conducted a systematic review and meta-analysis
according to the Meta-analysis Of Observational Studies in Epidemiology
(MOOSE) guidelines. The Odds Ratio (OR) and mean difference (MD)
were used to represent the estimate of risk of a specific outcome.
Our results showed the prevalence of diabetes mellitus among patients
undergoing TKR was 12.2%. Patients with diabetes mellitus had an increased
risk of deep infection (OR = 1.61, 95% confidence interval (CI),
1.38 to 1.88), deep vein thrombosis (in Asia, OR = 2.57, 95% CI,
1.58 to 4.20), periprosthetic fracture (OR = 1.89, 95% CI, 1.04
to 3.45), aseptic loosening (OR = 9.36, 95% CI, 4.63 to 18.90),
and a poorer Knee Society function subscore (MD = -5.86, 95% CI,
-10.27 to -1.46). Surgeons should advise patients specifically about
these increased risks when obtaining informed consent and be meticulous about
their peri-operative care. Cite this article:
Large femoral heads have become popular in total
hip replacement (THR) as a method of reducing the risk of dislocation.
However, if large heads are used in ceramic-on-ceramic
We are currently facing an epidemic of periprosthetic
fractures around the hip. They may occur either during surgery or
post-operatively. Although the acetabulum may be involved, the femur
is most commonly affected. We are being presented with new, difficult
fracture patterns around cemented and cementless implants, and we
face the challenge of an elderly population who may have grossly
deficient bone and may struggle to rehabilitate after such injuries.
The correct surgical management of these fractures is challenging.
This article will review the current choices of implants and techniques
available to deal with periprosthetic fractures of the femur. Cite this article:
Degenerative problems of the hip in patients
with childhood and adult onset neuromuscular disorders can be challenging
to treat. Many orthopaedic surgeons are reluctant to recommend total
hip replacement (THR) for patients with underlying neuromuscular
disorders due to the perceived increased risks of dislocation, implant loosening,
and lack of information about the functional outcomes and potential
benefits of these procedures in these patients. Modular femoral
components and alternative bearings which facilitate the use of
large femoral heads, constrained acetabular components and perhaps
more importantly, a better understanding about the complications
and outcomes of
Dislocation remains among the most common complications
of, and reasons for, revision of both primary and revision total
hip replacements (THR). Hence, there is great interest in maximising
stability to prevent this complication. Head size has been recognised
to have a strong influence on the risk of dislocation post-operatively.
As femoral head size increases, stability is augmented, secondary
to an increase in impingement-free range of movement. Larger head
sizes also greatly increase the ‘jump distance’ required for the
head to dislocate in an appropriately positioned cup. Level-one
studies support the use of larger diameter heads as they decrease
the risk of dislocation following primary and revision
Surgical interventions consisting of internal
fixation (IF) or total hip replacement (THR) are required to restore
patient mobility after hip fractures. Conventionally, this decision
was based solely upon the degree of fracture displacement. However,
in the last ten years, there has been a move to incorporate patient
characteristics into the decision making process. Research demonstrating
that joint replacement renders superior functional results when compared
with IF, in the treatment of displaced femoral neck fractures, has
swayed the pendulum in favour of
Although patients with a history of venous thromboembolism
(VTE) who undergo lower limb joint replacement are thought to be
at high risk of further VTE, the actual rate of recurrence has not
been reported. The purpose of this study was to identify the recurrence rate
of VTE in patients who had undergone lower limb joint replacement,
and to compare it with that of patients who had undergone a joint
replacement without a history of VTE. . From a pool of 6646 arthroplasty procedures (3344 TKR, 2907
Data on early morbidity and complications after
revision total hip replacement (THR) are limited. The aim of this nationwide
study was to describe and quantify early morbidity after aseptic
revision
We report the clinical and radiological outcome
of subcapital osteotomy of the femoral neck in the management of symptomatic
femoroacetabular impingement (FAI) resulting from a healed slipped
capital femoral epiphysis (SCFE). We believe this is only the second
such study in the literature. We studied eight patients (eight hips) with symptomatic FAI after
a moderate to severe healed SCFE. There were six male and two female
patients, with a mean age of 17.8 years (13 to 29). All patients underwent a subcapital intracapsular osteotomy of
the femoral neck after surgical hip dislocation and creation of
an extended retinacular soft-tissue flap. The mean follow-up was
41 months (20 to 84). Clinical assessment included measurement of
range of movement, Harris Hip Score (HHS) and Western Ontario and McMaster
Universities Osteoarthritis score (WOMAC). Radiological assessment
included pre- and post-operative calculation of the anterior slip
angle (ASA) and lateral slip angle (LSA), the anterior offset angle
(AOA) and centre head–trochanteric distance (CTD). The mean HHS
at final follow-up was 92.5 (85 to 100), and the mean WOMAC scores
for pain, stiffness and function were 1.3 (0 to 4), 1.4 (0 to 6)
and 3.6 (0 to 19) respectively. There was a statistically significant
improvement in all the radiological measurements post-operatively.
The mean ASA improved from 36.6° (29° to 44°) to 10.3° (5° to 17°)
(p <
0.01). The mean LSA improved from 36.6° (31° to 43°) to 15.4°
(8° to 21°) (p <
0.01). The mean AOA decreased from 64.4° (50°
to 78°) 32.0° (25° to 39°) post-operatively (p <
0.01). The mean
CTD improved from -8.2 mm (-13.8 to +3.1) to +2.8 mm (-7.6 to +11.0)
(p <
0.01). Two patients underwent further surgery for nonunion.
No patient suffered avascular necrosis of the femoral head. Subcapital osteotomy for patients with a healed SCFE is more
challenging than subcapital re-orientation in those with an acute
or sub-acute SCFE and an open physis. An effective correction of
the deformity, however, can be achieved with relief of symptoms
related to impingement. Cite this article: