Advertisement for orthosearch.org.uk
Results 1 - 20 of 87
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 751 - 758
1 Jul 2024
Yaxier N Zhang Y Song J Ning B

Aims

Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when limb lengthening is undertaken in paediatric patients. The aim of this study was to assess the use of ultrasound combined with SMI in monitoring new bone formation during limb lengthening in children.

Methods

In this retrospective cohort study, ultrasound and radiograph examinations were performed every two weeks in 30 paediatric patients undergoing limb lengthening. Ultrasound was used to monitor new bone formation. The number of vertical vessels and the blood flow resistance index were compared with those from plain radiographs.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims. As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach. Methods. A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30). Results. A median tibial distraction of 44 mm (IQR 31 to 49) was achieved with a mean distraction index of 0.5 mm/day (standard deviation 0.13) and median consolidation index of 41.2 days/cm (IQR 34 to 51). Accuracy, precision, and reliability were 91%, 92%, and 97%, respectively. New temporary range of motion limitations occurred in 51% of segments (34/67). Distraction-related equinus deformity treated by Achilles tendon lengthening was the most common major complication recorded in 16% of segments (11/67). In 95% of patients (55/58) the distraction goal was achieved with 42% unplanned additional interventions per segment (28/67). The median postoperative LD-SRS-30 score was 4.0 (IQR 3.6 to 4.3). Conclusion. Tibial distraction osteogenesis using motorized ILNs inserted via an antegrade approach appears to be a reliable and precise procedure. Temporary joint stiffness of the knee or ankle should be expected in up to every second patient. A high rate and wide range of complications of variable severity should be anticipated. Cite this article: Bone Joint J 2024;106-B(3):293–302


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 88 - 96
1 Jan 2023
Vogt B Rupp C Gosheger G Eveslage M Laufer A Toporowski G Roedl R Frommer A

Aims. Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences. Methods. A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages. Results. Osteolysis next to the telescopic junction was observed in 31/48 segments (65%) lengthened with the STRYDE nail before implant removal compared to 1/91 segment (1%) in the PRECICE cohort. In the STRYDE cohort, osteolysis initially increased, but decreased or resolved in almost all lengthened segments (86%) after implant removal. Implant failure was observed in 9/48 STRYDE (19%) and in 8/92 PRECICE nails (9%). Breakage of the distal locking bolts was found in 5/48 STRYDE nails (10%) compared to none in the PRECICE cohort. Treatment-associated pain was generally recorded as mild and found in 30/48 patients (63%) and 39/92 (42%) in the STRYDE and PRECICE cohorts, respectively. Temporary range of motion (ROM) limitations under distraction were registered in 17/48 (35%) segments treated with the STRYDE and 35/92 segments (38%) treated with the PRECICE nail. Conclusion. Osteolysis and periosteal reaction, implant breakage, and pain during lengthening and consolidation is more likely in patients treated with the STRYDE nail compared to the PRECICE nail. Temporary ROM limitations during lengthening occurred independent of the applied device. Implant-related osseous alterations seem to remodel after implant removal. Cite this article: Bone Joint J 2023;105-B(1):88–96


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1273 - 1278
1 Nov 2022
Chowdhury JMY Ahmadi M Prior CP Pease F Messner J Foster PAL

Aims

The aim of this retrospective cohort study was to assess and investigate the safety and efficacy of using a distal tibial osteotomy compared to proximal osteotomy for limb lengthening in children.

Methods

In this study, there were 59 consecutive tibial lengthening and deformity corrections in 57 children using a circular frame. All were performed or supervised by the senior author between January 2013 and June 2019. A total of 25 who underwent a distal tibial osteotomy were analyzed and compared to a group of 34 who had a standard proximal tibial osteotomy. For each patient, the primary diagnosis, time in frame, complications, and lengthening achieved were recorded. From these data, the frame index was calculated (days/cm) and analyzed.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1168 - 1172
1 Jun 2021
Iliadis AD Wright J Stoddart MT Goodier WD Calder P

Aims

The STRYDE nail is an evolution of the PRECICE Intramedullary Limb Lengthening System, with unique features regarding its composition. It is designed for load bearing throughout treatment in order to improve patient experience and outcomes and allow for simultaneous bilateral lower limb lengthening. The literature published to date is limited regarding outcomes and potential problems. We report on our early experience and raise awareness for the potential of adverse effects from this device.

Methods

This is a retrospective review of prospective data collected on all patients treated in our institution using this implant. We report the demographics, nail accuracy, reliability, consolidation index, and cases where concerning clinical and radiological findings were encountered. There were 14 STRYDE nails implanted in nine patients (three male and six female) between June 2019 and September 2020. Mean age at surgery was 33 years (14 to 65). Five patients underwent bilateral lengthening (two femoral and three tibial) and four patients unilateral femoral lengthening for multiple aetiologies.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims

To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes.

Methods

A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1248 - 1255
1 Sep 2020
Laufer A Frommer A Gosheger G Roedl R Broeking JN Toporowski G Rachbauer AM Vogt B

Aims

The treatment of tibial aplasia is controversial. Amputation represents the gold standard with good functional results, but is frequently refused by the families. In these patients, treatment with reconstructive limb salvage can be considered. Due to the complexity of the deformity, this remains challenging and should be staged. The present study evaluated the role of femoro-pedal distraction using a circular external fixator in reconstructive treatment of tibial aplasia. The purpose of femoro-pedal distraction is to realign the limb and achieve soft tissue lengthening to allow subsequent reconstructive surgery.

Methods

This was a retrospective study involving ten patients (12 limbs) with tibial aplasia, who underwent staged reconstruction. During the first operation a circular hexapod external fixator was applied and femoro-pedal distraction was undertaken over several months. Subsequent surgery included reconstruction of the knee joint and alignment of the foot.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1416 - 1422
1 Nov 2019
Rohilla R Sharma PK Wadhwani J Rohilla S Beniwal R Singh R Devgan A

Aims

In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia.

Patients and Methods

Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1144 - 1150
1 Sep 2019
Tsuda Y Fujiwara T Sree D Stevenson JD Evans S Abudu A

Aims

The aim of this study was to report the results of custom-made endoprostheses with extracortical plates plus or minus a short, intramedullary stem aimed at preserving the physis after resection of bone sarcomas in children.

Patients and Methods

Between 2007 and 2017, 18 children aged less than 16 years old who underwent resection of bone sarcomas, leaving ≤ 5 cm of bone from the physis, and reconstruction with a custom-made endoprosthesis were reviewed. Median follow-up was 67 months (interquartile range 45 to 91). The tumours were located in the femur in 11 patients, proximal humerus in six, and proximal tibia in one.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 755 - 760
1 Jun 2018
Lou T Hamushan M Li H Wang C Chai Y Han P

Aims. The aim of this study was to describe the technique of distraction osteogenesis followed by arthrodesis using internal fixation to manage complex conditions of the ankle, and to present the results of this technique. Patients and Methods. Between 2008 and 2014, distraction osteogenesis followed by arthrodesis using internal fixation was performed in 12 patients with complex conditions of the ankle due to trauma or infection. There were eight men and four women: their mean age was 35 years (23 to 51) at the time of surgery. Bone healing and functional recovery were evaluated according to the criteria described by Paley. Function was assessed using the ankle-hindfoot scale of the American Orthopedic Foot and Ankle Society (AOFAS). Results. A solid fusion of the ankle and eradication of infection was achieved in all patients. A mean lengthening of 6.1 cm (2.5 to 14) was achieved at a mean follow-up of 25.2 months (14 to 37). The mean external fixation index (EFI) was 42 days/cm (33.3 to 58). The function was judged to be excellent in six patients and good in six patients. Bone results were graded as excellent in ten patients and good in two patients. The mean AOFAS score was 37.3 (5 to 77) preoperatively and 75.3 (61 to 82) at the final follow-up. Minor complications, which were treated conservatively, included pain, pin-tract infection, loosening of wires, and midfoot stiffness. Major complications, which were treated surgically included grade V pin-tract infection with inflammation and osteolysis, poor consolidation of the regenerate bone, and soft-tissue invagination. The reoperations required to treat the major complications included the exchange of pins and wires, bone grafting and invagination split surgery. Conclusion. The technique of distraction osteogenesis followed by arthrodesis using internal fixation is an effective form of treatment for the management of complex conditions of the ankle. It offers a high rate of union, an opportunity to remove the frame early, and a reduced EFI without infection or wound dehiscence. Cite this article: Bone Joint J 2018;100-B:755–60


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 634 - 639
1 May 2018
Davda K Heidari N Calder P Goodier D

Aims. The management of a significant bony defect following excision of a diaphyseal atrophic femoral nonunion remains a challenge. We present the outcomes using a combined technique of acute femoral shortening, stabilized with a long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis with a temporary monolateral fixator. Patients and Methods. Eight men and two women underwent the ‘rail and nail’ technique between 2008 and 2016. Proximal locking of the nail and removal of the external fixator was undertaken once the length of the femur had been restored and prior to full consolidation of the regenerate. Results. The mean lengthening was 7 cm (3 to 11). The external fixator was removed at a mean of 127 days (57 to 220). The mean bone healing index was 28 days/cm and the mean external fixation index was 20 days/cm (11 to 18). There were no superficial or deep infections. Conclusion. This small retrospective study shows encouraging results for a combined technique, enabling compression of the femoral osteotomy, alignment, and controlled lengthening. Removal of the fixator and proximal locking of the nail reduces the risk of complications and stabilizes the femur with the maximum working length of the nail. Cite this article: Bone Joint J 2018;100-B:634–9


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims

This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect.

Patients and Methods

A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 378 - 386
1 Mar 2018
Campanacci DA Totti F Puccini S Beltrami G Scoccianti G Delcroix L Innocenti M Capanna R

Aims

After intercalary resection of a bone tumour from the femur, reconstruction with a vascularized fibular graft (VFG) and massive allograft is considered a reliable method of treatment. However, little is known about the long-term outcome of this procedure. The aims of this study were to determine whether the morbidity of this procedure was comparable to that of other reconstructive techniques, if it was possible to achieve a satisfactory functional result, and whether biological reconstruction with a VFG and massive allograft could achieve a durable, long-lasting reconstruction.

Patients and Methods

A total of 23 patients with a mean age of 16 years (five to 40) who had undergone resection of an intercalary bone tumour of the femur and reconstruction with a VFG and allograft were reviewed clinically and radiologically. The mean follow-up was 141 months (24 to 313). The mean length of the fibular graft was 18 cm (12 to 29). Full weight-bearing without a brace was allowed after a mean of 13 months (seven to 26).


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 680 - 685
1 May 2017
Morris R Hossain M Evans A Pallister I

Aims

This study describes the use of the Masquelet technique to treat segmental tibial bone loss in 12 patients.

Patients and Methods

This retrospective case series reviewed 12 patients treated between 2010 and 2015 to determine their clinical outcome. Patients were mostly male with a mean age of 36 years (16 to 62). The outcomes recorded included union, infection and amputation. The mean follow-up was 675 days (403 to 952).


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 686 - 696
1 May 2017
Stihsen C Panotopoulos J Puchner SE Sevelda F Kaider A Windhager R Funovics PT

Aims

Few studies dealing with chondrosarcoma of the pelvis are currently available. Different data about the overall survival and prognostic factors have been published but without a detailed analysis of surgery-related complications. We aimed to analyse the outcome of a series of pelvic chondrosarcomas treated at a single institution, with particular attention to the prognostic factors. Based on a competing risk model, our objective was to identify risk factors for the development of complications.

Patients and Methods

In a retrospective single-centre study, 58 chondrosarcomas (26 patients alive, 32 patients dead) of the pelvis were reviewed. The mean follow-up was 13 years (one week to 23.1 years).


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 417 - 418
1 Apr 2017
Haddad FS


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 494 - 502
1 Apr 2017
Simpson AHRW Keenan G Nayagam S Atkins RM Marsh D Clement ND

Aims. The aim of this double-blind prospective randomised controlled trial was to assess whether low intensity pulsed ultrasound (LIPUS) accelerated or enhanced the rate of bone healing in adult patients undergoing distraction osteogenesis. Patients and Methods. A total of 62 adult patients undergoing limb lengthening or bone transport by distraction osteogenesis were randomised to treatment with either an active (n = 32) or a placebo (n = 30) ultrasound device. A standardised corticotomy was performed in the proximal tibial metaphysis and a circular Ilizarov frame was used in all patients. The rate of distraction was also standardised. The primary outcome measure was the time to removal of the frame after adjusting for the length of distraction in days/cm for both the per protocol (PP) and the intention-to-treat (ITT) groups. The assessor was blinded to the form of treatment. A secondary outcome was to identify covariates affecting the time to removal of the frame. Results. There was no difference in the time to removal of the frame between the PP (difference in favour of the control group was 10.1 days/cm, 95% confidence interval (CI) -3.2 to 23.4, p = 0.054) or ITT (difference 5.0 days/cm, 95% CI -8.2 to 18.21, p = 0.226) groups. The smoking status was the only covariate which increased the time to removal of the frame (hazard ratio 0.47, 95% CI 0.22 to 0.97, p = 0.042). Conclusion. LIPUS does not influence the rate of bone healing in patients who undergo distraction osteogenesis. Smoking may influence bone healing. . Cite this article: Bone Joint J 2017;99-B:494–502


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 204 - 210
1 Feb 2017
Xu J Jia Y Kang Q Chai Y

Aims

To present our experience of using a combination of intra-articular osteotomy and external fixation to treat different deformities of the knee.

Patients and Methods

A total of six patients with a mean age of 26.5 years (15 to 50) with an abnormal hemi-joint line convergence angle (HJLCA) and mechanical axis deviation (MAD) were included. Elevation of a tibial hemiplateau or femoral condylar advancement was performed and limb lengthening with correction of residual deformity using a circular or monolateral Ilizarov frame.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1399 - 1405
1 Oct 2016
Rohilla R Wadhwani J Devgan A Singh R Khanna M

Aims

This is a prospective randomised study which compares the radiological and functional outcomes of ring and rail fixators in patients with an infected gap (> 3 cm) nonunion of the tibia.

Patients and Methods

Between May 2008 and February 2013, 70 patients were treated at our Institute for a posttraumatic osseocutaneous defect of the tibia measuring at least 3 cm. These were randomised into two groups of 35 patients using the lottery method. Group I patients were treated with a ring fixator and group II patients with a rail fixator. The mean age was 33.2 years (18 to 64) in group I and 29.3 years (18 to 65) in group II. The mean bone gap was 5.84 cm in group I and 5.78 cm in group II.

The mean followup was 33.8 months in group I and 32.6 months in group II. Bone and functional results were assessed using the classification of the Association for the Study and Application of the Method of Ilizarov (ASAMI). Functional results were also assessed at six months using the short musculoskeletal functional assessment (SMFA) score.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims

Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages.

Patients and Methods

We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared.