We describe a new surgical technique for the
treatment of lacerations of the
The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of
Simple decompression of the
A case of Dupuytren's contracture is described, in which, both clinically and histologically, knuckle pad lesions involved the
We studied the origin of extensor carpi radialis brevis using 40 fresh frozen human cadaver specimens. Ten were stained with haematoxylin and eosin and trichrome which showed the collagenous structure of the
Penetration of the dorsal screw when treating
distal radius fractures with volar locking plates is an avoidable complication
that causes lesions of the
The blood supply of the flexor and
1. This clinical investigation compares the results with varying periods of immobilisation after the primary repair of
Traumatic tenosynovitis of the wrist extensors is a common and disabling condition associated with overuse. It has been found to be associated with hypertrophy of the bellies of abductor pollicis longus and extensor pollicis brevis where they overlie the radial
We performed a lateral approach for the release of post-traumatic stiffness of the elbow in 22 patients using a modified technique designed to spare the lateral ligaments. They were reviewed after a mean interval of 26 months. The total humeroulnar joint movement had increased from a mean of 74° to 129° and forearm rotation from a mean of 135° to 159°. Both pain and function in the elbow had improved significantly. This modified lateral approach allows release of post-traumatic contracture without disruption of the lateral collateral ligament or the origins of the
Arthrodesis of the wrist is a standard operation which is indicated for severe rheumatoid arthritis in which destruction is too advanced for more conservative procedures, or after failure of previous surgery. We have developed an L-shaped plate designed for this purpose. It provides rigid internal fixation with the wrist in the neutral position and utilises bone grafts obtained from the distal ulna and the carpal bones. We have carried out 29 successful fusions between 1992 and 1995. In all 29 patients synovectomy and resection of the head of the ulna were performed; 11 also had reconstruction of ruptured
To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour. A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared.Aims
Methods
1. A medial approach is preferred for arthrodesis of the wrist in reconstructive surgery because there is no interference with the
1. The normal vascular anatomy of flexor
1. A new procedure, called "the extensor diversion graft operation", has been devised for correcting the deformity and reducing the disability of the intrinsic minus fingers so commonly seen in leprosy. 2. The procedure consists of the insertion of a free tendon graft which spans the metacarpophalangeal joint along its volar aspect and is attached at both ends to the extensor mechanism, to the
1 . The extensor assembly of the fingers consists of the central tendon joined by three pairs of components: a) the retinacular ligaments, which link the movements of the interphalangeal joints; b) the "wing" tendons, a lumbrical on the radial side, and usually a palmar interosseous on the ulnar side; c) the phalangeal tendons, usually dorsal interossei. 2. The retinacular ligaments are relaxed in full extension of the proximal interphalangeal joints and are, in this position, unable to extend the distal joints fully. This is because the interphalangeal joint surfaces are eccentric. 3. The pull of the wing tendons alters the shape of the extensor expansion and transfers the pull of the long
The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.Aims
Methods
1. A case is described in which the
The aim of this study was to evaluate two hypotheses. First,
that disruption of posterior bundle of the medial collateral ligament
(PMCL) has to occur for the elbow to subluxate in cases of posteromedial
rotatory instability (PMRI) and second, that ulnohumeral contact
pressures increase after disruption of the PMCL. Six human cadaveric elbows were prepared on a custom-designed
apparatus which allowed muscle loading and passive elbow motion
under gravitational varus. Joint contact pressures were measured
sequentially in the intact elbow (INTACT), followed by an anteromedial
subtype two coronoid fracture (COR), a lateral collateral ligament (LCL)
tear (COR + LCL), and a PMCL tear (COR + LCL + PMCL).Aims
Materials and Methods