We randomised 120 patients who were undergoing either primary total hip or knee arthroplasty to receive either ferrous sulphate or a placebo for three weeks after surgery. The level of haemoglobin and absolute reticulocyte count were measured at one and five days, and three and six weeks after operation. Ninety-nine patients (ferrous sulphate 50, placebo 49) completed the study. The two groups differed only in the treatment administered. Recovery of level of haemoglobin was similar at five days and three weeks and returned to 85% of the pre-operative level, irrespective of the treatment group. A small, albeit greater recovery in the level of haemoglobin was identified at six weeks in the ferrous sulphate group in both men (ferrous sulphate 5%, placebo 1.5%) and women (ferrous sulphate 6%, placebo 3%). The clinical significance of this is questionable and may be outweighed by the high incidence of reported side effects of oral
Haemophilic arthropathy is characterised by
We explored the role of
After total hip and knee replacement arthoplasty, patients may become anaemic and may be prescribed oral
Telehealth has the potential to change the way we approach patient care. From virtual consenting to reducing carbon emissions, costs, and waiting times, it is a powerful tool in our clinical armamentarium. There is mounting evidence that remote diagnostic evaluation and decision-making have reached an acceptable level of accuracy and can safely be adopted in orthopaedic surgery. Furthermore, patients’ and surgeons’ satisfaction with virtual appointments are comparable to in-person consultations. Challenges to the widespread use of telehealth should, however, be acknowledged and include the cost of installation, training, maintenance, and accessibility. It is also vital that clinicians are conscious of the medicolegal and ethical considerations surrounding the medium and adhere strictly to the relevant data protection legislation and storage framework. It remains to be seen how organizations harness the full spectrum of the technology to facilitate effective patient care. Cite this article:
Blood transfusion and postoperative anaemia are complications of total knee arthroplasty (TKA) that are associated with substantial healthcare costs, morbidity, and mortality. There are few data from large datasets on the risk factors for these complications. We retrospectively reviewed the records of TKA patients from a single tertiary care institution from February 2016 to December 2020. There were a total of 14,901 patients in this cohort with a mean age of 67.9 years (SD 9.2), and 5,575 patients (37.4%) were male. Outcomes included perioperative blood transfusion and postoperative anaemia, defined a priori as haemoglobin level < 10 g/dl measured on the first day postoperatively. In order to establish a preoperative haemoglobin cutoff, we investigated a preoperative haemoglobin level that would limit transfusion likelihood to ≤ 1% (13 g/dl) and postoperative anaemia likelihood to 4.1%. Risk factors were assessed through multivariable Poisson regression modelling with robust error variance.Aims
Methods
The purpose of this study was to determine the association between prior sleeve gastrectomy in patients undergoing primary total hip and knee arthroplasty, and 90-day complications, incidence of revision arthroplasty, and patient-reported outcome scores at final follow-up. This is a retrospective, single-centre analysis. Patients undergoing primary hip or knee arthroplasty with a prior sleeve gastrectomy were eligible for inclusion (n = 80 patients). A morbidly obese control group was established from the same institutional registry using a 1:2 match, for cases:controls with arthroplasty based on propensity score using age, sex, pre-sleeve gastrectomy BMI, Current Procedural Terminology code to identify anatomical location, and presurgical haemoglobin A1C. Outcomes included 90-day complications, incidence of revision arthroplasty, and patient-reported outcome scores at final follow-up. Multivariable logistic regressions evaluated associations of underlying preoperative demographic and treatment characteristics with outcomes.Aims
Methods
One of the aims of this work was to find criteria by which the quality of bone as a supporting tissue might be judged. This inevitably involves discussion and, if possible, assessment, of the relative importance of the inorganic and organic material of the bone. It is relatively easy to measure the mineral content, and for that reason it has always received more than its due share of attention. In the present experiment the composition of the ash of all bones was remarkably constant, with a Ca/P ratio of 2. Furthermore, X-ray crystallography showed that the structure of the inorganic material was the same in all cases. The great difficulty of measuring variations in the quality of the organic material which is, of course, protein in nature makes it impossible to say how much it influences bone strength. Since at least 40 per cent. of the bone is collagen, either a quantitative or a qualitative alteration might alter bone strength. X-ray crystallography revealed no qualitative differences in the collagen material of bones of the three groups; so that for the present it would seem safer to assume that alterations in the physical properties of the bones are due to variations in the relative proportions of organic and inorganic constituents (Dawson 1946, Bell et al. 1947). These experiments show that the three diets produce highly significant differences in the percentage of ash, in S. B. , and in E. It is possible that some variations in the percentage of ash are due to variations in the absolute collagen (weight of collagen in unit volume of bone substance); but the range of variation in the percentage of ash leaves no reasonable doubt that differences in percentage ash between the diet groups are due essentially to differences in absolute ash. Presumably the collagen contributes something to the strength of the bone; but the indications are that it plays a minor part and that the relative weakness and flexibility of rachitic bones is due to decrease in the absolute ash content. Within any one diet group, the relation between percentage ash and the other two variables, S. B. and E, is masked by other sources of variation such as those associated with the many measurements involved; and thus the correlation between percentage ash and S. B. , and also between percentage ash and E, is not significant. At first sight, the scatter diagrams (Figs. 5 and 6) appear to indicate a correlation between ash and S. B. , and between ash and E. Closer inspection shows, however, that the apparent trend is due largely to differences between the means of the diet groups, and that the points within any one group show no such obvious trend. Figure 7 shows that the position with regard to correlation between S. B. and E is very different. Here there is an obvious trend within each diet group; the amount of scatter is very much less. Calculation shows that, even when the differences between the means of diet groups is excluded, there is still a significant correlation between S. B. and E. The question of the correlation between the three variables is discussed more fully in the addendum to this paper. Although the "goodness" of a bone is usually judged by its breaking stress, the experimental findings recorded above suggest that it may be assessed equally well on the basis of elastic properties as shown by Young's modulus. Normal bones, group S in these experiments, were elastic up to 79 per cent. of their breaking stress (Table II): the poorer bones of groups R and N were, however, only a little inferior in this respect. In some cases there was no apparent deviation of the load-deflexion curve from a straight line until the bone was about to break. Such a curve was published in the first paper of this series (Bell, Cuthbertson and Orr 1941), but in the light of further experience this curve is scarcely typical. The terminal falling over of the curve is illustrated in Figure 4 and is much more marked in the bones of group R. While stress at the upper limit of elasticity varies over a wide range in the three groups (Table II and Fig. 4), the strain at this point is remarkably constant at about 1·5 per cent. This same percentage displacement must occur between the molecules of the bone material at the elastic limitâand it may be that, up to this amount of molecular displacement, the deformation is reversible; but that beyond it, plastic changes occur. We have no evidence as to whether the limiting displacement concerns mineral or protein constituents of the bone, or both. We have already commented on the remarkable strength of bone material (Bell et al., 1941). The breaking stress of normal rat bone is about the same as that of cast
This report details seven patients who had an arthropathy at presentation of their haemochromatosis. The spectrum ranged from arthralgia and normal radiographs to classic polyarthritis and the typical radiological triad of joint-space narrowing, sclerosis and cysts. Some atypical presentations are highlighted. An early diagnosis of haemochromatosis requires clinical suspicion; support can be obtained from serum
Progressive structural scoliosis in growing rabbits has been produced. Tethering the thoracic spine into the form of an asymmetric lordosis produces a slowly progressive structural scoliosis by purely mechanical means. The addition of a contralateral release of the paraspinal muscles leads to a very progressive deformity with early cardiorespiratory failure. This release, however, was performed with an electric soldering
1. Experiments using radio-isotope techniques show that whenever an orthopaedic appliance is inserted into the body tiny fragments of the instruments used to handle it become detached and welded on to the surface of the buried metal. 2. There is evidence that these particles of non-passive tool-metal may cause a small but continuing dissolution of the stainless metal to which they are attached, and that this dissolution, although too small to be detected as visible corrosion, may produce an adverse tissue reaction. 3. In samples of human tissue taken from sites adjacent to buried metal the greatest level of tissue reaction and the highest concentration of
The incidence of bone metastases is between 20% to 75% depending on the type of cancer. As treatment improves, the number of patients who need surgical intervention is increasing. Identifying patients with a shorter life expectancy would allow surgical intervention with more durable reconstructions to be targeted to those most likely to benefit. While previous scoring systems have focused on surgical and oncological factors, there is a need to consider comorbidities and the physiological state of the patient, as these will also affect outcome. The primary aim of this study was to create a scoring system to estimate survival time in patients with bony metastases and to determine which factors may adversely affect this. This was a retrospective study which included all patients who had presented for surgery with metastatic bone disease. The data collected included patient, surgical, and oncological variables. Univariable and multivariable analysis identified which factors were associated with a survival time of less than six months and less than one year. A model to predict survival based on these factors was developed using Cox regression.Aims
Methods
The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs). At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays.Aims
Methods
1. A total of 564 metal components from 109 patients have been examined. 2. Corrosion was detected on 228 components. 3. Most implants were removed for reasons other than corrosion. 4. In at least twelve cases corrosion was the reason for removal of the implant. 5. No corrosion of cobalt-chromium-molybdenum implants has been detected by the methods described in this paper. 6. Corrosion of ferrous alloy implants occurs in the human body. 7. The most common site for corrosion is the junction between components of implants. 8. The most corrosion-resistant type of ferrous alloy for implant uses is 18/8/Mo steel, which falls within specification En58.J of the British Standards Institute, and specification 316/317 of the American
The aim of this study was to compare ten-year longitudinal healthcare costs and revision rates for patients undergoing unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). The Humana database was used to compare 2,383 patients undergoing UKA between 2007 and 2009, who were matched 1:1 from a cohort of 63,036 patients undergoing primary TKA based on age, sex, and Elixhauser Comorbidity Index. Medical and surgical complications were tracked longitudinally for one year following surgery. Rates of revision surgery and cumulative mean healthcare costs were recorded for this period of time and compared between the cohorts.Aims
Methods
Tenosynovial giant cell tumour (TGCT) is one of the most common soft-tissue tumours of the foot and ankle and can behave in a locally aggressive manner. Tumour control can be difficult, despite the various methods of treatment available. Since treatment guidelines are lacking, the aim of this study was to review the multidisciplinary management by presenting the largest series of TGCT of the foot and ankle to date from two specialized sarcoma centres. The Oxford Tumour Registry and the Leiden University Medical Centre Sarcoma Registry were retrospectively reviewed for patients with histologically proven foot and ankle TGCT diagnosed between January 2002 and August 2019.Aims
Methods
To investigate metallosis in patients with magnetically controlled growing rods (MCGRs) and characterize the metal particle profile of the tissues surrounding the rod. This was a prospective observational study of patients with early onset scoliosis (EOS) treated with MCGRs and undergoing rod exchange who were consecutively recruited between February 2019 and January 2020. Ten patients were recruited (mean age 12 years (SD 1.3); 2 M:8 F). The configurations of the MCGR were studied to reveal the distraction mechanisms, with crucial rod parts being the distractable piston rod and the magnetically driven rotor inside the barrel of the MCGR. Metal-on-metal contact in the form of ring-like wear marks on the piston was found on the distracted portion of the piston immediately outside the barrel opening (BO) through which the piston rod distracts. Biopsies of paraspinal muscles and control tissue samples were taken over and away from the wear marks, respectively. Spectral analyses of the rod alloy and biopsies were performed to reveal the metal constituents and concentrations. Histological analyses of the biopsies were performed with haematoxylin and eosin staining.Aims
Methods
This study aimed to determine if macrophages can attach and directly affect the oxide layers of 316L stainless steel, titanium alloy (Ti6Al4V), and cobalt-chromium-molybdenum alloy (CoCrMo) by releasing components of these alloys. Murine peritoneal macrophages were cultured and placed on stainless steel, CoCrMo, and Ti6Al4V discs into a 96-well plate. Cells were activated with interferon gamma and lipopolysaccharide. Macrophages on stainless steel discs produced significantly more nitric oxide (NO) compared to their control counterparts after eight to ten days and remained elevated for the duration of the experiment.Aims
Methods
The aim of this study was to determine the impact of the severity of anaemia on postoperative complications following total hip arthroplasty (THA) and total knee arthroplasty (TKA). A retrospective cohort study was conducted using the American College of Surgeons National Quality Improvement Program (ACS-NSQIP) database. All patients who underwent primary TKA or THA between January 2012 and December 2017 were identified and stratified based upon hematocrit level. In this analysis, we defined anaemia as packed cell volume (Hct) < 36% for women and < 39% for men, and further stratified anaemia as mild anaemia (Hct 33% to 36% for women, Hct 33% to 39% for men), and moderate to severe (Hct < 33% for both men and women). Univariate and multivariate analyses were used to evaluate the incidence of multiple adverse events within 30 days of arthroplasty.Aims
Methods
Cementless primary total hip arthroplasty (THA) is associated with risks of bleeding and thromboembolism. Anticoagulants are effective as venous thromboprophylaxis, but with an increased risk of bleeding. Tranexamic acid (TXA) is an efficient antifibrinolytic agent, but the mode and timing of its administration remain controversial. This study aimed to determine whether two intravenous (IV) TXA regimens (a three-hour two-dose (short-TXA) and 11-hour four-dose (long-TXA)) were more effective than placebo in reducing perioperative real blood loss (RBL, between baseline and day 3 postoperatively) in patients undergoing THA who receive rivaroxaban as thromboprophylaxis. The secondary aim was to assess the non-inferiority of the reduction of blood loss of the short protocol A multicentre, prospective, randomized, double-blind, placebo-controlled trial was undertaken involving 229 patients undergoing primary cementless THA using a posterior approach, whose extended rivaroxaban thromboprophylaxis started on the day of surgery. There were 98 male and 131 female patients, with a mean age of 65.5 years (32 to 91). The primary outcome, perioperative RBL, was evaluated at 72 hours postoperatively. The efficacy of short- and long-TXA protocols in the reduction of perioperative RBL was compared with a placebo group.Aims
Patients and Methods
Despite declining frequency of blood transfusion and electrolyte supplementation following total joint arthroplasty, postoperative blood analyses are still routinely ordered for these patients. This study aimed to determine the rate of blood transfusion and electrolyte restoration in arthroplasty patients treated with a perioperative blood conservation protocol and to identify risk factors that would predict the need for transfusion and electrolyte supplementation. Patients undergoing primary total joint arthroplasty of the hip or knee between July 2016 and February 2017 at a single institution were included in the study. Standard preoperative and postoperative laboratory data were collected and reviewed retrospectively. A uniform blood conservation programme was implemented for all patients. Need for blood transfusion or potassium supplementation was determined through a coordinated decision by the care team. Rates of transfusion and supplementation were observed, and patient risk factors were noted.Aims
Patients and Methods
Antifibrinolytic agents, including tranexamic acid (TXA) and epsilon-aminocaproic acid (EACA), have been shown to be safe and effective for decreasing perioperative blood loss and transfusion following total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, there are few prospective studies that directly compare these agents. The purpose of this study was to compare the benefits of intraoperative intravenous TXA with EACA. A total of 235 patients (90 THA and 145 TKA) were enrolled in this prospective, randomized controlled trial at a single tertiary-care referral centre. In the THA cohort, 53.3% of the patients were female with a median age of 59.8 years (interquartile range (IQR) 53.3 to 68.1). In the TKA cohort, 63.4% of the patients were female with a median age of 65.1 years (IQR 59.4 to 69.5). Patients received either TXA (n = 119) or EACA (n = 116) in two doses intraoperatively. The primary outcome measures included change in haemoglobin level and blood volume, postoperative drainage, and rate of transfusion. Secondary outcome measures included postoperative complications, cost, and length of stay (LOS).Aims
Patients and Methods
The aim of this study was to examine the efficacy and safety
of multiple boluses of intravenous (IV) tranexamic acid (TXA) on
the hidden blood loss (HBL) and inflammatory response following
primary total hip arthroplasty (THA). A total of 150 patients were allocated randomly to receive a
single bolus of 20 mg/kg IV TXA before the incision (group A), a
single bolus followed by a second bolus of 1 g IV-TXA three hours
later (group B) or a single bolus followed by two boluses of 1 g
IV-TXA three and six hours later (group C). All patients were treated
using a standard peri-operative enhanced recovery protocol. Primary
outcomes were HBL and the level of haemoglobin (Hb) as well as the
levels of C-reactive protein (CRP) and interleukin-6 (IL-6) as markers
of inflammation. Secondary outcomes included the length of stay
in hospital and the incidence of venous thromboembolism (VTE).Aims
Patients and Methods
Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied. In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements.Aims
Patients and Methods
There are limited published data detailing the volumetric material loss from tapers of conventional metal-on-polyethylene (MoP) total hip arthroplasties (THAs). Our aim was to address this by comparing the taper wear rates measured in an explanted cohort of the widely used Exeter THA with those measured in a group of metal-on-metal (MoM) THAs. We examined an existing retrieval database to identify all Exeter V40 and Universal MoP THAs. Volumetric wear analysis of the taper surfaces was conducted using previously validated methodology. These values were compared with those obtained from a series of MoM THAs using non-parametric statistical methodology. A number of patient and device variables were accounted for using multiple regression modelling.Aims
Patients and Methods
The pre-operative level of haemoglobin is the strongest predictor
of the peri-operative requirement for blood transfusion after total
knee arthroplasty (TKA). There are, however, no studies reporting
a value that could be considered to be appropriate pre-operatively. This study aimed to identify threshold pre-operative levels of
haemoglobin that would predict the requirement for blood transfusion
in patients who undergo TKA. Analysis of receiver operator characteristic (ROC) curves of
2284 consecutive patients undergoing unilateral TKA was used to
determine gender specific thresholds predicting peri-operative transfusion
with the highest combined sensitivity and specificity (area under
ROC curve 0.79 for males; 0.78 for females).Aims
Patients and Methods
The aim of this study was to identify the most effective regimen
of multiple doses of oral tranexamic acid (TXA) in achieving maximum
reduction of blood loss in total knee arthroplasty (TKA). In this randomized controlled trial, 200 patients were randomized
to receive a single dose of 2.0 g of TXA orally two hours preoperatively
(group A), a single dose of TXA followed by 1.0 g orally three hours
postoperatively (group B), a single dose of TXA followed by 1.0 g
three and nine hours postoperatively (group C), or a single dose
of TXA followed by 1.0 g orally three, nine, and 15 hours postoperatively
(group D). All patients followed a routine enhanced-recovery protocol.
The primary outcome measure was the total blood loss. Secondary
outcome measures were hidden blood loss (HBL), reduction in the
level of haemoglobin, the rate of transfusion and adverse events.Aims
Patients and Methods
The number of arthroplasties being undertaken
is expected to grow year on year, and periprosthetic joint infections will
be an increasing socioeconomic burden. The challenge to prevent
and eradicate these infections has resulted in the emergence of
several new strategies, which are discussed in this review. Cite this article:
Recently, several synovial biomarkers have been introduced into
the algorithm for the diagnosis of a prosthetic joint infection
(PJI). Alpha defensin is a promising biomarker, with a high sensitivity
and specificity, but it is expensive. Calprotectin is a protein
that is present in the cytoplasm of neutrophils, is released upon
neutrophil activation and exhibits anti-microbial activity. Our
aim, in this study, was to determine the diagnostic potential of
synovial calprotectin in the diagnosis of a PJI. In this pilot study, we prospectively collected synovial fluid
from the hip, knee, shoulder and elbow of 19 patients with a proven
PJI and from a control group of 42 patients who underwent revision
surgery without a PJI. PJI was diagnosed according to the current diagnostic criteria
of the Musculoskeletal Infection Society. Synovial fluid was centrifuged
and the supernatant was used to measure the level of calprotectin
after applying a lateral flow immunoassay. Aims
Patients and Methods
Neuropathic changes in the foot are common with
a prevalence of approximately 1%. The diagnosis of neuropathic arthropathy
is often delayed in diabetic patients with harmful consequences
including amputation. The appropriate diagnosis and treatment can
avoid an extensive programme of treatment with significant morbidity
for the patient, high costs and delayed surgery. The pathogenesis
of a Charcot foot involves repetitive micro-trauma in a foot with impaired
sensation and neurovascular changes caused by pathological innervation
of the blood vessels. In most cases, changes are due to a combination
of both pathophysiological factors. The Charcot foot is triggered
by a combination of mechanical, vascular and biological factors
which can lead to late diagnosis and incorrect treatment and eventually
to destruction of the foot. This review aims to raise awareness of the diagnosis of the Charcot
foot (diabetic neuropathic osteoarthropathy and the differential
diagnosis, erysipelas, peripheral arterial occlusive disease) and
describe the ways in which the diagnosis may be made. The clinical
diagnostic pathways based on different classifications are presented. Cite this article:
Several aspects of the management of an orthopaedic surgical patient are not directly related to the surgical technique but are nevertheless essential for a successful outcome. Blood management is one of these. This paper considers the various strategies available for the management of blood loss in patients undergoing orthopaedic and trauma surgery.
Orthopaedic surgeons use a variety of instruments to help correct, treat, and heal bone disease. The development of these instruments mirrors the history of orthopaedic surgery. The history of bonesetting, the treatment and replacement of joints, and of those who performed these techniques, appears to originate deep in antiquity. Changing ideas within medicine and surgery over the last 200 years have shaped the discovery and evolution of orthopaedic instruments and of the bonesetters themselves. Advances have led to the use of computers as instruments in the navigational guidance of arthroplasty surgery, the use of robotics, the development of cordless drills and improvements in the design of blades to cut bone. Yet some of the old instruments remain; plaster of Paris bandages, the Thomas Splint, Liston’s bonecutter, Gigli’s saw, bone nibblers and Macewan’s osteotomes are still in use. This paper presents a historical review of bonesetters and examines how orthopaedic instruments have evolved from antiquity to the 21st century.
We used interconnected porous calcium hydroxyapatite ceramic to bridge a rabbit ulnar defect. Two weeks after inducing the defect we percutaneously injected rabbit bone marrow-derived mesenchymal stromal cells labelled with ferumoxide. The contribution of an external magnetic targeting system to attract these cells into the ceramic and their effect on subsequent bone formation were evaluated. This technique significantly facilitated the infiltration of ferumoxide-labelled cells into ceramic and significantly contributed to the enhancement of bone formation even in the chronic phase. As such, it is potentially of clinical use to treat fractures, bone defects, delayed union and nonunion.
Total knee arthroplasty (TKA) is a major orthopaedic
intervention. The length of a patient's stay has been progressively
reduced with the introduction of enhanced recovery protocols: day-case
surgery has become the ultimate challenge. This narrative review shows the potential limitations of day-case
TKA. These constraints may be social, linked to patient’s comorbidities,
or due to surgery-related adverse events (e.g. pain, post-operative
nausea and vomiting, etc.). Using patient stratification, tailored surgical techniques and
multimodal opioid-sparing analgesia, day-case TKA might be achievable
in a limited group of patients. The younger, male patient without
comorbidities and with an excellent social network around him might
be a candidate. Demographic changes, effective recovery programmes and less invasive
surgical techniques such as unicondylar knee arthroplasty, may increase
the size of the group of potential day-case patients. The cost reduction achieved by day-case TKA needs to be balanced
against any increase in morbidity and mortality and the cost of
advanced follow-up at a distance with new technology. These factors
need to be evaluated before adopting this ultimate ‘fast-track’
approach. Cite this article:
In this study of 41 patients, we used proteomic, Western blot and immunohistochemical analyses to show that several reactive oxygen species scavenging enzymes are expressed differentially in patients with primary osteoarthritis and those with non-loosening and aseptic loosening after total hip replacement (THR). The patients were grouped as A (n = 16, primary THR), B (n = 10, fixed THR but requiring revision for polyethylene wear) and C (n = 15, requiring revision due to aseptic loosening) to verify the involvement of the identified targets in aseptic loosening. When compared with Groups A and B, Group C patients exhibited significant up-regulation of transthyretin and superoxide dismutase 3, but down-regulation of glutathione peroxidase 2 in their hip synovial fluids. Also, higher levels of superoxide dismutase 2 and peroxiredoxin 2, but not superoxide dismutase 1, catalase and glutathione perioxidase 1, were consistently detected in the hip capsules of Group C patients. We propose that dysregulated reactive oxygen species-related enzymes may play an important role in the pathogenesis and progression of aseptic loosening after THR.
In this retrospective observational cohort study,
we describe 17 patients out of 1775 treated for various fractures who
developed mycobacterium tuberculosis (MTB) infection after surgery.
The cohort comprised 15 men and two women with a mean age of 40
years (24 to 70). A total of ten fractures were open and seven were
closed. Of these, seven patients underwent intramedullary nailing
of a fracture of the long bone, seven had fractures fixed with plates,
two with Kirschner-wires and screws, and one had a hemiarthroplasty
of the hip with an Austin Moore prosthesis. All patients were followed-up
for two years. In all patients, the infection resolved, and in 14
the fractures united. Nonunion was seen in two patients one of whom
underwent two-stage total hip arthroplasty (THA) and the other patient
was treated using excision arthoplasty. Another patient was treated
using two-stage THA. With only sporadic case reports in the literature,
MTB infection is rarely clinically suspected, even in underdeveloped
and developing countries, where pulmonary and other forms of TB
are endemic. In developed countries there is also an increased incidence
among immunocompromised patients. In this paper we discuss the pathogenesis
and incidence of MTB infection after surgical management of fractures
and suggest protocols for early diagnosis and management. Cite this article:
Haemophilia is an x-linked inherited bleeding disorder which can cause severe arthropathy. We have reviewed the results of 70 primary total knee replacements (TKR) performed in 57 haemophilic patients between 1983 and 2007. The functional results were assessed using the Hospital for Special Surgery (HSS) knee scoring system and Kaplan-Meier survivorship analysis. Six patients died. HSS scores were available for 60 TKRs at a mean follow-up of 9.2 years (2 to 23); 57 (95%) had good or excellent results. Deep infection was recorded in one patient. Kaplan-Meier analysis using infection and aseptic loosening as endpoints showed the survival rate at 20 years to be 94.0%. A reduction in infection, spontaneous haemarthrosis and improvement in the quality of life were noted to justify surgery in our series of patients with a mean age of 43 (25 to 70). We have found that using the latest techniques of continuous infusion of clotting Factor have significantly helped to reduce the complication rates and have achieved results which match those of the non-haemophilic population undergoing TKR.
The long-term effects of metal-on-metal arthroplasty are currently under scrutiny because of the potential biological effects of metal wear debris. This review summarises data describing the release, dissemination, uptake, biological activity, and potential toxicity of metal wear debris released from alloys currently used in modern orthopaedics. The introduction of risk assessment for the evaluation of metal alloys and their use in arthroplasty patients is discussed and this should include potential harmful effects on immunity, reproduction, the kidney, developmental toxicity, the nervous system and carcinogenesis.
Previous research has shown an increase in chromosomal aberrations in patients with worn implants. The type of aberration depended on the type of metal alloy in the prosthesis. We have investigated the metal-specific difference in the level of DNA damage (DNA stand breaks and alkali labile sites) induced by culturing human fibroblasts in synovial fluid retrieved at revision arthroplasty. All six samples from revision cobalt-chromium metal-on-metal and four of six samples from cobalt-chromium metal-on-polyethylene prostheses caused DNA damage. By contrast, none of six samples from revision stainless-steel metal-on-polyethylene prostheses caused significant damage. Samples of cobalt-chromium alloy left to corrode in phosphate-buffered saline also caused DNA damage and this depended on a synergistic effect between the cobalt and chromium ions. Our results further emphasise that epidemiological studies of orthopaedic implants should take account of the type of metal alloy used.
We hypothesised there was no clinical value in
using an autologous blood transfusion (ABT) drain in either primary total
hip (THR) or total knee replacement (TKR) in terms of limiting allogeneic
blood transfusions when a modern restrictive blood management regime
was followed. A total of 575 patients (65.2% men), with a mean age
of 68.9 years (36 to 94) were randomised in this three-arm study
to no drainage (group A), or to wound drainage with an ABT drain
for either six hours (group B) or 24 hours (group C). The primary
outcome was the number of patients receiving allogeneic blood transfusion.
Secondary outcomes were post-operative haemoglobin (Hb) levels,
length of hospital stay and adverse events. This study identified only 41 transfused patients, with no significant
difference in distribution between the three groups (p = 0.857).
The mean pre-operative haemoglobin (Hb) value in the transfused
group was 12.8 g/dL (9.8 to 15.5) Cite this article:
Blood loss during total knee replacement (TKR)
remains a significant concern. In this study, 114 patients underwent TKR,
and were divided into two groups based on whether they received
a new generation fibrin sealant intra-operatively, or a local infiltration
containing adrenaline. Groups were then compared for mean calculated
total blood volume (TBV) loss, transfusion rates, and knee range
of movement. Mean TBV loss was similar between groups: fibrin sealant
mean was 705 ml (281 to 1744), local adrenaline mean was 712 ml
(261 to 2308) (p = 0.929). Overall, significantly fewer units of
blood were transfused in the fibrin sealant group (seven units)
compared with the local adrenaline group (15 units) (p = 0.0479).
Per patient transfused, significantly fewer units of blood were transfused
in the fibrin sealant group (1.0 units) compared with the local
adrenaline group (1.67 units) (p = 0.027), suggesting that the fibrin
sealant may reduce the need for multiple unit transfusions. Knee
range of movement was similar between groups. From our results,
it appears that application of this newer fibrin sealant results
in blood loss and transfusion rates that are low and similar to
previously applied fibrin sealants. Cite this article:
In our department we use an enhanced recovery
protocol for joint replacement of the lower limb. This incorporates the
use of intravenous tranexamic acid (IVTA; 15 mg/kg) at the induction
of anaesthesia. Recently there was a national shortage of IVTA for
18 weeks; during this period all patients received an oral preparation
of tranexamic acid (OTA; 25 mg/kg). This retrospective study compares
the safety (surgical and medical complications) and efficacy (reduction
of transfusion requirements) of OTA and IVTA. During the study period
a total of 2698 patients received IVTA and 302 received OTA. After
adjusting for a range of patient and surgical factors, the odds
ratio (OR) of receiving a blood transfusion was significantly higher
with IVTA than with OTA (OR 0.48 (95% confidence interval 0.26 to
0.89), p = 0.019), whereas the safety profile was similar, based
on length of stay, rate of readmission, return to theatre, deep
infection, stroke, gastrointestinal bleeding, myocardial infarction,
pneumonia, deep-vein thrombosis and pulmonary embolism. The financial
benefit of OTA is £2.04 for a 70 kg patient; this is amplified when
the cost saving associated with significantly fewer blood transfusions
is considered. Although the number of patients in the study is modest, this
work supports the use of OTA, and we recommend that a randomised
trial be undertaken to compare the different methods of administering
tranexamic acid. Cite this article:
The outcome after total hip replacement has improved
with the development of surgical techniques, better pain management
and the introduction of enhanced recovery pathways. These pathways
require a multidisciplinary team to manage pre-operative education,
multimodal pain control and accelerated rehabilitation. The current economic
climate and restricted budgets favour brief hospitalisation while
minimising costs. This has put considerable pressure on hospitals
to combine excellent results, early functional recovery and shorter
admissions. In this review we present an evidence-based summary of some common
interventions and methods, including pre-operative patient education,
pre-emptive analgesia, local infiltration analgesia, pre-operative
nutrition, the use of pulsed electromagnetic fields, peri-operative
rehabilitation, wound dressings, different surgical techniques, minimally
invasive surgery and fast-track joint replacement units. Cite this article:
We studied the effect of vitamin C on fracture healing in the elderly. A total of 80 elderly Osteogenic Disorder Shionogi rats were divided into four groups with different rates of vitamin C intake. A closed bilateral fracture was made in the middle third of the femur of each rat. Five weeks after fracture the femora were analysed by mechanical and histological testing. The groups with the lower vitamin C intake demonstrated a lower mechanical resistance of the healing callus and a lower histological grade. The vitamin C levels in blood during healing correlated with the torque resistance of the callus formed (
This paper reviews the current literature concerning the main clinical factors which can impair the healing of fractures and makes recommendations on avoiding or minimising these in order to optimise the outcome for patients. The clinical implications are described.
Following the recall of modular neck hip stems
in July 2012, research into femoral modularity will intensify over
the next few years. This review aims to provide surgeons with an
up-to-date summary of the clinically relevant evidence. The development
of femoral modularity, and a classification system, is described.
The theoretical rationale for modularity is summarised and the clinical
outcomes are explored. The review also examines the clinically relevant problems
reported following the use of femoral stems with a modular neck. Joint replacement registries in the United Kingdom and Australia
have provided data on the failure rates of modular devices but cannot
identify the mechanism of failure. This information is needed to
determine whether modular neck femoral stems will be used in the
future, and how we should monitor patients who already have them implanted. Cite this article:
Strains applied to bone can stimulate its development and adaptation. High strains and rates of strain are thought to be osteogenic, but the specific dose response relationship is not known.
Giant cell tumours (GCT) of the synovium and
tendon sheath can be classified into two forms: localised (giant
cell tumour of the tendon sheath, or nodular tenosynovitis) and
diffuse (diffuse-type giant cell tumour or pigmented villonodular
synovitis). The former principally affects the small joints. It
presents as a solitary slow-growing tumour with a characteristic
appearance on MRI and is treated by surgical excision. There is
a significant risk of multiple recurrences with aggressive diffuse
disease. A multidisciplinary approach with dedicated MRI, histological assessment
and planned surgery with either adjuvant radiotherapy or systemic
targeted therapy is required to improve outcomes in recurrent and
refractory diffuse-type GCT. Although arthroscopic synovectomy through several portals has
been advocated as an alternative to arthrotomy, there is a significant
risk of inadequate excision and recurrence, particularly in the
posterior compartment of the knee. For local disease partial arthroscopic
synovectomy may be sufficient, at the risk of recurrence. For both
local and diffuse intra-articular disease open surgery is advised
for recurrent disease. Marginal excision with focal disease will
suffice, not dissimilar to the treatment of GCT of tendon sheath.
For recurrent and extra-articular soft-tissue disease adjuvant therapy,
including intra-articular radioactive colloid or moderate-dose external
beam radiotherapy, should be considered.
For the treatment of ununited fractures, we developed
a system of delivering magnetic labelled mesenchymal stromal cells
(MSCs) using an extracorporeal magnetic device. In this study, we
transplanted ferucarbotran-labelled and luciferase-positive bone
marrow-derived MSCs into a non-healing femoral fracture rat model
in the presence of a magnetic field. The biological fate of the
transplanted MSCs was observed using luciferase-based bioluminescence
imaging and we found that the number of MSC derived photons increased
from day one to day three and thereafter decreased over time. The
magnetic cell delivery system induced the accumulation of photons at
the fracture site, while also retaining higher photon intensity
from day three to week four. Furthermore, radiological and histological
findings suggested improved callus formation and endochondral ossification.
We therefore believe that this delivery system may be a promising
option for bone regeneration.
We report a systematic review and meta-analysis
of the peer-reviewed literature focusing on metal sensitivity testing
in patients undergoing total joint replacement (TJR). Our purpose
was to assess the risk of developing metal hypersensitivity post-operatively
and its relationship with outcome and to investigate the advantages
of performing hypersensitivity testing. We undertook a comprehensive search of the citations quoted in
PubMed and EMBASE: 22 articles (comprising 3634 patients) met the
inclusion criteria. The frequency of positive tests increased after
TJR, especially in patients with implant failure or a metal-on-metal
coupling. The probability of developing a metal allergy was higher
post-operatively (odds ratio (OR) 1.52 (95% confidence interval
(CI) 1.06 to 2.31)), and the risk was further increased when failed
implants were compared with stable TJRs (OR 2.76 (95% CI 1.14 to
6.70)). Hypersensitivity testing was not able to discriminate between
stable and failed TJRs, as its predictive value was not statistically
proven. However, it is generally thought that hypersensitivity testing
should be performed in patients with a history of metal allergy
and in failed TJRs, especially with metal-on-metal implants and
when the cause of the loosening is doubtful.
We undertook a study of the anti-tumour effects of hyperthermia, delivered via magnetite cationic liposomes (MCLs), on local tumours and lung metastases in a mouse model of osteosarcoma. MCLs were injected into subcutaneous osteosarcomas (LM8) and subjected to an alternating magnetic field which induced a heating effect in MCLs. A control group of mice with tumours received MCLs but were not exposed to an AMF. A further group of mice with tumours were exposed to an AMF but had not been treated with MCLs. The distribution of MCLs and local and lung metastases was evaluated histologically. The weight and volume of local tumours and the number of lung metastases were determined. Expression of heat shock protein 70 was evaluated immunohistologically. Hyperthermia using MCLs effectively heated the targeted tumour to 45°C. The mean weight of the local tumour was significantly suppressed in the hyperthermia group (p = 0.013). The mice subjected to hyperthermia had significantly fewer lung metastases than the control mice (p = 0.005). Heat shock protein 70 was expressed in tumours treated with hyperthermia, but was not found in those tumours not exposed to hyperthermia. The results demonstrate a significant effect of hyperthermia on local tumours and reduces their potential to metastasise to the lung.
The Thomas splint is a common piece of equipment in emergency departments and orthopaedic units in hospitals worldwide. Its basic design has changed little since its first description by Hugh Owen Thomas was published in 1875. We have reviewed the origins of the Thomas splint as a means of correction of deformities of the lower limb and its evolution through both World Wars into an essential item for the management of trauma of the lower limb.
We sought to establish the incidence of joint failure secondary to adverse reaction to metal debris (ARMD) following metal-on-metal hip resurfacing in a large, three surgeon, multicentre study involving 4226 hips with a follow-up of 10 to 142 months. Three implants were studied: the Articular Surface Replacement; the Birmingham Hip Resurfacing; and the Conserve Plus. Retrieved implants underwent analysis using a co-ordinate measuring machine to determine volumetric wear. There were 58 failures associated with ARMD. The median chromium and cobalt concentrations in the failed group were significantly higher than in the control group (p <
0.001). Survival analysis showed a failure rate in the patients with Articular Surface Replacement of 9.8% at five years, compared with <
1% at five years for the Conserve Plus and 1.5% at ten years for the Birmingham Hip Resurfacing. Two ARMD patients had relatively low wear of the retrieved components. Increased wear from the metal-on-metal bearing surface was associated with an increased rate of failure secondary to ARMD. However, the extent of tissue destruction at revision surgery did not appear to be dose-related to the volumetric wear.
This prospective randomised clinical trial evaluated the effect of alternatives for allogeneic blood transfusions after total hip replacement and total knee replacement in patients with pre-operative haemoglobin levels between 10.0 g/dl and 13.0 g/dl. A total of 100 patients were randomly allocated to the Eprex (pre-operative injections of epoetin) or Bellovac groups (post-operative retransfusion of shed blood). Allogeneic blood transfusions were administered according to hospital policy. In the Eprex group, 4% of the patients (two patients) received at least one allogeneic blood transfusion. In the Bellovac group, where a mean 216 ml (0 to 700) shed blood was retransfused, 28% (14 patients) required the allogeneic transfusion (p = 0.002). When comparing Eprex with Bellovac in total hip replacement, the percentages were 7% (two of 30 patients) and 30% (nine of 30 patients) (p = 0.047) respectively, whereas in total knee replacement, the percentages were 0% (0 of 20 patients) and 25% (five of 20 patients) respectively (p = 0.042). Pre-operative epoetin injections are more effective but more costly in reducing the need for allogeneic blood transfusions in mildly anaemic patients than post-operative retransfusion of autologous blood.
The biological significance of cobalt-chromium wear particles from metal-on-metal hip replacements may be different to the effects of the constituent metal ions in solution. Bacteria may be able to discriminate between particulate and ionic forms of these metals because of a transmembrane nickel/cobalt-permease. It is not known whether wear particles are bacteriocidal. We compared the doubling time of coagulase negative staphylococcus, Doubling time halved in metal-on-metal (p = 0.003) and metal-on-polyethylene (p = 0.131) particulate debris compared with the control. Bacterial nickel/cobalt-transporters allow metal ions but not wear particles to cross bacterial membranes. This may be useful for testing the biological characteristics of different wear debris. This experiment also shows that metal-on-metal hip wear debris is not bacteriocidal.
Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clinical and radiological outcomes, metal ion levels, explant studies and lymphocyte transformation tests were performed. A total of 17 patients (3.4%) were identified (all ASR bearings) with adverse reactions to metal debris, for which revision was required. This group had significantly smaller components, significantly higher acetabular component anteversion, and significantly higher whole concentrations of blood and joint chromium and cobalt ions than asymptomatic patients did (all p <
0.001). Post-revision lymphocyte transformation tests on this group showed no reactivity to chromium or cobalt ions. Explants from these revisions had greater surface wear than retrievals for uncomplicated fractures. The absence of adverse reactions to metal debris in patients with well-positioned implants usually implies high component wear. Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement.
Bovine and human articular chondrocytes were seeded in 2% alginate constructs and cultured for up to 19 days in a rotating-wall-vessel (RWV) and under static conditions. Culture within the RWV enhanced DNA levels for bovine chondrocyte-seeded constructs when compared with static conditions but did not produce enhancement for human cells. There was a significant enhancement of glycosaminoglycans and hydroxyproline synthesis for both bovine and human chondrocytes. In all cases, histological analysis revealed enhanced Safranin-O staining in the peripheral regions of the constructs compared with the central region. There was an overall increase in staining intensity after culture within the RWV compared with static conditions. Type-II collagen was produced by both bovine and human chondrocytes in the peripheral and central regions of the constructs and the staining intensity was enhanced by culture within the RWV. A capsule of flattened cells containing type-I collagen developed around the constructs maintained under static conditions when seeded with either bovine or human chondrocytes, but not when cultured within the RWV bioreactor.