The Oxford hip and knee scores (OHS and OKS)
are validated patient-reported outcome measures used in patients undergoing
total hip replacement (THR), hip resurfacing (HR), total knee replacement
(TKR) and unicompartmental knee replacement (UKR). We analysed the
absolute
We assessed the orientation of the acetabular
component in 1070 primary total hip arthroplasties with hard-on-soft, small
diameter bearings, aiming to determine the size and site of the
target zone that optimises outcome. Outcome measures included complications,
dislocations, revisions and ΔOHS (the difference between the Oxford
Hip Scores pre-operatively and five years post-operatively). A wide
scatter of orientation was observed (2. sd. 15°). Placing
the component within Lewinnek’s zone was not associated withimproved
outcome. Of the different zone sizes tested (± 5°, ± 10° and ± 15°),
only ± 15° was associated with a decreased rate of dislocation.
The dislocation rate with acetabular components inside an inclination/anteversion
zone of 40°/15° ± 15° was four times lower than those outside. The
only zone size associated with statistically significant and clinically
important improvement in
Aims. The influence of metabolic syndrome (MetS) on the outcome after hip and knee arthroplasty is debated. We aimed to investigate the change in patient-reported outcome measure (PROM) scores after hip and knee arthroplasty, comparing patients with and without MetS. Methods. From 1 May 2017 to 30 November 2019, a prospective cohort of 2,586 patients undergoing elective unilateral hip and knee arthroplasty was established in Denmark. Data from national registries and a local database were used to determine the presence of MetS. Patients’ scores on Oxford Hip Score (OHS) or Oxford Knee Score (OKS), EuroQol five-dimension five-level questionnaire (EQ-5D-5L), University of California, Los Angeles (UCLA) Activity Scale, and Forgotten Joint Score (FJS) at baseline, three, 12, and 24 months after surgery were collected. Primary outcome was the difference between groups from baseline to 12 months in
Aims. Although periacetabular osteotomies are widely used for the treatment of symptomatic dysplastic hips, long-term surgical outcomes and patient-reported outcome measures (PROMs) are still unclear. Accordingly, we assessed hip survival and PROMs at 20 years after transpositional osteotomy of the acetabulum (TOA). Methods. A total of 172 hips in 159 patients who underwent TOA were followed up at a mean of 21.02 years (16.6 to 24.6) postoperatively. Kaplan-Meier analysis was used to assess survivorship with an endpoint of total hip arthroplasty (THA). PROMs included the visual analogue scale (VAS) Satisfaction, VAS Pain, Oxford Hip Score (OHS), and Forgotten Joint Score-12 (FJS-12). Thresholds for favourable outcomes for
Aims. Access to joint replacement is being restricted for patients with comorbidities in a number of high-income countries. However, there is little evidence on the impact of comorbidities on outcomes. The purpose of this study was to determine the safety and effectiveness of hip and knee arthroplasty in patients with and without comorbidities. Methods. In total, 312,079 hip arthroplasty and 328,753 knee arthroplasty patients were included. A total of 11 common comorbidities were identified in administrative hospital records. Safety risks were measured by assessing length of hospital stay (LOS) and 30-day emergency readmissions and mortality. Effectiveness outcomes were changes in Oxford Hip or Knee Scores (OHS/OKS) (scale from 0 (worst) to 48 (best)) and in health-related quality of life (EQ-5D) (scale from 0 (death) to 1 (full health)) from immediately before, to six months after, surgery. Regression analysis was used to estimate adjusted mean differences (LOS, change in
Aims. To determine the trajectories of patient reported pain and functional disability over five years following total hip arthroplasty (THA) or total knee arthroplasty (TKA). Methods. A prospective, longitudinal cohort sub-study within the National Joint Registry (NJR) was undertaken. In all, 20,089 patients who underwent primary THA and 22,489 who underwent primary TKA between 2009 and 2010 were sent Oxford Hip Score (OHS) and Oxford Knee Score (OKS) questionnaires at six months, and one, three, and five years postoperatively.
Aims. Hip fractures in patients < 60 years old currently account for only 3% to 4% of all hip fractures in England, but this proportion is increasing. Little is known about the longer-term patient-reported outcomes in this potentially more active population. The primary aim is to examine patient-reported outcomes following isolated hip fracture in patients aged < 60 years. The secondary aim is to determine an association between outcomes and different types of fracture pattern and/or treatment implants. Methods. All hip fracture patients aged 18 to 60 years admitted to a single centre over a 15-year period were used to identify the study group. Fracture pattern (undisplaced intracapsular, displaced intracapsular, and extracapsular) and type of operation (multiple cannulated hip screws, angular stable fixation, hemiarthroplasty, and total hip replacement) were recorded. The primary outcome measures were the Oxford Hip Score (OHS), the EuroQol five-dimension questionnaire (EQ-5D-3L), and EQ-visual analogue scale (VAS) scores. Preinjury scores were recorded by patient recall and postinjury scores were collected at a mean of 57 months (9 to 118) postinjury. Ethics approval was obtained prior to study commencement. Results. A total of 72 patients were included. There was a significant difference in pre- and post-injury
Aims. The purpose of this study was to evaluate the mid-term outcomes of autologous matrix-induced chondrogenesis (AMIC) for the treatment of larger cartilage lesions and deformity correction in hips suffering from symptomatic femoroacetabular impingement (FAI). Methods. This single-centre study focused on a cohort of 24 patients with cam- or pincer-type FAI, full-thickness femoral or acetabular chondral lesions, or osteochondral lesions ≥ 2 cm. 2. , who underwent surgical hip dislocation for FAI correction in combination with AMIC between March 2009 and February 2016. Baseline data were retrospectively obtained from patient files. Mid-term outcomes were prospectively collected at a follow-up in 2020: cartilage repair tissue quality was evaluated by MRI using the Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) score. Patient-reported outcome measures (PROMs) included the Oxford Hip Score (OHS) and Core Outcome Measure Index (COMI). Clinical examination included range of motion, impingement tests, and pain. Results. A total of 12 hips from 11 patients were included (ten males, one female, mean age 26.8 years (SD 5.0), mean follow-up 6.2 years (SD 5.2 months)). The mean postoperative MOCART score was 66.3 (SD 16.3). None of the patients required conversion to total hip arthroplasty. Two patients had anterior impingement. External hip rotation was moderately limited in four patients. There was a correlation between MOCART and follow-up time (r. s. = -0.61; p = 0.035), but not with initial cartilage damage, age, BMI, or imaging time delay before surgery. PROMs improved significantly:
Aims. In metal-on-polyethylene (MoP) total hip arthroplasty (THA), large metal femoral heads have been used to increase stability and reduce the risk of dislocation. The increased size of the femoral head can, however, lead to increased taper corrosion, with the release of metal ions and adverse reactions. The aim of this study was to investigate the relationship between the size of the femoral head and the levels of metal ions in the blood in these patients. Methods. A total of 96 patients were enrolled at two centres and randomized to undergo MoP THA using either a 32 mm metal head or a femoral head of between 36 mm and 44 mm in size, being the largest possible to fit the thinnest available polyethylene insert. The levels of metal ions and patient-reported outcome measures (Oxford Hip Score, University of California, Los Angeles Activity Scale) were recorded at two and five years postoperatively. Results. At five years, the median levels of chromium, cobalt, and titanium were 0.5 μg/l (interquartile range (IQR) 0.50 to 0.62), 0.24 μg/l (IQR 0.18 to 0.30), and 1.16 μg/l (IQR 1.0 to 1.68) for the 32 mm group, and 0.5 μg/l (IQR 0.5 to 0.54), 0.23 μg/l (IQR 0.17 to 0.39), and 1.30 μg/l (IQR 1 to 2.05) for the 36 mm to 44 mm group, with no significant difference between the groups (p = 0.825, p = 1.000, p = 0.558). There were increased levels of metal ions at two years postoperatively in seven patients in the 32 mm group, compared with four in the 36 mm to 44 mm group, and at five years postoperatively in six patients in the 32 mm group, compared with seven in the 36 mm to 44 mm group. There was no significant difference in either the
Aims. The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon’s consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years. Methods. The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken. Results. Overall implant survival was 83.50% (95% confidence interval (CI) 0.79 to 0.90) at 25 years, and the number at risk was 79. Survival in male patients at 25 years was 89.5% (95% CI 0.83 to 0.96) compared to 66.9% for female patients (95% CI 0.51 to 0.83). Ten additional failures occurred in the period of ten to 25 years. These involved an adverse reaction to metal debris in four patients, a periprosthetic femoral neck fracture affecting five patients, and aseptic loosening in one patient. The median chromium levels were 49.50 nmol/l (interquartile range (IQR) 34 to 70), and the median cobalt serum levels were 42 nmol/l (IQR 24.50 to 71.25). The median
Aims. There are limited long-term studies reporting on outcomes of the Zimmer Modular Revision (ZMR) stem, and concerns remain regarding failure. Our primary aim was to determine long-term survival free from all-cause revision and stem-related failure for this modular revision stem in revision total hip arthroplasty (THA). Secondary aims included evaluating radiological and functional outcomes. Methods. We retrospectively identified all patients in our institutional database who underwent revision THA using the ZMR system from January 2000 to December 2007. We included 106 patients (108 hips) with a mean follow-up of 14.5 years (2.3 to 22.3). Mean patient age was 69.2 years (37.0 to 89.4), and 51.9% were female (n = 55). Indications for index revision included aseptic loosening (73.1%), infection (16.7%), fracture (9.3%), and stem fracture (0.9%). Kaplan-Meier analysis was used to determine the all-cause and stem-related failure revision-free survival. At most recent follow-up, Oxford Hip Scores (OHS) were collected, and radiological stem stability was determined using the Engh classification. Results. A total of 17 hips (15.7%) underwent re-revision of any component. Indications for re-revision were stem failure (35.3%; n = 6), infection (29.4%; n = 5), instability (29.4%; n = 5), and acetabular aseptic loosening (5.9%; n = 1). The five- and 15-year all-cause survival was 89.7% (95% confidence interval (CI) 86.7 to 92.7) and 83.3% (95% CI 79.6 to 87.0), respectively. There were six re-revisions (5.6%) for stem failure; five for stem fracture and one for aseptic loosening. The five- and 15-year survival free from stem-related failure was 97.2% (95% CI 95.6 to 98.8) and 94.0% (95% CI 91.6 to 96.4), respectively. At final follow-up, the mean
Aims. The primary aim was to assess change in health-related quality of life (HRQoL) of patients as they waited from six to 12 months for a total hip (THA) or total or partial knee arthroplasty (KA). Secondary aims were to assess change in joint-specific function, mental health, quality of sleep, number living in a state worse than death (WTD), wellbeing, and patient satisfaction with their healthcare. Methods. This prospective study included 142 patients awaiting a THA (mean age 66.7 years (SD 11.4); 71 female) and 214 patients awaiting KA (mean age 69.7 years (SD 8.7); 117 female). Patients completed questionnaires (EuroQol five-dimension health questionnaire (EQ-5D), Oxford Hip and Knee Scores (OHS/OKS), Pittsburgh Sleep Quality Index (PSQI), Hospital Anxiety and Depression Score (HADS), University of California, Los Angeles Activity Scale, wellbeing assessment, and satisfaction with their healthcare) at six and 12 months while awaiting surgery. Results. There was a clinical and statistically significant deterioration in the EQ-5D while awaiting THA (mean change 0.071 (95% confidence interval (CI) 0.018 to 0.124); p = 0.009) and KA (mean change 0.069 (95% CI 0.032 to 0.106); p < 0.001). For patients awaiting a THA, there were deteriorations in
Aims. To assess how the cost-effectiveness of total hip arthroplasty (THA) and total knee arthroplasty (TKA) varies with age, sex, and preoperative Oxford Hip or Knee Score (OHS/OKS); and to identify the patient groups for whom THA/TKA is cost-effective. Methods. We conducted a cost-effectiveness analysis using a Markov model from a United Kingdom NHS perspective, informed by published analyses of patient-level data. We assessed the cost-effectiveness of THA and TKA in adults with hip or knee osteoarthritis compared with having no arthroplasty surgery during the ten-year time horizon. Results. THA and TKA cost < £7,000 per quality-adjusted life-year (QALY) gained at all preoperative scores below the absolute referral thresholds calculated previously (40 for
Aims. It is not known whether preservation of the capsule of the hip positively affects patient-reported outcome measures (PROMs) in total hip arthroplasty using the direct anterior approach (DAA-THA). A recent randomized controlled trial found no clinically significant difference at one year postoperatively. This study aimed to determine whether preservation of the anterolateral capsule and anatomical closure improve the outcome and revision rate, when compared with resection of the anterolateral capsule, at two years postoperatively. Methods. Two consecutive groups of patients whose operations were performed by the senior author were compared. The anterolateral capsule was resected in the first group of 430 patients between January 2012 and December 2014, and preserved and anatomically closed in the second group of 450 patients between July 2015 and December 2017. There were no other technical changes between the two groups. Patient characteristics, the Charlson Comorbidity Index (CCI), and surgical data were collected from our database. PROM questionnaires, consisting of the Oxford Hip Score (OHS) and Core Outcome Measures Index (COMI-Hip), were collected two years postoperatively. Data were analyzed with generalized multiple regression analysis. Results. The characteristics, CCI, operating time, and length of stay were similar in both groups. There was significantly less blood loss in the capsular preservation group (p = 0.037). The revision rate (n = 3, (0.6%) in the resected group, and 1 (0.2%) in the preserved group) did not differ significantly (p = 0.295). Once adjusted for demographic and surgical factors, the preserved group had significantly worse PROMs: + 0.24 COMI-Hip (p < 0.001) and -1.6
Aims. The aim of this study was to compare the mid-term patient-reported outcome, bone remodelling, and migration of a short stem (Collum Femoris Preserving; CFP) with a conventional uncemented stem (Corail). Methods. Of 81 patients who were initially enrolled, 71 were available at five years’ follow-up. The outcomes at two years have previously been reported. The primary outcome measure was the clinical result assessed using the Oxford Hip Score (OHS). Secondary outcomes were the migration of the stem, measured using radiostereometric analysis (RSA), change of bone mineral density (BMD) around the stem, the development of radiolucent lines, and additional patient-reported outcome measures (PROMs). Results. There were no statistically significant differences between the groups regarding PROMs (median
Aims. The aims of this study were to determine the success of a reconstruction algorithm used in major acetabular bone loss, and to further define the indications for custom-made implants in major acetabular bone loss. Methods. We reviewed a consecutive series of Paprosky type III acetabular defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical acetabular component. IIIB defects were planned to receive either a hemispherical acetabular component plus augments, a cup-cage reconstruction, or a custom-made implant. We used national digital health records and registry reports to identify any reoperation or re-revision procedure and Oxford Hip Score (OHS) for patient-reported outcomes. Implant survival was determined via Kaplan-Meier analysis. Results. A total of 105 procedures were carried out in 100 patients (five bilateral) with a mean age of 73 years (42 to 94). In the IIIA defects treated, 72.0% (36 of 50) required a porous metal augment; the remaining 14 patients were treated with a hemispherical acetabular component alone. In the IIIB defects, 63.6% (35 of 55) underwent reconstruction as planned with 20 patients who actually required a hemispherical acetabular component alone. At mean follow-up of 7.6 years, survival was 94.3% (95% confidence interval 97.4 to 88.1) for all-cause revision and the overall dislocation rate was 3.8% (4 of 105). There was no difference observed in survival between type IIIA and type IIIB defects and whether a hemispherical implant alone was used for the reconstruction or not. The mean gain in
Aims. Routinely collected patient-reported outcome measures (PROMs) have been useful to quantify and quality-assess provision of total hip arthroplasty (THA) and total knee arthroplasty (TKA) in the UK for the past decade. This study aimed to explore whether the outcome following primary THA and TKA had improved over the past seven years. Methods. Secondary data analysis of 277,430 primary THAs and 308,007 primary TKAs from the NHS PROMs programme was undertaken. Outcome measures were: postoperative Oxford Hip/Knee Score (OHS/OKS); proportion of patients achieving a clinically important improvement in joint function (responders); quality of life; patient satisfaction; perceived success; and complication rates. Outcome measures were compared based on year of surgery using multiple linear and logistic regression models. Results. For primary THA, multiple linear regression modelling found that more recent year of surgery was associated with higher postoperative
Aims. The EuroQol five-dimension (EQ-5D) questionnaire is a widely used multiattribute general health questionnaire where an EQ-5D < 0 defines a state ‘worse than death’ (WTD). The aim of this study was to determine the proportion of patients awaiting total hip arthroplasty (THA) or total knee arthroplasty (TKA) in a health state WTD and to identify associations with this state. Secondary aims were to examine the effect of WTD status on one-year outcomes. Patients and Methods. A cross-sectional analysis of 2073 patients undergoing 2073 THAs (mean age 67.4 years (. sd. 11.6; 14 to 95); mean body mass index (BMI) 28.5 kg/m. 2. (. sd. 5.7; 15 to 72); 1253 female (60%)) and 2168 patients undergoing 2168 TKAs (mean age 69.3 years (. sd. 9.6; 22 to 91); BMI 30.8 kg/m. 2. (. sd. 5.8; 13 to 57); 1244 female (57%)) were recorded. Univariate analysis was used to identify variables associated with an EQ-5D score < 0: age, BMI, sex, deprivation quintile, comorbidities, and joint-specific function measured using the Oxford Hip Score (OHS) or Oxford Knee Score (OKS). Multivariate logistic regression was performed. EQ-5D and
Aims. The aim of this prospective cohort study was to evaluate the early migration of the TriFit cementless proximally coated tapered femoral stem using radiostereometric analysis (RSA). Methods. A total of 21 patients (eight men and 13 women) undergoing primary total hip arthroplasty (THA) for osteoarthritis of the hip were recruited in this study and followed up for two years. Two patients were lost to follow-up. All patients received a TriFit stem and Trinity Cup with a vitamin E-infused highly cross-linked ultra-high molecular weight polyethylene liner. Radiographs for RSA were taken postoperatively and then at three, 12, and 24 months. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and adverse events were reported. Results. At two years, the mean subsidence of the head and tip for the TriFit stem was 0.38 mm (SD 0.32) and 0.52 mm (SD 0.36), respectively. The total migration of the head and tip was 0.55 mm (SD 0.32) and 0.71 mm (SD 0.38), respectively. There were no statistically significant differences between the three to 12 months' migration (p = 0.105) and 12 to 24 months' migration (p = 0.694). The
Aims. The purpose of this study was to compare the clinical, radiological, and patient-reported outcome measures (PROMs) in the first 100 consecutive patients undergoing total hip arthroplasty (THA) via a direct superior approach (DSA) with a matched group of patients undergoing THA by the same surgeon, using a posterolateral approach (PLA). Methods. This was a retrospective single surgeon study comparing the first 100 consecutive DSA THA patients with a matched group of patients using a standard PLA. Case notes were examined for patient demographics, length of hospital stay, operating time, intra- and postoperative complications, pain score, satisfaction score, and Oxford Hip Score (OHS). Leg length discrepancy and component positioning were measured from postoperative plain radiographs. Results. The DSA patients had a shorter length of hospital stay (mean 2.09 days (SD 1.20) DSA vs 2.74 days (SD 1.17) PLA; p < 0.001) and shorter time to discharge from the inpatient physiotherapy teams (mean 1.44 days (SD 1.17) DSA vs 1.93 days (SD 0.96) PLA; p < 0.001). There were no differences in operating time (p = 0.505), pain levels up to postoperative day 1 (p = 0.106 to p =0.242),
Aims. To calculate how the likelihood of obtaining measurable benefit from hip or knee arthroplasty varies with preoperative patient-reported scores. Methods. Existing UK data from 222,933 knee and 209,760 hip arthroplasty patients were used to model an individual’s probability of gaining meaningful improvement after surgery based on their preoperative Oxford Knee or Hip Score (OKS/OHS). A clinically meaningful improvement after arthroplasty was defined as ≥ 8 point improvement in
Aims. We compared the clinical outcomes of curved intertrochanteric varus osteotomy (CVO) with bone impaction grafting (BIG) with CVO alone for the treatment of osteonecrosis of the femoral head (ONFH). Methods. This retrospective comparative study included 81 patients with ONFH; 37 patients (40 hips) underwent CVO with BIG (BIG group) and 44 patients (47 hips) underwent CVO alone (CVO group). Patients in the BIG group were followed-up for a mean of 12.2 years (10.0 to 16.5). Patients in the CVO group were followed-up for a mean of 14.5 years (10.0 to 21.0). Assessment parameters included the Harris Hip Score (HHS), Oxford Hip Score (OHS), Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire (JHEQ), complication rates, and survival rates, with conversion to total hip arthroplasty (THA) and radiological failure as the endpoints. Results. There were no significant differences in preoperative and postoperative HHS or postoperative
Aims. The aim of this study was to compare early functional and health
related quality of life outcomes (HRQoL) in patients who have undergone
total hip arthroplasty (THA) using a bone conserving short stem
femoral component and those in whom a conventional length uncemented
component was used. Outcome was assessed using a validated performance
based outcome instrument as well as patient reported outcome measures
(PROMs). Patients and Methods. We prospectively analysed 33 patients whose THA involved a contemporary
proximally porous coated tapered short stem femoral component and
53 patients with a standard conventional femoral component, at a
minimum follow-up of two years. The mean follow-up was 31.4 months
(24 to 39). Patients with poor proximal femoral bone quality were
excluded. The mean age of the patients was 66.6 years (59 to 77)
and the mean body mass index was 30.2 kg/m. 2. (24.1 to
41.0). Outcome was assessed using the Oxford Hip Score (OHS) and
the University College Hospital (UCH) hip score which is a validated
performance based instrument. HRQoL was assessed using the EuroQol
5D (EQ-5D). Results. There were no major peri-operative complications. There was no
difference in the mean post-operative
Aims. To evaluate the outcomes of cemented total hip arthroplasty (THA)
following a fracture of the acetabulum, with evaluation of risk
factors and comparison with a patient group with no history of fracture. . Patients and Methods. Between 1992 and 2016, 49 patients (33 male) with mean age of
57 years (25 to 87) underwent cemented THA at a mean of 6.5 years
(0.1 to 25) following acetabular fracture. A total of 38 had undergone
surgical fixation and 11 had been treated non-operatively; 13 patients
died at a mean of 10.2 years after THA (0.6 to 19). Patients were
assessed pre-operatively, at one year and at final follow-up (mean
9.1 years, 0.5 to 23) using the Oxford Hip Score (OHS). Implant
survivorship was assessed. An age and gender-matched cohort of THAs
performed for non-traumatic osteoarthritis (OA) or avascular necrosis
(AVN) (n = 98) were used to compare complications and patient-reported outcome
measures (PROMs). Results. The mean time from fracture to THA was significantly shorter
for patients with AVN
(2.2 years) or protrusio (2.2 years) than those with post-traumatic
OA (9.4 years) or infection (8.0 years) (p = 0.03). Nine contained
and four uncontained defects were managed with autograft (n = 11),
bulk allograft (n = 1), or trabecular metal augment (n = 1). Initial
fracture management (open reduction and internal fixation or non-operative),
timing of THA
(>
/<
one year), and age (>
/<
55 years) had no significant
effect on
We obtained information from the Elective Orthopaedic
Centre on 1523 patients with baseline and six-month Oxford hip scores
(OHS) after undergoing primary hip replacement (THR) and 1784 patients
with Oxford knee scores (OKS) for primary knee replacement (TKR)
who completed a six-month satisfaction questionnaire. Receiver operating characteristic curves identified an absolute
change in
We undertook a retrospective cohort study to
determine clinical outcomes following the revision of metal-on-metal (MoM)
hip replacements for adverse reaction to metal debris (ARMD), and
to identify predictors of time to revision and outcomes following
revision. Between 1998 and 2012 a total of 64 MoM hips (mean age
at revision of 57.8 years; 46 (72%) female; 46 (72%) hip resurfacings
and 18 (28%) total hip replacements) were revised for ARMD at one specialist
centre. At a mean follow-up of 4.5 years (1.0 to 14.6) from revision
for ARMD there were 13 hips (20.3%) with post-operative complications
and eight (12.5%) requiring re-revision. . The Kaplan–Meier five-year survival rate for ARMD revision was
87.9% (95% confidence interval 78.9 to 98.0; 19 hips at risk). Excluding
re-revisions, the median absolute Oxford hip score (OHS) following
ARMD revision using the percentage method (0% best outcome and 100%
worst outcome) was 18.8% (interquartile range (IQR) 7.8% to 48.3%),
which is equivalent to 39/48 (IQR 24.8/48 to 44.3/48) when using
the modified
Aims. The aim of this study was to assess the effect of multimorbidity
on improvements in health-related quality of life (HRQoL) following
total hip arthroplasty (THA) and total knee arthroplasty (TKA). Patients and Methods. Using data from a regional joint registry for 14 573 patients,
HRQoL was measured prior and one year following surgery using the
Oxford Hip Score (OHS) and Oxford Knee Score (OKS), and the 12-Item
Short-Form Health Survey Physical and Mental Component Summary scores
(PCS and MCS, respectively). Multimorbidity was defined as the concurrence
of two or more self-reported chronic conditions. A linear mixed-effects
model was used to test the effects of multimorbidity and the number
of chronic conditions on improvements in HRQoL. Results. Almost two-thirds of patients had multimorbidity, which adversely
effected improvements in HRQoL. For THA, mean improvements in HRQoL
scores were reduced by 2.21 points in
Aims. The aim of this study was to assess the functional gain achieved following hip resurfacing arthroplasty (HRA). Patients and Methods. A total of 28 patients (23 male, five female; mean age, 56 years (25 to 73)) awaiting Birmingham HRA volunteered for this prospective gait study, with an age-matched control group of 26 healthy adults (16 male, ten female; mean age, 56 years (33 to 84)). The Oxford Hip Score (OHS) and gait analysis using an instrumented treadmill were used preoperatively and more than two years postoperatively to measure the functional change attributable to the intervention. Results. The mean
We assessed leg length discrepancy and hip function in 90 patients undergoing primary total hip arthroplasty before surgery and at three and 12 months after. Function was measured using the Oxford hip score (OHS). After surgery the mean
Aims. The classical longitudinal incision used for the direct anterior
approach (DAA) to the hip does not follow the tension lines of the
skin and can lead to impaired wound healing and poor cosmesis. The
purpose of this retrospective study was to determine the satisfaction
with the scar, and functional and radiographic outcomes comparing
the classic longitudinal incision with a modified skin crease ‘bikini’
when the DAA is used for total hip arthroplasty (THA). Patients and Methods. A total of 964 patients (51% female; 59% longitudinal, 41% ‘bikini’)
completed a follow-up questionnaire between two and four years postoperatively,
including the Oxford Hip Score (OHS), the University of North Carolina
‘4P’ scar scale (UNC4P) and two items for assessing the aesthetic
appearance of the scar and symptoms of numbness. The positioning
of the components, rates of heterotopic ossification (HO) and rates
of revision were assessed. Results. The mean
The Oxford hip score (OHS) is a patient-based instrument for assessment of outcome which is often used after total hip replacement, and the EuroQol 5D (EQ5D) is a patient-based generic questionnaire for health assessment. In an analysis of the outcome at one year of 609 revision hip replacements (RHRs), we compared the
Aims. To validate the English language Forgotten Joint Score-12 (FJS-12)
as a tool to evaluate the outcome of hip and knee arthroplasty in
a United Kingdom population. Patients and Methods. All patients undergoing surgery between January and August 2014
were eligible for inclusion. Prospective data were collected from
205 patients undergoing total hip arthroplasty (THA) and 231 patients
undergoing total knee arthroplasty (TKA). Outcomes were assessed
with the FJS-12 and the Oxford Hip and Knee Scores (OHS, OKS) pre-operatively,
then at six and 12 months post-operatively. Internal consistency,
convergent validity, effect size, relative validity and ceiling
effects were determined. Results. Data for the TKA and THA patients showed high internal consistency
for the FJS-12 (Cronbach α = 0.97 in TKAs, 0.98 in THAs). Convergent
validity with the Oxford Scores was high (r = 0.85 in TKAs, r =
0.79 for THAs). From six to 12 months, the change was higher for
the FJS-12 than for the
Aims. We evaluated the short-term functional outcome and prevalence
of bearing-specific generation of audible noise in 301 patients
(336 hips) operated on with fourth generation (Delta) medium diameter
head, ceramic-on-ceramic (CoC) total hip arthroplasties (THAs). Patients and Methods. There were 191 female (63%) and 110 male patients (37%) with
a mean age of 61 years (29 to 78) and mean follow-up of 2.1 years
(1.3 to 3.4). Patients completed three questionnaires: Oxford Hip
Score (OHS), Research and Development 36-item health survey (RAND-36)
and a noise-specific symptom questionnaire. Plain radiographs were also
analysed. A total of three hips (0.9%) were revised. . Results. There were 52 patients (54 hips, 17%) who reported noise, and
in 25 (48%) of them the noise was frequently heard. In the multiple
regression analysis, the only independent risk factor for noise
was a specific THA brand, with a threefold increased risk (95% confidence
intervals 1.39 to 6.45, p = 0.005) of noise compared with the reference
THA brand. Patients with noisy hips had lower median
Aims. Advocates of debridement, antibiotics and implant retention (DAIR)
in hip periprosthetic joint infection (PJI) argue that a procedure
not disturbing a sound prosthesis-bone interface is likely to lead
to better survival and functional outcome compared with revision.
This case-control study aims were to compare outcome of DAIRs for
infected primary total hip arthroplasty (THA) with outcomes following
primary THA and two-stage revision of infected primary THAs. Patients and Methods. We retrospectively reviewed all DAIRs, performed for confirmed
infected primary hip arthropasty (n = 82) at out institution, between
1997 and 2013. Data recorded included full patient information and
type of surgery. Outcome measures included complications, mortality,
implant survivorship and functional outcome. Outcome was compared with
two control groups matched for gender and age; a cohort of primary
THAs (n = 120) and a cohort of two-stage revisions for infection
(n = 66). Results. Mean age at DAIR was 69 years (33 to 87) and mean follow-up was
eight years (2 to 17; standard deviation (. sd). 5). A total
of 52 (63%) of DAIRs were for early PJI (less than six weeks). Greater
success in the eradication of infection with DAIR was identified
with early PJI, comprising an interval less than a week between
onset of symptoms and exchange of modular components with the DAIR
procedure. Eradication of infection, complications and re-operation
rates were similar in the DAIR and two-stage revision groups. For
hips with successful eradication of infection with DAIR, the five-year
survival (98%; 95% confidence interval (CI) 94 to 100) was similar
to the primary THA group (98%; 95% CI 95 to 100) (n = 43; p = 0.3).
The DAIR group had inferior mean Oxford Hip Scores (OHS) (38; 12
to 48) compared with the primary THA group (42; 15 to 48) (p = 0.02)
but a significantly better mean
Periprosthetic femoral fracture (PFF) is a potentially
devastating complication after total hip arthroplasty, with historically
high rates of complication and failure because of the technical
challenges of surgery, as well as the prevalence of advanced age
and comorbidity in the patients at risk. This study describes the short-term outcome after revision arthroplasty
using a modular, titanium, tapered, conical stem for PFF in a series
of 38 fractures in 37 patients. The mean age of the cohort was 77 years (47 to 96). A total of
27 patients had an American Society of Anesthesiologists grade of
at least 3. At a mean follow-up of 35 months (4 to 66) the mean
Oxford Hip Score (OHS) was 35 (15 to 48) and comorbidity was significantly
associated with a poorer
The primary aim of this trial was to compare the subsidence of two similar hydroxyapatite-coated titanium femoral components from different manufacturers. Secondary aims were to compare rotational migration (anteversion/retroversion and varus/valgus tilt) and patient-reported outcome measures between both femoral components. Patients were randomized to receive one of the two femoral components (Avenir or Corail) during their primary total hip arthroplasty between August 2018 and September 2020. Radiostereometric analysis examinations at six, 12, and 24 months were used to assess the migration of each implanted femoral component compared to a baseline assessment. Patient-reported outcome measures were also recorded for these same timepoints. Overall, 50 patients were enrolled (62% male (n = 31), with a mean age of 65.7 years (SD 7.3), and mean BMI of 30.2 kg/m2 (SD 5.2)).Aims
Methods
If patients could recall their physical status
before total hip (THA) or knee arthroplasty (TKA) accurately it
could have valuable applications both clinically and for research.
This study evaluated the accuracy of a patient’s recollection one
year after either THA or TKA using the Oxford hip or knee scores
(OHS and OKS). In total, 113 patients (59 THA, 54 TKA) who had completed
the appropriate score pre-operatively were asked to complete the
score again at a mean of 12.4 months (standard deviation (. sd. )
0.8) after surgery, recalling their pre-operative state. While there were no significant differences between the actual
and recalled pre-operative scores (OHS mean difference 0.8, . sd. 6.21,
95% confidence interval (CI) -0.82 to 2.42,
p = 0.329; OKS mean difference -0.11, . sd. 7.34, 95% CI -2.11
to 1.89, p = 0.912), absolute differences were relatively large
(OHS, 5.24; OKS, 5.41), correlation was weak (OHS r = 0.7, OKS r
= 0.61) and agreement between actual and recalled responses for
individual questions was poor in half of the
Our aim was to define the minimum set of patient-reported outcome measures which are required to assess health status after total hip replacement (THR). In 114 patients, we compared the pre-operative characteristics and sensitivity to change of the Oxford hip score (OHS), the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), the SF-36, the SF-12 (derived from the SF-36), and the Euroqol questionnaire (EQ-5D). At one year after operation, very large effect sizes were found for the disease-specific measures, the physical domains of the SF-12, SF-36 and the EQ-5D. index. (1.3 to 3.0). Patients in Charnley class A showed more change in the
To assess the feasibility of a randomized controlled trial (RCT) that compares three treatments for acetabular fractures in older patients: surgical fixation, surgical fixation and hip arthroplasty (fix-and-replace), and non-surgical treatment. Patients were recruited from seven UK NHS centres and randomized to a three-arm pilot trial if aged older than 60 years and had a displaced acetabular fracture. Feasibility outcomes included patients’ willingness to participate, clinicians’ capability to recruit, and dropout rates. The primary clinical outcome measure was the EuroQol five-dimension questionnaire (EQ-5D) at six months. Secondary outcomes were Oxford Hip Score, Disability Rating Index, blood loss, and radiological and mobility assessments.Aims
Methods
Aims. We assessed the difference in hospital based and early clinical
outcomes between the direct anterior approach and the posterior
approach in patients who undergo total hip arthroplasty (THA). Patients and Methods. The outcome was assessed in 448 (203 males, 245 females) consecutive
patients undergoing unilateral primary THA after the implementation
of an ‘Enhanced Recovery’ pathway. In all, 265 patients (mean age:
71 years (49 to 89); 117 males and 148 females) had surgery using
the direct anterior approach (DAA) and 183 patients (mean age: 70
years (26 to 100); 86 males and 97 females) using a posterior approach.
The groups were compared for age, gender, American Society of Anesthesiologists
grade, body mass index, the side of the operation, pre-operative
Oxford Hip Score (OHS) and attendance at ‘Joint school’. Mean follow-up
was 18.1 months (one to 50). Results. There was no significant difference in mean length of stay (p
= 0.07), pain scores on the day of surgery, the first, second and
third post-operative days (p = 0.36, 0.23, 0.25 and 0.59, respectively),
the day of mobilisation (p = 0.12), the mean
Refobacin Bone Cement R and Palacos Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected.Aims
Methods
The aim of this study was to report health-related quality of life (HRQoL) and joint-specific function in patients waiting for total hip or knee arthroplasty surgery (THA or TKA) in Northern Ireland, compared to published literature and a matched normal population. Secondary aims were to report emergency department (ED) and out-of-hours general practitioner (OOH GP) visits, new prescriptions of strong opioids, and new prescriptions of antidepressants while waiting. This was a cohort study of 991 patients on the waiting list for arthroplasty in a single Northern Ireland NHS trust: 497 on the waiting list for ≤ three months; and 494 waiting ≥ three years. Postal surveys included the EuroQol five-dimension five-level questionnaire (EQ-5D-5L), visual analogue scores (EQ-VAS), and Oxford Hip and Knee scores to assess HRQoL and joint-specific function. Electronic records determined prescriptions since addition to the waiting list and patient attendances at OOH GP/EDs.Aims
Methods
Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.Aims
Methods
We obtained pre-operative and six-month post-operative
Oxford hip (OHS) and knee scores (OKS) for 1523 patients who underwent
total hip replacement and 1784 patients who underwent total knee
replacement. They all also completed a six-month satisfaction question. . Scatter plots showed no relationship between pre-operative Oxford
scores and six-month satisfaction scores. Spearman’s rank correlation
coefficients were -0.04 (95% confidence interval (CI) -0.09 to 0.01)
between
The aim of this study is to report the long-term outcomes of instrumented femoral revisions with impaction allograft bone grafting (IBG) using the X-change femoral revision system at 30 years after introduction of the technique. We updated the outcomes of our previous study, based on 208 consecutive revisions using IBG and the X-change femoral revision system in combination with a cemented polished stem, performed in our tertiary care institute between 1991 and 2007. Kaplan-Meier survival analyses were used to determine the survival rate of the revisions with endpoint revision for any reason and aseptic loosening. Secondary outcomes were radiological loosening and patient-reported outcome measures.Aims
Methods
The Birmingham Hip Resurfacing (BHR) arthroplasty has been used as a surgical treatment of coxarthrosis since 1997. We present 20-year results of 234 consecutive BHRs performed in our unit. Between 1999 and 2001, there were 217 patients: 142 males (65.4%), mean age 52 years (18 to 68) who had 234 implants (17 bilateral). They had patient-reported outcome measures collected, imaging (radiograph and ultrasound), and serum metal ion assessment. Survivorship analysis was performed using Kaplan-Meier estimates. Revision for any cause was considered as an endpoint for the analysis.Aims
Methods
Recent events have highlighted the importance
of implant design for survival and wear-related complications following
metal-on-metal hip resurfacing arthroplasty. The mid-term survival
of the most widely used implant, the Birmingham Hip Resurfacing
(BHR), has been described by its designers. The aim of this study
was to report the ten-year survival and patient-reported functional
outcome of the BHR from an independent centre. In this cohort of 554 patients (646 BHRs) with a mean age of
51.9 years (16.5 to 81.5) followed for a mean of eight years (1
to 12), the survival and patient-reported functional outcome depended
on gender and the size of the implant. In female hips (n = 267)
the ten-year survival was 74% (95% confidence interval (CI) 83 to
91), the ten-year revision rate for pseudotumour was 7%, the mean
Oxford hip score (OHS) was 43 (. sd. 8) and the mean UCLA
activity score was 6.4 (. sd. 2). In male hips (n = 379) the
ten-year survival was 95% (95% CI 92.0 to 97.4), the ten-year revision rate
for pseudotumour was 1.7%, the mean
Aims. We present the clinical and radiological results at a minimum
follow-up of five years for patients who have undergone multiple
cement-in-cement revisions of their femoral component at revision
total hip arthroplasty (THA). Patients and Methods. We reviewed the outcome on a consecutive series of 24 patients
(10 men, 14 women) (51 procedures) who underwent more than one cement-in-cement
revision of the same femoral component. The mean age of the patients was
67.5 years (36 to 92) at final follow-up. Function was assessed using the original Harris hip score (HHS),
Oxford Hip Score (OHS) and the Merle D’Aubigné Postel score (MDP). Results. The mean length of follow-up was 81.7 months (64 to 240). A total
of 41 isolated acetabular revisions were performed in which stem
removal facilitated access to the acetabulum, six revisions were
conducted for loosening of both components and two were isolated
stem revisions (each of these patients had undergone at least two revisions). There was significant improvement in the
The aim of this study was to estimate the clinical and economic burden of dislocation following primary total hip arthroplasty (THA) in England. This retrospective evaluation used data from the UK Clinical Practice Research Datalink database. Patients were eligible if they underwent a primary THA (index date) and had medical records available 90 days pre-index and 180 days post-index. Bilateral THAs were excluded. Healthcare costs and resource use were evaluated over two years. Changes (pre- vs post-THA) in generic quality of life (QoL) and joint-specific disability were evaluated. Propensity score matching controlled for baseline differences between patients with and without THA dislocation.Aims
Methods
BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems. A total of 53 patients were randomized to be treated using Bi-Metric cementless femoral stems with either only a porous titanium plasma-sprayed coating (P group) or a porous titanium plasma-sprayed coating with an additional BoneMaster coating (PBM group). The patients were examined with radiostereometry until five years after surgery.Aims
Methods