Advertisement for orthosearch.org.uk
Results 1 - 50 of 290
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1385 - 1390
1 Oct 2005
Niva MH Kiuru MJ Haataja R Pihlajamäki HK

The purpose of this study was to describe the anatomical distribution and incidence of fatigue injuries of the femur in physically-active young adults, based upon MRI studies. During a period of 70 months, 1857 patients with exercise-induced pain in the femur underwent MRI of the pelvis, hips, femora, and/or knees. Of these, 170 patients had a total of 185 fatigue injuries, giving an incidence of 199 per 100 000 person-years. Bilateral injuries occurred in 9% of patients. The three most common sites affected were the femoral neck (50%), the condylar area (24%) and the proximal shaft (18%). A fatigue reaction was seen in 57%, and a fracture line in 22%. There was a statistical correlation between the severity of the fatigue injury and the duration of pain (p = 0.001). The location of the pain was normally at the site of the fatigue injury. Fatigue injuries of the femur appear to be relatively common in physically-active patients


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 2 | Pages 266 - 279
1 May 1948
Burrows HJ

1. A hope expressed in 1940, that further cases of spontaneous fracture of the lowest third of the apparently normal fibula would be described, has been fulfilled. The literature is here reviewed. Five further personal cases are added. 2. The clinical and radiographic features, diagnosis, treatment and results are considered in the light of the information so far available. Special note is made of misleading freedom of ankle and tarsal movements and the occasional absence of tenderness. 3. It is established that fractures of the lowest third occur particularly in two groups of subjects: 1) young male runners and skaters; 2) active and hard-pressed women of middle age and over. 4. In male runners and skaters the fracture usually occurs through slender, mainly cortical bone, two inches or more above the tip of the lateral malleolus; in middle-aged women the fracture is usually distal to the interosseous ligament through thicker, mainly cancellous bone, one and a half inches from the tip of the lateral malleolus. 5. The most convenient name for both groups of fractures in the lowest third is low fatigue fracture of the fibula. 6. A review of the literature of fatigue fracture of the uppermost third of the fibula shows that it is very often precipitated by jumping. The most convenient name for it is high fatigue fracture of the fibula. 7. Like all clinical classifications this distinction between low and high fractures has exceptions (a low fracture of one fibula in a runner was followed later by a high fracture of the other; most military fractures were high, but a few may have occurred at other levels). 8. Fatigue fracture of the fibula, high or low, may be bilateral. 9. A fracture similarly situated to the high fatigue fracture of the fibula has been frequent in parachute schools. It is a speculative possibility that military and parachutist fractures of the upper third of the fibula indicate the link between true fatigue fractures (as exemplified by march fractures with minimal trauma often repeated) and purely traumatic fractures (with adequate trauma applied once only)


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1574 - 1579
1 Dec 2006
Pihlajamäki HK Ruohola J Weckström M Kiuru MJ Visuri TI

The incidence and long-term outcome of undisplaced fatigue fractures of the femoral neck treated conservatively were examined in Finnish military conscripts between 1970 and 1990. From 106 cases identified, 66 patients with 70 fractures were followed for a mean of 18.3 years (11 to 32). The original medical records and radiographs were studied and physical and radiological follow-up data analysed for evidence of risk factors for this injury. The development of avascular necrosis and osteoarthritis was determined from the follow-up radiographs and MR scans. The impact of new military instructions on the management of hip-related pain was assessed following their introduction in 1986. The preventive regimen (1986) improved awareness and increased the detected incidence from 13.2 per 100 000 service-years (1970 to 1986) to 53.2 per 100 000 (1987 to 1990). No patient developed displacement of the fracture or avascular necrosis of the femoral head, or suffered from adverse complications. No differences were found in MRI-measured hip joint spaces at final follow-up. The mean Harris Hip Score was 97 (70 to 100) and the Visual Analogue Scale 5.85 mm (0 to 44). Non-operative treatment, including avoidance of or reduced weight-bearing, gave favourable short- and long-term outcomes. Undisplaced fatigue fractures of the femoral neck neither predispose to avascular necrosis nor the subsequent development of osteoarthritis of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 241 - 248
1 Feb 2012
Firoozabadi R McDonald E Nguyen T Buckley JM Kandemir U

Filling the empty holes in peri-articular locking plates may improve the fatigue strength of the fixation. The purpose of this in vitro study was to investigate the effect of plugging the unused holes on the fatigue life of peri-articular distal femoral plates used to fix a comminuted supracondylar fracture model. A locking/compression plate was applied to 33 synthetic femurs and then a 6 cm metaphyseal defect was created (AO Type 33-A3). The specimens were then divided into three groups: unplugged, plugged with locking screw only and fully plugged holes. They were then tested using a stepwise or run-out fatigue protocol, each applying cyclic physiological multiaxial loads. All specimens in the stepwise group failed at the 770 N load level. The mean number of cycles to failure for the stepwise specimen was 25 500 cycles (. sd. 1500), 28 800 cycles (. sd.  6300), and 26 400 cycles (. sd. 2300) cycles for the unplugged, screw only and fully plugged configurations, respectively (p = 0.16). The mean number of cycles to failure for the run-out specimens was 42 800 cycles (. sd. 10 700), 36 000 cycles (. sd. 7200), and 36 600 cycles (. sd.  10 000) for the unplugged, screw only and fully plugged configurations, respectively (p = 0.50). There were also no differences in axial or torsional stiffness between the constructs. The failures were through the screw holes at the level of comminution. In conclusion, filling the empty combination locking/compression holes in peri-articular distal femur locking plates at the level of supracondylar comminution does not increase the fatigue life of the fixation in a comminuted supracondylar femoral fracture model (AO 33-A3) with a 6 cm gap


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (. sd. 33 900) vs 12 800 cycles (. sd. 6100); p = 0.007) and mean axial stiffness (220 N/mm (. sd. 80) vs 70 N/mm (. sd. 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (. sd. 0.9) vs 5.1 Nm/° (. sd. 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (. sd. 25 600) vs 52 400 cycles (. sd. 22 500); p = 0.04). The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients. Cite this article: Bone Joint J 2014;96-B:114–21


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 4 | Pages 723 - 728
1 Nov 1972
Todd RC Freeman MAR Pirie CJ

1. The femoral head has been examined in specimens taken from cadavers, patients suffering subcapital fracture of the femoral neck and patients undergoing total replacement arthroplasty for osteoarthrosis and rheumatoid arthritis. 2. Lesions have been seen, some of which appear to be uniting fatigue fractures of individual trabeculae. 3. It is suggested that excessive cyclical loading, sometimes leading to fatigue fractures, may represent a fundamental pathological process of general importance in the evolution of certain skeletal and articular diseases


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 4 | Pages 698 - 702
1 Nov 1974
Freeman MAR Todd RC Pirie CJ

1. Senile subcapital fractures in osteoporotic patients are due to fatigue, not to the impact of a fall, since they are preceded by the local accumulation of isolated trabecular fatigue fractures. 2. One pathological significance of the isolated trabecular fractures described by Todd, Freeman and Pirie (1972) has been demonstrated


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 1 | Pages 83 - 94
1 Feb 1956
Burrows HJ

1. A defect of the middle of one tibial crest is described in young healthy ballet dancers. 2. The clinical and radiological characteristics have been studied in four cases, and the histological appearances in two. 3. The defect is concluded to be an incomplete fatigue fracture—a fatigue infraction. 4. A fifth, uncertain, case has been added tentatively, as presenting a possible serious complication, namely acute fracture from muscle action. 5. The diagnosis, treatment and prognosis are mentioned, with emphasis on the importance of adequate clinical and radiological examination in cases of obscure mid-tibial pain, tenderness or swelling


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 1 | Pages 136 - 143
1 Feb 1971
Griffiths WEG Swanson SAV Freeman MAR

1. Thirty-seven specimens of the proximal third of the human femur were subjected to cyclically varying loads applied in a physiological direction to the femoral head, having maximum values of from four to thirteen times body weight. 2. Ten of these specimens sustained subcapital fractures of the femoral neck after numbers of cycles of loading varying from 123 to 8,193. 3. The maximum value of cyclic load needed to give fatigue fracture after 10,000 or fewer cycles was found to vary from about twelve times the body weight at ages twenty to fifty to about five times the body weight at age seventy or more. 4. In youth and in middle age the load levels mentioned above are greater than those encountered in normal living, but are comparable to those which may be applied to the femoral head during activities known to produce "fatigue" fractures clinically in young adults. 5. In the elderly the load levels mentioned above are within the range that can be applied in normal living. It is inferred that some femoral neck fractures in the elderly may be fatigue fractures caused by the cyclic loading of normal walking


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 4 | Pages 618 - 621
1 Nov 1955
Evans DL

1. Two cases of fatigue fracture of the ulna are reported. 2. Three cases previously reported are reviewed and a striking similarity with one of the present cases is noted. 3. In all cases the mechanism of injury appears to have been the same


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 4 | Pages 581 - 594
1 Nov 1948
Hughes JR

1. Three cases are reported of ischaemic necrosis of the anterior tibial muscles which were not due to injury. In two, ischaemia was the result of strenuous or unaccustomed exercise in young adults; in the third it was an incident in a systemic disturbance. All three cases were probably the result of spasm of a large segment of the anterior tibial artery. 2. The clinical features during the first few hours resemble those of tenosynovitis of the tibialis anterior; and after twelve to twenty-four hours those of cellulitis of the leg. Later there is "drop foot" due to muscle weakness, contracture limiting plantar-flexion movement, and woody hardness of the muscles in the middle third. 3. The morbid histology is similar to that of Volkmann's ischaemic contracture. 4. The possible explanations—primary arterial disease, arterial occlusion by pressure of the interosseous membrane, occlusion by tension within the fascial space, intraluminary occlusion by embolism or thrombosis, and fatigue arterial spasm, are discussed. 5. The vascular pattern of the anterior tibial muscles has been studied by experimental injections in cadavers. 6. It is concluded that the most likely cause is spasm of the anterior tibial artery due to muscle fatigue, aggravated by increased tension within the anterior fascial compartment due to reaction after strenuous exercise. 7. Treatment is outlined. Exploration of the anterior tibial artery within the first twelve hours is warranted, but late exploration may be dangerous. 8. Although not previously recognised, evidence is shown that regeneration of necrotic muscle is possible in the human being


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 199 - 203
1 Mar 1983
Adams M Hutton W

Forty-one cadaveric lumbar intervertebral joints from 18 spines were flexed and fatigue loaded to simulate a vigorous day's activity. The joints were then bisected and the discs examined. Twenty-three out of 41 of the discs showed distortions in the lamellae of the annulus fibrosus and, in a few of these, complete radial fissures were found in the posterior annulus


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 4 | Pages 647 - 651
1 Nov 1954
Singer M Maudsley RH

1. Five patients with seven fatigue fractures of the lower third of the tibia are described; two had bilateral fractures. There is a striking similarity in the site and appearance of these fractures. 2. All occurred in middle-aged or elderly people without a history of unusual activity or illness. 3. The fractures are so nearly identical as to constitute an entity which, as far as we are aware, has not been described before


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 2 | Pages 302 - 305
1 May 1957
Murray DS

1. A case is described of fatigue fractures occurring in the lowest thirds of the right tibia and fibula simultaneously. 2. The fibular fracture was a runner's fracture. 3. The tibial fracture was ascribed to the application of a below-knee walking plaster to treat the fibular lesion. 4. Both fractures were slow in uniting. 5. The fractures occurred in a rapidly growing youth but no clinical evidence of an endocrine dysfunction was found


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 20 - 24
1 Jan 1991
Cook S Thomas K

The causes of mechanical failure of five noncemented porous-coated components were studied. There were two cobalt-chromium alloy and three titanium alloy implants which fractured after 12 to 48 months. The implants included one acetabular component, and one femoral condylar, one patellar and two tibial components. Examination of the fractured surfaces revealed fatigue to be the mechanism of failure in all cases. The porous coating and the processes required for its fabrication had resulted in weakening and reduction of substrate thickness. Additional factors were stress concentration due to limited, localised bone ingrowth, and some features of the design of the implants


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 3 | Pages 688 - 688
1 Aug 1968
Wainwright D


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 4 | Pages 622 - 623
1 Nov 1948
Kitchin ID


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 2 | Pages 234 - 238
1 May 1978
Cyron B Hutton W


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 181 - 182
1 Mar 1997
Taylor M Tanner KE


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 867 - 871
1 Jul 2019
Wilcox M Brown H Johnson K Sinisi M Quick TJ

Aims. Improvements in the evaluation of outcomes following peripheral nerve injury are needed. Recent studies have identified muscle fatigue as an inevitable consequence of muscle reinnervation. This study aimed to quantify and characterize muscle fatigue within a standardized surgical model of muscle reinnervation. Patients and Methods. This retrospective cohort study included 12 patients who underwent Oberlin nerve transfer in an attempt to restore flexion of the elbow following brachial plexus injury. There were ten men and two women with a mean age of 45.5 years (27 to 69). The mean follow-up was 58 months (28 to 100). Repeated and sustained isometric contractions of the elbow flexors were used to assess fatigability of reinnervated muscle. The strength of elbow flexion was measured using a static dynamometer (KgF) and surface electromyography (sEMG). Recordings were used to quantify and characterize fatigability of the reinnervated elbow flexor muscles compared with the uninjured contralateral side. Results. The mean peak force of elbow flexion was 7.88 KgF (. sd. 3.80) compared with 20.65 KgF (. sd . 6.88) on the contralateral side (p < 0.001). Reinnervated elbow flexor muscles (biceps brachialis) showed sEMG evidence of fatigue earlier than normal controls with sustained (60-second) isometric contraction. Reinnervated elbow flexor muscles also showed a trend towards a faster twitch muscle fibre type. Conclusion. The assessment of motor outcomes must involve more than peak force alone. Reinnervated muscle shows a shift towards fast twitch fibres following reinnervation with an earlier onset of fatigue. Our findings suggest that fatigue is a clinically relevant characteristic of reinnervated muscle. Adoption of these metrics into clinical practice and the assessment of outcome could allow a more meaningful comparison to be made between differing forms of treatment and encourage advances in the management of motor recovery following nerve transfer. Cite this article: Bone Joint J 2019;101-B:867–871


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1099 - 1105
1 Aug 2016
Weiser L Dreimann M Huber G Sellenschloh K Püschel K Morlock MM Rueger JM Lehmann W

Aims. Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation. Materials and Methods. A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force. Results. Augmentation showed no significant increase in the mean cycles to failure and fatigue force (SHORT p = 0.067; EXTENDED p = 0.239). Extending the instrumentation resulted in a significantly increased number of cycles to failure and a significantly higher fatigue force compared with the SHORT instrumentation (EXTENDED non-augmented + 76%, p < 0.001; EXTENDED augmented + 87%, p < 0.001). Conclusion. The stabilising effect of cement augmentation of pedicle screws might not be as beneficial as expected from biomechanical pull-out tests. Lengthening the dorsal instrumentation results in a much higher increase of stability during fatigue testing in the osteoporotic spine compared with cement augmentation. Cite this article: Bone Joint J 2016;98-B:1099–1105


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 454 - 460
1 Mar 2010
Baleani M Bialoblocka-Juszczyk E Engels GE Viceconti M

We investigated the effect of pre-heating a femoral component on the porosity and strength of bone cement, with or without vacuum mixing used for total hip replacement. Cement mantles were moulded in a manner simulating clinical practice for cemented hip replacement. During polymerisation, the temperature was monitored. Specimens of cement extracted from the mantles underwent bending or fatigue tests, and were examined for porosity. Pre-heating the stem alone significantly increased the mean temperature values measured within the mantle (+14.2°C) (p < 0.001) and reduced the mean curing time (−1.5 min) (p < 0.001). The addition of vacuum mixing modulated the mean rise in the temperature of polymerisation to 11°C and reduced the mean duration of the process by one minute and 50 seconds (p = 0.01 and p < 0.001, respectively). In all cases, the maximum temperature values measured in the mould simulating the femur were < 50°C. The mixing technique and pre-heating the stem slightly increased the static mechanical strength of bone cement. However, the fatigue life of the cement was improved by both vacuum mixing and pre-heating the stem, but was most marked (+ 280°C) when these methods were combined. Pre-heating the stem appears to be an effective way of improving the quality of the cement mantle, which might enhance the long-term performance of bone cement, especially when combined with vacuum mixing


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 516 - 521
1 Apr 2018
Qian L Jiang C Sun P Xu D Wang Y Fu M Zhong S Ouyang J

Aims. The aim of this study was to compare the peak pull-out force (PPF) of pedicle-lengthening screws (PLS) and traditional pedicle screws (TPS) using instant and cyclic fatigue testing. Materials and Methods. A total of 60 lumbar vertebrae were divided into six groups: PLS submitted to instant pull-out and fatigue-resistance testing (groups A1 and A2, respectively), TPS submitted to instant pull-out and fatigue-resistance testing (groups B1 and B2, respectively) and PLS augmented with 2 ml polymethylmethacrylate, submitted to instant pull-out and fatigue-resistance testing (groups C1 and C2, respectively). The PPF and normalized PPF (PPFn) for bone mineral density (BMD) were compared within and between all groups. Results. In all groups, BMD was significantly correlated with PPF (r = 0.83, p < 0.001). The PPFn in A1 was significantly less than in B1 (p = 0.006) and C1 (p = 0.002). The PPFn of A2 was significantly less than in B2 (p < 0.001) and C2 (p < 0.001). The PPFn in A1, B1, and C1 was significantly greater than in A2 (p = 0.002), B2 (p = 0.027), and C2 (p = 0.003). There were no significant differences in PPFn between B1 and C1, or between B2 and C2. Conclusion. Pedicle lengthening screws with cement augmentation can provide the same fixation stability as traditional pedicle screws and may be a viable clinical option. Cite this article: Bone Joint J 2018;100-B:516–21


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1190 - 1196
1 Sep 2017
Swarup I Henn CM Nguyen JT Dines DM Craig EV Warren RF Gulotta LV Henn III RF

Aims . Few studies have evaluated the relationship between patients’ pre-operative expectations and the outcome of orthopaedic procedures. Our aim was to determine the effect of expectations on the outcome after primary anatomical total shoulder arthroplasty (TSA). We hypothesised that patients with greater expectations would have better outcomes. . Patients and Methods. Patients undergoing primary anatomical TSA completed the Hospital for Special Surgery’s Shoulder Expectations Survey pre-operatively. The American Shoulder and Elbow Surgeons (ASES), Shoulder Activity Scale (SAS), Short-Form-36 (SF-36), and visual analogue scale (VAS) for pain, fatigue, and general health scores were also collected pre-operatively and two years post-operatively. Pearson correlations were used to assess the relationship between the number of expectations and the outcomes. Differences in outcomes between those with higher and lower levels of expectations for each expectation were assessed by independent samples t-test. Multivariable linear regression analysis was used to control for potential confounding factors. Results. A total of 67 patients were evaluated two years post-operatively. Most parameters of outcome improved significantly from baseline and most patients were satisfied. A greater number of expectations was associated with a significantly greater improvement in the ASES score (p = 0.02). In the multivariable analysis, a greater number of expectations was an independent predictor of better ASES, VAS and SF-36 scores, as well as improvements in ASES and VAS pain scores (p < 0.05). Greater expectations for many specific expectation questions were significantly associated with better outcomes (p < 0.05). Conclusion. TSA is a successful procedure with significant improvements in outcome, and greater pre-operative expectations are associated with better outcomes. . Cite this article: Bone Joint J 2017;99-B:1190–6


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 151 - 157
1 Feb 2024
Dreyer L Bader C Flörkemeier T Wagner M

Aims

The risk of mechanical failure of modular revision hip stems is frequently mentioned in the literature, but little is currently known about the actual clinical failure rates of this type of prosthesis. The current retrospective long-term analysis examines the distal and modular failure patterns of the Prevision hip stem from 18 years of clinical use. A design improvement of the modular taper was introduced in 2008, and the data could also be used to compare the original and the current design of the modular connection.

Methods

We performed an analysis of the Prevision modular hip stem using the manufacturer’s vigilance database and investigated different mechanical failure patterns of the hip stem from January 2004 to December 2022.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 596 - 602
1 Jun 2024
Saarinen AJ Sponseller P Thompson GH White KK Emans J Cahill PJ Hwang S Helenius I

Aims

The aim of this study was to compare outcomes after growth-friendly treatment for early-onset scoliosis (EOS) between patients with skeletal dysplasias versus those with other syndromes.

Methods

We retrospectively identified 20 patients with skeletal dysplasias and 292 with other syndromes (control group) who had completed surgical growth-friendly EOS treatment between 1 January 2000 and 31 December 2018. We compared radiological parameters, complications, and health-related quality of life (HRQoL) at mean follow-up of 8.6 years (SD 3.3) in the dysplasia group and 6.6 years (SD 2.6) in the control group.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 39 - 42
1 Jan 1989
Davies J Jasty M O'Connor D Burke D Harrigan T Harris W

We have tested the porosity and fatigue life of five commonly used bone cements: Simplex P, LVC, Zimmer regular, CMW and Palacos R. Tests were conducted with and without centrifugation and with the monomer at room temperature and, except for LVC, at 0 degrees C. We found that the fatigue life of different specimens varied by a factor of nearly 100. It did not depend on porosity alone, but was more influenced by the basic composition of the cement. Simplex P when mixed with monomer at 0 degrees C and centrifuged for 60 seconds had the highest fatigue life and was still sufficiently liquid to use easily


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1485 - 1492
1 Dec 2024
Terek RM

Aims

The aim of the LightFix Trial was to evaluate the clinical outcomes for one year after the treatment of impending and completed pathological fractures of the humerus using the IlluminOss System (IS), and to analyze the performance of this device.

Methods

A total of 81 patients with an impending or completed pathological fracture were enrolled in a multicentre, open label single cohort study and treated with IS. Inclusion criteria were visual analogue scale (VAS) Pain Scores > 60 mm/100 mm and Mirels’ Score ≥ 8. VAS pain, Musculoskeletal Tumor Society (MSTS) Upper Limb Function, and The European Organization for Research and Treatment of Cancer QoL Group Bone Metastases Module (QLQ-BM22) scores were all normalized to 100, and radiographs were obtained at baseline and at 14, 30, 90, 180, and 360 days postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1070 - 1077
1 Oct 2023
Png ME Costa M Nickil A Achten J Peckham N Reed MR

Aims

To compare the cost-effectiveness of high-dose, dual-antibiotic cement versus single-antibiotic cement for the treatment of displaced intracapsular hip fractures in older adults.

Methods

Using data from a multicentre randomized controlled trial (World Hip Trauma Evaluation 8 (WHiTE-8)) in the UK, a within-trial economic evaluation was conducted. Resource usage was measured over 120 days post randomization, and cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY), gained from the UK NHS and personal social services (PSS) perspective in the base-case analysis. Methodological uncertainty was addressed using sensitivity analysis, while decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1052 - 1059
1 Oct 2023
El-Sahoury JAN Kjærgaard K Ovesen O Hofbauer C Overgaard S Ding M

Aims

The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA).

Methods

A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1662 - 1667
1 Dec 2015
Weber-Spickschen TS Alfke D Agneskirchner JD

If a modular convertible total shoulder system is used as a primary implant for an anatomical total shoulder arthroplasty, failure of the prosthesis or the rotator cuff can be addressed by converting it to a reverse shoulder arthroplasty (RSA), with retention of the humeral stem and glenoid baseplate. This has the potential to reduce morbidity and improve the results. . In a retrospective study of 14 patients (15 shoulders) with a mean age of 70 years (47 to 83) we reviewed the clinical and radiological outcome of converting an anatomical shoulder arthroplasty (ASA) to a RSA using a convertible prosthetic system (SMR system, Lima, San Daniele, Italy). . The mean operating time was 64 minutes (45 to 75). All humeral stems and glenoid baseplates were found to be well-fixed and could be retained. There were no intra-operative or early post-operative complications and no post-operative infection. The mean follow-up was 43 months (21 to 83), by which time the mean visual analogue scale for pain had decreased from 8 pre-operatively to 1, the mean American Shoulder and Elbow Surgeons Score from 12 to 76, the mean Oxford shoulder score from 3 to 39, the mean Western Ontario Osteoarthritis of the Shoulder Score from 1618 to 418 and the mean Subjective shoulder value from 15 to 61. On radiological review, one patient had a lucency around the humeral stem, two had stress shielding. There were no fatigue fractures of the acromion but four cases of grade 1 scapular notching. . The use of a convertible prosthetic system to revise a failed ASA reduces morbidity and minimises the rate of complications. The mid-term clinical and radiological results of this technique are promising. Cite this article: Bone Joint J 2015;97-B:1662–7


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 465 - 465
15 Mar 2023


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1033 - 1037
1 Oct 2023
Mancino F Gabr A Plastow R Haddad FS

The anterior cruciate ligament (ACL) is frequently injured in elite athletes, with females up to eight times more likely to suffer an ACL tear than males. Biomechanical and hormonal factors have been thoroughly investigated; however, there remain unknown factors that need investigation. The mechanism of injury differs between males and females, and anatomical differences contribute significantly to the increased risk in females. Hormonal factors, both endogenous and exogenous, play a role in ACL laxity and may modify the risk of injury. However, data are still limited, and research involving oral contraceptives is potentially associated with methodological and ethical problems. Such characteristics can also influence the outcome after ACL reconstruction, with higher failure rates in females linked to a smaller diameter of the graft, especially in athletes aged < 21 years. The addition of a lateral extra-articular tenodesis can improve the outcomes after ACL reconstruction and reduce the risk of failure, and it should be routinely considered in young elite athletes. Sex-specific environmental differences can also contribute to the increased risk of injury, with more limited access to and availablility of advanced training facilities for female athletes. In addition, football kits are designed for male players, and increased attention should be focused on improving the quality of pitches, as female leagues usually play the day after male leagues. The kit, including boots, the length of studs, and the footballs themselves, should be tailored to the needs and body shapes of female athletes. Specific physiotherapy programmes and training protocols have yielded remarkable results in reducing the risk of injury, and these should be extended to school-age athletes. Finally, psychological factors should not be overlooked, with females’ greater fear of re-injury and lack of confidence in their knee compromising their return to sport after ACL injury. Both intrinsic and extrinsic factors should be recognized and addressed to optimize the training programmes which are designed to prevent injury, and improve our understanding of these injuries.

Cite this article: Bone Joint J 2023;105-B(10):1033–1037.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 481 - 486
1 May 2023
Scott CEH Jain S Moran M Haddad FS

The Unified Classification System (UCS), or Vancouver system, is a validated and widely used classification system to guide the management of periprosthetic femoral fractures. It suggests that well-fixed stems (type B1) can be treated with fixation but that loose stems (types B2 and B3) should be revised. Determining whether a stem is loose can be difficult and some authors have questioned how to apply this classification system to polished taper slip stems which are, by definition, loose within their cement mantle. Recent evidence has challenged the common perception that revision surgery is preferable to fixation surgery for UCS-B periprosthetic fractures around cemented polished taper slip stems. Indications for fixation include an anatomically reducible fracture and cement mantle, a well-fixed femoral bone-cement interface, and a well-functioning acetabular component. However, not all type B fractures can or should be managed with fixation due to the risk of early failure. This annotation details specific fracture patterns that should not be managed with fixation alone.

Cite this article: Bone Joint J 2023;105-B(5):481–486.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 110 - 114
1 Mar 2024
Yee AHF Chan VWK Fu H Chan P Chiu KY

Aims

The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in total hip arthroplasty (THA) at a minimum follow-up of 20 years.

Methods

We reviewed the results of 165 THAs using the Omnifit HA system in 138 patients, performed between August 1993 and December 1999. The mean age of the patients at the time of surgery was 46 years (20 to 77). Avascular necrosis was the most common indication for THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (20 to 31). At 20 and 25 years, 113 THAs in 91 patients and 63 THAs in 55 patients were available for review, respectively, while others died or were lost to follow-up. Kaplan-Meier analysis was performed to evaluate the survival of the stem. Radiographs were reviewed regularly, and the stability of the stem was evaluated using the Engh classification.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1393 - 1398
1 Dec 2024
Morris WZ Haider S Hinds ST Podeszwa D Ellis H Osborne L Anable N Sucato D

Aims

There has been limited literature regarding outcomes of acetabular rim syndrome (ARS) with persistent acetabular os in the setting of acetabular dysplasia. The purpose of this study was to characterize a cohort of adolescent and young adult patients with ARS with persistent os and compare their radiological and clinical outcomes to patients with acetabular dysplasia without an os.

Methods

We reviewed a prospective database of patients undergoing periacetabular osteotomy (PAO) for symptomatic acetabular dysplasia between January 1999 and December 2021 to identify hips with preoperative os acetabuli, defined as a closed triradiate cartilage but persistence of a superolateral os acetabulum. A total of 14 hips in 12 patients with persistent os acetabuli (ARS cohort) were compared to 50 randomly selected ‘control’ hips without persistent os acetabuli. Preoperative and postoperative radiographs were measured for markers of dysplasia: lateral centre-edge angle, anterior centre-edge angle, acetabular inclination, and migration index. Union of the os was determined in patients with ≥ six months’ follow-up. Patient-reported outcome measures (PROMs) included the University of California, Los Angeles (UCLA) activity score and modified Harris Hip Score (mHHS, maximum score 80) completed at one year postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 723 - 728
1 Jul 2023
Raj RD Fontalis A Grandhi TSP Kim WJ Gabr A Haddad FS

There is a disparity in sport-related injuries between sexes, with females sustaining non-contact musculoskeletal injuries at a higher rate. Anterior cruciate ligament ruptures are between two and eight times more common than in males, and females also have a higher incidence of ankle sprains, patellofemoral pain, and bone stress injuries. The sequelae of such injuries can be devastating to an athlete, resulting in time out of sport, surgery, and the early onset of osteoarthritis. It is important to identify the causes of this disparity and introduce prevention programmes to reduce the incidence of these injuries. A natural difference reflects the effect of reproductive hormones in females, which have receptors in certain musculoskeletal tissues. Relaxin increases ligamentous laxity. Oestrogen decreases the synthesis of collagen and progesterone does the opposite. Insufficient diet and intensive training can lead to menstrual irregularities, which are common in female athletes and result in injury, whereas oral contraception may have a protective effect against certain injuries. It is important for coaches, physiotherapists, nutritionists, doctors, and athletes to be aware of these issues and to implement preventive measures. This annotation explores the relationship between the menstrual cycle and orthopaedic sports injuries in pre-menopausal females, and proposes recommendations to mitigate the risk of sustaining these injuries.

Cite this article: Bone Joint J 2023;105-B(7):723–728.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1039 - 1043
1 Oct 2024
Luo TD Kayani B Magan A Haddad FS

The subject of noise in the operating theatre was recognized as early as 1972 and has been compared to noise levels on a busy highway. While noise-induced hearing loss in orthopaedic surgery specifically has been recognized as early as the 1990s, it remains poorly studied. As a result, there has been renewed focus in this occupational hazard. Noise level is typically measured in decibels (dB), whereas noise adjusted for human perception uses A-weighted sound levels and is expressed in dBA. Mean operating theatre noise levels range between 51 and 75 dBA, with peak levels between 80 and 119 dBA. The greatest sources of noise emanate from powered surgical instruments, which can exceed levels as high as 140 dBA. Newer technology, such as robotic-assisted systems, contribute a potential new source of noise. This article is a narrative review of the deleterious effects of prolonged noise exposure, including noise-induced hearing loss in the operating theatre team and the patient, intraoperative miscommunication, and increased cognitive load and stress, all of which impact the surgical team’s overall performance. Interventions to mitigate the effects of noise exposure include the use of quieter surgical equipment, the implementation of sound-absorbing personal protective equipment, or changes in communication protocols. Future research endeavours should use advanced research methods and embrace technological innovations to proactively mitigate the effects of operating theatre noise.

Cite this article: Bone Joint J 2024;106-B(10):1039–1043.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1306 - 1311
1 Nov 2024
Watts AC McDaid C Hewitt C

Aims

A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement.

Methods

A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 98 - 104
1 May 2024
Mallett KE Guarin Perez SF Taunton MJ Sierra RJ

Aims

Dual-mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a rare complication of DM that is believed to have decreased with contemporary implants. This study aimed to report incidence, treatment, and outcomes of contemporary DM IPD.

Methods

A total of 1,453 DM components were implanted at a single academic institution between January 2010 and December 2021: 695 in primary and 758 in revision THA. Of these, 49 presented with a dislocation of the large DM head and five presented with an IPD. At the time of closed reduction of the large DM dislocation, six additional IPDs occurred. The mean age was 64 years (SD 9.6), 54.5% were female (n = 6), and mean follow-up was 4.2 years (SD 1.8). Of the 11 IPDs, seven had a history of instability, five had abductor insufficiency, four had prior lumbar fusion, and two were conversions for failed fracture management.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 261 - 268
1 Mar 2023
Ruhr M Huber G Niki Y Lohner L Ondruschka B Morlock MM

Aims

The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure.

Methods

Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 751 - 759
1 Jul 2023
Lu V Andronic O Zhang JZ Khanduja V

Aims

Hip arthroscopy (HA) has become the treatment of choice for femoroacetabular impingement (FAI). However, less favourable outcomes following arthroscopic surgery are expected in patients with severe chondral lesions. The aim of this study was to assess the outcomes of HA in patients with FAI and associated chondral lesions, classified according to the Outerbridge system.

Methods

A systematic search was performed on four databases. Studies which involved HA as the primary management of FAI and reported on chondral lesions as classified according to the Outerbridge classification were included. The study was registered on PROSPERO. Demographic data, patient-reported outcome measures (PROMs), complications, and rates of conversion to total hip arthroplasty (THA) were collected.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1061 - 1065
1 Aug 2010
Cho W Cho SK Wu C

There are three basic concepts that are important to the biomechanics of pedicle screw-based instrumentation. First, the outer diameter of the screw determines pullout strength, while the inner diameter determines fatigue strength. Secondly, when inserting a pedicle screw, the dorsal cortex of the spine should not be violated and the screws on each side should converge and be of good length. Thirdly, fixation can be augmented in cases of severe osteoporosis or revision. A trajectory parallel or caudal to the superior endplate can minimise breakage of the screw from repeated axial loading. Straight insertion of the pedicle screw in the mid-sagittal plane provides the strongest stability. Rotational stability can be improved by adding transverse connectors. The indications for their use include anterior column instability, and the correction of rotational deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1610 - 1616
1 Dec 2011
Pegg E Pandit H Gill HS Keys GW Svard UGC O’Connor JJ Murray DW

Since the Oxford knee was first used unicompartmentally in 1982, a small number of bearings have fractured. Of 14 retrieved bearings, we examined ten samples with known durations in situ (four Phase 1, four Phase 2 and two Phase 3). Evidence of impingement and associated abnormally high wear (> 0.05 mm per year) as well as oxidation was observed in all bearings. In four samples the fracture was associated with the posterior radio-opaque wire. Fracture surfaces indicated fatigue failure, and scanning electron microscopy suggested that the crack initiated in the thinnest region. The estimated incidence of fracture was 3.20% for Phase 1, 0.74% for Phase 2, 0.35% for Phase 3, and 0% for Phase 3 without the posterior marker wire. The important aetiological factors for bearing fracture are impingement leading to high wear, oxidation, and the posterior marker wire. With improved surgical technique, impingement and high wear should be prevented and modern polyethylene may reduce the oxidation risk. A posterior marker wire is no longer used in the polyethylene meniscus. Therefore, the rate of fracture, which is now very low, should be reduced to a negligible level


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 742 - 745
1 Jun 2007
Harvie P Haroon M Henderson N El-Guindi M

We describe three cases of fracture of the titanium JRI-Furlong hydroxyapatite-ceramic (HAC)-coated femoral component. We have examined previous case reports of failure of this stem and conclude that fracture may occur in two places, namely at the neck-shoulder junction and at the conical-distal cylindrical junction. These breakages are the result of fatigue in a metallurgically-proven normal femoral component. All the cases of failure of the femoral component have occurred in patients with a body mass index of more than 25 in whom a small component, either size 9 or 10, had been used. In patients with a body mass index above normal size 9 components should be avoided and the femoral canal should be reamed sufficiently to accept a large femoral component to ensure that there is adequate metaphyseal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 215 - 221
1 Feb 2007
Krieg AH Hefti F

We evaluated 31 patients who were treated with a non-vascularised fibular graft after resection of primary musculoskeletal tumours, with a median follow-up of 5.6 years (3 to 26.7 years). Primary union was achieved in 89% (41 of 46) of the grafts in a median period of 24 weeks. All 25 grafts in 18 patients without additional chemotheraphy and/or radiotherapy achieved primary union, compared with 16 of the 21 grafts (76%; 13 patients) with additional therapy (p = 0.017). Radiographs showed an increase in diameter in 70% (59) of the grafts. There were seven fatigue fractures in six patients, but only two needed treatment. Non-vascularised fibular transfer is a simpler, less expensive and a shorter procedure than the use of vascularised grafts and allows remodelling of the fibula at the donor site. It is a biological reconstruction with good long-term results, and a relatively low donor site complication rate of 16%


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 31 - 37
1 Jan 2013
Zywiel MG Brandt J Overgaard CB Cheung AC Turgeon TR Syed KA

Symptomatic cobalt toxicity from a failed total hip replacement is a rare but devastating complication. It has been reported following revision of fractured ceramic components, as well as in patients with failed metal-on-metal articulations. Potential clinical findings include fatigue, weakness, hypothyroidism, cardiomyopathy, polycythaemia, visual and hearing impairment, cognitive dysfunction, and neuropathy. We report a case of an otherwise healthy 46-year-old patient, who developed progressively worsening symptoms of cobalt toxicity beginning approximately six months following synovectomy and revision of a fractured ceramic-on-ceramic total hip replacement to a metal-on-polyethylene bearing. The whole blood cobalt levels peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy. Implant retrieval analysis confirmed a loss of 28.3 g mass of the cobalt–chromium femoral head as a result of severe abrasive wear by ceramic particles embedded in the revision polyethylene liner. Autopsy findings were consistent with heavy metal-induced cardiomyopathy. We recommend using new ceramics at revision to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components. Cite this article: Bone Joint J 2013;95-B:31–7


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 580 - 581
1 Jul 1991
Ritter M Eizember L Keating E Faris P

We used the stainless steel cable grip system described by Dall and Miles in 1983 to fix trochanters in 40 hips after total arthroplasty with trochanteric osteotomy. The cable broke in 32.5% of the hips; the trochanter failed to unite in 37.5%. Significantly more cables broke when placed inside the femoral canal than when the cable was placed round the femoral shaft (58% as against 9.5%, difference p less than 0.01). The high incidence of breakage may have resulted from contact between the stainless steel cable and the titanium prosthesis, from the acute angulation, or because of the lower fatigue strength of stainless steel. Better results have been obtained using cables with a higher fatigue strength, passed outside the proximal femur


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1561 - 1567
1 Nov 2005
Janssen D Aquarius R Stolk J Verdonschot N

The Capital Hip implant was a Charnley-based system which included a flanged and a roundback stem, both of which were available in stainless steel and titanium. The system was withdrawn from the market because of its inferior performance. However, all four of the designs did not produce poor rates of survival. Using a simulated-based, finite-element analysis, we have analysed the Capital Hip system. Our aim was to investigate whether our simulation was able to detect differences which could account for the varying survival between the Capital Hip designs, thereby further validating the simulation. We created finite-element models of reconstructions with the flanged and roundback Capital Hips. A loading history was applied representing normal walking and stair-climbing, while we monitored the formation of fatigue cracks in the cement. Corresponding to the clinical findings, our simulation was able to detect the negative effects of the titanium material and the flanged design in the Capital Hip system. Although improvements could be made by including the effect of the roughness of the surface of the stem, our study increased the value of the model as a predictive tool for determining failure of an implant


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 911 - 914
1 Aug 2022
Prijs J Liao Z Ashkani-Esfahani S Olczak J Gordon M Jayakumar P Jutte PC Jaarsma RL IJpma FFA Doornberg JN

Artificial intelligence (AI) is, in essence, the concept of ‘computer thinking’, encompassing methods that train computers to perform and learn from executing certain tasks, called machine learning, and methods to build intricate computer models that both learn and adapt, called complex neural networks. Computer vision is a function of AI by which machine learning and complex neural networks can be applied to enable computers to capture, analyze, and interpret information from clinical images and visual inputs. This annotation summarizes key considerations and future perspectives concerning computer vision, questioning the need for this technology (the ‘why’), the current applications (the ‘what’), and the approach to unlocking its full potential (the ‘how’).

Cite this article: Bone Joint J 2022;104-B(8):911–914.