Clinical, haematological or economic benefits of post-operative blood salvage with
We prospectively audited 79 patients undergoing primary knee or hip arthroplasty (38 knees, 41 hips) and found that 66% (58% of knees, 73% of hips) had at least one unit of blood transfused postoperatively, with a mean transfusion requirement of 1.3 units per patient (1.1 for knees, 0 to 6; 1.5 for hips, 0 to 4). We then established a new protocol for postoperative blood transfusion. This requires the calculation of the maximum allowable blood loss (MABL) that each individual patient can safely lose based upon their weight and preoperative haematocrit. The total blood loss up to this volume is replaced with colloid. When a patient’s total blood loss reaches their MABL their haematocrit is measured at the bedside using the Microspin system (Bayer plc, Newbury, UK). If their haematocrit is low (<
0.30 for men, <
0.27 for women), blood is transfused. As a safety net all patients have their haemoglobin formally checked on days 1, 2, and 3 after surgery and have a transfusion if the haemoglobin levels are less than 8.5 g/dl. We conducted a further audit of 82 patients (35 knees, 47 hips) after the introduction of this protocol. Under the new protocol only 24% of patients required blood (11% of knees, 34% of hips) with a mean transfusion requirement of 0.56 units per patient (0.26 for knees, 0 to 4; 0.79 for hips, 0 to 4). The use of clinical audit and the introduction of strict guidelines for transfusion can change transfusion practice and result in improved patient care. Our transfusion protocol is a simple and effective method of keeping transfusion to a minimum and is particularly useful in departments which do not have the facility to use
Using a computer-based quality assurance program, we analysed peri-operative data on 160 patients undergoing one-stage bilateral hip or knee arthroplasties under regional anaesthesia with routine anaesthetic monitoring and only using peripheral intravenous access for peri-operative safety. We monitored defined intra-operative adverse events such as hypotension, myocardial ischaemia, arrhythmias, hypovolaemia, hypertension and early post-operative complications. We also determined post-operative hip and knee function, and patient satisfaction with different aspects of the anaesthetic management. Those patients undergoing one-stage bilateral arthroplasties were matched according to a cross-stratification which used three variables (American Society of Anesthesiologists’ physical status scoring system, age and joint replaced) to patients undergoing unilateral hip or knee arthroplasties. Serious intra-operative adverse events were, with the exception of intra-operative hypotension, very infrequent in patients undergoing bilateral (nine adverse events) as well as unilateral arthroplasties (five adverse events). Early post-operative complications were also infrequent in both groups. However, the risks of receiving a heterologous blood transfusion (odds ratio 2.5; 95% confidence interval (CI) 1.3 to 5.0, estimated by exact conditional logistic regression) or vasoactive drugs (odds ratio 3.9; 95% CI 2.0 to 7.8) were significantly greater for patients undergoing bilateral operations. Patient satisfaction with anaesthesia was high; all patients who underwent the one-stage bilateral operation would choose the same anaesthetic technique again.