Of 4,617 babies born in Coventry in 1986, a total of 448 (9.7%) had either clinical abnormality of the hip or at risk factors for
We used ultrasound to investigate the anatomy and stability of the hip during the phase of joint stabilisation after closed reduction of unilateral late
Ultrasound was used to observe the entire course of spontaneous reduction of
We describe two cases of fracture of Corin Taper-Fit stems used for cement-in-cement revision of congenital dysplasia of the hip. Both prostheses were implanted in patients in their 50s, with high offsets (+7.5 mm and +3.5 mm), one with a large diameter (48 mm) head and one with a constrained acetabular component. Fracture of the stems took place at nine months and three years post-operatively following low-demand activity. Both fractures occurred at the most medial of the two stem introducer holes in the neck of the prosthesis, a design feature that is unique to the Taper-Fit stem. We would urge caution in the use of these particular stems for cement-in-cement revisions.
Sixty-nine hips in 62 patients were treated by the Pavlik harness for congenital dislocation. Ultrasonography showed three degrees of residual head displacement when the harness was first applied. In type A, the femoral head showed contact with the inner posterior wall of the acetabulum. In type B, it contacted the posterior margin of the socket, with its centre at or anterior to the acetabular rim. In type C, the femoral head was displaced outside the socket, with its centre posterior to the acetabular rim. All 51 hips with type A displacement remained reduced. Of nine hips of type B, five were reduced, but the other four were not. None of the nine hips with type C dislocation became reduced with continued use of the harness. The Pavlik harness is indicated for type A and some type B dislocations, but the latter need daily ultrasound monitoring, with a change in method of treatment if type C displacement appears or if the hip is not reduced within one or two weeks. Treatment by Pavlik harness is not indicated in hips with type C dislocations.
We describe a simple, quick ultrasound screening test for
We report the preliminary results of a continuing prospective evaluation of a screening programme for congenital dislocation of the hip (CDH) which uses ultrasound imaging to provide delayed selective screening to complement neonatal clinical screening. Of 26,952 births in the Southampton district, 1894 infants were referred for secondary screening because of a clinical abnormality or the presence of a predetermined risk category for
The aim of this study was to report the long-term follow-up of cemented short Exeter femoral components when used in primary total hip arthroplasty (THA). We included all primary 394 THAs with a cemented short Exeter femoral component (≤ 125 mm) used in our tertiary referral centre between October 1993 and December 2021. A total of 83 patients (21%) were male. The median age of the patients at the time of surgery was 42 years (interquartile range (IQR) 30 to 55). The main indication for THA was a childhood hip disease (202; 51%). The median follow-up was 6.7 years (IQR 3.1 to 11.0). Kaplan-Meier survival analyses were performed to determine the rates of survival with femoral revision for any indication, for septic loosening, for fracture of the femoral component and for aseptic loosening as endpoints. The indications for revision were evaluated. Fractures of the femoral component were described in detail.Aims
Methods
Adolescent idiopathic scoliosis (AIS), defined by an age at presentation of 11 to 18 years, has a prevalence of 0.47% and accounts for approximately 90% of all cases of idiopathic scoliosis. Despite decades of research, the exact aetiology of AIS remains unknown. It is becoming evident that it is the result of a complex interplay of genetic, internal, and environmental factors. It has been hypothesized that genetic variants act as the initial trigger that allow epigenetic factors to propagate AIS, which could also explain the wide phenotypic variation in the presentation of the disorder. A better understanding of the underlying aetiological mechanisms could help to establish the diagnosis earlier and allow a more accurate prediction of deformity progression. This, in turn, would prompt imaging and therapeutic intervention at the appropriate time, thereby achieving the best clinical outcome for this group of patients. Cite this article:
We describe the results of a policy of highly selective splintage for
This study, using a surgeon-maintained database, aimed to explore the risk factors for surgery-related complications in patients undergoing primary cervical spine surgery for degenerative diseases. We studied 5,015 patients with degenerative cervical diseases who underwent primary cervical spine surgery from 2012 to 2018. We investigated the effects of diseases, surgical procedures, and patient demographics on surgery-related complications. As subcategories, the presence of cervical kyphosis ≥ 10°, the presence of ossification of the posterior longitudinal ligament (OPLL) with a canal-occupying ratio ≥ 50%, and foraminotomy were selected. The surgery-related complications examined were postoperative upper limb palsy (ULP) with a manual muscle test (MMT) grade of 0 to 2 or a reduction of two grade or more in the MMT, neurological deficit except ULP, dural tear, dural leakage, surgical-site infection (SSI), and postoperative haematoma. Multivariate logistic regression analysis was performed.Aims
Methods
We analysed one surgeon’s attempt to reconstruct the hip in 66 patients (84 hips) with chronic dislocation and to restore the height of the centre of rotation above the transverse teardrop line, the bodyweight lever arm, the abductor lever arm, and the abductor angle to normal. The outcome was assessed using a patient profile at 0, 10 and 20 years, a clinical assessment of pain, mobility and the range of active movement. We measured the work done by active movement against gravity, radiological signs of loosening, migration and subsidence, and the need for revision. We used survival at ten years and revision as the endpoint. The incidence of complications was higher than in arthroplasty for primary osteoarthritis of the hip, but the outcome was considered satisfactory. The advantages of a flanged cemented socket were demonstrated. A custom-made, laterally reduced, Charnley extra small
We have undertaken routine ultrasound screening for neonatal hip instability in Coventry since June 1989. Of the 14,050 babies scanned during the first three years, 847 (6%) had ultrasound abnormalities. A grading system, based on the percentage of femoral head coverage, is presented. The proportion of abnormal hips decreased gradually so that by nine weeks, 90% had normal ultrasound appearances. Abnormality was more common in babies with a family history of
We reviewed the serial radiographs of 54 hips in 47 children treated by closed reduction for congenital dislocation of the hip and followed to at least 14 years of age, to determine the causes of acetabular dysplasia. We excluded hips with femoral head deformity or residual subluxation and compared the results with those from a control series of unaffected hips of patients with unilateral
Various surgical techniques have been described for total hip arthroplasty (THA) in patients with Crowe type III dislocated hips, who have a large acetabular bone defect. The aim of this study was to evaluate the long-term clinical results of patients in whom anatomical reconstruction of the acetabulum was performed using a cemented acetabular component and autologous bone graft from the femoral neck. A total of 22 patients with Crowe type III dislocated hips underwent 28 THAs using bone graft from the femoral neck between 1979 and 2000. A Charnley cemented acetabular component was placed at the level of the true acetabulum after preparation with bone grafting. All patients were female with a mean age at the time of surgery of 54 years (35 to 68). A total of 18 patients (21 THAs) were followed for a mean of 27.2 years (20 to 33) after the operation.Aims
Methods
The purpose of this study was to analyze the incidence of the different ultrasound phenotypes of developmental dysplasia of the hip (DDH), and to determine their subsequent course. A consecutive series of 28 092 neonates was screened and classified according to the Graf method as part of a nationwide surveillance programme, and then followed prospectively. Abnormal hips were followed until they became normal (Graf type I). Type IIb hips and higher grades were treated by abduction in a Tübinger orthosis until normal. Dislocated hips underwent closed or open reduction.Aims
Patients and Methods
Since September 1964, neonates born in New Plymouth have undergone clinical examination for instability of the hip in a structured clinical screening programme. Of the 41 563 babies born during this period, 1639 were diagnosed as having unstable hips and 663 (1.6%) with persisting instability were splinted, five of which failed. Also, three unsplinted hips progressed to congenital dislocation, and there were four late-presenting (walking) cases, giving an overall failure rate of 0.29 per 1000 live births, with an incidence of late-walking congenital dislocation of the hip of 0.1 per 1000 live births. This study confirms that clinical screening for neonatal instability of the hip by experienced orthopaedic examiners significantly reduces the incidence of late-presenting (walking) congenital dislocation of the hip.