Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1731 - 1735
1 Nov 2021
Iobst CA Frost MW Rölfing JD Rahbek O Bafor A Duncan M Kold S

Aims. Limb-lengthening nails have largely replaced external fixation in limb-lengthening and reconstructive surgery. However, the adverse events and high prevalence of radiological changes recently noted with the STRYDE lengthening nail have raised concerns about the use of internal lengthening nails. The aim of this study was to compare the prevalence of radiological bone abnormalities between STRYDE, PRECICE, and FITBONE nails prior to nail removal. Methods. This was a retrospective case series from three centres. Patients were included if they had either of the three limb-lengthening nails (STYDE, PRECICE, or FITBONE) removed. Standard orthogonal radiographs immediately prior to nail removal were examined for bone abnormalities at the junction of the telescoping nail parts. Results. In total, 306 patients (168 male, 138 female) had 366 limb-lengthening nails removed. The mean time from nail insertion to radiological evaluation was 434 days (36 to 3,015). Overall, 77% of STRYDE nails (20/26) had bone abnormalities at the interface compared with only 2% of FITBONE (4/242) and 1% of PRECICE nails (1/98; p < 0.001). Focal osteolysis in conjunction with periosteal reaction at the telescoping interface was only observed in STRYDE nails. Conclusion. Bone abnormalities at the interface of telescoping nail parts were seen in the majority of STRYDE nails, but only very rarely with FITBONE or PRECICE nails. We conclude that the low prevalence of radiological changes at the junctional interface of 242 FITBONE and 98 PRECICE nails at the time of nail removal does not warrant clinical concerns. Cite this article: Bone Joint J 2021;103-B(11):1731–1735


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 283 - 288
1 Feb 2017
Hughes A Heidari N Mitchell S Livingstone J Jackson M Atkins R Monsell F

Aims. Computer hexapod assisted orthopaedic surgery (CHAOS), is a method to achieve the intra-operative correction of long bone deformities using a hexapod external fixator before definitive internal fixation with minimally invasive stabilisation techniques. The aims of this study were to determine the reliability of this method in a consecutive case series of patients undergoing femoral deformity correction, with a minimum six-month follow-up, to assess the complications and to define the ideal group of patients for whom this treatment is appropriate. Patients and Methods. The medical records and radiographs of all patients who underwent CHAOS for femoral deformity at our institution between 2005 and 2011 were retrospectively reviewed. Records were available for all 55 consecutive procedures undertaken in 49 patients with a mean age of 35.6 years (10.9 to 75.3) at the time of surgery. Results. Patients were assessed at a mean interval of 44 months (6 to 90) following surgery. The indications were broad; the most common were vitamin D resistant rickets (n = 10), growth plate arrest (n = 6) and post-traumatic deformity (n = 20). Multi-planar correction was required in 33 cases. A single level osteotomy was performed in 43 cases. Locking plates were used to stabilise the osteotomy in 33 cases and intramedullary nails in the remainder. Complications included two nonunions, one death, one below-knee deep vein thrombosis, one deep infection and one revision procedure due to initial under-correction. There were no neurovascular injuries or incidence of compartment syndrome. Conclusion. This is the largest reported series of femoral deformity corrections using the CHAOS technique. This series demonstrates that precise intra-operative realignment is possible with a hexapod external fixator prior to definitive stabilisation with contemporary internal fixation. This combination allows reproducible correction of complex femoral deformity from a wide variety of diagnoses and age range with a low complication rate. Cite this article: Bone Joint J 2017;99-B:283–8


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1168 - 1172
1 Jun 2021
Iliadis AD Wright J Stoddart MT Goodier WD Calder P

Aims

The STRYDE nail is an evolution of the PRECICE Intramedullary Limb Lengthening System, with unique features regarding its composition. It is designed for load bearing throughout treatment in order to improve patient experience and outcomes and allow for simultaneous bilateral lower limb lengthening. The literature published to date is limited regarding outcomes and potential problems. We report on our early experience and raise awareness for the potential of adverse effects from this device.

Methods

This is a retrospective review of prospective data collected on all patients treated in our institution using this implant. We report the demographics, nail accuracy, reliability, consolidation index, and cases where concerning clinical and radiological findings were encountered. There were 14 STRYDE nails implanted in nine patients (three male and six female) between June 2019 and September 2020. Mean age at surgery was 33 years (14 to 65). Five patients underwent bilateral lengthening (two femoral and three tibial) and four patients unilateral femoral lengthening for multiple aetiologies.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1545 - 1551
1 Nov 2017
Makki D Elgamal T Evans P Harvey D Jackson G Platt S

Aims

The aim of this paper was to present the clinical features of patients with musculoskeletal sources of methicillin-sensitive Staphylococcus aureus (MSSA) septicaemia.

Patients and Methods

A total of 137 patients presented with MSSA septicaemia between 2012 and 2015. The primary source of infection was musculoskeletal in 48 patients (35%). Musculoskeletal infection was considered the primary source of septicaemia when endocarditis and other obvious sources were excluded. All patients with an arthroplasty at the time were evaluated for any prosthetic involvement.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 292 - 299
1 Mar 2015
Karthik K Colegate-Stone T Dasgupta P Tavakkolizadeh A Sinha J

The use of robots in orthopaedic surgery is an emerging field that is gaining momentum. It has the potential for significant improvements in surgical planning, accuracy of component implantation and patient safety. Advocates of robot-assisted systems describe better patient outcomes through improved pre-operative planning and enhanced execution of surgery. However, costs, limited availability, a lack of evidence regarding the efficiency and safety of such systems and an absence of long-term high-impact studies have restricted the widespread implementation of these systems. We have reviewed the literature on the efficacy, safety and current understanding of the use of robotics in orthopaedics.

Cite this article: Bone Joint J 2015; 97-B:292–9.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 277 - 282
1 Feb 2015
Shetty RP Mathew M Smith J Morse LP Mehta JA Currie BJ

Little information is available about several important aspects of the treatment of melioidosis osteomyelitis and septic arthritis.

We undertook a retrospective review of 50 patients with these conditions in an attempt to determine the effect of location of the disease, type of surgical intervention and duration of antibiotic treatment on outcome, particularly complications and relapse.

We found that there was a 27.5% risk of osteomyelitis of the adjacent bone in patients with septic arthritis in the lower limb. Patients with septic arthritis and osteomyelitis of an adjacent bone were in hospital significantly longer (p = 0.001), needed more operations (p = 0.031) and had a significantly higher rate of complications and re-presentation (p = 0.048).

More than half the patients (61%), most particularly those with multifocal bone and joint involvement, and those with septic arthritis and osteomyelitis of an adjacent bone who were treated operatively, needed more visits to theatre.

Cite this article: Bone Joint J 2015;97-B:277–82.