Surgery is often delayed in patients who sustain a hip fracture and are treated with a total hip arthroplasty (THA), in order to await appropriate surgical expertise. There are established links between delay and poorer outcomes in all patients with a hip fracture, but there is little information about the impact of delay in the less frail patients who undergo THA. The aim of this study was to investigate the influence of delayed surgery on outcomes in these patients. A retrospective cohort study was undertaken using data from the Scottish Hip Fracture Audit between May 2016 and December 2020. Only patients undergoing THA were included, with categorization according to surgical treatment within 36 hours of admission (≤ 36 hours = ‘acute group’ vs > 36 hours = ‘delayed’ group). Those with delays due to being “medically unfit” were excluded. The primary outcome measure was 30-day survival. Costs were estimated in relation to the differences in the lengths of stay.Aims
Methods
Echocardiography is commonly used in hip fracture patients to evaluate perioperative cardiac risk. However, echocardiography that delays surgical repair may be harmful. The objective of this study was to compare surgical wait times, mortality, length of stay (LOS), and healthcare costs for similar hip fracture patients evaluated with and without preoperative echocardiograms. A population-based, matched cohort study of all hip fracture patients (aged over 45 years) in Ontario, Canada between 2009 and 2014 was conducted. The primary exposure was preoperative echocardiography (occurring between hospital admission and surgery). Mortality rates, surgical wait times, postoperative LOS, and medical costs (expressed as 2013$ CAN) up to one year postoperatively were assessed after propensity-score matching.Aims
Methods
Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees. A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed.Aims
Methods
Patient engagement in adaptive health behaviours and interactions with their healthcare ecosystem can be measured using self-reported instruments, such as the Patient Activation Measure (PAM-13) and the Effective Consumer Scale (ECS-17). Few studies have investigated the influence of patient engagement on limitations (patient-reported outcome measures (PROMs)) and patient-reported experience measures (PREMs). First, we assessed whether patient engagement (PAM-13, ECS-17) within two to four weeks of an upper limb fracture was associated with limitations (the Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH), and Patient-Reported Outcome Measurement Information System Upper Extremity Physical Function computer adaptive test (PROMIS UE PF) scores) measured six to nine months after fracture, accounting for demographic, clinical, and psychosocial factors. Secondly, we assessed the association between patient engagement and experience (numerical rating scale for satisfaction with care (NRS-C) and satisfaction with services (NRS-S) six to nine months after fracture. A total of 744 adults with an isolated fracture of the proximal humerus, elbow, or distal radius completed PROMs. Due to multicollinearity of patient engagement and psychosocial variables, we generated a single variable combining measures of engagement and psychosocial factors using factor analysis. We then performed multivariable analysis with p < 0.10 on bivariate analysis.Aims
Methods
The purpose of this study was to identify factors associated with limitations in function, measured by patient-reported outcome measures (PROMs), six to nine months after a proximal humeral fracture, from a range of demographic, injury, psychological, and social variables measured within a week and two to four weeks after injury. We enrolled 177 adult patients who sustained an isolated proximal humeral fracture into the study and invited them to complete PROMs at their initial outpatient visit within one week of injury, between two and four weeks, and between six to nine months after injury. There were 128 women and 49 men; the mean age was 66 years (Aims
Patients and Methods
To evaluate whether an ultra-low-dose CT protocol can diagnose
selected limb fractures as well as conventional CT (C-CT). We prospectively studied 40 consecutive patients with a limb
fracture in whom a CT scan was indicated. These were scanned using
an ultra-low-dose CT Reduced Effective Dose Using Computed Tomography
In Orthopaedic Injury (REDUCTION) protocol. Studies from 16 selected
cases were compared with 16 C-CT scans matched for age, gender and
type of fracture. Studies were assessed for diagnosis and image
quality. Descriptive and reliability statistics were calculated.
The total effective radiation dose for each scanned site was compared.Aims
Patients and Methods
The management of open lower limb fractures in the United Kingdom
has evolved over the last ten years with the introduction of major
trauma networks (MTNs), the publication of standards of care and
the wide acceptance of a combined orthopaedic and plastic surgical approach
to management. The aims of this study were to report recent changes
in outcome of open tibial fractures following the implementation
of these changes. Data on all patients with an open tibial fracture presenting
to a major trauma centre between 2011 and 2012 were collected prospectively.
The treatment and outcomes of the 65 Gustilo Anderson Grade III
B tibial fractures were compared with historical data from the same
unit. Aims
Patients and Methods
In order to achieve satisfactory reduction of
complex distal humeral fractures, adequate exposure of the fracture fragments
and the joint surface is required. Several surgical exposures have
been described for distal humeral fractures. We report our experience
using the anconeus pedicle olecranon flip osteotomy approach. This
involves detachment of the triceps along with a sliver of olecranon,
which retains the anconeus pedicle. We report the use of this approach
in ten patients (six male, four female) with a mean age of 38.4
years (28 to 51). The mean follow-up was 15 months (12 to 18) with
no loss to follow-up. Elbow function was graded using the Mayo Score.
The results were excellent in four patients, good in five and fair
in one patient. The mean time to both fracture and osteotomy union
was 10.6 weeks (8 to 12) and 7.1 weeks (6 to 8), respectively. We
found this approach gave reliably good exposure for these difficult
fractures enabling anatomical reduction and bicondylar plating without
complications. Cite this article:
The aim of this study was to report the pattern
of severe open diaphyseal tibial fractures sustained by military personnel,
and their orthopaedic–plastic surgical management. Cite this article:
There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (<
350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.
We have reviewed our experience in managing 11 patients who sustained an indirect sternal fracture in combination with an upper thoracic spinal injury between 2003 and 2006. These fractures have previously been described as ‘associated’ fractures, but since the upper thorax is an anatomical entity composed of the upper thoracic spine, ribs and sternum joined together, we feel that the term ‘fractures of the upper transthoracic cage’ is a better description. These injuries are a challenge because they are unusual and easily overlooked. They require a systematic clinical and radiological examination to identify both lesions. This high-energy trauma gives severe devastating concomitant injuries and CT with contrast and reconstruction is essential after resuscitation to confirm the presence of all the lesions. The injury level occurs principally at T4–T5 and at the manubriosternal joint. These unstable fractures need early posterior stabilisation and fusion or, if treated conservatively, a very close follow-up.
We created virtual three-dimensional reconstruction models from computed tomography scans obtained from patients with acetabular fractures. Virtual cylindrical implants were placed intraosseously in the anterior column, the posterior column and across the dome of the acetabulum. The maximum diameter which was entirely contained within the bone was determined for each position of the screw. In the same model, the cross-sectional diameters of the columns were measured and compared to the maximum diameter of the corresponding virtual implant. We found that the mean maximum diameter of virtual implant accommodated by the anterior columns was 6.4 mm and that the smallest diameter of the columns was larger than the maximum diameter of the equivalent virtual implant. This study suggests that the size of the screw used for percutaneous fixation of acetabular fractures should not be based solely on the measurement of cross-sectional diameter and that virtual three-dimensional reconstructions might be useful in pre-operative planning.
Between 1996 and 2003 six institutions in the United States and France contributed a consecutive series of 234 fractures of the femur in 229 children which were treated by titanium elastic nailing. Minor or major complications occurred in 80 fractures. Full information was available concerning 230 fractures, of which the outcome was excellent in 150 (65%), satisfactory in 57 (25%), and poor in 23 (10%). Poor outcomes were due to leg-length discrepancy in five fractures, unacceptable angulation in 17, and failure of fixation in one. There was a statistically significant relationship (p = 0.003) between age and outcome, and the odds ratio for poor outcome was 3.86 for children aged 11 years and older compared with those below this age. The difference between the weight of children with a poor outcome and those with an excellent or satisfactory outcome was statistically significant (54 kg