The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 167 - 169
1 Jan 1997
Zdravkovic V Sennwald GR

We assessed carpal collapse by measuring the capitate-radius (CR) distance on standard plain radiographs. This new method required validation of diagnostic accuracy, so we compared it with the method of Nattrass et al. 1. known as revised carpal height (RCH). We studied wrist radiographs from 16 normal subjects and 11 patients with unilateral Kienböck’s disease. We found that there was a significant difference in the left/right CR index between the normal wrists and those with Kienböck’s disease (p < 0.001). The use of left/right RCH index showed no significant difference (p = 0.30). Diagnostic accuracy was shown to be higher for the CR index using ROC curves. We then assessed 40 normal wrists and found the mean CR index to be 0.999 ± 0.034, and suggest that values less than 0.92 are abnormal. The CR index can be used for diagnosis in unilateral carpal collapse, and for monitoring progress where the condition is bilateral


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 571 - 576
1 Apr 2005
Savarino L Granchi D Cenni E Baldini N Greco M Giunti A

There is no diagnostic, non-invasive method for the early detection of loosening after total hip arthroplasty. In a pilot study, we have analysed two serum markers of bone remodelling, procollagen I C-terminal extension peptide (PICP) and cross-linked N-terminal telopeptide (NTx), as well as the diagnostic performance of NTx for the assessment of osteolysis. We recruited 21 patients with loosening (group I), 18 with a well-fixed prosthesis (group II) and 17 at the time of primary arthroplasty for osteoarthritis (OA) (group III). Internal normal reference ranges were obtained from 30 healthy subjects (group IV).

The serum PICP level was found to be significantly lower in patients with OA and those with loosening, when compared with those with stable implants, while the NTx level was significantly increased only in the group with loosening, suggesting that collagen degradation depended on the altered bone turnover induced by the implant. This hypothesis was reinforced by the finding that the values in the pre-surgery patients and stable subjects were comparable with the reference range of younger healthy subjects.

A high specificity and positive predictive value for NTx provided good diagnostic evidence of agreement between the test and the clinical and radiological evaluations. The NTx level could be used to indicate stability of the implant. However, further prospective, larger studies are necessary.