Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1048 - 1055
1 Aug 2020
Cox I Al Mouazzen L Bleibleh S Moldovan R Bintcliffe F Bache CE Thomas S

Aims. The Fassier Duval (FD) rod is a third-generation telescopic implant for children with osteogenesis imperfecta (OI). Threaded fixation enables proximal insertion without opening the knee or ankle joint. We have reviewed our combined two-centre experience with this implant. Methods. In total, 34 children with a mean age of five years (1 to 14) with severe OI have undergone rodding of 72 lower limb long bones (27 tibial, 45 femoral) for recurrent fractures with progressive deformity despite optimized bone health and bisphosphonate therapy. Data were collected prospectively, with 1.5 to 11 years follow-up. Results. A total of 24 patients (33%) required exchange of implants (14 femora and ten tibiae) including 11 rods bending with refracture. Four (5%) required reoperation with implant retention. Loss of proximal fixation in the femur and distal fixation in the tibia were common. Four patients developed coxa vara requiring surgical correction. In total, 13 patients experienced further fractures without rod bending; eight required implant revision. There was one deep infection. The five-year survival rate, with rod revision as the endpoint, was 63% (95% confidence interval (CI) 44% to 77%) for femoral rods, with a mean age at implantation of 4.8 years (1.3 to 14.8), and 64% (95% CI 36% to 82%) for tibial rods, with a mean age at implantation of 5.2 years (2.0 to 13.8). Conclusion. FD rods are easier to implant but do not improve on the revision rates reported for second generation T-piece rods. Proximal femoral fixation is problematic in younger children with a partially ossified greater trochanter. Distal tibial fixation typically fails after two years. Future generation implants should address proximal femoral and distal tibial fixation to avoid the majority of complications in this series. Cite this article: Bone Joint J 2020;102-B(8):1048–1055


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1428 - 1437
2 Aug 2021
Vogt B Roedl R Gosheger G Frommer A Laufer A Kleine-Koenig M Theil C Toporowski G

Aims

Temporary epiphysiodesis (ED) is commonly applied in children and adolescents to treat leg length discrepancies (LLDs) and tall stature. Traditional Blount staples or modern two-hole plates are used in clinical practice. However, they require accurate planning, precise surgical techniques, and attentive follow-up to achieve the desired outcome without complications. This study reports the results of ED using a novel rigid staple (RigidTack) incorporating safety, as well as technical and procedural success according to the idea, development, evaluation, assessment, long-term (IDEAL) study framework.

Methods

A cohort of 56 patients, including 45 unilateral EDs for LLD and 11 bilateral EDs for tall stature, were prospectively analyzed. ED was performed with 222 rigid staples with a mean follow-up of 24.4 months (8 to 49). Patients with a predicted LLD of ≥ 2 cm at skeletal maturity were included. Mean age at surgery was 12.1 years (8 to 14). Correction and complication rates including implant-associated problems, and secondary deformities as well as perioperative parameters, were recorded (IDEAL stage 2a). These results were compared to historical cohorts treated for correction of LLD with two-hole plates or Blount staples.