Advertisement for orthosearch.org.uk
Results 1 - 20 of 82
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 68 - 75
1 Jan 2005
Miedel R Ponzer S Törnkvist H Söderqvist A Tidermark J

We studied 217 patients with an unstable trochanteric or subtrochanteric fracture who had been randomly allocated to treatment by either internal fixation with a standard Gamma nail (SGN) or a Medoff sliding plate (MSP, biaxial dynamisation mode). Their mean age was 84 years (65 to 99) and they were reviewed at four and 12 months after surgery. Assessments of outcome included general complications, technical failures, revision surgery, activities of daily living (ADL), hip function (Charnley score) and the health-related quality of life (HRQOL, EQ-5D). The rate of technical failure in patients with unstable trochanteric fractures was 6.5% (6/93) (including intra-operative femoral fractures) in the SGN group and 5.2% (5/96) in the MSP group. In patients with subtrochanteric fractures, there were no failures in the SGN group (n = 16) and two in the MSP group (n = 12). In the SGN group, there were intra-operative femoral fractures in 2.8% (3/109) and no post-operative fractures. There was a reduced need for revision surgery in the SGN group compared with the MSP group (8.3%; 9/108; p = 0.072). The SGN group also showed a lower incidence of severe general complications (p < 0.05) and a trend towards a lower incidence of wound infections (p = 0.05). There were no differences between the groups regarding the outcome of ADL, hip function or the HRQOL. The reduction in the HRQOL (EQ-5D. index. score) was significant in both groups compared with that before the fracture (p < 0.005). Our findings indicate that the SGN showed good results in both trochanteric and subtrochanteric fractures. The limited number of intra-operative femoral fractures did not influence the outcome or the need for revision surgery. Moreover, the SGN group had a reduced number of serious general complications and wound infections compared with the MSP group. The MSP in the biaxial dynamisation mode had a low rate of failure in trochanteric fractures but an unacceptably high rate when used in the biaxial dynamisation mode in subtrochanteric fractures. The negative influence of an unstable trochanteric or subtrochanteric fracture on the quality of life was significant regardless of the surgical method


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1113 - 1119
1 Aug 2012
Gjertsen J Lie SA Vinje T Engesæter LB Hallan G Matre K Furnes O

Using data from the Norwegian Hip Fracture Register, 8639 cemented and 2477 uncemented primary hemiarthroplasties for displaced fractures of the femoral neck in patients aged > 70 years were included in a prospective observational study. A total of 218 re-operations were performed after cemented and 128 after uncemented procedures. Survival of the hemiarthroplasties was calculated using the Kaplan-Meier method and hazard rate ratios (HRR) for revision were calculated using Cox regression analyses. At five years the implant survival was 97% (95% confidence interval (CI) 97 to 97) for cemented and 91% (95% CI 87 to 94) for uncemented hemiarthroplasties. Uncemented hemiarthroplasties had a 2.1 times increased risk of revision compared with cemented prostheses (95% confidence interval 1.7 to 2.6, p < 0.001). The increased risk was mainly caused by revisions for peri-prosthetic fracture (HRR = 17), aseptic loosening (HRR = 17), haematoma formation (HRR = 5.3), superficial infection (HRR = 4.6) and dislocation (HRR = 1.8). More intra-operative complications, including intra-operative death, were reported for the cemented hemiarthroplasties. However, in a time-dependent analysis, the HRR for re-operation in both groups increased as follow-up increased. This study showed that the risk for revision was higher for uncemented than for cemented hemiarthroplasties


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 50 - 59
1 Jan 2017
Carli AV Negus JJ Haddad FS

Aims. Periprosthetic femoral fractures (PFF) following total hip arthroplasty (THA) are devastating complications that are associated with functional limitations and increased overall mortality. Although cementless implants have been associated with an increased risk of PFF, the precise contribution of implant geometry and design on the risk of both intra-operative and post-operative PFF remains poorly investigated. A systematic review was performed to aggregate all of the PFF literature with specific attention to the femoral implant used. Patients and Methods. A systematic search strategy of several journal databases and recent proceedings from the American Academy of Orthopaedic Surgeons was performed. Clinical articles were included for analysis if sufficient implant description was provided. All articles were reviewed by two reviewers. A review of fundamental investigations of implant load-to-failure was performed, with the intent of identifying similar conclusions from the clinical and fundamental literature. Results. In total 596 articles were initially identified, with 34 being eligible for analysis. Aggregate analysis of 1691 PFFs in 342 719 primary THAs revealed a significantly higher number of PFFs with cementless femoral implants (p < 0.001). Single-wedge and double-wedge (fit-and-fill) femoral implants were associated with a threefold increase in PFF rates (p < 0.001) compared with anatomical, fully coated and tapered/rounded stems. Within cemented stems, loaded-taper (Exeter) stems were associated with more PFFs than composite-beam (Charnley) stems (p = 0.004). Review of the fundamental literature revealed very few studies comparing cementless component designs. Conclusion. Very few studies within the PFF literature provide detailed implant information. Cementless implants, specifically those of single-wedge and double-wedge, have the highest PFF rates in the literature, with most investigations recommending against their use in older patients with osteoporotic bone. This review illustrates the need for registries and future PFF studies to record implant name and information for future analysis. Furthermore, future biomechanical investigations comparing modern implants are needed to clarify the precise contribution of implant design to PFF risk. Cite this article: Bone Joint J 2017;99-B(1 Supple A):50–9


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1422 - 1428
1 Oct 2010
van den Bekerom MPJ Hilverdink EF Sierevelt IN Reuling EMBP Schnater JM Bonke H Goslings JC van Dijk CN Raaymakers ELFB

The aim of this study was to analyse the functional outcome after a displaced intracapsular fracture of the femoral neck in active patients aged over 70 years without osteoarthritis or rheumatoid arthritis of the hip, randomised to receive either a hemiarthroplasty or a total hip replacement (THR). We studied 252 patients of whom 47 (19%) were men, with a mean age of 81.1 years (70.2 to 95.6). They were randomly allocated to be treated with either a cemented hemiarthroplasty (137 patients) or cemented THR (115 patients). At one- and five-year follow-up no differences were observed in the modified Harris hip score, revision rate of the prosthesis, local and general complications, or mortality. The intra-operative blood loss was lower in the hemiarthroplasty group (7% > 500 ml) than in the THR group (26% > 500 ml) and the duration of surgery was longer in the THR group (28% > 1.5 hours versus 12% > 1.5 hours). There were no dislocations of any bipolar hemiarthroplasty and eight dislocations of a THR during follow-up. Because of a higher intra-operative blood loss (p < 0.001), an increased duration of the operation (p < 0.001) and a higher number of early and late dislocations (p = 0.002), we do not recommend THR as the treatment of choice in patients aged ≥ 70 years with a fracture of the femoral neck in the absence of advanced radiological osteoarthritis or rheumatoid arthritis of the hip


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 250 - 254
1 Feb 2017
Tol MCJM van den Bekerom MPJ Sierevelt IN Hilverdink EF Raaymakers ELFB Goslings JC

Aims. Our aim was to analyse the long-term functional outcome of two forms of surgical treatment for active patients aged > 70 years with a displaced intracapsular fracture of the femoral neck. Patients were randomised to be treated with either a hemiarthroplasty or a total hip arthroplasty (THA). The outcome five years post-operatively for this cohort has previously been reported. We present the outcome at 12 years post-operatively. Patients and Methods. Initially 252 patients with a mean age of 81.1 years (70.2 to 95.6) were included, of whom 205 (81%) were women. A total of 137 were treated with a cemented hemiarthroplasty and 115 with a cemented THA. At long-term follow-up we analysed the modified Harris Hip Score (HHS), post-operative complications and intra-operative data of the patients who were still alive. Results . At a mean follow-up of 12 years (8.23 to 16.17, standard deviation 2.24), 50 patients (20%), 32 in the hemiarthroplasty group and 18 in the THA group, were still alive, of which 47 (94%) were women. There were no significant differences in the mean modified HHS (p = 0.85), mortality (p = 0.13), complications (p = 0.93) or rate of revision surgery (p = 1.0) between the two groups. Conclusion. In the treatment of active elderly patients with an intracapsular fracture of the hip there is no difference in the functional outcome between hemiarthroplasty and THA treatments at 12 years post-operatively. Cite this article: Bone Joint J 2017;99-B:250–4


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 94 - 99
1 Jan 2015
Grammatopoulos G Wilson HA Kendrick BJL Pulford EC Lippett J Deakin M Andrade AJ Kambouroglou G

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating. . This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK. Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen. . There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively. This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur. Cite this article: Bone Joint J 2015;97-B:94–9


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1053 - 1059
1 Aug 2006
Foss NB Kehlet H

Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss. We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin are necessary to avoid anaemia


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 86 - 94
1 Jan 2004
Schipper IB Steyerberg EW Castelein RM van der Heijden FHWM den Hoed PT Kerver AJH van Vugt AB

The proximal femoral nail (PFN) is a recently introduced intramedullary system, designed to improve treatment of unstable trochanteric fractures of the hip. In a multicentre prospective clinical study, the intra-operative use, complications and outcome of treatment using the PFN (n = 211) were compared with those using the gamma nail (GN) (n = 213). The intra-operative blood loss was lower with the PFN (220 ml v 287 ml, p = 0.001). Post-operatively, more lateral protrusion of the hip screws of the PFN (7.6%) was documented, compared with the gamma nail (1.6%, p = 0.02). Most local complications were related to suboptimal reduction of the fracture and/or positioning of the implant. Functional outcome and consolidation were equal for both implants. Generally, the results of treatment of unstable trochanteric fractures were comparable for the PFN and GN. The pitfalls and complications were similar, and mainly surgeon- or fracture-related, rather than implant-related


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1210 - 1217
1 Sep 2007
Peyser A Weil YA Brocke L Sela Y Mosheiff R Mattan Y Manor O Liebergall M

Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices. We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively. The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s t-test, p < 0.0001). The pain score and ability to bear weight were significantly better in the PCCP group at six weeks post-operatively. Analysis of the radiographs in a proportion of the patients revealed a reduced amount of medial displacement in the PCCP group (two patients, 4%) compared with the CHS group (10 patients, 18.9%); Fisher’s exact test, p < 0.02. The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 76 - 81
1 Jan 2005
Pajarinen J Lindahl J Michelsson O Savolainen V Hirvensalo E

We treated 108 patients with a pertrochanteric femoral fracture using either the dynamic hip screw or the proximal femoral nail in this prospective, randomised series. We compared walking ability before fracture, intra-operative variables and return to their residence. Patients treated with the proximal femoral nail (n = 42) had regained their pre-operative walking ability significantly (p = 0.04) more often by the four-month review than those treated with the dynamic hip screw (n = 41). Peri-operative or immediate post-operative measures of outcome did not differ between the groups, with the exception of operation time. The dynamic hip screw allowed a significantly greater compression of the fracture during the four-month follow-up, but consolidation of the fracture was comparable between the two groups. Two major losses of reduction were observed in each group, resulting in a total of four revision operations. Our results suggest that the use of the proximal femoral nail may allow a faster postoperative restoration of walking ability, when compared with the dynamic hip screw


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 958 - 963
1 Jul 2017
Mamarelis G Key S Snook J Aldam C

Aims

Hip hemiarthroplasty is a standard treatment for intracapsular proximal femoral fractures in the frail elderly. In this study we have explored the implications of early return to theatre, within 30 days, on patient outcome following hip hemiarthroplasty.

Patients and Methods

We retrospectively reviewed the hospital records of all hip hemiarthroplasties performed in our unit between January 2010 and January 2015. Demographic details, medical backround, details of the primary procedure, complications, subsequent procedures requiring return to theatre, re-admissions, discharge destination and death were collected.


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1399 - 1408
1 Oct 2017
Scott CEH MacDonald D Moran M White TO Patton JT Keating JF

Aims

To evaluate the outcomes of cemented total hip arthroplasty (THA) following a fracture of the acetabulum, with evaluation of risk factors and comparison with a patient group with no history of fracture.

Patients and Methods

Between 1992 and 2016, 49 patients (33 male) with mean age of 57 years (25 to 87) underwent cemented THA at a mean of 6.5 years (0.1 to 25) following acetabular fracture. A total of 38 had undergone surgical fixation and 11 had been treated non-operatively; 13 patients died at a mean of 10.2 years after THA (0.6 to 19). Patients were assessed pre-operatively, at one year and at final follow-up (mean 9.1 years, 0.5 to 23) using the Oxford Hip Score (OHS). Implant survivorship was assessed. An age and gender-matched cohort of THAs performed for non-traumatic osteoarthritis (OA) or avascular necrosis (AVN) (n = 98) were used to compare complications and patient-reported outcome measures (PROMs).


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1210 - 1215
1 Sep 2017
Parker MJ Cawley S

Aims

To compare the outcomes for trochanteric fractures treated with a sliding hip screw (SHS) or a cephalomedullary nail.

Patients and Methods

A total of 400 patients with a trochanteric hip fracture were randomised to receive a SHS or a cephalomedullary nail (Targon PFT). All surviving patients were followed up to one year from injury. Functional outcome was assessed by a research nurse blinded to the implant used.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 851 - 856
1 Jun 2016
Kwok IHY Silk ZM Quick TJ Sinisi M MacQuillan A Fox M

Aims

We aimed to identify the pattern of nerve injury associated with paediatric supracondylar fractures of the humerus.

Patients and Methods

Over a 17 year period, between 1996 and 2012, 166 children were referred to our specialist peripheral nerve injury unit. From examination of the medical records and radiographs were recorded the nature of the fracture, associated vascular and neurological injury, treatment provided and clinical course.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1125 - 1131
1 Sep 2017
Rickman M Varghese VD

In the time since Letournel popularised the surgical treatment of acetabular fractures, more than 25 years ago, there have been many changes within the field, related to patients, surgical technique, implants and post-operative care. However, the long-term outcomes appear largely unchanged. Does this represent stasis or have the advances been mitigated by other negative factors? In this article we have attempted to document the recent changes within the surgery of patients with a fracture involving the acetabulum, outline contemporary management, and identify the major problem areas where further research is most needed.

Cite this article: Bone Joint J 2017;99-B:1125–31


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 951 - 957
1 Jul 2017
Poole WEC Wilson DGG Guthrie HC Bellringer SF Freeman R Guryel E Nicol SG

Aims

Fractures of the distal femur can be challenging to manage and are on the increase in the elderly osteoporotic population. Management with casting or bracing can unacceptably limit a patient’s ability to bear weight, but historically, operative fixation has been associated with a high rate of re-operation. In this study, we describe the outcomes of fixation using modern implants within a strategy of early return to function.

Patients and Methods

All patients treated at our centre with lateral distal femoral locking plates (LDFLP) between 2009 and 2014 were identified. Fracture classification and operative information including weight-bearing status, rates of union, re-operation, failure of implants and mortality rate, were recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims

We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy.

Materials and Methods

Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 680 - 685
1 May 2017
Morris R Hossain M Evans A Pallister I

Aims

This study describes the use of the Masquelet technique to treat segmental tibial bone loss in 12 patients.

Patients and Methods

This retrospective case series reviewed 12 patients treated between 2010 and 2015 to determine their clinical outcome. Patients were mostly male with a mean age of 36 years (16 to 62). The outcomes recorded included union, infection and amputation. The mean follow-up was 675 days (403 to 952).


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 508 - 515
1 Apr 2017
Haefeli PC Marecek GS Keel MJB Siebenrock KA Tannast M

Aims

The aims of this study were to determine the cumulative ten-year survivorship of hips treated for acetabular fractures using surgical hip dislocation and to identify factors predictive of an unfavourable outcome.

Patients and Methods

We followed up 60 consecutive patients (61 hips; mean age 36.3 years, standard deviation (sd) 15) who underwent open reduction and internal fixation for a displaced fracture of the acetabulum (24 posterior wall, 18 transverse and posterior wall, ten transverse, and nine others) with a mean follow-up of 12.4 years (sd 3).


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 128 - 133
1 Jan 2017
Socci AR Casemyr NE Leslie MP Baumgaertner MR

Aims

The aim of this paper is to review the evidence relating to the anatomy of the proximal femur, the geometry of the fracture and the characteristics of implants and methods of fixation of intertrochanteric fractures of the hip.

Materials and Methods

Relevant papers were identified from appropriate clinical databases and a narrative review was undertaken.