Advertisement for orthosearch.org.uk
Results 1 - 20 of 43
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 844 - 846
1 Jun 2011
Sarasin SM Karthikeyan R Skinner P Nassef A Stockley I

Intrapelvic migration of the acetabular component of a total hip replacement, with severe acetabular destruction making reconstruction impossible, is very rare. We present a patient in whom the component was removed using a laparotomy and a transperitoneal approach with subsequent salvage using a saddle prosthesis and a total femoral replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 405 - 411
1 Mar 2012
Keel MJB Ecker TM Cullmann JL Bergmann M Bonel HM Büchler L Siebenrock KA Bastian JD

A new anterior intrapelvic approach for the surgical management of displaced acetabular fractures involving predominantly the anterior column and the quadrilateral plate is described. In order to establish five ‘windows’ for instrumentation, the extraperitoneal space is entered along the lateral border of the rectus abdominis muscle. This is the so-called ‘Pararectus’ approach. The feasibility of safe dissection and optimal instrumentation of the pelvis was assessed in five cadavers (ten hemipelves) before implementation in a series of 20 patients with a mean age of 59 years (17 to 90), of whom 17 were male. The clinical evaluation was undertaken between December 2009 and December 2010. The quality of reduction was assessed with post-operative CT scans and the occurrence of intra-operative complications was noted. In cadavers, sufficient extraperitoneal access and safe instrumentation of the pelvis were accomplished. In the patients, there was a statistically significant improvement in the reduction of the fracture (pre- versus post-operative: mean step-off 3.3 mm (. sd. 2.6) vs 0.1 mm (. sd. 0.3), p < 0.001; and mean gap 11.5 mm (. sd. 6.5) vs 0.8 mm (. sd. 1.3), p < 0.001). Lesions to the peritoneum were noted in two patients and minor vascular damage was noted in a further two patients. Multi-directional screw placement and various plate configurations were feasible in cadavers without significant retraction of soft tissues. In the treatment of acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach allowed anatomical restoration with minimal morbidity related to the surgical access


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1056 - 1058
1 Sep 2003
Farag AW Shohayeb KA

We describe a case of traumatic anterior dislocation of the hip in a 14-year-old boy with associated intrapelvic displacement of the femoral head and ipsilateral fractures of the shaft of the femur and greater trochanter. There was a delay in presentation of eight days. At operation the femoral head was reduced into the acetabulum after enlarging the obturator foramen by performing an osteotomy of the superior pubic ramus


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 25 - 27
1 Jan 1993
Grigoris P Roberts P McMinn D Villar R

We describe a simple, retroperitoneal approach for the removal of acetabular components that have migrated into the pelvis. The dense fibrous tissue layer which surrounds the implant protects the iliac vessels during removal of the cup by this method.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1037 - 1039
1 Nov 1998
Gupta A Kakkar A Chadha M Sathaye CB

A primary hydatid cyst in the pelvis is rare, and usually presents with pressure symptoms affecting the adjacent abdominal organs. We describe such a cyst which protruded through the sciatic notch and presented as a gluteal swelling with a foot drop due to compression of the lumbosacral nerve roots. Surgical excision and postoperative treatment with albendazole for six weeks were effective in controlling the disease and preventing recurrence.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 32 - 33
1 Jan 2007
Konangamparambath S Wilkinson JM Cleveland T Stockley I

Bleeding is a major complication of revision total hip replacement. We report a case where the inflated balloon of a urinary catheter was used to temporarily control intrapelvic bleeding from the superior gluteal artery, while definitive measures for endovascular embolisation were made


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 98 - 101
1 Jan 2008
Mannan K Altaf F Maniar S Tirabosco R Sinisi M Carlstedt T

We describe a case of sciatic endometriosis in a 25-year-old woman diagnosed by MRI and histology with no evidence of intrapelvic disease. The presentation, diagnosis and management of this rare condition are described. Early diagnosis and treatment are important to prevent irreversible damage to the sciatic nerve


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 97 - 103
1 Mar 2024
Baujard A Martinot P Demondion X Dartus J Faure PA Girard J Migaud H

Aims

Mechanical impingement of the iliopsoas (IP) tendon accounts for 2% to 6% of persistent postoperative pain after total hip arthroplasty (THA). The most common initiator is anterior acetabular component protrusion, where the anterior margin is not covered by anterior acetabular wall. A CT scan can be used to identify and measure this overhang; however, no threshold exists for determining symptomatic anterior IP impingement due to overhang. A case-control study was conducted in which CT scan measurements were used to define a threshold that differentiates patients with IP impingement from asymptomatic patients after THA.

Methods

We analyzed the CT scans of 622 patients (758 THAs) between May 2011 and May 2020. From this population, we identified 136 patients with symptoms suggestive of IP impingement. Among them, six were subsequently excluded: three because the diagnosis was refuted intraoperatively, and three because they had another obvious cause of impingement, leaving 130 hips (130 patients) in the study (impingement) group. They were matched to a control group of 138 asymptomatic hips (138 patients) after THA. The anterior acetabular component overhang was measured on an axial CT slice based on anatomical landmarks (orthogonal to the pelvic axis).


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 47 - 53
1 May 2024
Jones SA Parker J Horner M

Aims

The aims of this study were to determine the success of a reconstruction algorithm used in major acetabular bone loss, and to further define the indications for custom-made implants in major acetabular bone loss.

Methods

We reviewed a consecutive series of Paprosky type III acetabular defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical acetabular component. IIIB defects were planned to receive either a hemispherical acetabular component plus augments, a cup-cage reconstruction, or a custom-made implant. We used national digital health records and registry reports to identify any reoperation or re-revision procedure and Oxford Hip Score (OHS) for patient-reported outcomes. Implant survival was determined via Kaplan-Meier analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 865 - 870
1 Aug 2024
Broida SE Sullivan MH Rose PS Wenger DE Houdek MT

Aims

Venous tumour thrombus (VTT) is a rare finding in osteosarcoma. Despite the high rate of VTT in osteosarcoma of the pelvis, there are very few descriptions of VTT associated with extrapelvic primary osteosarcoma. We therefore sought to describe the prevalence and presenting features of VTT in osteosarcoma of both the pelvis and the limbs.

Methods

Records from a single institution were retrospectively reviewed for 308 patients with osteosarcoma of the pelvis or limb treated between January 2000 and December 2022. Primary lesions were located in an upper limb (n = 40), lower limb (n = 198), or pelvis (n = 70). Preoperative imaging and operative reports were reviewed to identify patients with thrombi in proximity to their primary lesion. Imaging and histopathology were used to determine presence of tumour within the thrombus.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 390 - 392
1 May 1992
Chalmers J Chalmers N

We describe a case in which chronic oedema of a leg was due to pressure on the external iliac vein from an intrapelvic rheumatoid cyst. Ultrasound and CT scanning gave the clues to diagnosis


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 98 - 104
1 May 2024
Mallett KE Guarin Perez SF Taunton MJ Sierra RJ

Aims

Dual-mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a rare complication of DM that is believed to have decreased with contemporary implants. This study aimed to report incidence, treatment, and outcomes of contemporary DM IPD.

Methods

A total of 1,453 DM components were implanted at a single academic institution between January 2010 and December 2021: 695 in primary and 758 in revision THA. Of these, 49 presented with a dislocation of the large DM head and five presented with an IPD. At the time of closed reduction of the large DM dislocation, six additional IPDs occurred. The mean age was 64 years (SD 9.6), 54.5% were female (n = 6), and mean follow-up was 4.2 years (SD 1.8). Of the 11 IPDs, seven had a history of instability, five had abductor insufficiency, four had prior lumbar fusion, and two were conversions for failed fracture management.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 66 - 73
1 May 2024
Chaudhry F Daud A Greenberg A Braunstein D Safir OA Gross AE Kuzyk PR

Aims

Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct.

Methods

We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on preoperative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed, with failure defined as revision of the cup-cage reconstruction.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1284 - 1291
1 Dec 2022
Rose PS

Tumours of the sacrum are difficult to manage. The sacrum provides the structural connection between the torso and lower half of the body and is subject to both axial and rotational forces. Thus, tumours or their treatment can compromise the stability of the spinopelvic junction. Additionally, nerves responsible for lower limb motor groups as well as bowel, bladder, and sexual function traverse or abut the sacrum. Preservation or sacrifice of these nerves in the treatment of sacral tumours has profound implications on the function and quality of life of the patient. This annotation will discuss current treatment protocols for sacral tumours.

Cite this article: Bone Joint J 2022;104-B(12):1284–1291.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 41 - 44
1 Jan 1984
Awbrey B Wright P Ekbladh L Doering M

It is not uncommon to observe bone cement in the pelvis on radiographs after total hip replacement, a finding which is generally considered to be benign. This paper reviews some catastrophic late complications from intrapelvic methylmethacrylate. We also describe a case of progressive, unbearable dyspareunia beginning three years after total hip replacement. A possible explanation of the pathophysiology is suggested. Recommendations for prevention, diagnosis, and treatment of these late complications are offered


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1110 - 1117
12 Oct 2022
Wessling M Gebert C Hakenes T Dudda M Hardes J Frieler S Jeys LM Hanusrichter Y

Aims

The aim of this study was to examine the implant accuracy of custom-made partial pelvis replacements (PPRs) in revision total hip arthroplasty (rTHA). Custom-made implants offer an option to achieve a reconstruction in cases with severe acetabular bone loss. By analyzing implant deviation in CT and radiograph imaging and correlating early clinical complications, we aimed to optimize the usage of custom-made implants.

Methods

A consecutive series of 45 (2014 to 2019) PPRs for Paprosky III defects at rTHA were analyzed comparing the preoperative planning CT scans used to manufacture the implants with postoperative CT scans and radiographs. The anteversion (AV), inclination (IC), deviation from the preoperatively planned implant position, and deviation of the centre of rotation (COR) were explored. Early postoperative complications were recorded, and factors for malpositioning were sought. The mean follow-up was 30 months (SD 19; 6 to 74), with four patients lost to follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 796 - 802
1 Sep 1999
Grimer RJ Carter SR Tillman RM Spooner D Mangham DC Kabukcuoglu Y

Over a 25-year period we have treated 36 patients with osteosarcoma of the pelvis. Of the tumours, 24 (67%) were primary osteosarcomas and 12 (33%) arose either after irradiation or in association with Paget’s disease. Six patients had a hindquarter amputation and 12 were treated by a limb-salvage procedure with intrapelvic excision. The five-year survival rate of all the patients with pelvic osteosarcoma was 18%, while for 17 treated by chemotherapy and surgery it was 41%. The prognosis for patients presenting with metastases or with secondary osteosarcoma was appalling and none survived after 29 months. No patient over the age of 50 years when seen initially survived for a year. Youth and a good response to chemotherapy along with complete surgical excision offer the best chance of cure


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1017 - 1024
1 Sep 2022
Morris WZ Justo PGS Williams KA Kim Y Millis MB Novais EN

Aims

The aims of this study were to characterize the incidence and risk factors associated with stress fractures following periacetabular osteotomy, and to determine their effect on osteotomy union.

Methods

We retrospectively reviewed all periacetabular osteotomies (PAOs) performed for developmental dysplasia of the hip (DDH) at one institution over a six-year period between 2012 and 2017. Perioperative factors were recorded, and included demographic and surgical data. Postoperatively, patients were followed for a minimum of one year with anteroposterior and false profile radiographs of the pelvis to monitor for evidence of stress fracture and union of osteotomies. We characterized the incidence and locations of stress fractures, and used univariate and multivariable analysis to identify factors predictive of stress fracture and the association of stress fracture on osteotomy union.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 550 - 555
1 May 2004
Gaine WJ Lim J Stephenson W Galasko CSB

A consecutive series of 85 patients with Duchenne’s muscular dystrophy who underwent spinal fusion over a period of 16 years was followed up with regard to the progression of the scoliosis and pelvic obliquity. Of 74 patients with adequate radiographic follow-up, 55 were instrumented with the Luque single-unit rod system and 19 with the Isola pedicle screw system; seven were instrumented to L3/4, 42 to L5, 15 to S1 and 10 to the pelvis with intrailiac rods. The mean period of follow-up was 49 months (SD 22) before and 47 months (SD 24) after operation. There was one peri-operative death and three cases of failure of hardware. The mean improvement in the Cobb angle was 26° and in pelvic obliquity, 9.2°. Fusion to L3/4 achieved a poorer correction of both curves while intrapelvic rods, achieved and maintained the best correction of pelvic obliquity. Fusion to S1 did not provide any benefit over more proximal fusion excluding the sacrum, with regard to correction and maintenance of both angles. The Isola system appeared to provide and maintain a slightly better correction of the Cobb angle


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 488 - 494
1 May 1993
Nene A Evans G Patrick J

We assessed the outcome after simultaneous multiple operations performed on 18 children with spastic diplegia, with emphasis on the changes in the physiological cost index (PCI) of walking. Fourteen patients had a measurable reduction at one year, but the more severely affected patients took up to two years to reach a new functional plateau. The level of the preoperative PCI allows prediction of the outcome of surgery in terms of reducing the effort of walking, or improving its appearance only. Intrapelvic intramuscular psoas tenotomy produced an improvement of hip flexion deformity in 15 of 17 patients without the loss of muscle power to initiate the swing phase. Fractional lengthening corrected hamstring tightness in 17 cases, and the mean popliteal angle was reduced from 63 degrees preoperatively to 30.2 degrees, with almost complete resolution of the fixed knee flexion deformity present in ten patients. Distal transfer of the rectus femoris, when it was shown to be contracting inappropriately, improved the knee flexion arc during walking from a mean of 28.3 degrees to 45.2 degrees