Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 541 - 548
1 May 2022
Zhang J Ng N Scott CEH Blyth MJG Haddad FS Macpherson GJ Patton JT Clement ND

Aims. This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA). Methods. Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta-­Analysis statement. Search terms included “robotic”, “unicompartmental”, “knee”, and “arthroplasty”. Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis. Results. A total of 179 articles were identified from initial screening, of which 14 articles satisfied the inclusion criteria and were included for analysis. The papers analyzed include one on learning curve, five on implant positioning, six on functional outcomes, five on complications, six on survivorship, and three on cost. The learning curve was six cases for operating time and zero for precision. There was consistent evidence of more precise implant positioning with MAKO RAUKA. Meta-analysis demonstrated lower overall complication rates associated with MAKO RAUKA (OR 2.18 (95% confidence interval (CI) 1.06 to 4.49); p = 0.040) but no difference in re-intervention, infection, Knee Society Score (KSS; mean difference 1.64 (95% CI -3.00 to 6.27); p = 0.490), or Western Ontario and McMaster Universities Arthritis Index (WOMAC) score (mean difference -0.58 (95% CI -3.55 to 2.38); p = 0.700). MAKO RAUKA was shown to be a cost-effective procedure, but this was directly related to volume. Conclusion. MAKO RAUKA was associated with improved precision of component positioning but was not associated with improved PROMs using the KSS and WOMAC scores. Future longer-term studies should report functional outcomes, potentially using scores with minimal ceiling effects and survival to assess whether the improved precision of MAKO RAUKA results in better outcomes. Cite this article: Bone Joint J 2022;104-B(5):541–548


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 407 - 413
1 Apr 2020
Vermue H Lambrechts J Tampere T Arnout N Auvinet E Victor J

The application of robotics in the operating theatre for knee arthroplasty remains controversial. As with all new technology, the introduction of new systems might be associated with a learning curve. However, guidelines on how to assess the introduction of robotics in the operating theatre are lacking. This systematic review aims to evaluate the current evidence on the learning curve of robot-assisted knee arthroplasty. An extensive literature search of PubMed, Medline, Embase, Web of Science, and Cochrane Library was conducted. Randomized controlled trials, comparative studies, and cohort studies were included. Outcomes assessed included: time required for surgery, stress levels of the surgical team, complications in regard to surgical experience level or time needed for surgery, size prediction of preoperative templating, and alignment according to the number of knee arthroplasties performed. A total of 11 studies met the inclusion criteria. Most were of medium to low quality. The operating time of robot-assisted total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) is associated with a learning curve of between six to 20 cases and six to 36 cases respectively. Surgical team stress levels show a learning curve of seven cases in TKA and six cases for UKA. Experience with the robotic systems did not influence implant positioning, preoperative planning, and postoperative complications. Robot-assisted TKA and UKA is associated with a learning curve regarding operating time and surgical team stress levels. Future evaluation of robotics in the operating theatre should include detailed measurement of the various aspects of the total operating time, including total robotic time and time needed for preoperative planning. The prior experience of the surgical team should also be evaluated and reported. Cite this article: Bone Joint J 2020;102-B(4):407–413


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1009 - 1020
1 Jun 2021
Ng N Gaston P Simpson PM Macpherson GJ Patton JT Clement ND

Aims. The aims of this systematic review were to assess the learning curve of semi-active robotic arm-assisted total hip arthroplasty (rTHA), and to compare the accuracy, patient-reported functional outcomes, complications, and survivorship between rTHA and manual total hip arthroplasty (mTHA). Methods. Searches of PubMed, Medline, and Google Scholar were performed in April 2020 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “hip”, and “arthroplasty”. The criteria for inclusion were published clinical research articles reporting the learning curve for rTHA (robotic arm-assisted only) and those comparing the implantation accuracy, functional outcomes, survivorship, or complications with mTHA. Results. There were 501 articles initially identified from databases and references. Following full text screening, 17 articles that satisfied the inclusion criteria were included. Four studies reported the learning curve of rTHA, 13 studies reported on implant positioning, five on functional outcomes, ten on complications, and four on survivorship. The meta-analysis showed a significantly greater number of cases of acetabular component placement in the safe zone compared with the mTHA group (95% confidence interval (CI) 4.10 to 7.94; p < 0.001) and that rTHA resulted in a significantly better Harris Hip Score compared to mTHA in the short- to mid-term follow-up (95% CI 0.46 to 5.64; p = 0.020). However, there was no difference in infection rates, dislocation rates, overall complication rates, and survival rates at short-term follow-up. Conclusion. The learning curve of rTHA was between 12 and 35 cases, which was dependent on the assessment goal, such as operating time, accuracy, and team working. Robotic arm-assisted total hip arthroplasty was associated with improved accuracy of component positioning and functional outcome, however no difference in complication rates or survival were observed at short- to mid-term follow-up. Overall, there remains an absence of high-quality level I evidence and cost analysis comparing rTHA and mTHA. Cite this article: Bone Joint J 2021;103-B(6):1009–1020


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 239 - 246
1 Mar 2023
Arshad Z Aslam A Al Shdefat S Khan R Jamil O Bhatia M

Aims

This systematic review aimed to summarize the full range of complications reported following ankle arthroscopy and the frequency at which they occur.

Methods

A computer-based search was performed in PubMed, Embase, Emcare, and ISI Web of Science. Two-stage title/abstract and full-text screening was performed independently by two reviewers. English-language original research studies reporting perioperative complications in a cohort of at least ten patients undergoing ankle arthroscopy were included. Complications were pooled across included studies in order to derive an overall complication rate. Quality assessment was performed using the Oxford Centre for Evidence-Based Medicine levels of evidence classification.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 502 - 511
1 May 2019
Lidder S Epstein DJ Scott G

Aims

Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components.

Materials and Methods

A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1138 - 1145
1 Sep 2018
Soreide E Murad MH Denbeigh JM Lewallen EA Dudakovic A Nordsletten L van Wijnen AJ Kakar S

Aims

Dupuytren’s contracture is a benign, myoproliferative condition affecting the palmar fascia that results in progressive contractures of the fingers. Despite increased knowledge of the cellular and connective tissue changes involved, neither a cure nor an optimum form of treatment exists. The aim of this systematic review was to summarize the best available evidence on the management of this condition.

Materials and Methods

A comprehensive database search for randomized controlled trials (RCTs) was performed until August 2017. We studied RCTs comparing open fasciectomy with percutaneous needle aponeurotomy (PNA), collagenase clostridium histolyticum (CCH) with placebo, and CCH with PNA, in addition to adjuvant treatments aiming to improve the outcome of open fasciectomy. A total of 20 studies, involving 1584 patients, were included.