Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1253 - 1259
1 Sep 2018
Seewoonarain S Johnson AA Barrett M

Aims

Informed patient consent is a legal prerequisite endorsed by multiple regulatory institutions including the Royal College of Surgeons and the General Medical Council. It is also recommended that the provision of written information is available and may take the form of a Patient Information Leaflet (PIL) with multiple PILs available from leading orthopaedic institutions. PILs may empower the patient, improve compliance, and improve the patient experience. The national reading age in the United Kingdom is less than 12 years and therefore PILs should be written at a readability level not exceeding 12 years old. We aim to assess the readability of PILs currently provided by United Kingdom orthopaedic institutions.

Patients and Methods

The readability of PILs on 58 common conditions provided by seven leading orthopaedic associations in January 2017, including the British Orthopaedic Association, British Hip Society, and the British Association of Spinal Surgeons, was assessed. All text in each PIL was analyzed using readability scores including the Flesch–Kincaid Grade Level (FKGL) and the Simple Measure of Gobbledygook (SMOG) test.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 292 - 299
1 Mar 2015
Karthik K Colegate-Stone T Dasgupta P Tavakkolizadeh A Sinha J

The use of robots in orthopaedic surgery is an emerging field that is gaining momentum. It has the potential for significant improvements in surgical planning, accuracy of component implantation and patient safety. Advocates of robot-assisted systems describe better patient outcomes through improved pre-operative planning and enhanced execution of surgery. However, costs, limited availability, a lack of evidence regarding the efficiency and safety of such systems and an absence of long-term high-impact studies have restricted the widespread implementation of these systems. We have reviewed the literature on the efficacy, safety and current understanding of the use of robotics in orthopaedics.

Cite this article: Bone Joint J 2015; 97-B:292–9.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 19 - 23
1 Jan 2014
Sabharwal S Gauher S Kyriacou S Patel V Holloway I Athanasiou T

We evaluated the quality of guidelines on thromboprophylaxis in orthopaedic surgery by examining how they adhere to validated methodological standards in their development. A structured review was performed for guidelines that were published between January 2005 and April 2013 in medical journals or on the Internet. A pre-defined computerised search was used in MEDLINE, Scopus and Google to identify the guidelines. The AGREE II assessment tool was used to evaluate the quality of the guidelines in the study.

Seven international and national guidelines were identified. The overall methodological quality of the individual guidelines was good. ‘Scope and Purpose’ (median score 98% interquartile range (IQR)) 86% to 98%) and ‘Clarity of Presentation’ (median score 90%, IQR 90% to 95%) were the two domains that received the highest scores. ‘Applicability’ (median score 68%, IQR 45% to 75%) and ‘Editorial Independence’ (median score 71%, IQR 68% to 75%) had the lowest scores.

These findings reveal that although the overall methodological quality of guidelines on thromboprophylaxis in orthopaedic surgery is good, domains within their development, such as ‘Applicability’ and ‘Editorial Independence’, need to be improved. Application of the AGREE II instrument by the authors of guidelines may improve the quality of future guidelines and provide increased focus on aspects of methodology used in their development that are not robust.

Cite this article: Bone Joint J 2014;96-B:19–23.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 729 - 734
1 Jun 2012
Kakkos SK Warwick D Nicolaides AN Stansby GP Tsolakis IA

We performed a systematic review and meta-analysis to compare the efficacy of intermittent mechanical compression combined with pharmacological thromboprophylaxis, against either mechanical compression or pharmacological prophylaxis in preventing deep-vein thrombosis (DVT) and pulmonary embolism in patients undergoing hip or knee replacement. A total of six randomised controlled trials, evaluating a total of 1399 patients, were identified. In knee arthroplasty, the rate of DVT was reduced from 18.7% with anticoagulation alone to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03; number needed to treat: seven). There was moderate, albeit non-significant, heterogeneity (I2 = 42%). In hip replacement, there was a non-significant reduction in DVT from 8.7% with mechanical compression alone to 7.2% with additional pharmacological prophylaxis (RR 0.84) and a significant reduction in DVT from 9.7% with anticoagulation alone to 0.9% with additional mechanical compression (RR 0.17, p < 0.001; number needed to treat: 12), with no heterogeneity (I2 = 0%). The included studies had insufficient power to demonstrate an effect on pulmonary embolism.

We conclude that the addition of intermittent mechanical leg compression augments the efficacy of anticoagulation in preventing DVT in patients undergoing both knee and hip replacement. Further research on the role of combined modalities in thromboprophylaxis in joint replacement and in other high-risk situations, such as fracture of the hip, is warranted.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 955 - 961
1 Jul 2009
Simpson AHWR Shalaby H Keenan G

Femoral lengthening using the Intramedullary Skeletal Kinetic Distractor is a new technique. However, with intramedullary distraction the surgeon has less control over the lengthening process. Therefore, 33 femora lengthened with this device were assessed to evaluate the effect of operative variables under the surgeon’s control on the course of lengthening. The desired lengthening was achieved in 32 of 33 limbs. Problems encountered included difficulty in achieving length in eight femora (24%) and uncontrolled lengthening in seven (21%). Uncontrolled lengthening was more likely if the osteotomy was placed with less than 80 mm of the thick portion of the nail in the distal fragment (p = 0.052), and a failure to lengthen was more likely if there was over 125 mm in the distal fragment (p = 0.008). The latter problem was reduced with over-reaming by 2.5 mm to 3 mm. Previous intramedullary nailing also predisposed to uncontrolled lengthening (p = 0.042), and these patients required less reaming.

Using the Intramedullary Skeletal Kinetic Distractor, good outcomes were obtained; problems were minimised by optimising the position of the osteotomy and the amount of over-reaming performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 382 - 385
1 Mar 2006
Schindler OS Spencer RF Smith MD

The aim of this study was to re-assess whether the use of a ‘one-knife technique’ can be considered as safe as the alternative practice of using separate skin and inside knives for elective orthopaedic surgery. A total of 609 knife blades from 203 elective orthopaedic operations, with equal numbers of skin, inside and control blades, were cultured using direct and enrichment media. We found 31 skin blades (15.3%), 22 inside blades (10.8%), and 13 control blades (6.4%) gave bacterial growth.

Of the 31 contaminated skin blades only three (9.7%) had growth of the same organism as found on the corresponding inside blade. It is not known whether contamination of deeper layers in the remaining 90% was prevented by changing the knife after the skin incision. The organisms cultured were predominantly coagulase-negative staphylococci and proprionibacterium species; both are known to be the major culprits in peri-prosthetic infection. Our study suggests that the use of separate skin and inside knives should be maintained as good medical practice, since the cost of a single deep infection in human and financial terms can be considerable.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 249 - 256
1 Feb 2005
Trebse R Pisot V Trampuz A

We have prospectively studied the outcome of infections associated with implants which were retained and treated using a standardised antimicrobial protocol. Over a period of four years, we studied 24 consecutive patients who had symptoms of infection for less than one year, a stable implant, no sinus tract and a known pathogen which was susceptible to recommended antimicrobial agents. The infections involved hip prostheses (14), knee prostheses (5), an internal fixation device (4), and an ankle prosthesis (1).

Twenty patients had a successful outcome at a median follow-up of 3.7 years (1.8 to 4.7); four had failure of the implant after a median follow-up of 1.2 years (0.3 to 2.5). The probability of survival without failure of treatment was 96% at one year (95% confidence interval (CI) 88 to 100), 92% at two years (95% CI 80 to 100) and 86% at three years (95% CI 72 to 100).

Patients with a short-term infection but with a stable implant, no sinus tract and a known pathogen may be successfully treated by retention of the implant and the use of a standardised regimen of antimicrobial treatment.