Advertisement for orthosearch.org.uk
Results 1 - 20 of 2519
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 876 - 883
1 Jul 2014
Grammatopoulos G Pandit HG da Assunção R Taylor A McLardy-Smith P De Smet KA Murray DW Gill HS

The orientation of the acetabular component is influenced not only by the orientation at which the surgeon implants the component, but also the orientation of the pelvis at the time of implantation. Hence, the orientation of the pelvis at set-up and its movement during the operation, are important. During 67 hip replacements, using a validated photogrammetric technique, we measured how three surgeons orientated the patient’s pelvis, how much the pelvis moved during surgery, and what effect these had on the final orientation of the acetabular component. Pelvic orientation at set-up, varied widely (mean (± 2, standard deviation (. sd. ))): tilt 8° (2. sd . ±32), obliquity –4° (2. sd . ±12), rotation –8° (2. sd . ±14). Significant differences in pelvic positioning were detected between surgeons (p < 0.001). The mean angular movement of the pelvis between set-up and component implantation was 9° (. sd. 6). Factors influencing pelvic movement included surgeon, approach (posterior >  lateral), procedure (hip resurfacing > total hip replacement) and type of support (p < 0.001). Although, on average, surgeons achieved their desired acetabular component orientation, there was considerable variability (2. sd. ±16) in component orientation. We conclude that inconsistency in positioning the patient at set-up and movement of the pelvis during the operation account for much of the variation in acetabular component orientation. Improved methods of positioning and holding the pelvis are required. Cite this article: Bone Joint J 2014; 96-B:876–83


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 634 - 640
1 May 2016
Pedowitz DI Kane JM Smith GM Saffel HL Comer C Raikin SM

Aims. Few reports compare the contribution of the talonavicular articulation to overall range of movement in the sagittal plane after total ankle arthroplasty (TAA) and tibiotalar arthrodesis. The purpose of this study was to assess changes in ROM and functional outcomes following tibiotalar arthrodesis and TAA. Patients and Methods. Patients who underwent isolated tibiotalar arthrodesis or TAA with greater than two-year follow-up were enrolled in the study. Overall arc of movement and talonavicular movement in the sagittal plane were assessed with weight-bearing lateral maximum dorsiflexion and plantarflexion radiographs. All patients completed Short Form-12 version 2.0 questionnaires, visual analogue scale for pain (VAS) scores, and the Foot and Ankle Ability Measure (FAAM). Results. In all, 41 patients who underwent TAA and 27 patients who underwent tibiotalar arthrodesis were enrolled in the study. The mean total arc of movement was 34.2° (17.0° to 59.1°) with an average contribution from the talonavicular joint of 10.5° (1.2° to 28.8°) in the TAA cohort. The average total arc of movement was 24.3° (6.9° to 44.3°) with a mean contribution from the talonavicular joint of 22.8° (5.6° to 41.4°) in the arthrodesis cohort. A statistically significant difference was detected for both total sagittal plane movement (p = 0.00025), and for talonavicular motion (p < 0.0001). A statistically significant lower VAS score (p = 0.0096) and higher FAAM (p = 0.01, p = 0.019, respectively) was also detected in the TAA group. Conclusion. TAA preserves more anatomical movement, has better pain relief and better patient-perceived post-operative function compared with patients undergoing fusion. The relative increase of talonavicular movement in fusion patients may play a role in the outcomes compared with TAA and may predispose these patients to degenerative changes over time. Take home message: TAA preserves more anatomic sagittal plane motion and provides greater pain relief and better patient-perceived outcomes compared with ankle arthrodesis. Cite this article: Bone Joint J 2016;98-B:634–40


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 37 - 41
1 Jan 1999
Vedi V Spouse E Williams A Tennant SJ Hunt DM Gedroyc WMW

We present the first study in vivo of meniscal movement in normal knees under load. Using an open MR scanner, allowing imaging in physiological positions in near to real-time, 16 young footballers were scanned moving from full extension to 90° flexion in the sagittal and coronal planes. Excursion of the meniscal horns, radial displacement and meniscal height were measured. On weight-bearing, the anterior horn of the medial meniscus moves through a mean of 7.1 mm and the posterior horn through 3.9 mm, with 3.6 mm of mediolateral radial displacement. The height of the anterior horn increases by 2.6 mm and that of the posterior horn by 2.0 mm. The anterior horn of the lateral meniscus moves 9.5 mm and the posterior horn 5.6 mm, with 3.7 mm of radial displacement. The height of the anterior horn increases by 4.0 mm, and that of the posterior horn by 2.4 mm. In non-weight-bearing, the anterior horn of the medial meniscus moves 5.4 mm and the posterior horn 3.8 mm, with 3.3 mm of radial displacement. The anterior horn of the lateral meniscus moves 6.3 mm, and the posterior horn 4.0 mm, with 3.4 mm of radial displacement. The most significant differences between weight-bearing and non-weight-bearing were the movement and vertical height of the anterior horn of the lateral meniscus


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 838 - 839
1 Nov 1987
Hardy A

A method of assessing foot movement suitable for use in clinical practice is presented. The method assesses the component of movement in the horizontal plane which is produced by rotating the calcaneum about the axis of the subtalar joint


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 366 - 372
1 Feb 2021
Sun Z Li J Luo G Wang F Hu Y Fan C

Aims. This study aimed to determine the minimal detectable change (MDC), minimal clinically important difference (MCID), and substantial clinical benefit (SCB) under distribution- and anchor-based methods for the Mayo Elbow Performance Index (MEPI) and range of movement (ROM) after open elbow arthrolysis (OEA). We also assessed the proportion of patients who achieved MCID and SCB; and identified the factors associated with achieving MCID. Methods. A cohort of 265 patients treated by OEA were included. The MEPI and ROM were evaluated at baseline and at two-year follow-up. Distribution-based MDC was calculated with confidence intervals (CIs) reflecting 80% (MDC 80), 90% (MDC 90), and 95% (MDC 95) certainty, and MCID with changes from baseline to follow-up. Anchor-based MCID (anchored to somewhat satisfied) and SCB (very satisfied) were calculated using a five-level Likert satisfaction scale. Multivariate logistic regression of factors affecting MCID achievement was performed. Results. The MDC increased substantially based on selected CIs (MDC 80, MDC 90, and MDC 95), ranging from 5.0 to 7.6 points for the MEPI, and from 8.2° to 12.5° for ROM. The MCID of the MEPI were 8.3 points under distribution-based and 12.2 points under anchor-based methods; distribution- and anchor-based MCID of ROM were 14.1° and 25.0°. The SCB of the MEPI and ROM were 17.3 points and 43.4°, respectively. The proportion of the patients who attained anchor-based MCID for the MEPI and ROM were 74.0% and 94.7%, respectively; furthermore, 64.2% and 86.8% attained SCB. Non-dominant arm (p = 0.022), higher preoperative MEPI rating (p < 0.001), and postoperative visual analogue scale pain score (p < 0.001) were independent predictors of not achieving MCID for the MEPI, while atraumatic causes (p = 0.040) and higher preoperative ROM (p = 0.005) were independent risk factors for ROM. Conclusion. In patients undergoing OEA, the MCID for the increased MEPI is 12.2 points and 25° increased ROM. The SCB is 17.3 points and 43.3°, respectively. Future studies using the MEPI and ROM to assess OEA outcomes should report not only statistical significance but also clinical importance. Cite this article: Bone Joint J 2021;103-B(2):366–372


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 752 - 760
1 Jun 2007
Yamada Y Toritsuka Y Horibe S Sugamoto K Yoshikawa H Shino K

We used three-dimensional movement analysis by computer modelling of knee flexion from 0° to 50° in 14 knees in 12 patients with recurrent patellar dislocation and in 15 knees in ten normal control subjects to compare the in vivo three-dimensional movement of the patella. Flexion, tilt and spin of the patella were described in terms of rotation angles from 0°. The location of the patella and the tibial tubercle were evaluated using parameters expressed as percentage patellar shift and percentage tubercle shift. Patellar inclination to the femur was also measured and patellofemoral contact was qualitatively and quantitatively analysed. The patients had greater values of spin from 20° to 50°, while there were no statistically significant differences in flexion and tilt. The patients also had greater percentage patellar shift from 0° to 50°, percentage tubercle shift at 0° and 10° and patellar inclination from 0° to 50° with a smaller oval-shaped contact area from 20° to 50° moving downwards on the lateral facet. Patellar movement analysis using a three-dimensional computer model is useful to clearly demonstrate differences between patients with recurrent dislocation of the patella and normal control subjects


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 736 - 740
1 May 2005
Tochigi Y Rudert MJ Brown TD McIff TE Saltzman CL

When performing the Scandinavian Total Ankle Replacement (STAR), the positioning of the talar component and the selection of mobile-bearing thickness are critical. A biomechanical experiment was undertaken to establish the effects of these variables on the range of movement (ROM) of the ankle. Six cadaver ankles containing a specially-modified STAR prosthesis were subjected to ROM determination, under weight-bearing conditions, while monitoring the strain in the peri-ankle ligaments. Each specimen was tested with the talar component positions in neutral, as well as 3 and 6 mm of anterior and posterior displacement. The sequence was repeated with an anatomical bearing thickness, as well as at 2 mm reduced and increased thicknesses. The movement limits were defined as 10% strain in any ligament, bearing lift-off from the talar component or limitations of the hardware. Both anterior talar component displacement and bearing thickness reduction caused a decrease in plantar flexion, which was associated with bearing lift-off. With increased bearing thickness, posterior displacement of the talar component decreased plantar flexion, whereas anterior displacement decreased dorsiflexion


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 598 - 601
1 Aug 1987
Bradley J Goodfellow J O'Connor J

After a unicompartmental Oxford knee replacement, a clear lateral radiographic view of the components may be obtained without the shadow of prosthetic components in the other compartment. Radiographs of 20 knees were studied; with the patient supine and the muscles relaxed, views with the knee at full extension and 90 degrees of flexion were obtained and the movement of the meniscal bearings over this range of flexion was measured. The bearings were found to move backwards on the tibia through an average distance of 4.4 mm (range 0.0 to 13.5 mm) in the medial compartment and 6.0 mm (range 1.6 to 13.0 mm) in the lateral compartment. These movements were in the same direction as that observed in cadaver specimens but smaller in magnitude. At 90 degrees of flexion, radiographs were obtained with the tibia twisted manually to the limits of medial and lateral rotation. The average movement of the bearings between these extremes was found to be 6.6 mm in the medial compartment and 5.1 mm in the lateral; their movements on the tibia were in opposite directions in the two compartments. Bearing movement was still present in knees examined five years after operation


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 448 - 458
1 Apr 2001
Jones LC Frondoza C Hungerford DS

The pathogenesis of aseptic loosening of total joint prostheses is not clearly understood. Two features are associated with loosened prostheses, namely, particulate debris and movement of the implant. While numerous studies have evaluated the cellular response to particulate biomaterials, few have investigated the influence of movement of the implant on the biological response to particles. Our aim was therefore to test the hypothesis that excessive mechanical stimulation of the periprosthetic tissues induces an inflammatory response and that the addition of particulate biomaterials intensifies this. We allocated 66 adult Beagle dogs to four groups as follows: stable implants with (I) and without (II) particulate polymethylmethacrylate (PMMA) and moving implants with (III) and without (IV) particulate PMMA. They were then evaluated at 2, 4, 6, 12 and 24 weeks. The stable implants were well tolerated and a thin, fibrous membrane of connective tissue was observed. There was evidence of positive staining in some cells for interleukin-6 (IL-6). Addition of particulate PMMA around the stable implants resulted in an increase in the fibroblastic response and positive staining for IL-6 and tumour necrosis factor-alpha (TNF-α). By contrast, movement of the implant resulted in an immediate inflammatory response characterised by large numbers of histiocytes and cytokine staining for IL-1ß, TNF-α and IL-6. Introduction of particulate PMMA aggravated this response. Animals with particulate PMMA and movement of the implant have an intense inflammatory response associated with accelerated bone loss. Our results indicate that the initiation of the inflammatory response to biomaterial particles was much slower than that to gross mechanical instability. Furthermore, when there was both particulate debris and movement, there was an amplification of the adverse tissue response as evidenced by the presence of osteolysis and increases in the presence of inflammatory cells and their associated cytokines


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 4 | Pages 521 - 539
1 Nov 1953
Perkins G

I have tried to stimulate interest in movement as a method of treatment. It is too much to expect that I shall have won over to my way of thinking doctors who are addicts of rest. I shall be content if they will occasionally ask: "Is my splint really necessary?"


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 572 - 577
1 May 2003
Theologis TN Harrington ME Thompson N Benson MKD

The aim of this study was to define objectively gait function in children with treated congenital talipes equinovarus (CTEV) and a good clinical result. The study also attempted an analysis of movement within the foot during gait. We compared 20 children with treated CTEV with 15 control subjects. Clinical assessment demonstrated good results from treatment. Three-dimensional gait analysis provided kinematic and kinetic data describing movement and moments at the joints of the lower limb during gait. A new method was used to study movement within the foot during gait. The data on gait showed significantly increased internal rotation of the foot during walking which was partially compensated for by external rotation at the hip. A mild foot drop and reduced plantar flexor power were also observed. Dorsiflexion at the midfoot was significantly increased, which probably compensated for reduced mobility at the hindfoot. Patients treated for CTEV with a good clinical result should be expected to have nearly normal gait and dynamic foot movement, but there may be residual intoeing, mild foot drop, loss of plantar flexor power with compensatory increased midfoot dorsiflexion and external hip rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 3 | Pages 450 - 457
1 Aug 1954
Joseph J

1. The range of variation in the movements at the metatarso-phalangeal and interphalangeal joints of the big toe in fifty males has been investigated by means of lateral radiographs. 2. In the "neutral" position the proximal phalanx is dorsiflexed on the metatarsal and the distal phalanx dorsiflexed on the proximal. Sometimes the distal phalanx is plantar flexed on the proximal but this is not associated with any obvious abnormality of function. 3. There is a wide variation between individuals in the amount of movement found at these joints. 4. At the metatarso-phalangeal joint dorsiflexion is much more free than plantar flexion. The opposite is the case at the interphalangeal joint. 5. There is no significant difference between the right and left sides. Only in plantar flexion at both joints are there significant reductions in the range of movement in older age groups. These reductions are not functionally important. 6. There is an inverse relationship between active and passive dorsiflexion: the greater the range of active dorsiflexion, the less is the range of additional passive dorsiflexion. 7. In lateral radiographs the head of the metatarsal is always rounded


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 375 - 377
1 Mar 2007
Kasten P Geiger F Zeifang F Weiss S Thomsen M

Treatment by continuous passive movement at home is an alternative to immobilisation in a cast after surgery for club foot. Compliance with the recommended treatment, of at least four hours daily, is unknown. The duration of treatment was measured in 24 of 27 consecutive children with a mean age of 24 months (5 to 75) following posteromedial release for idiopathic club foot. Only 21% (5) of the children used the continuous passive movement machine as recommended. The mean duration of treatment at home each day was 126 minutes (11 to 496). The mean range of movement for plantar flexion improved from 15.2° (10.0° to 20.6°) to 18.7° (10.0° to 33.0°) and for dorsiflexion from 12.3° (7.4° to 19.4°) to 18.9° (10.0° to 24.1°) (both, p = 0.0001) when the first third of therapy was compared with the last third. A low level of patient compliance must be considered when the outcome after treatment at home is interpreted


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 626 - 629
1 Jul 1997
Lizaur A Marco L Cebrian R

We report a prospective study, using multivariate analysis, of the factors which influence the range of movement after total knee arthroplasty in 74 patients with 83 arthroplasties at a mean follow-up of 23.6 months (12 to 41). All the patients had a diagnosis of osteoarthritis, a severely disabled knee with a Knee Society system score of less than 60, varus deformity, no previous surgery to the knee, identical prostheses implanted with a similar surgical technique, and no postoperative complications which may have affected the range of movement. The most important factors which influenced the range of movement after arthroplasty were the preoperative range of flexion and the body-weight of the patient. There was a significant improvement in flexion and reduction of flexion contracture at each successive review up to 12 months after operation. Patients with restricted movement before operation showed a satisfactory gain at final review


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 195 - 198
1 Mar 2001
Walker CRC Myles C Nutton R Rowe P

We used electrogoniometers to measure the range of movement (ROM) of the knee during various activities, comparing 50 patients with osteoarthritis of the knee (OA) with 20 healthy age- and sex-matched subjects. The minimum and maximum joint angles and the ranges of excursion of the patient and control groups were tested for significant differences, using an unrelated Student’s t-test with pooled variance. Knee flexion in patients with OA was significantly reduced during all activities (p < 0.05), but differences in knee extension were not significant except when patients negotiated stairs. We believe that this reduction in ROM is caused by inhibition due to pain when load-bearing. Static non-load-bearing measurements of the ROM poorly reflected the functional ROM, with a coefficient of determination (r. 2. ) of 0.59 in the patient group and 0.60 in the control group. Electrogoniometry of the ROM of the knee provides a reliable, accurate and objective measurement of knee function


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 804 - 808
1 Jun 2005
Matsuda Y Ishii Y Noguchi H Ishii R

We performed a randomised, prospective study of 80 mobile-bearing total knee arthroplasties (80 knees) in order to measure the effects of varus-valgus laxity and balance on the range of movement (ROM) one year after operation. Forty knees had a posterior-cruciate-ligament (PCL)-retaining prosthesis and the other 40 a PCL-sacrificing prosthesis. In the balanced group (69 knees) in which the difference between varus and valgus was less than 2°, the mean ROM improved significantly from 107.6° to 117.7° (p < 0.0001). By contrast, in the 11 knees which were unbalanced and in which the difference between varus and valgus laxity exceeded 2°, the ROM decreased from a mean of 121.0° to 112.7° (p = 0.0061). We conclude that coronal laxity, especially balanced laxity, is important for achieving an improved ROM in mobile-bearing total knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 761 - 764
1 Nov 1987
Phillips T

The purpose of this study was to establish if the Bateman prosthesis functions as a bipolar device moving primarily at the inner metal-on-polyethylene bearing as originally proposed, or as a unipolar hemiarthroplasty moving at the outer metal-on-cartilage surface as has recently been suggested. One hundred hips were examined at one year follow-up; 78 were examined again at two to four years. The replacement was performed for arthritis in 76 hips and for femoral neck fracture in 24. Movement was assessed both with and without weight-bearing. In 80% of the arthritis group the prosthesis functioned as a bipolar hip replacement with movement occurring primarily at the inner metal-on-polyethylene surface. By contrast, in 75% of the fracture group the prosthesis functioned largely as a unipolar device with movement occurring primarily at the outer metal-on-cartilage surface. In all cases examined serially the movement pattern was the same at two to four years as it has been at one year. Clearly, the action of the prosthesis depends on the condition of the acetabular cartilage


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1090 - 1095
1 Aug 2010
Seon JK Park SJ Yoon TR Lee KB Moon ES Song EK

The amount of anteroposterior laxity required for a good range of movement and knee function in a cruciate-retaining total knee replacement (TKR) continues to be debated. We undertook a retrospective study to evaluate the effects of anteroposterior laxity on the range of movement and knee function in 55 patients following the e-motion cruciate-retaining TKR with a minimum follow-up of two years. The knees were divided into stable (anteroposterior translation, ≤ 10 mm, 38 patients) and unstable (anteroposterior translation, > 10 mm, 17) groups based on the anteroposterior laxity, measured using stress radiographs. We compared the Hospital for Special Surgery (HSS) scores, the Western Ontario MacMasters University Osteoarthritis (WOMAC) index, weight-bearing flexion, non-weight-bearing flexion and the reduction of flexion under weight-bearing versus non-weight-bearing conditions, which we referred to as delta flexion, between the two groups at the final follow-up. There were no differences between the stable and unstable groups with regard to the mean HHS and WOMAC total scores, as well as weight-bearing and non-weight-bearing flexion (p = 0.277, p = 0.082, p = 0.095 and p = 0.646, respectively). However, the stable group had a better WOMAC function score and less delta flexion than the unstable group (p = 0.011 and p = 0.005, respectively). Our results suggest that stable knees with laxity ≤ 10 mm have a good functional outcome and less reduction of flexion under weight-bearing conditions than unstable knees with laxity > 10 mm following an e-motion cruciate-retaining TKR


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 580 - 589
1 May 2014
Nakahara I Takao M Sakai T Miki H Nishii T Sugano N

To confirm whether developmental dysplasia of the hip has a risk of hip impingement, we analysed maximum ranges of movement to the point of bony impingement, and impingement location using three-dimensional (3D) surface models of the pelvis and femur in combination with 3D morphology of the hip joint using computer-assisted methods. Results of computed tomography were examined for 52 hip joints with DDH and 73 normal healthy hip joints. DDH shows larger maximum extension (p = 0.001) and internal rotation at 90° flexion (p < 0.001). Similar maximum flexion (p = 0.835) and external rotation (p = 0.713) were observed between groups, while high rates of extra-articular impingement were noticed in these directions in DDH (p < 0.001). Smaller cranial acetabular anteversion (p = 0.048), centre-edge angles (p < 0.001), a circumferentially shallower acetabulum, larger femoral neck anteversion (p < 0.001), and larger alpha angle were identified in DDH. Risk of anterior impingement in retroverted DDH hips is similar to that in retroverted normal hips in excessive adduction but minimal in less adduction. These findings might be borne in mind when considering the possibility of extra-articular posterior impingement in DDH being a source of pain, particularly for patients with a highly anteverted femoral neck. Cite this article: Bone Joint J 2014;96-B:580–9


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 1033 - 1040
1 Jul 2010
Nishino T Chang F Ishii T Yanai T Mishima H Ochiai N

We have previously shown that joint distraction and movement with a hinged external fixation device for 12 weeks was useful for repairing a large articular cartilage defect in a rabbit model. We have now investigated the results after six months and one year. The device was applied to 16 rabbits who underwent resection of the articular cartilage and subchondral bone from the entire tibial plateau. In group A (nine rabbits) the device was applied for six months. In group B (seven rabbits) it was in place for six months, after which it was removed and the animals were allowed to move freely for an additional six months. The cartilage remained sound in all rabbits. The areas of type II collagen-positive staining and repaired soft tissue were larger in group B than in group A. These findings provide evidence of long-term persistence of repaired cartilage with this technique and that weight-bearing has a positive effect on the quality of the cartilage