Advertisement for orthosearch.org.uk
Results 1 - 14 of 14
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 953 - 960
1 Sep 2023
Cance N Erard J Shatrov J Fournier G Gunst S Martin GL Lustig S Servien E

Aims

The aim of this study was to evaluate the association between chondral injury and interval from anterior cruciate ligament (ACL) tear to surgical reconstruction (ACLr).

Methods

Between January 2012 and January 2022, 1,840 consecutive ACLrs were performed and included in a single-centre retrospective cohort. Exclusion criteria were partial tears, multiligament knee injuries, prior ipsilateral knee surgery, concomitant unicompartmental knee arthroplasty or high tibial osteotomy, ACL agenesis, and unknown date of tear. A total of 1,317 patients were included in the final analysis, with a median age of 29 years (interquartile range (IQR) 23 to 38). The median preoperative Tegner Activity Score (TAS) was 6 (IQR 6 to 7). Patients were categorized into four groups according to the delay to ACLr: < three months (427; 32%), three to six months (388; 29%), > six to 12 months (248; 19%), and > 12 months (254; 19%). Chondral injury was assessed during arthroscopy using the International Cartilage Regeneration and Joint Preservation Society classification, and its association with delay to ACLr was analyzed using multivariable analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 907 - 915
1 Sep 2024
Ross M Zhou Y English M Sharplin P Hirner M

Aims

Knee osteoarthritis (OA) is characterized by a chronic inflammatory process involving multiple cytokine pathways, leading to articular cartilage degeneration. Intra-articular therapies using pharmaceutical or autologous anti-inflammatory factors offer potential non-surgical treatment options. Autologous protein solution (APS) is one such product that uses the patient’s blood to produce a concentrate of cells and anti-inflammatory cytokines. This study evaluated the effect of a specific APS intra-articular injection (nSTRIDE) on patient-reported outcome measures compared to saline in moderate knee OA.

Methods

A parallel, double-blinded, placebo-controlled randomized controlled trial was conducted, where patients with unilateral moderate knee OA (Kellgren-Lawrence grade 2 or 3) received either nSTRIDE or saline (placebo) injection to their symptomatic knee. The primary outcome was the difference in Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) total score at 12 months post-intervention. Secondary outcomes included WOMAC component scores, Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (VAS) scores at all follow-up timepoints (three, six, and 12 months).


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims

This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant.

Methods

A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1595 - 1603
1 Oct 2021
Magill P Hill JC Bryce L Martin U Dorman A Hogg R Campbell C Gardner E McFarland M Bell J Benson G Beverland D

Aims

In total knee arthroplasty (TKA), blood loss continues internally after surgery is complete. Typically, the total loss over 48 postoperative hours can be around 1,300 ml, with most occurring within the first 24 hours. We hypothesize that the full potential of tranexamic acid (TXA) to decrease TKA blood loss has not yet been harnessed because it is rarely used beyond the intraoperative period, and is usually withheld from ‘high-risk’ patients with a history of thromboembolic, cardiovascular, or cerebrovascular disease, a patient group who would benefit greatly from a reduced blood loss.

Methods

TRAC-24 was a prospective, phase IV, single-centre, open label, parallel group, randomized controlled trial on patients undergoing TKA, including those labelled as high-risk. The primary outcome was indirect calculated blood loss (IBL) at 48 hours. Group 1 received 1 g intravenous (IV) TXA at the time of surgery and an additional 24-hour postoperative oral regime of four 1 g doses, while Group 2 only received the intraoperative dose and Group 3 did not receive any TXA.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 18 - 22
1 Jun 2021
Omari AM Parcells BW Levine HB Seidenstein A Parvizi J Klein GR

Aims

The optimal management of an infrapopliteal deep venous thrombosis (IDVT) following total knee arthroplasty (TKA) remains unknown. The risk of DVT propagation and symptom progression must be balanced against potential haemorrhagic complications associated with administration of anticoagulation therapy. The current study reports on a cohort of patients diagnosed with IDVT following TKA who were treated with aspirin, followed closely for development of symptoms, and scanned with ultrasound to determine resolution of IDVT.

Methods

Among a cohort of 5,078 patients undergoing TKA, 532 patients (695 TKAs, 12.6%) developed an IDVT between 1 January 2014 to 31 December 2019 at a single institution, as diagnosed using Doppler ultrasound at the first postoperative visit. Of the entire cohort of 532 patients with IDVT, 91.4% (486/532) were treated with aspirin (325 mg twice daily) and followed closely. Repeat lower limb ultrasound was performed four weeks later to evaluate the status of IDVT.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 22 - 27
1 Jul 2019
Kalbian IL Tan TL Rondon AJ Bonaddio VA Klement MR Foltz C Lonner JH

Aims

Unicompartmental knee arthroplasty (UKA) provides improved early functional outcomes and less postoperative morbidity and pain compared with total knee arthroplasty (TKA). Opioid prescribing has increased in the last two decades, and recently states in the USA have developed online Prescription Drug Monitoring Programs to prevent overprescribing of controlled substances. This study evaluates differences in opioid requirements between patients undergoing TKA and UKA.

Patients and Methods

We retrospectively reviewed 676 consecutive TKAs and 241 UKAs. Opioid prescriptions in morphine milligram equivalents (MMEs), sedatives, benzodiazepines, and stimulants were collected from State Controlled Substance Monitoring websites six months before and nine months after the initial procedures. Bivariate and multivariate analysis were performed for patients who had a second prescription and continued use.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 10 - 16
1 Jul 2019
Fillingham YA Darrith B Calkins TE Abdel MP Malkani AL Schwarzkopf R Padgett DE Culvern C Sershon RA Bini S Della Valle CJ

Aims

Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA. The purpose of this multicentre randomized clinical trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA.

Patients and Methods

From six-centres, 233 revision TKAs were randomized to one of four regimens: 1 g of intravenous (IV) TXA given prior to the skin incision, a double-dose regimen of 1 g IV TXA given both prior to skin incision and at time of wound closure, a combination of 1 g IV TXA given prior to skin incision and 1 g of intraoperative topical TXA, or three doses of 1950 mg oral TXA given two hours preoperatively, six hours postoperatively, and on the morning of postoperative day one. Randomization was performed based on the type of revision procedure to ensure equivalent distribution among groups. Power analysis determined that 40 patients per group were necessary to identify a 1 g/dl difference in the reduction of haemoglobin postoperatively between groups with an alpha of 0.05 and power of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence.


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 62 - 67
1 Jan 2018
Bedard NA DeMik DE Dowdle SB Callaghan JJ

Aims

The purpose of this study was to evaluate trends in opioid use after unicompartmental knee arthroplasty (UKA), to identify predictors of prolonged use and to compare the rates of opioid use after UKA, total knee arthroplasty (TKA) and total hip arthroplasty (THA).

Materials and Methods

We identified 4205 patients who had undergone UKA between 2007 and 2015 from the Humana Inc. administrative claims database. Post-operative opioid use for one year post-operatively was assessed using the rates of monthly repeat prescription. These were then compared between patients with and without a specific variable of interest and with those of patients who had undergone TKA and THA.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 101 - 104
1 Nov 2014
Lombardi Jr AV Berend KR Adams JB

Previous studies of failure mechanisms leading to revision total knee replacement (TKR) performed between 1986 and 2000 determined that many failed early, with a disproportionate amount accounted for by infection and implant-associated factors including wear, loosening and instability. Since then, efforts have been made to improve implant performance and instruct surgeons in best practice. Recently our centre participated in a multi-centre evaluation of 844 revision TKRs from 2010 to 2011. The purpose was to report a detailed analysis of failure mechanisms over time and to see if failure modes have changed over the past 10 to 15 years. Aseptic loosening was the predominant mechanism of failure (31.2%), followed by instability (18.7%), infection (16.2%), polyethylene wear (10.0%), arthrofibrosis (6.9%) and malalignment (6.6%). The mean time to failure was 5.9 years (ten days to 31 years), 35.3% of all revisions occurred at less than two years, and 60.2% in the first five years. With improvements in implant and polyethylene manufacture, polyethylene wear is no longer a leading cause of failure. Early mechanisms of failure are primarily technical errors. In addition to improving implant longevity, industry and surgeons must work together to decrease these technical errors. All reports on failure of TKR contain patients with unexplained pain who not infrequently have unmet expectations. Surgeons must work to achieve realistic patient expectations pre-operatively, and therefore, improve patient satisfaction post-operatively.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):101–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 126 - 133
1 Nov 2012
Vince KG

In this paper, we consider wound healing after total knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 914 - 918
1 Jul 2012
Jameson SS Baker PN Charman SC Deehan DJ Reed MR Gregg PJ Van der Meulen JH

We compared thromboembolic events, major haemorrhage and death after knee replacement in patients receiving either aspirin or low-molecular-weight heparin (LMWH). Data from the National Joint Registry for England and Wales were linked to an administrative database of hospital admissions in the English National Health Service. A total of 156 798 patients between April 2003 and September 2008 were included and followed for 90 days. Multivariable risk modelling was used to estimate odds ratios adjusted for baseline risk factors (AOR). An AOR < 1 indicates that risk rates are lower with LMWH than with aspirin. In all, 36 159 patients (23.1%) were prescribed aspirin and 120 639 patients (76.9%) were prescribed LMWH. We found no statistically significant differences between the aspirin and LMWH groups in the rate of pulmonary embolism (0.49% vs 0.45%, AOR 0.88 (95% confidence interval (CI) 0.74 to 1.05); p = 0.16), 90-day mortality (0.39% vs 0.45%, AOR 1.13 (95% CI 0.94 to 1.37); p = 0.19) or major haemorrhage (0.37% vs 0.39%, AOR 1.01 (95% CI 0.83 to 1.22); p = 0.94). There was a significantly greater likelihood of needing to return to theatre in the aspirin group (0.26% vs 0.19%, AOR 0.73 (95% CI 0.58 to 0.94); p = 0.01). Between patients receiving LMWH or aspirin there was only a small difference in the risk of pulmonary embolism, 90-day mortality and major haemorrhage.

These results should be considered when the existing guidelines for thromboprophylaxis after knee replacement are reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 639 - 645
1 May 2010
Kim Y Choi Y Kim J

We undertook a study in which 138 female patients with a mean age of 71.2 years (51 to 82) received a standard NexGen CR-flex prosthesis in one knee and a gender-specific NexGen CR-flex prosthesis in the other. The mean follow-up period was 3.25 years (3.1 to 3.5). The aspect ratios of the standard and gender-specific prostheses were compared with that of the distal femur.

The mean post-operative Knee Society knee scores were 94 (70 to 100) and 93 (70 to 100) points and the function scores were 83 (60 to 100) and 84 (60 to 100) points for the standard implants and the gender-specific designs, respectively. The mean post-operative Western Ontario and McMaster Universities score was 26.4 points (0 to 76). Patient satisfaction, the radiological results and the complication rates were similar in the two groups. In those with a standard prosthesis, the femoral component was closely matched in 80 knees (58.0%), overhung in 14 (10.1%) and undercovered the bone in 44 (31.9%). In those with a gender-specific prosthesis, it was closely matched in 15 knees (10.9%) and undercovered the bone in 123 (89.1%).

Since we found no significant differences between the two groups with regard to the clinical and radiological results, patient satisfaction or complication rate, the goal of the design of the gender-specific CR-flex prosthesis to improve the outcome was not achieved in our patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 889 - 895
1 Jul 2009
Gandhi R Tsvetkov D Davey JR Mahomed NN

Using meta-analysis we compared the survival and clinical outcomes of cemented and uncemented techniques in primary total knee replacement. We reviewed randomised controlled trials and observational studies comparing cemented and uncemented fixation. Our primary outcome was survival of the implant free of aseptic loosening. Our secondary outcome was joint function as measured by the Knee Society score. We identified 15 studies that met our final eligibility criteria. The combined odds ratio for failure of the implant due to aseptic loosening for the uncemented group was 4.2 (95% confidence interval (CI) 2.7 to 6.5) (p < 0.0001). Subgroup analysis of data only from randomised controlled trials showed no differences between the groups for odds of aseptic loosening (odds ratio 1.9, 95% CI 0.55 to 6.40, p = 0.314). The weighted mean difference for the Knee Society score was 0.005 (95% CI −0.26 to 0.26) (p = 0.972).

There was improved survival of the cemented compared to uncemented implants, with no statistically significant difference in the mean Knee Society score between groups for all pooled data.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1585 - 1593
1 Dec 2008
Henricson A Linder L Nilsson KG

We compared the performance of uncemented trabecular metal tibial components in total knee replacement with that of cemented tibial components in patients younger than 60 years over two years using radiostereophotogrammetric analysis (RSA). A total of 22 consecutive patients (mean age 53 years, 33 to 59, 26 knees) received an uncemented NexGen trabecular metal cruciate-retaining monobloc tibial component and 19 (mean 53 years, 44 to 59, 21 knees) a cemented NexGen Option cruciate-retaining modular tibial component.

All the trabecular metal components migrated during the initial three months and then stabilised. The exception was external rotation, which did not stabilise until 12 months. Unlike conventional metal-backed implants which displayed a tilting migration comprising subsidence and lift-off from the tibial tray, most of the trabecular metal components showed subsidence only, probably due to the elasticity of the implant.

This pattern of subsidence is regarded as being beneficial for uncemented fixation.