Advertisement for orthosearch.org.uk
Results 1 - 20 of 36
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 470 - 477
1 Apr 2020
Alammar Y Sudnitsyn A Neretin A Leonchuk S Kliushin NM

Aims. Infected and deformed neuropathic feet and ankles are serious challenges for surgical management. In this study we present our experience in performing ankle arthrodesis in a closed manner, without surgical preparation of the joint surfaces by cartilaginous debridement, but instead using an Ilizarov ring fixator (IRF) for deformity correction and facilitating fusion, in arthritic neuropathic ankles with associated osteomyelitis. Methods. We retrospectively reviewed all the patients who underwent closed ankle arthrodesis (CAA) in Ilizarov Scientific Centre from 2013 to 2018 (Group A) and compared them with a similar group of patients (Group B) who underwent open ankle arthrodesis (OAA). We then divided the neuropathic patients into three arthritic subgroups: Charcot joint, Charcot-Maire-Tooth disease, and post-traumatic arthritis. All arthrodeses were performed by using an Ilizarov ring fixator. All patients were followed up clinically and radiologically for a minimum of 12 months to assess union and function. Results. The union rate for Group A was 81% (17/21) while it was 84.6% (33/39) for Group B. All the nonunions in Group A underwent revision with an open technique and achieved 100% union. Mean duration of IRF was 71.5 days (59 to 82) in Group A and 69 days (64.8 to 77.7) in Group B. The American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score was similar in both groups. The postoperative hospital stay was shorter in Group A (21 days (SD 8)) than Group B (28 days (SD 9)). In the latter Group there were more problems with wound healing and greater requirement for antibiotic treatment. The mean operating time was 40 minutes (SD 9) in Group A compared to 80 minutes (SD 13) in Group B. Recurrence of infection occurred in 19% (4/21) and 15.5% (6/39) for Group A and Group B respectively. Conclusion. We found CAA using an IRF to be an effective method for ankle arthrodesis in infected neuropathic foot and ankle cases and afforded comparable results to open methods. Due to its great advantages, Ilizarov method of CAA should always be considered for neuropathic ankles in suitable patients. Cite this article: Bone Joint J 2020;102-B(4):470–477


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1399 - 1405
1 Oct 2016
Rohilla R Wadhwani J Devgan A Singh R Khanna M

Aims. This is a prospective randomised study which compares the radiological and functional outcomes of ring and rail fixators in patients with an infected gap (> 3 cm) nonunion of the tibia. Patients and Methods. Between May 2008 and February 2013, 70 patients were treated at our Institute for a posttraumatic osseocutaneous defect of the tibia measuring at least 3 cm. These were randomised into two groups of 35 patients using the lottery method. Group I patients were treated with a ring fixator and group II patients with a rail fixator. The mean age was 33.2 years (18 to 64) in group I and 29.3 years (18 to 65) in group II. The mean bone gap was 5.84 cm in group I and 5.78 cm in group II. The mean followup was 33.8 months in group I and 32.6 months in group II. Bone and functional results were assessed using the classification of the Association for the Study and Application of the Method of Ilizarov (ASAMI). Functional results were also assessed at six months using the short musculoskeletal functional assessment (SMFA) score. Results. The bone result was excellent, good, fair and poor in 21, 12, 0 and 2 in group I; and 14, 15, 3, and 3 in group II, respectively. The functional results were excellent, good, fair, poor and failure in 16, 17, 1, 0 and 1 in group I; and 22, 10, 0, 3 and 0 in group II, respectively. Both fixator systems achieved comparable rates of union and functional outcomes. The rate of deep pintract infection was significantly higher in the rail fixator group but patients found it more comfortable. Conclusion. We recommend the use of a ring fixator in patients with a bone gap of more than 6 cm. Patients with a bone gap up to 6 cm can be managed with either a ring or rail fixator. Cite this article: Bone Joint J 2016;98B:1399–1405


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1416 - 1422
1 Nov 2019
Rohilla R Sharma PK Wadhwani J Rohilla S Beniwal R Singh R Devgan A

Aims

In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia.

Patients and Methods

Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 868 - 875
1 Aug 2004
Okcu G Aktuglu K

We retrospectively reviewed 60 fractures of the tibial plafond treated by either an ankle-sparing diaphyseal-epiphyseal technique using the Ilizarov ring fixator or by an ankle-spanning technique using a monolateral articulated external fixator. The Ilizarov ring fixator was applied in 24 fractures and the monolateral articulated transarticular external fixator in 20. Both techniques were combined with limited open reduction and internal fixation of the articular surface if necessary. Between three and nine years after the injury, all patients returned for clinical and radiological assessment and evaluation of ankle function using the modified Mazur score. There were no significant differences between the two groups in terms of age, gender, mechanism of injury, type of fracture or length of follow-up. The mean functional ankle score was 86 points for the Ilizarov group and 82 points for the articulated fixator group. The difference was not significant (p = 0.07). There were no significant differences between the groups with regard to the radiographic score and late complications. Patients treated with the Ilizarov ring fixator had significantly better ankle and subtalar movement. We conclude that both techniques of external fixation are satisfactory methods of treatment for fractures of the tibial plafond, but that the total arc of movement of the joint is preserved better without bridging the ankle


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1100 - 1106
1 Aug 2010
Kapoor SK Kataria H Patra SR Boruah T

Open reduction and internal fixation of high-energy pilon fractures are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. A total of 17 consecutive patients with pilon fractures of AO/OTA type 43-B3 (n = 1), type C2 (n = 12) and type C3 (n = 4) were treated by indirect reduction by capsuloligamentotaxis and stabilisation using an ankle-spanning Ilizarov fixator. The calcaneal ring was removed at a mean of 3.7 weeks (3 to 6). A total of 16 patients were available for follow-up at a mean of 29 months (23 to 43). The mean time to healing was 15.8 weeks (13 to 23). Nine patients had pin-track infections but none had deep infection or osteomyelitis. Four patients (25%) had malunion. Fair, good or excellent ankle scores were found in 14 patients. External fixation with a ring fixator achieves stable reduction of the fractured fragments without additional trauma to soft tissues. With minimum complications and good healing results, the Ilizarov apparatus is particularly useful for high-energy pilon fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 868 - 872
1 Jun 2005
Metcalfe AJ Saleh M Yang L

Biomechanical studies involving all-wire and hybrid types of circular frame have shown that oblique tibial fractures remain unstable when they are loaded. We have assessed a range of techniques for enhancing the fixation of these fractures. Eight models were constructed using Sawbones tibiae and standard Sheffield ring fixators, to which six additional fixation techniques were applied sequentially. The major component of displacement was shear along the obliquity of the fracture. This was the most sensitive to any change in the method of fixation. All additional fixation systems were found to reduce shear movement significantly, the most effective being push-pull wires and arched wires with a three-hole bend. Less effective systems included an additional half pin and arched wires with a shallower arc. Angled pins were more effective at reducing shear than transverse pins. The choice of additional fixation should be made after consideration of both the amount of stability required and the practicalities of applying the method to a particular fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 267 - 272
1 Feb 2010
Abdel-Ghani H Ebeid W El-Barbary H

We describe the management of nonunion combined with limb-length discrepancy following vascularised fibular grafting for the reconstruction of long-bone defects in the lower limb after resection of a tumour in skeletally immature patients. We operated on nine patients with a mean age of 13.1 years (10.5 to 14.5) who presented with a mean limb-length discrepancy of 7 cm (4 to 9) and nonunion at one end of a vascularised fibular graft, which had been performed previously, to reconstruct a bone defect after resection of an osteosarcoma. Reconstruction was carried out using a ring fixator secured with correction by half pins of any malalignment, compression of the site of nonunion and lengthening through a metaphyseal parafocal osteotomy without bone grafting. The expected limb-length discrepancy at maturity was calculated using the arithmetic method. Solid union and the intended leg length were achieved in all the patients. Excessive scarring and the distorted anatomy from previous surgery in these patients required other procedures to be performed with minimal exposures and dissection in order to avoid further compromise to the vascularity of the graft or damage to neurovascular structures. The methods which we chose were simple and effective in addressing these complex problems


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 50 - 54
1 Jan 2001
Oostenbroek HJ van Roermund PM

We treated 15 patients by arthrodesis of the knee after removal of an infected total knee arthroplasty, using an Ilizarov ring fixator. Eight had a failed arthrodesis by another technique. The mean age of the patients was 75 years, the mean duration of retention of the frame was 28 weeks, the mean treatment time 51 weeks, and the mean follow-up 52 months. All but one knee fused at the first attempt, a rate of union of 93%. The incidence of complications related to treatment was 80%. The length of treatment and rates of complication were attributed to advanced age and the adverse local clinical factors in these patients. The Ilizarov method is a promising technique for achieving arthrodesis under these circumstances


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 142 - 148
1 Jan 2000
Claes L Laule J Wenger K Suger G Liener U Kinzl L

The treatment of large bony defects by callus distraction is well accepted, but the duration of treatment is long and the rate of complications increases accordingly. We have examined the effect of the stiffness of the axial fixator on reducing the time for maturation of callus. We created a mid-diaphyseal defect of 15 mm in the metatarsal bone in sheep and stabilised it with a ring fixator. After four days a bony segment was transported for 16 days at 1 mm per day. After 64 days the animals were divided into four groups, three with axial interfragmentary movement (IFM) of 0.5, 1.2 and 3.0 mm, respectively, and a control group. The 3.0 mm IFM group had the smallest bone density (p = 0.001) and area of callus and the largest IFM after 12 weeks; it also had typical clinical signs of hypertrophic nonunion. The most rapid stiffening of the callus was in the 0.5 mm group which had the smallest IFM (p = 0.04) after 12 weeks and radiological signs of bridging of the defect. These results indicate that suitable dynamic axial stimulation can enhance maturation of distraction callus when the initial amplitude is small, but that a large IFM can lead to delayed union


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 972 - 979
1 Aug 2022
Richardson C Bretherton CP Raza M Zargaran A Eardley WGP Trompeter AJ

Aims

The purpose of this study was to determine the weightbearing practice of operatively managed fragility fractures in the setting of publically funded health services in the UK and Ireland.

Methods

The Fragility Fracture Postoperative Mobilisation (FFPOM) multicentre audit included all patients aged 60 years and older undergoing surgery for a fragility fracture of the lower limb between 1 January 2019 and 30 June 2019, and 1 February 2021 and 14 March 2021. Fractures arising from high-energy transfer trauma, patients with multiple injuries, and those associated with metastatic deposits or infection were excluded. We analyzed this patient cohort to determine adherence to the British Orthopaedic Association Standard, “all surgery in the frail patient should be performed to allow full weight-bearing for activities required for daily living”.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1611 - 1618
1 Oct 2021
Kavarthapu V Budair B

Aims

In our unit, we adopt a two-stage surgical reconstruction approach using internal fixation for the management of infected Charcot foot deformity. We evaluate our experience with this functional limb salvage method.

Methods

We conducted a retrospective analysis of prospectively collected data of all patients with infected Charcot foot deformity who underwent two-stage reconstruction with internal fixation between July 2011 and November 2019, with a minimum of 12 months’ follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1168 - 1176
1 Sep 2019
Calder PR McKay JE Timms AJ Roskrow T Fugazzotto S Edel P Goodier WD

Aims

The Precice intramedullary limb-lengthening system has demonstrated significant benefits over external fixation lengthening methods, leading to a paradigm shift in limb lengthening. This study compares outcomes following antegrade and retrograde femoral lengthening in both adolescent and adult patients.

Patients and Methods

A retrospective review of prospectively collected data was undertaken of a consecutive series of 107 femoral lengthening operations in 92 patients. In total, 73 antegrade nails and 34 retrograde nails were inserted. Outcome was assessed by the regenerate healing index (HI), hip and knee range of movement (ROM), and the presence of any complications.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 283 - 288
1 Feb 2017
Hughes A Heidari N Mitchell S Livingstone J Jackson M Atkins R Monsell F

Aims

Computer hexapod assisted orthopaedic surgery (CHAOS), is a method to achieve the intra-operative correction of long bone deformities using a hexapod external fixator before definitive internal fixation with minimally invasive stabilisation techniques.

The aims of this study were to determine the reliability of this method in a consecutive case series of patients undergoing femoral deformity correction, with a minimum six-month follow-up, to assess the complications and to define the ideal group of patients for whom this treatment is appropriate.

Patients and Methods

The medical records and radiographs of all patients who underwent CHAOS for femoral deformity at our institution between 2005 and 2011 were retrospectively reviewed. Records were available for all 55 consecutive procedures undertaken in 49 patients with a mean age of 35.6 years (10.9 to 75.3) at the time of surgery.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1094 - 1099
1 Aug 2018
Gupta S Malhotra A Mittal N Garg SK Jindal R Kansay R

Aims

The aims of this study were to establish whether composite fixation (rail-plate) decreases fixator time and related problems in the management of patients with infected nonunion of tibia with a segmental defect, without compromising the anatomical and functional outcomes achieved using the classical Ilizarov technique. We also wished to study the acceptability of this technique using patient-based objective criteria.

Patients and Methods

Between January 2012 and January 2015, 14 consecutive patients were treated for an infected nonunion of the tibia with a gap and were included in the study. During stage one, a radical debridement of bone and soft tissue was undertaken with the introduction of an antibiotic-loaded cement spacer. At the second stage, the tibia was stabilized using a long lateral locked plate and a six-pin monorail fixator on its anteromedial surface. A corticotomy was performed at the appropriate level. During the third stage, i.e. at the end of the distraction phase, the transported fragment was aligned and fixed to the plate with two to four screws. An iliac crest autograft was added to the docking site and the fixator was removed. Functional outcome was assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) score.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 544 - 553
1 Apr 2017
Nandra RS Wu F Gaffey A Bache CE

Aims

Following the introduction of national standards in 2009, most major paediatric trauma is now triaged to specialist units offering combined orthopaedic and plastic surgical expertise. We investigated the management of open tibia fractures at a paediatric trauma centre, primarily reporting the risk of infection and rate of union.

Patients and Methods

A retrospective review was performed on 61 children who between 2007 and 2015 presented with an open tibia fracture. Their mean age was nine years (2 to 16) and the median follow-up was ten months (interquartile range 5 to 18). Management involved IV antibiotics, early debridement and combined treatment of the skeletal and soft-tissue injuries in line with standards proposed by the British Orthopaedic Association.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1296 - 1300
1 Sep 2015
Jauregui JJ Bor N Thakral R Standard SC Paley D Herzenberg JE

External fixation is widely used in orthopaedic and trauma surgery. Infections around pin or wire sites, which are usually localised, non-invasive, and are easily managed, are common. Occasionally, more serious invasive complications such as necrotising fasciitis (NF) and toxic shock syndrome (TSS) may occur.

We retrospectively reviewed all patients who underwent external fixation between 1997 and 2012 in our limb lengthening and reconstruction programme. A total of eight patients (seven female and one male) with a mean age of 20 years (5 to 45) in which pin/wire track infections became limb- or life-threatening were identified. Of these, four were due to TSS and four to NF. Their management is described. A satisfactory outcome was obtained with early diagnosis and aggressive medical and surgical treatment.

Clinicians caring for patients who have external fixation and in whom infection has developed should be aware of the possibility of these more serious complications. Early diagnosis and aggressive treatment are required in order to obtain a satisfactory outcome.

Cite this article: Bone Joint J 2015;97-B:1296–1300.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects.

A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed.

The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result.

With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects.

Cite this article: Bone Joint J 2013;95-B:1667–72.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 361 - 366
1 Mar 2009
Kovoor CC Padmanabhan V Bhaskar D George VV Viswanath S

We present the results of ankle fusion using the Ilizarov technique for bone loss around the ankle in 20 patients. All except one had sustained post-traumatic bone loss. Infection was present in 17. The mean age was 33.1 years (7 to 71). The mean size of the defect was 3.98 cm (1.5 to 12) and associated limb shortening before the index procedure varied from 1 cm to 5 cm. The mean time in the external fixator was 335 days (42 to 870). Tibiotalar fusion was performed in 19 patients and tibiocalcaneal fusion in one. Associated problems included diabetes in one patient, pelvic and urethral injury in one, visual injury in one patient and ipsilateral tibial fracture in five. At the final mean follow-up of 51.55 months (24 to 121) fusion had been achieved in 19 of 20 patients. A total of 16 patients were able to return to work. The results were graded as good in 11 patients, fair in six and poor in three. The mean external fixation index was 8.8 days/mm (0 to 30). One patient with diabetes developed severe infection which required early removal of the fixator. Refractures occurred in three patients, two of which were at the site of fusion and one at a previous tibial shaft fracture site. Equinus deformity of the ankle fusion occurred after a further fracture in one patient. There were two patients with residual forefoot equinus, and one developed late valgus at the fusion site.

Poor consolidation of the regenerated bone in two patients was treated by bone grafting in one and by bone and fibular strut grafting in the other. Residual soft-tissue infection was still present in two patients.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 76 - 82
1 Jan 2015
Siebachmeyer M Boddu K Bilal A Hester TW Hardwick T Fox TP Edmonds M Kavarthapu V

We report the outcomes of 20 patients (12 men, 8 women, 21 feet) with Charcot neuro-arthropathy who underwent correction of deformities of the ankle and hindfoot using retrograde intramedullary nail arthrodesis. The mean age of the patients was 62.6 years (46 to 83); their mean BMI was 32.7 (15 to 47) and their median American Society of Anaesthetists score was 3 (2 to 4). All presented with severe deformities and 15 had chronic ulceration. All were treated with reconstructive surgery and seven underwent simultaneous midfoot fusion using a bolt, locking plate or a combination of both. At a mean follow-up of 26 months (8 to 54), limb salvage was achieved in all patients and 12 patients (80%) with ulceration achieved healing and all but one patient regained independent mobilisation. There was failure of fixation with a broken nail requiring revision surgery in one patient. Migration of distal locking screws occurred only when standard screws had been used but not with hydroxyapatite-coated screws. The mean American Academy of Orthopaedic Surgeons Foot and Ankle (AAOS-FAO) score improved from 50.7 (17 to 88) to 65.2 (22 to 88), (p = 0.015). The mean Short Form (SF)-36 Health Survey Physical Component Score improved from 25.2 (16.4 to 42.8) to 29.8 (17.7 to 44.2), (p = 0.003) and the mean Euroqol EQ‑5D‑5L score improved from 0.63 (0.51 to 0.78) to 0.67 (0.57 to 0.84), (p = 0.012).

Single-stage correction of deformity using an intramedullary hindfoot arthrodesis nail is a good form of treatment for patients with severe Charcot hindfoot deformity, ulceration and instability provided a multidisciplinary care plan is delivered.

Cite this article: Bone Joint J 2015;97-B:76–82.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 137 - 142
1 Jan 2014
Nayagam S Davis B Thevendran G Roche AJ

We describe the technique and results of medial submuscular plating of the femur in paediatric patients and discuss its indications and limitations. Specifically, the technique is used as part of a plate-after-lengthening strategy, where the period of external fixation is reduced and the plate introduced by avoiding direct contact with the lateral entry wounds of the external fixator pins. The technique emphasises that vastus medialis is interposed between the plate and the vascular structures.

A total of 16 patients (11 male and five female, mean age 9.6 years (5 to 17)), had medial submuscular plating of the femur. All underwent distraction osteogenesis of the femur with a mean lengthening of 4.99 cm (3.2 to 12) prior to plating. All patients achieved consolidation of the regenerate without deformity. The mean follow-up was 10.5 months (7 to 15) after plating for those with plates still in situ, and 16.3 months (1 to 39) for those who subsequently had their plates removed. None developed a deep infection. In two patients a proximal screw fractured without loss of alignment; one patient sustained a traumatic fracture six months after removal of the plate.

Placing the plate on the medial side is advantageous when the external fixator is present on the lateral side, and is biomechanically optimal in the presence of a femoral defect. We conclude that medial femoral submuscular plating is a useful technique for specific indications and can be performed safely with a prior understanding of the regional anatomy.

Cite this article: Bone Joint J 2014;96-B:137–42.