Advertisement for orthosearch.org.uk
Results 1 - 20 of 50
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims

This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant.

Methods

A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1336 - 1344
1 Oct 2018
Powell AJ Crua E Chong BC Gordon R McAuslan A Pitto RP Clatworthy MG

Aims. This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study. Patients and Methods. A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m. 2. (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups. Results. At the ten-year follow-up, the RP group (n = 39) had a statistically significant superior score in the OKS (p = 0.001), WOMAC (p = 0.023), SF-12 PCS (p = 0.019), KOOS Activities of Daily Living (ADL) (p = 0.010), and KOOS Sport and Recreation (Sport/Rec) (p = 0.006) compared with the FB group (n = 46). The OKS, SF-12 PCS, and KOOS Sport/Rec at ten years had mean scores above the minimal clinically important difference (MCID) threshold. There was no significant difference in prevalence of radiolucency between groups at five-years’ follow-up (p = 0.449), nor at ten-years’ follow-up (p = 0.08). Implant survival rate at 14 years postoperative was 95.2 (95% CI 90.7 to 99.8) and 94.7 (95% CI 86.8 to 100.0) for the RP and FB TKAs, respectively. Conclusion. At ten-year follow-up, the mobile-bearing knee joint arthroplasty had statistically and clinically relevant superior OKS, SF-12 PCS, and KOOS (Sport/Rec) than the fixed-bearing platform. No difference was seen in prevalence of radiolucent lines. There was a greater than 94% implant survival rate for both cohorts at 14 years. Cite this article: Bone Joint J 2018;100-B:1336–44


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 740 - 748
1 Jun 2018
Clement ND Bardgett M Weir D Holland J Gerrand C Deehan DJ

Aims. The primary aim of this study was to assess the rate of patient satisfaction one year after total knee arthroplasty (TKA) according to the focus of the question asked. The secondary aims were to identify independent predictors of patient satisfaction according to the focus of the question. Patients and Methods. A retrospective cohort of 2521 patients undergoing a primary unilateral TKA were identified from an established regional arthroplasty database. Patient demographics, comorbidities, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and 12-Item Short-Form Health Survey (SF-12) scores were collected preoperatively and one year postoperatively. Patient satisfaction was assessed using four questions, which focused on overall outcome, activity, work, and pain. Logistic regression analysis was used to identify independent preoperative predictors of increased stiffness when adjusting for confounding variables. Results. Using patient satisfaction with the overall outcome (n = 2265, 89.8%) as the standard, there was no difference in the rate of satisfaction for pain relief (n = 2277, odds ratio (OR) 0.95, 95% confident intervals (CI) 0.79 to 1.14, p = 0.60), but patients were more likely to be dissatisfied with activities (79.3%, n = 2000/2521, OR 2.22, 95% CI 1.96 to 2.70, p < 0.001) and work (85.8%, n = 2163/2521, OR 1.47, 95% CI 1.23 to 1.75, p < 0.001). Logistic regression analysis identified different predictors of satisfaction for each of the focused satisfaction questions. Overall satisfaction was influenced by diabetes (p = 0.03), depression (p = 0.004), back pain (p < 0.001), and SF-12 physical (p = 0.008) and mental (p = 0.01) components. Satisfaction with activities was influenced by depression (p = 0.001), back pain (p < 0.001), WOMAC stiffness score (p = 0.03), and SF-12 physical (p < 0.001) and mental (p < 0.001) components. Satisfaction with work was influenced by depression (p = 0.007), back pain (p < 0.001), WOMAC function (p = 0.04) and stiffness (p = 0.05) scores, and SF-12 physical (p < 0.001) and mental (p < 0.001) components. Satisfaction with pain relief was influenced by diabetes (p < 0.001), back pain (p < 0.001), and SF-12 mental component (p = 0.04). Conclusion. The focus of the satisfaction question significantly influences the rate and the predictors of patient satisfaction after TKA. Cite this article: Bone Joint J 2018;100-B:740–8


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 360 - 366
1 Mar 2013
Clement ND MacDonald D Burnett R

We assessed the effect of mental disability on the outcome of total knee replacement (TKR) and investigated whether mental health improves post-operatively. Outcome data were prospectively recorded over a three-year period for 962 patients undergoing primary TKR for osteoarthritis. Pre-operative and one year Short-Form (SF)-12 scores and Oxford knee scores (OKS) were obtained. The mental component of the SF-12 was stratified into four groups according to level of mental disability (none ≥ 50, mild 40 to 49, moderate 30 to 39, severe < 30). Patients with any degree of mental disability had a significantly greater subjective physical disability according to the SF-12 (p = 0.06) and OKS (p < 0.001). The improvement in the disease-specific score (OKS) was not affected by a patient’s mental health (p = 0.33). In contrast, patients with mental disability had less of an improvement in their global physical health (SF-12) (p < 0.001). However, patients with any degree of mental disability had a significant improvement in their mental health post-operatively (p < 0.001). Despite a similar improvement in their disease-specific scores and improvement in their mental health, patients with mental disability were significantly more likely to be dissatisfied with their TKR at one year (p = 0.001). Patients with poor mental health do benefit from improvements in their mental health and knee function after TKR, but also have a higher rate of dissatisfaction. Cite this article: Bone Joint J 2013;95-B:360–6


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1463 - 1470
1 Nov 2018
Murphy BPD Dowsey MM Spelman T Choong PFM

Aims. As the population ages, there is projected to be an increase in the level of demand for total knee arthroplasty (TKA) in octogenarians. We aimed to explore whether those aged ≥ 80 years achieved similar improvements in physical function to younger patients while also comparing the rates of length of stay (LOS), discharge to rehabilitation, postoperative complications, and mortality following TKA in older and younger patients. Patients and Methods. Patients from one institution who underwent primary elective TKA between 1 January 2006 and 31 December 2014 were dichotomized into those ≥ 80 years old (n = 359) and those < 80 years old (n = 2479) for comparison. Multivariable regression was used to compare the physical status component of the 12-Item Short-Form Health Survey (SF-12), LOS, discharge to rehabilitation, complications, and mortality between the two groups. Results. Both age groups demonstrated a clinically meaningful improvement in their self-reported physical health relative to their baseline with no clinically relevant difference noted between them. Being ≥ 80 years old was associated with a 0.58-day increase in LOS and older patients were more likely to be discharged to rehabilitation (odds ratio (OR) 3.06, p < 0.001). Medical complications and mortality were higher in elderly patients (OR 1.92 for complications, p < 0.001; hazard ratio 3.40 for death, p < 0.001). There was no statistically significant association between age group and experiencing a postoperative surgical or wound-related complication. Conclusion. Those aged over 80 years achieved a statistically significant lower median SF-12 physical score than the younger group, after adjusting for the preoperative score, but this difference of 4.46 was not considered to be clinically meaningful. However, clinicians should be aware that the elderly are at a higher risk of experiencing longer hospital stays, postoperative medical complications, and mortality. Cite this article: Bone Joint J 2018;100-B:1463–70


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 48 - 54
1 Jul 2019
Kahlenberg CA Lyman S Joseph AD Chiu Y Padgett DE

Aims. The outcomes of total knee arthroplasty (TKA) depend on many factors. The impact of implant design on patient-reported outcomes is unknown. Our goal was to evaluate the patient-reported outcomes and satisfaction after primary TKA in patients with osteoarthritis undergoing primary TKA using five different brands of posterior-stabilized implant. Patients and Methods. Using our institutional registry, we identified 4135 patients who underwent TKA using one of the five most common brands of implant. These included Biomet Vanguard (Zimmer Biomet, Warsaw, Indiana) in 211 patients, DePuy/Johnson & Johnson Sigma (DePuy Synthes, Raynham, Massachusetts) in 222, Exactech Optetrak Logic (Exactech, Gainesville, Florida) in 1508, Smith & Nephew Genesis II (Smith & Nephew, London, United Kingdom) in 1415, and Zimmer NexGen (Zimmer Biomet) in 779 patients. Patients were evaluated preoperatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), Lower Extremity Activity Scale (LEAS), and 12-Item Short-Form Health Survey questionnaire (SF-12). Demographics including age, body mass index, Charlson Comorbidity Index, American Society of Anethesiologists status, sex, and smoking status were collected. Postoperatively, two-year KOOS, LEAS, SF-12, and satisfaction scores were compared between groups. Results. Outcomes were available for 4069 patients (98%) at two years postoperatively. In multiple regression analysis, which separately compared each implant group with the aggregate of all others, there were no clinically significant differences in the change of KOOS score from baseline to two-year follow-up between any of the groups. More than 80% of patients in each group were satisfied at this time in all domains. In a multivariate regression model, patients in the NexGen group were the most likely to be satisfied (odds ratio (OR) 1.63; p = 0.006) and Optetrak Logic patients were the least likely to be satisfied (OR 0.60; p < 0.001). Conclusion. TKA provides improvement in function and satisfaction regardless of the type of implant. We could not demonstrate superiority of one design above others across these groups of implants, and any price premium for one above the other systems may not be justified. Healthcare administrators may find these similarities in outcomes helpful when negotiating purchasing contracts. Cite this article: Bone Joint J 2019;101-B(7 Supple C):48–54


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1596 - 1602
1 Dec 2006
Muller SD Deehan DJ Holland JP Outterside SE Kirk LMG Gregg PJ McCaskie AW

The role of modular tibial implants in total knee replacement is not fully defined. We performed a prospective randomised controlled clinical trial using radiostereophotogrammetric analysis to compare the performance of an all-polyethylene tibia with a metal-backed cruciate-retaining condylar design, PFC-∑ total knee replacement for up to 24 months. There were 51 patients who were randomised into two treatment groups. There were 10 subsequent withdrawals, leaving 21 all-polyethylene and 20 metal-backed tibial implants. No patient was lost to follow-up. There were no significant demographic differences between the groups. At two years one metal-backed implant showed migration > 1 mm, but no polyethylene implant reached this level. There was a significant increase in the SF-12 and Oxford knee scores after operation in both groups. In an uncomplicated primary total knee replacement the all-polyethylene PFC-∑ tibial prosthesis showed no statistical difference in migration from that of the metal-backed counterpart. There was no difference in the clinical results as assessed by the SF-12, the Oxford knee score, alignment or range of movement at 24 months, although these assessment measures were not statistically powered in this study


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 344 - 350
1 Mar 2017
Metcalfe AJ Clark DA Kemp MA Eldridge JD

Aims. The Bereiter trochleoplasty has been used in our unit for 12 years to manage recurrent patellar instability in patients with severe trochlea dysplasia. The aim of this study was to document the outcome of a large consecutive cohort of patients who have undergone this operation. Patients and Methods. Between June 2002 and August 2013, 214 consecutive trochleoplasties were carried out in 185 patients. There were 133 women and 52 men with a mean age of 21.3 years (14 to 38). All patients were offered yearly clinical and radiological follow-up. They completed the following patient reported outcome scores (PROMs): International Knee Documentation Committee subjective scale, the Kujala score, the Western Ontario and McMaster Universities Arthritis Index score and the short-form (SF)-12. . Results. Outcomes were available for 199 trochleoplasties in 173 patients giving a 93% follow-up rate at a mean of 4.43 years (1 to 12). There were no infections or deep vein thromboses. In total, 16 patients reported further patella dislocation, giving an 8.3% rate of recurrence. There were 27 re-operations, giving a rate of re-operation of 14%. Overall, 88% were satisfied with the operation and 90% felt that their symptoms had been improved. . Conclusion. All PROMs improved significantly post-operatively except for the mental component score of the SF-12. Trochleoplasty performed using a flexible osteochondral flap is an effective treatment for recurrent patellar instability in patients with severe trochlea dysplasia and gives good results in the medium term. Cite this article: Bone Joint J 2017;99-B:344–50


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 669 - 679
1 Jul 2024
Schnetz M Maluki R Ewald L Klug A Hoffmann R Gramlich Y

Aims

In cases of severe periprosthetic joint infection (PJI) of the knee, salvage procedures such as knee arthrodesis (KA) or above-knee amputation (AKA) must be considered. As both treatments result in limitations in quality of life (QoL), we aimed to compare outcomes and factors influencing complication rates, mortality, and mobility.

Methods

Patients with PJI of the knee and subsequent KA or AKA between June 2011 and May 2021 were included. Demographic data, comorbidities, and patient history were analyzed. Functional outcomes and QoL were prospectively assessed in both groups with additional treatment-specific scores after AKA. Outcomes, complications, and mortality were evaluated.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1632 - 1639
1 Dec 2013
Clement ND MacDonald D Simpson AHRW Burnett R

This study assessed the effect of concomitant back pain on the Oxford knee score (OKS), Short-Form (SF)-12 and patient satisfaction after total knee replacement (TKR). It involved a prospectively compiled database of demographics and outcome scores for 2392 patients undergoing primary TKR, of whom 829 patients (35%) reported back pain. Compared with those patients without back pain, those with back pain were more likely to be female (odds ratio (OR) 1.5 (95% confidence interval (CI) 1.3 to 1.8)), have a greater level of comorbidity, a worse pre-operative OKS (2.3 points (95% CI 1.7 to 3.0)) and worse SF-12 physical (2.0 points (95% CI 1.4 to 2.6)) and mental (3.3 points (95% CI 2.3 to 4.3)) components. One year post-operatively, those with back pain had significantly worse outcome scores than those without with a mean difference in the OKS of 5 points (95% CI 3.8 to 5.4), in the SF-12 physical component of 6 points (95% CI 5.4 to 7.1) and in the mental component of 4 points (95% CI 3.1 to 4.9). Patients with back pain were less likely to be satisfied (OR 0.62, 95% CI 0.5 to 0.78). After adjusting for confounding variables, concomitant back pain was an independent predictor of a worse post-operative OKS, and of dissatisfaction. Clinicians should be aware that patients suffering concomitant back pain pre-operatively are at an increased risk of being dissatisfied post-operatively. Cite this article: Bone Joint J 2013;95-B:1632–9


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1253 - 1258
1 Sep 2010
Scott CEH Howie CR MacDonald D Biant LC

Up to 20% of patients are not satisfied with the outcome following total knee replacement (TKR). This study investigated the pre- and post-operative predictors of dissatisfaction in a large cohort of patients undergoing TKR. We assessed 1217 consecutive patients between 2006 and 2008 both before operation and six months after, using the Short-form (SF)-12 health questionnaire and the Oxford Knee Score. Detailed information concerning comorbidity was also gathered. Satisfaction was measured at one year when 18.6% (226 of 1217) of patients were unsure or dissatisfied with their replacement and 81.4% (911 of 1217) were satisfied or very satisfied. Multivariate regression analysis was performed to identify independent predictors of dissatisfaction. Significant (p < 0.001) predictors at one year included the pre-operative SF-12 mental component score, depression and pain in other joints, the six-month SF-12 score and poorer improvement in the pain element of the Oxford Knee Score. Patient expectations were highly correlated with satisfaction. Satisfaction following TKR is multifactorial. Managing the expectations and mental health of the patients may reduce dissatisfaction. However, the most significant predictor of dissatisfaction is a painful total knee replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 339 -
1 Apr 2001
Dunbar MJ Robertsson O Ryd L Lidgren L

The Swedish Knee Arthroplasty Registry (SKAR) has recorded knee arthroplasties prospectively in Sweden since 1975. The only outcome measure available to date has been revision status. While questionnaires on health outcome may function as more comprehensive endpoints, it is unclear which are the most appropriate. We tested various outcome questionnaires in order to determine which is the best for patients who have had knee arthroplasty as applied in a cross-sectional, discriminative, postal survey. Four general health questionnaires (NHP, SF-12, SF-36 and SIP) and three disease/site-specific questionnaires (Lequesne, Oxford-12, and WOMAC) were tested on 3600 patients randomly selected from the SKAR. Differences were found between questionnaires in response rate, time required for completion, the need for assistance, the efficiency of completion, the validity of the content and the reliability. The mean overall ranks for each questionnaire were generated. The SF-12 ranked the best for the general health, and the Oxford-12 for the disease/site-specific questionnaires. These two questionnaires could therefore be recommended as the most appropriate for use with a large knee arthroplasty database in a cross-sectional population


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 125 - 131
1 Jan 2020
Clement ND Weir DJ Holland J Deehan DJ

Aims

The primary aim of this study was to assess whether pain in the contralateral knee had a clinically significant influence on the outcome of total knee arthroplasty (TKA) according to the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. Secondary aims were to: describe the prevalence of contralateral knee pain; identify if it clinically improves after TKA; and assess whether contralateral knee pain independently influences patient satisfaction with their TKA.

Methods

A retrospective cohort of 3,178 primary TKA patients were identified from an arthroplasty database. Patient characteristics, comorbidities, and WOMAC scores were collected preoperatively and one year postoperatively for the index knee. In addition, WOMAC pain scores were also collected for the contralateral knee. Overall patient satisfaction was assessed at one year. Preoperative contralateral knee pain was defined according to the WOMAC score: minimal (> 78 points), mild (59 to 78), moderate (44 to 58), and severe (< 44). Multivariate regression analysis was used to adjust for confounding.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 855 - 863
1 May 2021
Koster LA Meinardi JE Kaptein BL Van der Linden - Van der Zwaag E Nelissen RGHH

Aims

The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS).

Methods

A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 586 - 592
1 May 2020
Wijn SRW Rovers MM van Tienen TG Hannink G

Aims

Recent studies have suggested that corticosteroid injections into the knee may harm the joint resulting in cartilage loss and possibly accelerating the progression of osteoarthritis (OA). The aim of this study was to assess whether patients with, or at risk of developing, symptomatic osteoarthritis of the knee who receive intra-articular corticosteroid injections have an increased risk of requiring arthroplasty.

Methods

We used data from the Osteoarthritis Initiative (OAI), a multicentre observational cohort study that followed 4,796 patients with, or at risk of developing, osteoarthritis of the knee on an annual basis with follow-up available up to nine years. Increased risk for symptomatic OA was defined as frequent knee symptoms (pain, aching, or stiffness) without radiological evidence of OA and two or more risk factors, while OA was defined by the presence of both femoral osteophytes and frequent symptoms in one or both knees. Missing data were imputed with multiple imputations using chained equations. Time-dependent propensity score matching was performed to match patients at the time of receving their first injection with controls. The effect of corticosteroid injections on the rate of subsequent (total and partial) knee arthroplasty was estimated using Cox proportional-hazards survival analyses.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 852 - 860
1 Jul 2020
Zamora T Garbuz DS Greidanus NV Masri BA

Aims

Our objective is to describe our early and mid-term results with the use of a new simple primary knee prosthesis as an articulating spacer in planned two-stage management for infected knee arthroplasty. As a second objective, we compared outcomes between the group with a retained first stage and those with a complete two-stage revision.

Methods

We included 47 patients (48 knees) with positive criteria for infection, with a minimum two-year follow-up, in which a two-stage approach with an articulating spacer with new implants was used. Patients with infection control, and a stable and functional knee were allowed to retain the initial first-stage components. Outcomes recorded included: infection control rate, reoperations, final range of motion (ROM), and quality of life assessment (QoL) including Western Ontario and McMaster Universities osteoarthritis index, Knee Injury and Osteoarthritis Outcome Score, Oxford Knee Score, 12-Item Short-Form Health Survey questionnaire, and University of California Los Angeles (UCLA) activity score and satisfaction score. These outcomes were evaluated and compared to additional cohorts of patients with retained first-stage interventions and those with a complete two-stage revision. Mean follow-up was 3.7 years (2.0 to 6.5).


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 845 - 851
1 Jul 2020
Goh GS Liow MHL Tay YWA Chen JY Xu S Pang H Tay DK Chia S Lo N Yeo S

Aims

While patients with psychological distress have poorer short-term outcomes after total knee arthroplasty (TKA), their longer-term function is unknown. We aimed to 1) assess the influence of preoperative mental health status on long-term functional outcomes, quality of life, and patient satisfaction; and 2) analyze the change in mental health after TKA, in a cohort of patients with no history of mental health disorder, with a minimum of ten years’ follow-up.

Methods

Prospectively collected data of 122 patients undergoing primary unilateral TKA in 2006 were reviewed. Patients were assessed pre- and postoperatively at two and ten years using the Knee Society Knee Score (KSKS) and Function Score (KSFS); Oxford Knee Score (OKS); and the Mental (MCS) and Physical Component Summary (PCS) which were derived from the 36-Item Short-Form Health Survey questionnaire (SF-36). Patients were stratified into those with psychological distress (MCS < 50, n = 51) and those without (MCS ≥ 50, n = 71). Multiple regression was used to control for age, sex, BMI, Charlson Comorbidity Index (CCI), and baseline scores. The rate of expectation fulfilment and satisfaction was compared between patients with low and high MCS.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 213 - 220
1 Feb 2019
Xu S Lim WJ Chen JY Lo NN Chia S Tay DKJ Hao Y Yeo SJ

Aims

The aim of this study was to assess the influence of obesity on the clinical outcomes and survivorship ten years postoperatively in patients who underwent a fixed-bearing unicompartmental knee arthroplasty (UKA).

Patients and Methods

We prospectively followed 184 patients who underwent UKA between 2003 and 2007 for a minimum of ten years. A total of 142 patients with preoperative body mass index (BMI) of < 30 kg/m2 were in the control group (32 male, 110 female) and 42 patients with BMI of ≥ 30 kg/m2 were in the obese group (five male, 37 female). Pre- and postoperative range of movement (ROM), Knee Society Score (KSS), Oxford Knee Score (OKS), 36-Item Short-Form Health Survey (SF-36), and survivorship were analyzed.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 565 - 572
1 May 2019
Teeter MG Marsh JD Howard JL Yuan X Vasarhelyi EM McCalden RW Naudie DDR

Aims

The purpose of the present study was to compare patient-specific instrumentation (PSI) and conventional surgical instrumentation (CSI) for total knee arthroplasty (TKA) in terms of early implant migration, alignment, surgical resources, patient outcomes, and costs.

Patients and Methods

The study was a prospective, randomized controlled trial of 50 patients undergoing TKA. There were 25 patients in each of the PSI and CSI groups. There were 12 male patients in the PSI group and seven male patients in the CSI group. The patients had a mean age of 69.0 years (sd 8.4) in the PSI group and 69.4 years (sd 8.4) in the CSI group. All patients received the same TKA implant. Intraoperative surgical resources and any surgical waste generated were recorded. Patients underwent radiostereometric analysis (RSA) studies to measure femoral and tibial component migration over two years. Outcome measures were recorded pre- and postoperatively. Overall costs were calculated for each group.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1025 - 1032
1 Aug 2020
Hampton M Mansoor J Getty J Sutton PM

Aims

Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design.

Methods

Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m2 (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up.